Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microgrid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Protection of Renewable-dominated Microgrids: Challenges and Potential Solutions.

In this report we address the challenge of designing efficient protection system for inverter- dominated microgrids. These microgrids are characterised with limited fault current capacity as a result of current-limiting protection functions of inverters. Typically, inverters limit their fault contribution in sub-cycle time frame to as low as 1.1 per unit. As a result, overcurrent protection could fail completely to detect faults in inverter-dominated microgrids. As part of this project a detailed literature survey of existing and proposed microgrid protection schemes were conducted. The survey concluded that there is a gap in the available microgrid protection methods. The only credible protection solution available in literature for low- fault inverter-dominated microgrids is the differential protection scheme which represents a robust transmission-grade protection solution but at a very high cost. Two non-overcurrent protection schemes were investigated as part of this project; impedance-based protection and transient-based protection. Impedance-based protection depends on monitoring impedance trajectories at feeder relays to detect faults. Two communication-based impedance-based protection schemes were developed. the first scheme utilizes directional elements and pilot signals to locate the fault. The second scheme depends on a Central Protection Unit that communicates with all feeder relays to locate the fault based on directional flags received from feeder relays. The later approach could potentially be adapted to protect networked microgrids and dynamic topology microgrids. Transient-based protection relies on analyzing high frequency transients to detect and locate faults. This approach is very promising but its implementation in the filed faces several challenges. For example, high frequency transients due to faults can be confused with transients due to other events such as capacitor switching. Additionally, while detecting faults by analyzing transients could be doable, locating faults based on analyzing transients is still an open question.

24 POWER TRANSMISSION AND DISTRIBUTION↗

User Objectives and Design Approaches for Microgrids: Options for Delivering Reliability and Resilience, Clean Energy, Energy Savings, and Other Priorities

In fall 2019, the National Association of Regulatory Utility Commissioners (NARUC) and the National Association of State Energy Officials (NASEO) initiated a joint Microgrids State Working Group (MSWG), funded by the U.S. Department of Energy (DOE) Office of Electricity (OE). The MSWG aimed to bring together NARUC and NASEO members to explore the capabilities, costs, and benefits of microgrids; discuss barriers to microgrid development; and develop strategies to plan, finance, and deploy microgrids to improve resilience. Based on member input, the MSWG developed two companion briefing papers to answer key questions about microgrids: (1) User Objectives and Design Approaches for Microgrids: Options for Delivering Reliability and Resilience, Clean Energy, Energy Savings, and Other Priorities and (2) Private Sector, State, and Federal Funding and Financing Options to Enable Resilient, Affordable, and Clean Microgrids. Read together, these resources provide readers with an understanding of both why and how customers—whether an investor-owned, cooperative, or municipal utility; federal, state, or local government entity; individual or group of residential, commercial, and/or industrial customers; or other organization—select, design, and pay for microgrid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational Resilience of Nuclear-Renewable Integrated-Energy Microgrids

The increasing prevalence and severity of wildfires, severe storms, and cyberattacks is driving the introduction of numerous microgrids to improve resilience locally. While distributed energy resources (DERs), such as small-scale wind and solar photovoltaics with storage, will be major components in future microgrids, today, the majority of microgrids are backed up with fossil-fuel-based generators. Small modular reactors (SMRs) can form synergistic mix with DERs due to their ability to provide baseload and flexible power. The heat produced by SMRs can also fulfill the heating needs of microgrid consumers. This paper discusses an operational scheme based on distributed control of flexible power assets to strengthen the operational resilience of SMR-DER integrated-energy microgrids. A framework is developed to assess the operational resilience of SMR-DER microgrids in terms of system adaptive real-power capacity quantified as a response area metric (RAM). Month-long simulation results are shown with a microgrid developed in a modified Institute of Electrical and Electronics Engineers (IEEE)-30 bus system. The RAM values calculated along the operational simulation reflect the system resilience in real time and can be used to supervise the microgrid operation and reactor’s autonomous control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methods, systems, and computer readable media for protecting and controlling a microgrid with a dynamic boundary

Methods, systems, and computer readable mediums for protecting and controlling a microgrid with a dynamic boundary are disclosed. One method includes detecting a fault in a microgrid that includes a dynamic point-of-common-coupling (PCC), in response to determining that the microgrid is operating in a grid-connected mode, isolating the fault by tripping a microgrid side smart switch and a grid side smart switch that are located immediately adjacent to the fault, initiating the reclosing of the grid side smart switch, and initiating the reclosing for the microgrid side smart switch via resynchronization if the grid side smart switch is successfully reclosed, and in response to determining that the microgrid is operating in an islanded mode, isolating the fault by tripping a microgrid side smart switch that is located immediately adjacent to the fault, and initiating the reclosing of the microgrid side smart switch.

Wang, Fei↗

CERTS Microgrid Laboratory Test Bed

The objective of the CERTS Microgrid Test Bed project was to enhance the ease of integrating energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of generating sources less than 100kW. The techniques comprising the CERTS Microgrid concept are: 1 a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation, islanding the microgrid's load from a disturbance, thereby maintaining a higher level of service, without impacting the integrity of the utility's electrical power grid; 2 an approach to electrical protection within a limited source microgrid that does not depend on high fault currents; and 3 a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications between sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber-Resilient Automatic Generation Control for Systems of AC Microgrids

In this paper we propose a co-design of the secondary frequency regulation in systems of AC microgrids and its cyber security solutions. We term the secondary frequency regulator a Micro-Automatic Generation Control (μ AGC) for highlighting its same functionality as the AGC in bulk power systems. We identify sensory challenges and cyber threats facing the μ AGC. To address the sensory challenges, we introduce a new microgrid model by exploiting the rank-one deficiency property of microgrid dynamics. This model is used to pose an optimal μ AGC control problem that is easily implemented, because it does not require fast frequency measurements. An end-to-end cyber security solution to the False Data Injection (FDI) attack detection and mitigation is developed for the proposed μ AGC. The front-end barrier of applying off-the-shelf algorithms for cyber attack detection is removed by introducing a data-driven modeling approach. Finally, we propose an observer-based corrective control for an islanded microgrid and a collaborative mitigation scheme in systems of AC microgrids. We demonstrate a collaborative role of systems of microgrids during cyber attacks. Furthermore, the performance of the proposed cyber-resilient μ AGC is tested in a system of two networked microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controller Requirements for Managing Community Microgrids

Microgrid control systems are central to the functioning of a microgrid. They are responsible for managing distributed energy resources (DER) in both grid-connected and islanded modes of operation. Although microgrids are being developed and deployed by many utilities, several questions are being raised about the control system that manages them. This document provides the detailed list of requirements for a feeder-level microgrid controller to manage various islanded and grid-connected use cases. Functionally, the use cases include control scenarios that require the controller to maintain energy balance, prevent constraint violations, manage switching equipment, manage grid-forming (GFM) and grid-following (GFL) DER, manage critical/non-critical loads, and coordinate with peer systems to operate joined island areas. In addition to detailed requirements, the document includes interface and performance metrics for functional evaluation. These requirements can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; requirements also apply to third-party managed microgrid controllers that coordinate with the utility- and customer-owned equipment. The document can also be used by technology developers and project developers in industry to specify desired control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Retracted Article: Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. Here, to solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Resilience: A Holistic and Context-Aware Resilience Metric

Microgrids present an effective solution for the coordinated deployment of various distributed energy resources and furthermore provide myriad additional benefits such as resilience, decreased carbon footprint, and reliability to energy consumers and the energy system as a whole. Boosting the resilience of distribution systems is another major benefit of microgrids. This is because they can also serve as a backup power source when the utility grid's operations are interrupted due to either high-probability low-impact events like a component failure or low-probability high-impact events - be it a natural disaster or a planned cyberattack. However, the degree to which any particular system can defend, adapt, and restore normal operation depends on various factors including the type and severity of events to which a microgrid is subjected. These factors, in turn, are dependent on the geographical location of the deployed microgrid as well as the cyber risk profile of the site where the microgrid is operating. Therefore, in this work, we attempt to capture this multi-dimensional interplay of various factors in quantifying the ability of the microgrid to be resilient in these varying aspects. This paper, thus, proposes a customized site-specific quantification of the resilience strength for the individual microgrid's capability to absorb, restore, and adapt to the changing circumstances for sustaining the critical load when a low-probability high-impact event occurs - termed as - context-aware resilience metric. We also present a case study to illustrate the key elements of our integrated analytical approach.

microgrid↗

Integration of optimal operational dispatch and controller determined dynamics for microgrid survivability

We present that the reliability and resilience of the electrical power grids are essential to industry, economy and society. Microgrids that are able to island from the bulk electrical grid are one technology that may vastly improve electrical power service to customer loads. To achieve these improvements, an islanded microgrid should be able to operate through the loss of one of its generators without shedding electrical load. The loss of one generator will typically result in significant additional loads, including transient overloads, being placed on the remaining generators. There is also the possibility of additional generator tripping during these processes (i.e. cascading failures), which would likely result in the collapse of the microgrid. The novelty of our work consists in incorporating dynamic models of generator controllers into a microgrid optimal dispatch formulation with the ultimate goal to avoid operational failures and ensure the “survivability” of all-inverter microgrids to generator loss and transient overloads. The integration of generator and controller dynamics into the optimal dispatch formulation significantly increases the computational complexity. As we develop algorithms to restore speed of the optimization, our method can be readily implemented into a new operational strategy capable of an unprecedented level of reliability against generator contingencies. In addition, we quantitatively illustrate the effect of the survivability constraints on the microgrid operating costs and how the related trade-off between capital and operating costs should be taken into account at the design stage. Finally, the methods developed here also apply to the dispatch of off-grid microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Programmable intrusion detection for distributed energy resources in cyber–physical networked microgrids

We present a programmable intrusion detection method is presented to identify the malicious attacks to distributed energy resources (DERs) in the cyber-physical networked microgrids. The proposed method injects small programmable signals into the system and uses the response to identify abnormal conditions. Because of the low or even zero inertia induced by integrations of DER power-electronic-interfaces, microgrids have very limited resilience capability; and thus, being sensitive to attacks. One microgrid's malfunction caused by attacks can easily propagate to its neighboring systems when several microgrids are connected, leading to catastrophic electricity supply failures. Through the presented method, malicious intrusions can be effectively detected, located, and defended for securing microgrids. Theoretical derivations are provided to define the programmable detection rules. The detection rule is easy and flexible to update, making it difficult for attack actors to gain the knowledge of the detection rules, in order to avoid being detected. Numerical results on a cyber-physical networked microgrids system show that the proposed method is effective and efficient in precisely locating intrusion attacks to the microgrids system.

42 ENGINEERING↗

Validation of Microgrid Algorithms using At-Scale Simulation and Emulation Real-Time (ASSERT) Framework

This paper presents a novel framework for validating microgrid algorithms using a At-Scale Simulation and Emulation Real-Time (ASSERT) setup. The proposed universal microgrid validation framework was developed at Advanced Research on Integrated Energy Systems (ARIES) platform at National Renewable Energy Laboratory in Golden, Colorado, USA. As the number of intercommunicating devices grow in power systems, along with more integration of inverter-based resources, developing and validating microgrid operation and control algorithms is becoming complex and time-consuming task. The ASSERT framework is designed to provide a comprehensive, accurate, and efficient solution for validating microgrid algorithms. It combines at-scale simulations and real-time emulation to create a virtual environment that closely mimics the behavior of a physical microgrids which are characteristic of future smart distribution systems, such as: (1) increasing variability in the physical size of new energy technologies; (2) requiring control large numbers of interconnected devices, and (3) integrating diverse technologies that have not previously worked together. The paper describes the technical details of the ASSERT framework, its validation process, and its benefits over traditional validation methods. The framework's ability to validate the performance of various algorithms is demonstrated through a case study, which shows that it can effectively identify the weaknesses of an algorithm and optimize its performance. Overall, the ASSERT framework is a promising tool that can significantly enhance the development and validation of microgrid algorithms, leading to more reliable and efficient microgrid operation.

at-scale↗

Design of a State Machine for Smooth Microgrid Transition Operation

A state machine is proposed in the energy management system (EMS) of a microgrid as the solution for smooth microgrid's transition operation. This state machine includes six 'states' that cover all the operating modes during the microgrid's transition operation: two basic modes (grid-connected and islanded) and four temporary modes (preparing for disconnection, transition to islanding, preparing for resynchronization, and transition to grid-connected). Temporary modes are designed to fine-tune the control references for the microgrid assets to avoid harmful transients during microgrid transitions, therefore achieving smooth transition operation. The developed state machine is validated by simulation in MATLAB with a sample microgrid, and the test results show excellent performance of the state machine and smooth microgrid transition operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Safety-assured, real-time neural active fault management for resilient microgrids integration

Federated-learning-based active fault management (AFM) is devised to achieve real-time safety assurance for microgrids and the main grid during faults. AFM was originally formulated as a distributed optimization problem. Here, federated learning is used to train each microgrid's network with training data achieved from distributed optimization. The main contribution of this work is to replace the optimization-based AFM control algorithm with a learning-based AFM control algorithm. The replacement transfers computation from online to offline. With this replacement, the control algorithm can meet real-time requirements for a system with dozens of microgrids. By contrast, distributed-optimization-based fault management can output reference values fast enough for a system with several microgrids. More microgrids, however, lead to more computation time with optimization-based method. Distributed-optimization-based fault management would fail real-time requirements for a system with dozens of microgrids. Controller hardware-in-the-loop real-time simulations demonstrate that learning-based AFM can output reference values within 10 ms irrespective of the number of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Rotated Virtual Synchronous Generator Control for Power-Sharing in Microgrids with Complex Line Impedance

Virtual synchronous generator (VSG) control is based on the fact that the line impedance in a microgrid is highly inductive. This assumption was made due to the emulation of the stator winding of an electrical machine. This concept can affect the controllability of a microgrid with complex line impedance, generating deviations in the chosen operation point. To overcome this issue, additional techniques must be implemented. This paper describes a novel mathematical approach that uses the power line characteristics in a microgrid to rotate the power control reference frame and proposes a new control method called a “Rotated Virtual Synchronous Generator” (RVSG). This RVSG control approach integrates the effect of complex impedance on the microgrid’s operation and adjusts the reference frame accordingly to improve the system’s stability and performance. The use of this proposed mathematical approach in microgrids allows the further emulation of virtual inertia in microgrids that lack inertia. Finally, a comparison between RVSG control and the classical virtual synchronous generator method is carried out to show that it allows the improvement of the transient power response, power quality, stability, and performance, mainly in microgrids with complex line impedance.

42 ENGINEERING↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Performance of Solar Decathlon 2011 High-Penetration Microgrid: Preprint

The U.S. Department of Energy Solar Decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The Solar Decathlon 2011 was held in Washington, D.C., from September 23 to October 2, 2011 . A high-penetration microgrid was designed, installed, and operated for the Solar Decathlon 2011 to grid-connect 19 highlyenergy-efficient, solar-powered competition houses to a single utility connection point. The capacity penetration of this microgrid (defined as maximum PV generation divided by maximum system load over a two-week period) was 74% based on 1-minute averaged data. Temporary, ground-laid conductors and electrical distribution equipment were installed to grid-connect the Solar Decathlon village,which included the houses as well as other electrical loads used by the event organizers. While 16 of the houses were connected to the 60 Hz microgrid, three houses from Belgium, China, and New Zealand were supplied with 50 Hz power. The design of the microgrid, including the connection of the houses powered by 50 Hz and a standby diesel generator, is discussed in this paper. In addition to theutility-supplied net energy meters at each house, a microgrid monitoring system was installed to measure and record energy consumption and PV energy production at 1-second intervals at each house. Bidirectional electronic voltage regulators were installed for groups of competition houses, which held the service voltage at each house to acceptable levels. The design and successful performance ofthis high-penetration microgrid is presented from the house, microgrid operator, and utility perspectives.

14 SOLAR ENERGY↗