Search NASA⌕ Search

SEARCH · Search NASA

Results for “Medical research”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Measurement of the 230 Th( p ,2n)Pa229 and 230 Th( p ,3n)Pa228 reaction cross sections from 14.1 to 16.9 MeV

Actinium-225 is of interest for medical isotope production and there is on-going research into methods of producing Ac 225 , either directly or via the decay of its parent isotopes ( Th 229 , Pa 229 , and Ra 225 ). One method that has been suggested is the Th 230 ( p , 2 n ) Pa 229 reaction. However, there is no available cross-section data for this reaction in the literature. Purpose: Measure the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reaction cross sections in the energy range where the ( p , 2 n ) reaction is predicted to peak to determine the feasibility of Ac 225 production via the Th 230 ( p , 2 n ) reaction. Methods: Targets naturally enriched in Th 230 were irradiated at the Center for Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory with energies ranging from 14.1 to 16.9 MeV. Furthermore, chemical processing was used to separate the protactinium activation products, followed by γ -ray spectroscopy to measure the activities of Pa 228 , 229 , 230 , 232 produced in the irradiation. Results: We find that excitation functions are reported for the first time in the literature for the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reactions in this energy range. The peak measured value of the Th 230 ( p , 2 n ) reaction was found to be 182 ± 12 mb at 14.4 ± 0.1 MeV. The Th 232 ( p , n ) Pa 232 reaction was used to verify the experimental conditions, the measured values are reported and are comparable to the existing literature values. From the γ -ray spectrometry data, the half-life of Pa 229 was measured as 1.5 ± 0.1 days, which is within the error of the half-life reported in the evaluated nuclear data as well as in the recent measurements, and the half-life of Pa 228 was measured as 19.5 ± 0.4 hours. Conclusions: Overall, the Th 230 ( p , 2 n ) Pa 229 reaction could reasonably be used for Ac 225 isotope production, although significant amounts of relatively isotopically pure Th 230 would be needed for significant production because the low alpha-decay branching ratio of Pa 229 and long half-life of Th 229 inhibit the in-growth of significant amounts of Ac 225 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MINOS Infrasound Analysis Synopsis

This report was written as a guide to working with infrasound data collected as part of the Multi-Informatics for Nuclear Operations Scenarios (MINOS)project, an NA-22 funded venture. The main purpose of overall MINOS project is the combination of multiple, disparate data modalities to characterize the operations at a nuclear facility, specifically instrumenting and studying the High-Flux Isotope Reactor (HFIR) and Radiochemical Engineering Development Center (REDC) locate at Oak Ridge National Laboratory in Oak Ridge, TN. HFIR is an 85 MW research reactor and is used primarily for production of medical radioisotopes, material irradiation experiments, neutron activation, and neutron scattering. Targets for the reactor are constructed, processed, and dissolved at REDC. REDC also hosts other glove-box and hot-cell type activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission Induced Radiolysis of Uranyl Sulfate Solutions

At Argonne National Laboratory, an experimental pilot facility is being tested for the production of the medical isotope molybdenum-99 ( 99 Mo). AMORE (Argonne Molybdenum Research Experiment) is an experimental pilot facility in which a 40 MeV electron beam from the LINAC strikes a depleted uranium (DU) target. The target generates high energy neutrons, which are thermalized in an 18-liter uranyl sulfate solution of low enriched uranium (LEU). Thermalized neutrons fission the uranium-235 ( 235 U) to produce 99 Mo as well as many other fission products. The 99 Mo is recovered from the uranium solution and purified. The goal of our work is to reduce the use of highly enriched uranium (HEU) for the production of this isotope.

07 ISOTOPE AND RADIATION SOURCES↗

A membrane-based approach to medical isotope purification (Final Report)

This is the final technical report from the grant "A membrane-based approach to medical isotope purification" which was awarded by the Isotope Research and Development Program through the early career research program to Christine Duval at Case Western Reserve University. The project developed adsoprtive membranes with covalently bound diglycolamide-derived ligands for the purification of Ac-225 and benchmarked them against the current state of the art adsorbent materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Xenon Abatement Simulations to Support the KAERI Medical Isotope Facility

To maintain and improve the verification regime that is outlined by the Preparatory Commission of the Comprehensive Nuclear Test-Ban Treaty there is a need to understand and reduce the radioxenon releases from medical isotope production facilities. In support of this objective Pacific Northwest National Laboratory (PNNL) was tasked with, modeling and evaluate the abatement process and delay bed designs for the medical isotope production facility under construction by the Korea Atomic Energy Research Institute (KAERI). This report includes this analysis and provides PNNL proposed modifications to the KAERI adsorption bed design.

07 ISOTOPE AND RADIATION SOURCES↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quapprox: A Framework for Benchmarking the Approximability of Variational Quantum Circuit

Most of the existing quantum neural network models, such as variational quantum circuits (VQCs), are limited in their ability to explore the non-linear relationships in input data. This gradually becomes the main obstacle for it to tackle realistic applications, such as natural language processing, medical image processing, and wireless communications. Recently, there have emerged research efforts that enable VQCs to perform non-linear operations. However, it is still unclear on the approximability of a given VQC (i.e., the order of non-linearity that can be handled by a specified design). In response to this issue, we developed an automated tool designed to benchmark the approximation of a given VQC. The proposed tool will generate a set of synthetic datasets with different orders of non-linearity and train the given VQC on these datasets to estimate their approximability. Our experiments benchmark VQCs with different designs, where we know their theoretic approximability. We then show that the proposed tool can precisely estimate the approximability, which is consistent with the theoretic value, indicating that the proposed tool can be used for benchmarking the approximability of a given quantum circuit for learning tasks.

artificial intelligence↗

A 15-Mev/nucleon Iso-Cyclotron for Security and Radioisotope Production

Cargo inspection systems exploit the broad bremsstrahlung spectrum from a 6-10 MeV, low-duty cycle electron accelerator which in the presence of significant backgrounds presents challenges in image and material identification. An alternative approach is to use ions which can excite nuclear states either directly, or through generation of secondary high-energy signature gammas produced from nuclear interactions in a target. RadiaBeam is designing a compact sector isocyclotron 1.25 m in radius, with high-gradient cavities to accelerate multi-ion species up to 15-20 MeV/u with large turn-to turn, centimeter-level separation for low-loss extraction without lossy foil stripping. A strong-focusing radial field profile will be optimized in a separated-sector format for control over machine tune simultaneous with isochronous orbist requirements for high-current (~0.5 milliamp) operation. Innovation in injection will be introduced to replace the high-loss central region. Non-security applications of the cyclotron include medical isotope production, ion radiobiology, as well as material science research and ion instrumentation development.

43 PARTICLE ACCELERATORS↗

Building Interfaces with Echo Using R

The following report details the functionality that was developed to directly query the MongoDB and read in echo records from within R, and the ability to create a cinema database directly from echo records. Both of these efforts used the data collected under the MINOS project for development. The nuclear facility under consideration is the High-Flux Isotope Reactor (HFIR) and co-located Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory in Oak Ridge, TN. HFIR is an 85 MW research reactor and is used primarily for production of a medical radioisotopes, material irradiation experiments, neutron activation, and neutron scattering. Targets for the reactor are fabricated and processed and dissolved at REDC, in addition to other glove-box and hot-cell type activities. An overhead view of the facility is provided. The rest of the report is organized as follows: Section 2 describes how to query the MongoDB and load in echo records from within R, with background information on the database type, MongoDB, and the file format of echo records, hdf5, as well as lessons learned during the development phase. Section 3 details the functionality and usage of creating a cinema database directly from echo records within R. A series of appendixes display all the R code (Section 5), some example scripts where the code is used (Section 6), and useful links for further exploration (Section 7).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Overview on Current Activities of Conduction-Cooled SRF Accelerators and their Applications

When Nb3Sn was reintroduced to the SRF community as an alternative to pure niobium, one key motivation has been to reduce the cryogenic requirements of new and existing accelerators by shifting from 2 K to 4 K operation. Meanwhile, a variety of implementations beyond research machines are being explored. The combination of Nb3Sn with conventional cryocoolers, enabling cryogen-free operation, has paved the way for the development of compact, standalone systems suitable for applications far beyond research, such as enhancing the durability of synthetics via crosslinking or sterilizing food and medical equipment, as well as environmental cleanup when it comes to decontaminating liquid and solid waste material. So, while fundamental R&D continues to refine Nb3Sn resonators, exploring improvements such as replacing the niobium substrate with copper, parallel research efforts are investigating how the increased beam power provided by SRF could expand the commercial use of electron beams. This presentation aims to deliver a comprehensive overview of ongoing research efforts to harness the benefits of SRF through Nb3Sn and conduction cooling.

Vennekate, John [Thomas Jefferson National Acceler↗

Beam optics design of a prototype 20 kW conduction-cooled SRF accelerator for medical sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

Saini, A. [Fermilab]↗

Beam Optics Design of A Prototype 20 kW Conduction-Cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Beam Optics Design of a Prototype 20 KW Conduction-cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

CPAP Ventilators Needed for Rapid Response to COVID-19 by Modification of CPAP Equipment

Early on in the COVID-19 pandemic, potential ventilator shortages were a critical issue identified by national health care providers. Capacity modeling at the time suggested patient demand may exceed ventilator supply. Thus, the challenge became finding an urgent interim solution to meet health care needs. Our initial hypothesis was that CPAP technology could be modified to provide similar functionality to a ventilator, relieving demand and allowing physicians to decide which patients need high end machines, ultimately saving lives. In conjunction with medical experts and pulmonologists, we were able to identify three key thrusts associated with this research problem: (1) modification of CPAP technology to allow for 02 input that would be capable of providing ventilation; (2) development of an alarming function that would provide real-time audible alarms to alert medical personnel to critical conditions, which would be used inline with CPAP technology; and (3) a method of sterilizing expiratory air from such a system in order to protect medical personnel from biohazard, since CPAPs vent to the atmosphere. We were unable to realize results for thrust 1 (CPAP modification for 02); we identified potential safety issues associated with utilizing medical grade oxygen with a common CPAP device. In order to characterize and mitigate these issues, we would need to partner closely with a device manufacturer; such a partnership could not be achieved in the timeframe needed for this rapid response work. However, we determined that some medical grade BiPAP devices do not need this modification and that the significant progress on thrusts 2 and 3 would be sufficient to buy down risk of a massive ventilator shortage. Our team built a prototype alarm system that can be utilized with any assistive respiratory device to alert on all key conditions identified by medical personnel (high pressure, low pressure, apnea, loss of power, low battery). Finally, our team made significant progress in the rapid prototyping and demonstration of an inline UV air purifier device. The device is cost efficient and can be manufactured at scale with both commercially available and additively manufactured parts. Initial tests with SARS-CoV-2 analog bacteriophage MS2 show 99% efficacy at reducing bioburden. Following a successful demonstration of the prototype device with medical personnel, we were able to obtain follow-on (non-LDRD) funding to provide additional device characterization, validation, and production in order to respond to an immediate regional need.

42 ENGINEERING↗

The Future of LANSCE [Slides]

LANSCE is a NNSA Center for Materials and Nuclear Research. An aging stockpile presents unique challenges in materials and nuclear science. The grand challenge of a predictive materials capability includes design to manufacture and born certified. This requires capability to study manufacture to structure relationships and capability to study structure to performance relationships. LANSCE has the capabilities needed for this mission. We leverage our capability to provide broader benefit to the Nation including production of medical isotopes, industrial irradiation facility for electronics certification, and fundamental materials and physics research. The LANSCE linear accelerator is nearly 50 years old. The severity of maintenance issues is increasing. We must reinvest in LANSCE to ensure mission delivery into the future. We must develop new capability to be responsive to changing mission needs. Ultimately this will require a Dynamic Mesoscale Materials Science Capability. Now we must develop a pathway to MaRIE that ensures continued operation of LANSCE.

43 PARTICLE ACCELERATORS↗

Development and implementation of an in situ high-resolution isotopic microscope for measuring metabolic interactions in soil mesocosms (Final Report)

Many of our planet’s ecosystems rely on the activities of soil microbial communities. These microbes have significant and wide-ranging effects: they metabolize carbon and other nutrients, interact with plants and fungi, and perform other processes important to soil health. However, our ability to directly observe the enzymatic and metabolic activities of microbes within soil is currently limited, not only by the complexity of soil microbial communities themselves, but also by the lack of experimental tools to study them and their molecular interactions in situ. These challenges hinder our understanding of the lifesustaining processes of biomass decomposition and the manner in which it contributes to the movement of freed carbon within soil ecosystems. Here we aim to develop a novel ultrahigh-resolution isotopic microscope that combines complementary imaging modalities to gain insights into metabolic cycling in soil. This final report covers the portion of this work that was completed at the University of North Carolina at Chapel Hill from 2018 to 2019; the research is continuing through 2022 at the University of Massachusetts Chan Medical School.

59 BASIC BIOLOGICAL SCIENCES↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗