Search NASA⌕ Search

SEARCH · Search NASA

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Towards Non-Intrusive Real-Time Monitoring of Behind the Meter Residential Distributed Energy Resources

The growing adoption of residential distributed energy resources (DERs) introduces more uncertain variability in power grid operation. More importantly, the residential DERs operate behind customers’ energy meters, and therefore, the utility cannot “directly” monitor them. Prior approaches to enable visibility into behind-the-meter (BTM) DERs either depend on estimations or require intrusive instrumentation on the customer side. To address the critical need for direct real-time monitoring of BTM DERs, in this paper, we propose a novel approach for utility-side direct real-time monitoring of residential BTM DERs. We utilize high-frequency (> 10kHz) conducted electromagnetic interference (EMI) from residential DERs’ grid-tied inverters to monitor their power generation. We discuss the working principle of our approach and present supporting results using three of-the-shelf grid-tied inverters.

14 SOLAR ENERGY↗

Workshop: Advanced Metering for Decarbonization: Electric Vehicles and 24/7 Carbon-Free Electricity

The purpose of this workshop is to learn more about advanced metering best practices for meeting the goals of EO 14057. This will be a 2-part session, first part to include presentations on the FEMP best practice work related to metering: 1) Electric Vehicles (EVs) and EV charging station electricity use. 2) Integrating data sources to calculate hourly carbon pollution-free electricity (CFE). Second part will facilitate small group discussions with a problem-solving activity.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Deep-learning-based canopy height model generation from sub-meter resolution panchromatic satellite imagery

Canopy height models (CHMs) with sufficient resolution to distinguish individual trees are useful for a variety of applications. However, standard techniques to acquire such data, such as airborne lidar surveying, are often prohibitively expensive. Deep learning techniques for generating CHMs from high-resolution imagery are an attractive option to reduce costs. To date, success with these methods has been demonstrated using multichannel aerial photography and specialized satellite data products derived from multiple sensors, neither of which is commonly available at temporal resolutions finer than one year. Here we demonstrate a method to generate sub-meter resolution CHMs in three forests in California using a more abundant data source: sub-meter resolution, panchromatic satellite imagery from a single sensor. We show that phenology and species composition play important roles in model transferability; when trained using imagery from a single conifer forest in autumn, the model performs well on autumn imagery from a second conifer forest several hundred kilometers distant with no re-training. With modest additions to the training dataset, the same model generates minimally biased estimates of canopy height in both conifer and deciduous forests during multiple seasons. Because the model operates on satellite data with global coverage and a relatively short return interval, we propose its suitability to extrapolate tree-level canopy height data to remote regions and conduct high-temporal resolution monitoring of forest structure. We furthermore demonstrate the workflow’s applicability to fire modeling by conducting simulations in forests populated by trees measured using both this approach and airborne lidar surveying. We find minimal differences in fire behavior relative to a baseline case in which only statistical distributions of tree height and crown area are known. This result underscores the value of forest structural information derived from our workflow for improving the fidelity of wildland fire simulations, among other ecological applications.

54 ENVIRONMENTAL SCIENCES↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Development of a Half-Meter Scale Traveling-Wave (TW) SRF Cavity

While a demonstration of TW resonance excitation in the 3-cell structure in 2K liquid helium had been prepared and carried out at Fermilab in collaboration with Euclid Techlabs, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab as the next step of TW development towards an accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing), Fermilab has proposed a half-meter scale TW RF design consisting of a 7-cell structure and a power feedback waveguide (WG) loop. The WG loop design includes the new RF configurations for TW resonance control during a high-power operation. 1-year US-Japan collaboration program focused on EBW optimization for the TW shape iris joint within the narrow gap was awarded and the efforts has been made by Fermilab, Jlab, and KEK. 1-year LDRD program of Fermilab is awarded recently to fabricate a low-cost mockup of the WG loop with new RF configurations and validate them. Here we will present a preliminary 7-cell TW RF design and will report the progress and challenges through the programs awarded.

43 PARTICLE ACCELERATORS↗

Connectivity Troubleshooting Guide for Advanced Electricity Meters

This guide is designed to walk users through a troubleshooting process for disconnected advanced electricity meters. The guide centers on two connectivity troubleshooting decision trees related to power issues and network connectivity issues, respectively. Additionally, it contains additional background information such as definitions, diagrams, and checklists that can help a user prepare to troubleshoot meter connectivity issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mock-Up Waveguide Loop Development toward a Half-Meter Scale Traveling-Wave SRF Cavity

Mock-up waveguide loop development toward a half-meter scale traveling-wave SRF cavity ABSTRACT = Traveling-Wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demonstrate those new RF schemes at a room temperature. Fabrication drawings of a mock-up loop were completed. More details and plans of the development will be presented.

Furuta, Fumio [Fermilab]↗

Torque meter aids study of hysteresis motor rings

Torque meter, simulating hysteresis motor operation, allows rotor ring performance characteristics to be analyzed. The meter determines hysteresis motor torque and actual stresses of the ring due to its mechanical situation and rotation, aids in the study of asymmetries or defects in motor rings, and measures rotational hysteresis.

Cole, M.↗

Venturi meter with separable diffuser

The diffuser and nozzle of venturi meters are made as separate pieces for easier fabrication. Venturi meter efficiency is affected by the diffuser inlet diameter being greater than two percent larger than the throat diameter, by Reynolds number and by Mach number.

Dudzinski, T. J.↗

Three-meter telescope study

A means is presented whereby the effect of various changes in the most important parameters of a three meter aperature space astronomy telescope can be evaluated to determine design trends and to optimize the optical design configuration. Methods are defined for evaluating the theoretical optical performance of axisymmetric, centrally obscured telescopes based upon the intended astronomy research usage. A series of design parameter variations is presented to determine the optimum telescope configuration. The design optimum requires very fast primary mirrors, so the study also examines the current state of the art in fabricating large, fast primary mirrors. The conclusion is that a 3-meter primary mirror having a focal ratio as low as f/2 is feasible using currently established techniques.

Wissinger, A.↗

Static structural tests of a 1.5-meter diameter fabric attached inflatable decelerator

Meridional tape forces, permeability, and change in model contours were measured on the aft half of a 1.5-m-diameter attached inflatable decelerator (AID). Inflation pressures up to 103 kN per square meter and external pressures of 0.14 to 102 kN per square meter were used. The results indicated that the model stresses were near the desired isotensoid condition. Future AID designs should consider both stiffness and strength of the meridional tapes to obtain the optimum division of load between tapes and fabric. Permeability of pressurized fabric structures is a few orders of magnitude higher than that obtained in the standard low-pressure test on material specimens.

Willis, C. M.↗

Drag characteristics of a disk-gap-band parachute with a nominal diameter of 1.65 meters at Mach numbers from 2.0 to 3.0

Supersonic wind-tunnel tests were conducted with disk-gap-band parachute models having a nominal diameter of 1.65 meters and geometric porosities of 10.0, 12.5, and 15.0 percent. Canopy inflation characteristics, angles of attack, and drag performance are presented for deployment behind forebody base extensions which were free to oscillate in pitch and yaw. The effect of increasing suspension-line length on canopy motions and drag performance is included, and the drag performance of a model with 12.5 percent geometric porosity is compared with results from flight tests of a parachute with a nominal diameter of 12.19 meters.

Mayhue, R. J.↗

Acoustic and aerodynamic performance of a 1.83 meter (6 foot) diameter 1.2 pressure ratio fan (QF-6)

A 1.2-pressure-ratio, 1.83-meter-(6-ft-) diameter experimental fan stage with characteristics suitable for use in STOL aircraft engines was tested for acoustic and aerodynamic performance. The design incorporated features for low noise, including absence of inlet guide vanes, low rotor-blade-tip speed, low aerodynamic blade loading, and long axial spacing between the rotor and stator rows. The stage was run with four nozzles of different area. The perceived noise along a 152.4 meter (500-ft) sideline was rear-quadrant dominated with a maximum design-point level of 103.9 PNdb. The acoustic 1/3-octave results were analytically separated into broadband and pure-tone components. It was found that the stage noise levels generally increase with a decrease in nozzle area, with this increase observed primarily in the broadband noise component. A stall condition was documented acoustically with a 90-percent-of-design-area nozzle.

Woodward, R. P.↗

Meter for use in detecting tension in straps having predetermined elastic characteristics

A meter for detecting tension in elastic bodies, especially in fabric straps employed as tie down straps for stowed objects is presented. The meter is characterized by a pair of elongated arms coupled together for pivotal motion about a common axis in a common plane and a strap receiver located at adjacent ends of the arms for receiving and securing adjacent portions of the strap. The receivers are supported by the arms for motion along intersecting arcs, and motion detection means is located at the opposite ends of the arms for detecting the magnitude of the motion imparted to the receivers as the strap is placed in tension.

Buhler, G. V.↗