Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

Siegmund, O. H. W.↗

Miniature, low-power X-ray tube using a microchannel electron generator electron source

Embodiments of the invention provide a novel, low-power X-ray tube and X-ray generating system. Embodiments of the invention use a multichannel electron generator as the electron source, thereby increasing reliability and decreasing power consumption of the X-ray tube. Unlike tubes using a conventional filament that must be heated by a current power source, embodiments of the invention require only a voltage power source, use very little current, and have no cooling requirements. The microchannel electron generator comprises one or more microchannel plates (MCPs), Each MCP comprises a honeycomb assembly of a plurality of annular components, which may be stacked to increase electron intensity. The multichannel electron generator used enables directional control of electron flow. In addition, the multichannel electron generator used is more robust than conventional filaments, making the resulting X-ray tube very shock and vibration resistant.

Elam, Wm. Timothy↗

Method for producing microchannels in drawn material

A microchannel glass article includes a glass body having a porous, spinodal nanostructure and defining at least one microchannel extending from a surface of the article substantially through the article.

36 MATERIALS SCIENCE↗

Preconcentration and separation of analytes in microchannels

Disclosed herein are methods and devices for preconcentrating and separating analytes such as proteins and polynucleotides in microchannels. As disclosed, at least one size-exclusion polymeric element is adjacent to processing area or an assay area in a microchannel which may be porous polymeric element. The size-exclusion polymeric element may be used to manipulate, e.g. concentrate, analytes in a sample prior to assaying in the assay area.

Hatch, Anson↗

Design and Optimization of a Gas-Cooled, Airfoil Fin Microchannel Heat Exchanger

High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, was analyzed and optimized using a design of experiments with artificial intelligence and machine learning techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin PCHEs has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure was developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. STAR-CCM+ was used to analyze a simplified two-channel configuration where five parameters were varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods were compared for generating surrogate models – a 5D polynomial and a regression neural network. A response surface approximation was created from the surrogate models and input to a genetic algorithm. The genetic algorithm identified a set of optimal points on the Pareto front. The optimal geometry was found across six channel Reynolds numbers ranging from 1000 to 5000 to analyze how varying inlet conditions affects the optimal design. A set of optimal designs that maximizes heat transfer and minimizes pressure drop was identified, and a thermal stress analysis was performed on the optimal design. This work has developed a digital framework for the expedient topology design and evaluation of PCHE designs for gas-cooled microreactor applications. Correlations for the Nusselt number and Darcy friction factor were developed that can be useful for thermal hydraulic analyses using system codes. A thermal stress analysis was conducted and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.

42 ENGINEERING↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

Experimental Evaluation of a Microchannel Condenser for R600a Domestic Refrigerators

Domestic refrigerators are among the most common household appliances, accounting for approximately 4% of total household energy consumption, which is higher than that of clothes dryers, lighting, or cooking appliances. With nearly 13 million new domestic refrigerators sold annually, even marginal improvements in their energy performance can yield significant reductions in overall energy demand and cost. This study focuses on enhancing the performance of domestic refrigerators using R600a as the refrigerant. Most domestic refrigerators currently employ wire-and-tube condensers, which are bulky and require a larger refrigerant charge. Given that R600a is classified as an A3 flammable refrigerant under ASHRAE standards, minimizing the system charge while maintaining or improving performance is critical. To address this, a compact and light weight single-pass serpentine microchannel heat exchanger (made of aluminum) was adopted as a condenser, replacing the conventional wire-and-tube configuration. The modified system was experimentally tested according to AHAM test standards, and charge optimization was performed. The results demonstrated that the refrigerator equipped with the microchannel condenser achieved a 5.3% reduction in energy consumption compared to the baseline configuration with wire-and-tube condenser.

Murugan, Muneeshwaran [ORNL] (ORCID:00000003340352↗

Apparatus for producing a thin sample band in a microchannel system

The present invention improves the performance of microchannel systems for chemical and biological synthesis and analysis by providing a method and apparatus for producing a thin band of a species sample. Thin sample bands improve the resolution of microchannel separation processes, as well as many other processes requiring precise control of sample size and volume. The new method comprises a series of steps in which a species sample is manipulated by controlled transport through a junction formed at the intersection of four or more channels. A sample is first inserted into the end of one of these channels in the vicinity of the junction. Next, this sample is thinned by transport across the junction one or more times. During these thinning steps, flow enters the junction through one of the channels and exists through those remaining, providing a divergent flow field that progressively stretches and thins the band with each traverse of the junction. The thickness of the resulting sample band may be smaller than the channel width. Moreover, the thickness of the band may be varied and controlled by altering the method alone, without modification to the channel or junction geometries. The invention is applicable to both electroosmotic and electrophoretic transport, to combined electrokinetic transport, and to some special cases in which bulk fluid transport is driven by pressure gradients. It is further applicable to channels that are open, filled with a gel or filled with a porous or granular material.

47 OTHER INSTRUMENTATION↗

Microchannel CO Methanation Reactors for Martian and Lunar ISRU

[Abstract] Microhannel technology offer significant advantages as a highly effective route to process intensification. NASA applications where size, weight, and process efficiency are key performance metrics, are very suitable applications. In situ resource utilization (ISRU) technologies is one such example. For use in a lunar carbothermal reduction process system a catalytic microchannel CO methanation reactor was developed. Design characteristics and operating performance evaluation for a multichannel reactor, approximately 4.5” X 0.5” X 1.0” in size, is discussed. Temperature, throughput, and mode of operation are variables explored. Two modes of operation were investigated: 1) under adiabatic conditions and 2) utilizing counter-current air cooling. The latter scenario offered a differential temperature profile which helped to improve performance. Demonstration of this concept is provided. Maintaining the inlet reactor temperature at 430oC the methane effluent composition output increased from 66.2% to 79.9% by introducing counter-flow air cooling. This allowed the exiting reactor temperature to decrease by ~ 100oC. Operating under such temperature differential conditions offeres exploitation of high kinetics at the hot front-end of the reactor while utilizing favorable thermodynamics at the cooler back-end. The highly efficient and compact nature of microchannel reactors make them uniquely suitable for such reaction engineering applications.

03 NATURAL GAS↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Development of a compact E ? B microchannel plate detector for beam imaging

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatial resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achieving high spatial resolution using a microchannel plate detector with an economic and scalable approach

We report a second generation position-sensitive microchannel plate detector using the induced signal approach has been realized. This detector is presently capable of measuring the incident position of electrons, photons, or ions. To assess the spatial resolution, the masked detector was illuminated by electrons. The initial, measured spatial resolution of 276 μm FWHM was improved by requiring a minimum signal amplitude on the anode and by employing digital signal processing techniques. The resulting measured spatial resolution of 119 μm FWHM corresponds to an intrinsic resolution of 98 μm FWHM when the effect of the finite slit width is de-convoluted. This measurement is a substantial improvement from the last reported spatial resolution of 466 μm FWHM using the induced signal approach. To understand the factors that limit the measured resolution, the performance of the detector is simulated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An efficient and cost-effective microchannel plate detector for slow neutron radiography

We report a novel approach for efficiently imaging objects with slow neutrons in two dimensions is realized. Neutron sensitivity is achieved by use of a boron doped microchannel plate (MCP). The resulting electron avalanche is further amplified with a Z-stack MCP before being sensed by two orthogonally oriented wire planes. Coupling of the wire planes to delay lines efficiently encodes the position information as a time difference. To determine the position resolution, slow neutrons were used to illuminate a Cd-mask placed directly in front of the detector. Peaks in the resulting spectrum exhibited an average peak width of 329 μm FWHM, corresponding to an average intrinsic resolution of 216 μm. The center region of the detector exhibits a significantly better spatial resolution with an intrinsic resolution of <100 μm observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Saturated critical heat flux in a multi-microchannel heat sink fed by a split flow system

An extensive experimental campaign has been carried out for the measurement of saturated critical heat flux in a multi-microchannel copper heat sink. The heat sink was formed by 29 parallel channels that were 199 {mu}m wide and 756 {mu}m deep. In order to increase the critical heat flux and reduce the two-phase pressure drop, a split flow system was implemented with one central inlet at the middle of the channels and two outlets at either end. The base critical heat flux was measured using three HFC Refrigerants (R134a, R236fa and R245fa) for mass fluxes ranging from 250 to 1500 kg/m{sup 2} s, inlet subcoolings from -25 to -5 K and saturation temperatures from 20 to 50 C. The parametric effects of mass velocity, saturation temperature and inlet subcooling were investigated. The analysis showed that significantly higher CHF was obtainable with the split flow system (one inlet-two outlets) compared to the single inlet-single outlet system, providing also a much lower pressure drop. Notably several existing predictive methods matched the experimental data quite well and quantitatively predicted the benefit of higher CHF of the split flow. (author)

42 ENGINEERING↗

Experimental studies of adiabatic flow boiling in fractal-like branching microchannels

Experimental results of adiabatic boiling of water flowing through a fractal-like branching microchannel network are presented and compared to numerical model simulations. The goal is to assess the ability of current pressure loss models applied to a bifurcating flow geometry. The fractal-like branching channel network is based on channel length and width ratios between adjacent branching levels of 2{sup -1/2}. There are four branching sections for a total flow length of 18 mm, a channel height of 150 {mu}m and a terminal channel width of 100 {mu}m. The channels were Deep Reactive Ion Etched (DRIE) into a silicon disk. A Pyrex disk was anodically bonded to the silicon to form the channel top to allow visualization of the flow within the channels. The flow rates ranged from 100 to 225 g/min and the inlet subcooling levels varied from 0.5 to 6 C. Pressure drop along the flow network and time averaged void fraction in each branching level were measured for each of the test conditions. The measured pressure drop ranged from 20 to 90 kPa, and the measured void fraction ranged from 0.3 to 0.9. The measured pressure drop results agree well with separated flow model predictions accounting for the varying flow geometry. The measured void fraction results followed the same trends as the model; however, the scatter in the experimental results is rather large. (author)

42 ENGINEERING↗

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct tests of a pixelated microchannel plate as the active element of a shower maximum detector

One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. As a result, a method for measuring the arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance studies of atomic layer deposited microchannel plate electron multipliers

Microchannel plate (MCP) photon counting, event timing, imaging detectors have found wide use in astronomical, remote sensing, and biological imaging applications. Novel MCP technology using borosilicate glass microcapillary array substrates functionalized by the application of resistive and secondary emissive layers using atomic layer deposition (ALD) techniques has the potential to outperform traditional MCP technology. Using ALD techniques to functionalize the MCPs allow customization of parameters like gain and resistance independently from the glass substrate. Borosilicate substrates have many advantages over traditional micro-capillary arrays, including low radioactive content, higher open area ratios, low outgassing, and high operational stability. These ALD MCPs can be manufactured in large areas (400 cm 2 ) providing a unique solution for many timing/imaging applications. ALD MCPs can withstand the processing temperatures required for high temperature deposition of III-V materials, such as Gallium Nitride, for UV photocathodes with high quantum efficiencies (QE) in the Near-UV (similar to 100-380 nm). We present the effects of different ALD configurations on the gain (magnitude and uniformity), resistance, imaging, background and detection efficiency, and how these parameters change during lifetime testing. Here, we also present the QE of ALD MCPs and various QE enhancement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗