Search NASA⌕ Search

SEARCH · Search NASA

Results for “Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

L2 Earth Atmosphere Observatory: Formation Guidance, Metrology and Control Synthesis

The Earth Observatory Formation at L2, a Lagrange libration point, is a unique large aperture (25 m diameter) space telescope concept that will improve the knowledge and understanding of dynamic, chemical and radiative mechanisms that cause changes in the atmosphere, and can lead to the development of models and techniques to predict short and long-term climate changes. The results of this concept definition study show that the telescope concept is feasible, and can have technology readiness in the 2020 time frame. Further advanced development in several subsystems is needed, such as higher efficiency Xenon ion thrusters with throttling, and optical quality large membrane mirror with active shape control. It presents an analysis and solution of guidance, sensing, control, and propulsion problems for a formation of two spacecraft on the Sun-Earth line in the neighborhood of the Sun-Earth L2 point, that observes Earth s atmosphere during continuous solar occultation by the Earth. A system architecture is described for the observatory, and its components that include unique mission specific metrology. The formation must follow a powered trajectory with strictly limited fuel use to observe solar occultation. A configuration of ion thrusters and reaction wheels for translation and attitude control is designed along with algorithms for orbit following and formation control. Simulation results of the orbital and formation dynamics are presented that verify performance of the control systems.

Earth Atmosphere Observatory Formation↗

Large Volume, Optical and Opto-Mechanical Metrology Techniques for ISIM on JWST

The final, flight build of the Integrated Science Instrument Module (ISIM) element of the James Webb Space Telescope is the culmination of years of work across many disciplines and partners. This paper covers the large volume, ambient, optical and opto-mechanical metrology techniques used to verify the mechanical integration of the flight instruments in ISIM, including optical pupil alignment. We present an overview of ISIM's integration and test program, which is in progress, with an emphasis on alignment and optical performance verification. This work is performed at NASA Goddard Space Flight Center, in close collaboration with the European Space Agency, the Canadian Space Agency, and the Mid-Infrared Instrument European Consortium.

ISIM↗

Metrology system for Space Interferometry Mission system testbed 3

In a 3-baseline interferometer fourteen metrology gauges are used to monitor changes in the two baselines and calculate the length of the third. Simulation for estimating the third baseline indicates measurement capability of better than 1 nm error.

interferometry↗

Deep Space 3 Metrology System

A metrology subsystem on board the Deep Space 3, a separated interferometer mission, is used to determine stellar fringe delay jitter, delay rate, and intial delay.

Deep↗

Harnessing on-machine metrology data for prints with a surrogate model for laser powder directed energy deposition

In this study, we leverage the massive amount of multi-modal on-machine metrology data generated from Laser Powder Directed Energy Deposition (LP-DED) to construct a comprehensive surrogate model of the 3D printing process. By employing Dynamic Mode Decomposition with Control (DMDc), a data-driven technique, we capture the complex physics inherent in this extensive dataset. This physics-based surrogate model emphasizes thermodynamically significant quantities, enabling us to accurately predict key process outcomes. The model ingests 21 process parameters, including laser power, scan rate, and position, while providing outputs such as melt pool temperature, melt pool size, and other essential observables. Furthermore, it incorporates uncertainty quantification to provide bounds on these predictions, enhancing reliability and confidence in the results. We then deploy the surrogate model on a new, unseen part and monitor the printing process as validation of the method. Our experimental results demonstrate that the predictions align with actual measurements with high accuracy, confirming the effectiveness of our approach. Furthermore, this methodology not only facilitates real-time predictions but also operates at process-relevant speeds, establishing a basis for implementing feedback control in LP-DED.

Digital twins↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

Nuclear spin metrology with nitrogen vacancy center in diamond for axion dark matter detection

We present a method to directly detect the axion dark matter using nitrogen vacancy centers in diamonds. In particular, we use metrology leveraging the nuclear spin of nitrogen to detect axion-nucleus couplings. This is achieved through protocols designed for dark matter searches, which introduce a novel approach of quantum sensing techniques based on the nitrogen vacancy center. Although the coupling strength of the magnetic fields with nuclear spins is three orders of magnitude smaller than that with electron spins for conventional magnetometry, the axion interaction strength with nuclear spins is the same order of magnitude as that with electron spins. Furthermore, we can take advantage of the long coherence time by using the nuclear spins for the axion dark matter detection. Our method has the potential to be sensitive to a broad frequency range ≲ 100 Hz corresponding to the axion mass m a ≲ 4 × 10 − 13 eV . We present the detection limit of our method for both the axion-neutron and the axion-proton couplings and discuss its significance in comparison with other proposed ideas. We also show that the sensitivities of the NV center sensor to various spin species will open up new directions for constructing protocols that can mitigate magnetic noise effects. Published by the American Physical Society 2025

Chigusa, So (ORCID:0000000160054447)↗

Quantum metrology of low-frequency electromagnetic modes with frequency upconverters

We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the very high frequency band (VHF) ( ≲ 300 MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ( ∼ 5 GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use nonclassical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc VHF electromagnetic modes as quantum sensors with sensitivity better than the standard quantum limit (SQL). We demonstrate signal upconversion from low frequencies to the microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of 46.9 dB , which is a necessary step towards the realization of full BAE. Published by the American Physical Society 2025

Kuenstner, Stephen E. (ORCID:0000000346128846)↗

WFSUITE: A PYTHON SOFTWARE SUITE FOR X-RAY WAVEFRONT SENDING AND AT-WAVELENGTH METROLOGY

SF-26-025 WFSuite is a graphical and command-line toolkit for coded-mask-based X-ray wavefront sensing and phase reconstruction at synchrotron beamlines. It integrates analysis tools for both relative and absolute speckle-based measurements. In the relative metrology module, WFSuite implements Wavelet-transform-based X-ray Speckle Tracking (WXST) and Wavelet-transform-based Speckle Vector Tracking (WSVT) methods to retrieve differential phase and wavefront distortions by comparing speckle patterns recorded with and without the test sample. In the absolute phase module, WFSuite uses coded-mask speckle patterns and replaces the measured reference with a numerically simulated one, enablingsingle-shot wavefront reconstruction using either WXST or a neural-network-based method (SPINNet).

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Synchrotron X-ray metrology of dopant distribution and oxidation state in high pressure CVD grown TM 2+ :ZnSe optical fibers

High pressure chemical vapor deposition (HPCVD) has shown to be a promising method for producing Cr 2+ :ZnSe and Fe 2+ :ZnSe mid-IR optical fiber lasers. The oxidation state of the dopants and their spatial homogeneity are critical for the characterization of effective fiber laser performance; however, this is challenging for small fiber cores and small doping concentrations. We demonstrate using synchrotron micro X-ray fluorescence (XRF) mapping to study the distribution of the dopants throughout the fiber cross-sections. Furthermore, we study the local chemical environment of these unique fiber structures using micro X-ray near edge absorption spectroscopy (XANES). Our study reveals that transition metal doped ZnSe deposited using HPCVD has nanoscale dopant aggregation although the material is chemically identical to the commercially produced diffusion doped laser crystals, as indicated by the presence +2 oxidation state of the dopants. This work demonstrates the power of synchrotron-based X-ray techniques for use as metrology tools for improving the performance of laser materials in fiber geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗