Search NASA⌕ Search

SEARCH · Search NASA

Results for “Michelson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Infrared and millimeter wave techniques for the Cosmic Background Explorer Satellite

The Cosmic Background Explorer Satellite will employ infrared and microwave techniques to gain information about the very early universe. Three instruments will cover the spectral range from 8 microns to 13 mm, determining both the spectrum and angular distribution of the large scale background radiation fields. A cryogenic polarizing Michelson interferometric spectrometer will measure the spectrum of the 3 deg K relic radiation from the big bang with precision. Four differential microwave radiometers will map the sky from 23 to 90 GHz in a search for anisotropy of the universe. A broadband cryogenic IR photometer will map zodiacal dust emission, galactic dust, and an extragalactic residual component.

Mather, J. C.↗

A chevron beam-splitter interferometer

Fully tilt compensated double-pass chevron beam splitter, that removes channelling effects and permits optical phase tuning, is wavelength independent and allows small errors in alignment that are not tolerated in Michelson, Machzender, or Sagnac interferometers. Device is very useful in experiments where background vibration affects conventional interferometers.

Breckinridge, J. B.↗

Structural alignment sensor

Comparative Michelson interferometers are discussed as well as the operating range potential of a structural alignment sensor (SAS) which requires only one laser mode. Schematics are presented for the distance measurement logic, the basic SAS system, the SAS optical layout, the coarse measurement signal processor, and the measured range resolution.

Davis, L.↗

What the Voyager infrared investigators hope to learn about the Saturn system

The Voyager infrared investigation uses a Michelson interferometer (IRIS) covering the spectral range from 200 to 3000 cm/1 (3.3 to 50 micrometers) and a bore sighted radiometer covering the range from 5000 to 25000 cm/1 (0.4 to 2 micrometers). The spectral resolution of the interferometer is 4.3 cm/1 and the field of view is 0.25 deg. Scientific results anticipated from the investigation of the Saturnian system are discussed.

Hanel, R. A.↗

Determination of the Telluric Water Vapor Absorption Correction for Astronomical Data Obtained from the Kuiper Airborne Observatory

The amount of telluric water vapor along the line of sight of the Kuiper Airborne Observatory telescope as obtained concommitantly on 23 flights is compared with the NASA-Ames Michelson interferometer and with the NOAA-Boulder radiometer. A strong correlation between the two determinations exists, and a method for computing the atmospheric transmission for a given radiometer reading is established.

Erickson, E. F.↗

An analysis of water in galactic infrared sources using the NASA Lear Airborne Observatory

The Michelson interferometer system on the NASA Lear Jet Airborne Observatory is described as well as the data reduction procedures. The objects observed (standard stars, M stars, a nebula, planets, and the moon) are discussed and the observing parameters are listed for each flight date. The spectra obtained from these data flights are presented, grouped by class of object.

Smith, L. L.↗

Infrared spectra of lunar soils

Measured data obtained by Michelson interferometer spectrometer were stored in a computer file and smoothed by being passed forward and backward through a digital four-pole low pass filter. Infrared spectra of the 10 lunar samples are presented in the format of brightness temperature versus frequency. The mol % of feldspar, pyroxene, olivine, ilmenite and ferromagnetic silicate in each sample is presented in tables. The reflectance spectra of ilmenite and enstatite are shown in graphs.

Aronson, J. R.↗

Delay compensation - Its effect in reducing sampling errors in Fourier spectroscopy

An approximate formula is derived for the spectrum ghosts caused by periodic drive speed variations in a Michelson interferometer. The solution represents the case of fringe-controlled sampling and is applicable when the reference fringes are delayed to compensate for the delay introduced by the electrical filter in the signal channel. Numerical results are worked out for several common low-pass filters. It is shown that the maximum relative ghost amplitude over the range of frequencies corresponding to the lower half of the filter band is typically 20 times smaller than the relative zero-to-peak velocity error, when delayed sampling is used. In the lowest quarter of the filter band it is more than 100 times smaller than the relative velocity error. These values are ten and forty times smaller, respectively, than they would be without delay compensation if the filter is a 6-pole Butterworth.

Zachor, A. S.↗

A two-dimensional white-light amplitude interferometer

A review of the applications of a point-symmetric, 180-degree, rotational shearing interferometer is given. Material includes, photographs of the Michelson stellar interferometer fringes from Alpha-Lyr, measures of amplitude of phase excursions in the atmosphere, and a measure of the order of interference of speckle patterns. New material includes unpublished double star speckle patterns to illustrate the isoplanatic patch, a measure of the time fluctuations in the earth's atmosphere, and measurements of the properties of a 256 channel linear reticon.

Breckinridge, J. B.↗

Fourier emission infrared microspectrophotometer for surface analysis. I - Application to lubrication problems

A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.

Lauer, J. L.↗

A new atlas of infrared methane spectra between 1120 per cm and 1800 per cm

An atlas of 1339 methane absorption lines in the range 1120 to 1800 reciprocal centimeters, including the nu(4) and nu(2) bands, is presented. Laboratory spectra were obtained by a Nicolet Fourier transform Michelson interferometer with a resolution of approximately 0.06 reciprocal cm and a path length of 6.35 m of 0.98, 4.86 and 19.97 torr. Observed spectra are also compared with spectral intensities calculated line-by-line on the basis of tabulated intensities of the observed spectral lines.

Blatherwick, R. D.↗

Infrared spectrometer for Voyager

The Voyager IR investigation is described, which uses a Michelson interferometer in the 180-2500/cm range, and a single-channel radiometer for the visible and near-IR, sharing a 50-cm diameter telescope. Emphasis is placed on the differences between the Voyager and the previous designs, including reductions in the field of view and in the noise equivalent spectral radiance of the instrument. Attention is given to the optical layout, the electronics module, power supply placement, thermal control heaters and flash heaters, data reduction, and calibration. A sample spectrum of Jupiter is also discussed.

Hanel, R.↗

Far-infrared spectra of W51-IRS 2 and W49 NW

Measurements of the far-infrared spectra of the powerful H II regions W51-IRS 2 and W49 NW from 65 to 345 per cm with about 9 per cm resolution were obtained by using an airborne Michelson interferometer. The most remarkable feature of the far-infrared spectra of the two regions is the smoothness of the continuum; no evidence is found in the spectra for features of H2O ice at 45 and 62 microns. The spectrum of W51 is well fitted by a 70 K blackbody with a diameter of 14 arc sec, but the spectrum of W49 NW is narrower than a blackbody. The implications of the apparently high peak optical depths of these sources are discussed.

Erickson, E. F.↗

Grid polarizers for infrared Fourier spectrometers

Infrared grid polarizers consisting of copper lines with a 3.6-micron grid constant on a 4-micron-thick Mylar polyester substrate have been prepared by the techniques of photolithography and sputter-etching. Their polarization properties have been measured and found to be suitable for use at infrared frequencies below 700/cm. The polarizers have been used to extend the useful frequency range of a Martin-Puplett polarizing interferometer designed for Fourier transform spectroscopy. The efficiency of the interferometer has been measured over a frequency range from 50 to 700/cm and compared to that of a conventional Michelson interferometer. The results are shown to be consistent with the measured properties of the polarizers. Methods are suggested for improving the efficiency of a Martin-Puplett interferometer which employs these polarizers.

Challener, W. A.↗

The helium abundance of Jupiter from Voyager

Full disk measurements recorded 31 days before the Voyager 1 encounter with Jupiter by the radiometer of the infrared instrument, IRIS, indicate a geometric albedo of 0.274 + or - 0.013. Combining this measurement with the Pioneer derived phase integral of 1.25 and our error estimate of 0.1 yields a Jovian Bond albedo of 0.343 + or - 0.032. Infrared spectra recorded at the same time by the Michelson interferometer, along with a model extrapolation to low wave numbers not covered by the instrument, yield a thermal emission of (1.359 + or - 0.014) .001 W cm to the (-2) power. As in the case of the albedo measurement, the quoted errors in the emission measurement reflect estimates of systematic effects and are uncertain while the random component is negligible. From these measurements the internal heat flux of Jupiter is estimated to be (5.444 + or - 0.425) .0001 W cm to the (-2) power, and the energy balance defined as the ratio of emitted thermal to absorbed solar energy is 1.668 + or - 0.085.

Gautier, D.↗

Temperature dependence of HNO3 absorption in the 11.3-micron region

Laboratory spectra have been obtained for HNO3 with a Michelson-type Fourier transform interferometer using absorption cells with path lengths of 10.3, 25.5, and 49.8 cm at temperatures of 240, 248, 283, and 294 K. The measurements lead to a total band intensity value of 642 plus or minus 5% per sq cm amagat, which is a temperature independent value after the gas density correction has been made. However, the temperature dependence of the spectral absorption coefficients is apparent in the 885 kayser region.

Goldman, A.↗

Alignment of a two-beam interferometer

Two beam interferometers have been proposed for space applications such as sensing the shape of a large antenna. Since alignment and adjustment of interferometers have long been considered difficult laboratory tasks, the question of making their operation sufficiently automatic for space applications is a serious one. As a first step in addressing this question certain manual procedures, which may not be well known, have been collected from widely scattered sources. These techniques are illustrated by two examples: (1) the alignment of a Mach-Zehnder interferometer and the adjustment of fringe location. (2) The adjustment of a Michelson interferometer for zero path difference (white light fringes).

Tubbs, E. F.↗