Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microgrid economics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Preliminary Assessment of PV + Electric Storage Options at the Energy Coordinating Agency

NREL used the REopt (R) platform to evaluate the techno-economic potential of adding solar PV and electric storage at the Energy Coordinating Agency (ECA) in Philadelphia, PA. The site has access to 600 PV panels (rated at 305 W each) and would like to evaluate the potential of pairing them with battery storage to offset electricity costs, increase renewable energy usage, and establish an onsite microgrid.

14 SOLAR ENERGY↗

SEIN: Breaking Barriers Resilient Energy System Analysis [Slides]

The Solar Energy Innovation Network (SEIN) is a collaborative research program that supports multi-stakeholder teams in researching and sharing solutions to real-world challenges associated with solar energy adoption. The Breaking Barriers project was selected to participate in the Solar Energy Innovation Network, Round 2, and was led by Groundswell, a D.C.-based clean energy project developer. The Breaking Barriers team included Partnership for Southern Equity, Atlanta University Center campus facility managers and professors, the City of Atlanta's Neighborhood Planning Unit T, and Georgia Power Company. The project aimed to design and construct innovative urban energy resiliency hubs integrating microgrid technology, solar generation, and energy storage in Atlanta colleges and communities. The hubs will help these historically Black colleges and universities (HBCUs) and the energy-burdened broader community in West Atlanta be more resilient, in addition to informing new course curricula at Atlanta University Center campuses. With many possible options for the system's battery size, the Breaking Barriers team needed insight into the relationships between BESS size, economic performance, and resilience at Spelman College's Manley Center. These insights are crucial for entering procurement negotiations with project developers, establishing resilience capabilities that the HBCU campuses can plan around, and guiding the team's fundraising targets. This analysis includes estimates of PV and battery performance, costs, savings, and resilience for multiple battery sizes. In order to provide power during a grid outage, the resilient energy system also needs to be connected to the Manley Center in a safe and island-able manner (electrically isolated from the grid). Analysis of potential electrical configurations and estimated setup costs is key to successfully entering a required interconnection agreement with Georgia Power, as well as informing requests for engineering firms to construct the system. This analysis includes conceptual options and rough order of magnitude cost estimates for electrically interconnecting the resilient energy system to the Manley Center and the grid. The Breaking Barriers team used this analysis to select preferred system characteristics and design for the resilient energy system.

14 SOLAR ENERGY↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

The Iowa Tribe of Kansas and Nebraska: Advancing Clean, Resilient, and Sovereign Energy (Summary Report of Communities LEAP Activities)

The Iowa Tribe of Kansas and Nebraska (ITKN) is a federally recognized Native American Tribe located along the Missouri River on the border of northeast Kansas and southeastern Nebraska. There are over 800 residents (Tribal citizens and non-Tribal) who live on the reservation, as well as more than 500 people who visit or work on the reservation on a daily basis. The ITKN faces many energy challenges, including rising service costs and dozens of power outages annually that impact resident well-being and business activities on Tribal lands. Power service issues are made more challenging by the remoteness of the reservation, which is 20 miles from the nearest town. Despite this, the ITKN has a long history of cultural and economic resilience: Local self-reliance, environmental stewardship, respecting the carrying capacity of the land, and strengthening the community are Tribal communities' traditional strengths. Long-term energy goals for the ITKN are centered around achieving energy sovereignty. Priority actions include: (1) Establishing a Tribal Utility Authority (TUA) to promote social welfare and community development.; (2) Deploying renewable community microgrids with ground-mount solar arrays and sustainable energy storage systems to advance energy sovereignty, resilience, and reliability. To advance these goals, the ITKN partnered with the U.S. Department of Energy's (DOE's) Communities LEAP (Local Energy Action Program) pilot. From August 2022 to March 2024, the ITKN community coalition collaborated with technical assistance providers at DOE's National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to evaluate TUA planning needs and microgrid deployment scenarios. This final report details the Communities LEAP technical assistance process, models and analysis performed, and results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Technical Diversity Benefits of Wind as a Distributed Energy Resource

Distributed energy resources are increasingly used in power distribution systems and microgrids to supply cost competitive power, improve resilience, and provide a host of grid services. Diversifying variable renewable resources (e.g., by combining wind with solar) can increase energy usage efficiency and improve system resilience. However, when grid optimization and resilience studies consider multiple renewable resources, diversity benefits are usually captured only implicitly in the results of location-specific economic optimization. In this paper, metrics are introduced to express the technical value of resource diversity independent of jurisdiction-specific market structures. Specifically, marginal energy usage efficiency metrics are developed to quantify the ability of new distributed generation to produce useful energy and an incremental sustainable ride through metric is developed to express improvement in grid outage ride through capability. While there are economic implications for each of these metrics, the metrics themselves are technically-driven and could be used as components of a technical figure of merit that could be used to inform policy actions, such as development of resource-specific incentives and time-of-use tariff designs. Each of these metrics is demonstrated using balance-of-energy simulations that highlight the benefits of improving resource diversity.

Reiman, Andrew P.↗

The Iowa Tribe of Kansas and Nebraska: Advancing Clean, Resilient, and Sovereign Energy

The Iowa Tribe of Kansas and Nebraska (ITKN) is a federally recognized Native American Tribe located along the Missouri River on the border of northeast Kansas and southeastern Nebraska. There are over 800 residents (Tribal citizens and non-Tribal) who live on the reservation, as well as more than 500 people who visit or work on the reservation on a daily basis. The ITKN faces many energy challenges, including rising service costs and dozens of power outages annually that impact resident well-being and business activities on Tribal lands. Power service issues are made more challenging by the remoteness of the reservation, which is 20 miles from the nearest town. Despite this, the ITKN has a long history of cultural and economic resilience: Local self-reliance, environmental stewardship, respecting the carrying capacity of the land, and strengthening the community are Tribal communities' traditional strengths. Long-term energy goals for the ITKN are centered around achieving energy sovereignty. Priority actions include: (1) Establishing a Tribal Utility Authority (TUA) to promote social welfare and community development.; (2) Deploying renewable community microgrids with ground-mount solar arrays and sustainable energy storage systems to advance energy sovereignty, resilience, and reliability. To advance these goals, the ITKN partnered with the U.S. Department of Energy's (DOE's) Communities LEAP (Local Energy Action Program) pilot. From August 2022 to March 2024, the ITKN community coalition collaborated with technical assistance providers at DOE's National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to evaluate TUA planning needs and microgrid deployment scenarios. This fact sheet provides an overview of the results and outcomes from the Communities LEAP technical assistance process.

Communities Leap↗

Project Planning for Community Resilience: Aquinnah and Chilmark, Massachusetts

This report presents the findings of an energy system planning study for the towns of Aquinnah and Chilmark, MA, on the island of Martha’s Vineyard, conducted under the U.S. Department of Energy ETIPP program. The study used the DER-CAM model to optimize the deployment of PV and battery microgrids to enhance energy resilience against power outages, particularly winter storms. Key findings show that PV is highly cost-effective and delivers net annual savings. However, due to limited rooftop space and low winter solar output, PV and battery storage alone cannot support the full critical load during outages. Solutions incorporating conventional backup generators were found to be more economically viable for achieving 100% critical load support.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of Materials-Based Options for On-Board Hydrogen Storage for Rail Applications

The objective of this project was to evaluate material- and chemical-based solutions for hydrogen storage in rail applications as an alternative to high-pressure hydrogen gas and liquid hydrogen. Three use cases were assessed: yard switchers, long-haul locomotives, and tenders. Four storage options were considered: metal hydrides, nanoporous sorbents, liquid organic hydrogen carriers, and ammonia, using 700 bar compressed hydrogen as a benchmark. The results suggest that metal hydrides, currently the most mature of these options, have the highest potential. Storage in tenders is the most likely use case to be successful, with long-haul locomotives the least likely due to the required storage capacities and weight and volume constraints. Overall, the results are relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of fuel cell electric locomotives. The results obtained here will contribute to the development of technical storage targets for rail applications that can guide future research. Moreover, the knowledge generated by this project will assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Energy Storage Integration and Management Platform for Buildings (SESIMP-B)

This project involved the design, development, and testing of a commercial smart service panel. It includes an innovative AI-driven control method to manage smart functions of the panel and a technical-economic feasibility assessment for enhancing building energy resilience and grid-edge technology integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis of Distributed Energy Generation in Crow Creek, Alaska

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Crow Creek in Girdwood, AK with a feasibility analysis for a microgrid to provide year-round power across the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exceedance Probabilities and Recurrence Intervals for Extended Power Outages in the United States

Power outages cause significant economic and societal impacts. An increasing likelihood of extreme weather coupled with aging grid infrastructure is leading to a higher prevalence of extended power outages, which can leave customers without power for multiple days or even weeks. Planners at the facility, local, state, and federal levels are interested in resilience solutions to reduce the impacts of extended power outages. Resilience solutions—such as installing backup systems, integrating microgrid solutions, weatherizing buildings, and hardening distribution and transmission components—can reduce the consequences of extended power outages, but these solutions come with increased capital costs. Conducting cost-benefit analyses is important for determining which steps to take to mitigate the impact of power outages without investing in ineffective and cost-prohibitive resilience solutions. The expected benefits of resilience investments depend on the frequency of power outages of various durations, particularly extended outages lasting several hours, days, or weeks. A significant barrier to resilience planning is the lack of publicly available data on the frequency and duration of extended power outages. The absence of outage duration information severely limits the ability to conduct quantitative cost-benefit analyses of resilience investments. This report provides estimates of recurrence intervals and conditional exceedance probabilities for major power outages by U.S. region between 2015 and 2021. Additionally, we provide estimates for grid management, particularly outages caused by California’s public safety power shutoffs (PSPS), and for natural outages caused by major hurricanes. Outage recurrence intervals are the average number of years between outage events, and conditional exceedance probabilities are the likelihoods that a customer who experiences a major power outage will experience an outage exceeding a given duration. Major outage events are those that affect 10,000 or more customers, as defined by the U.S. Department of Energy’s (DOE’s) Electric Emergency Incident and Disturbance Report, called OE-417 (DOE 2020). These results can be applied to determine the likelihood of experiencing long-duration outages, which can be integrated into cost-benefit analyses of resilience solutions and broader energy resilience studies. We developed a methodology to estimate customer outage durations for extended outage events using publicly available data on customer outages. Shorter-duration power outages are relatively common, with customers experiencing on average more than one power outage each year lasting fewer than 12 hours. An outage event lasting between 1 day and 1 week is expected to occur between once every 16 years and once every 42 years, depending on the region, with an average recurrence rate of once every 32 years across the contiguous United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing DER Deployment for Climate, Health, Resilience, and Energy Bill Benefits Using the REopt Model

Climate change, public health, and resilience to power outages are of critical concern to local governments, federal agencies, and the private sector, and are increasingly motivating investments in distributed energy resources (DERs). However, designing a solar-plus-storage system to co-optimize for climate, health, resilience, and energy bill benefits requires complex trade-offs. To address this need, the National Renewable Energy Laboratory has integrated climate and health impacts of grid-purchased electricity and on-site fuel consumption into the publicly-available REopt web tool and API - a techno-economic model that determines the cost-optimal DER system sizes and dispatch strategy. This presentation will provide an overview of the tool's methodology, datasets, and capabilities, including costing emissions into system sizing and dispatch and setting emissions reductions targets. Results of previous work will demonstrate the use of new emissions accounting capabilities by quantifying the impact of including climate and health costs on the optimal resilient microgrid configurations for a hospital, school, and warehouse across 14 U.S. cities.

climate↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation of Sustainable Power System Resilience in the Face of Severe Weather Conditions and Climate Changes: A Comprehensive Review of Current Advances

Natural disasters pose significant threats to power distribution systems, intensified by the increasing impacts of climate changes. Resilience-enhancement strategies are crucial in mitigating the resulting social and economic damages. Hence, this review paper presents a comprehensive exploration of weather management strategies, augmented by recent advancements in machine learning algorithms, to show a sustainable resilience assessment. By addressing the unique challenges posed by diverse weather conditions, we propose flexible and intelligent solutions to navigate disaster complications effectively. This proposition emphasizes sustainable practices that not only address immediate disaster complications, but also prioritize long-term resilience and adaptability. Furthermore, the focus extends to mitigation strategies and microgrid technologies adapted to distribution systems. Through statistical analysis and mathematical formulations, we highlight the critical role of these advancements in mitigating severe weather conditions and ensuring the system reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Energy Rationing in Islanded Electric Power Systems

Extreme weather events, many of which are climate change related, are occurring with increasing frequency and intensity and causing catastrophic outages. One of the major modern-day concerns of utilities is dealing with such extreme outages and consequently, its repercussions on the lives of people in society and social aspects. Traditionally, operators have been using rolling blackouts as a contingency plan to serve critical loads during such events when electricity supply is scarce. However, such blackouts practices are executed on a last-minute mandatory basis, depriving customers having low-capacity high priority loads (i.e. refrigeration, water, telecommunication, etc) that should also be serviced if at all possible. Historically, policymakers have often adopted quota-based regulatory actions or rationing for other commodities (such as gasoline, butter, sugar) to handle scarcity situations. Motivated from such quota based systems, our contribution presented in this work is an alternative transactive rationing mechanism that would provide some minimum level of service to all of the customers and serve the critical loads using market-based control during such scarcity-based contingencies. This is in contrast to the state-of-art TE mechanisms that allocate resources to customers solely based on their willingness-to-pay. The effectiveness of the proposed mechanism is demonstrated through simulation-based evaluation on two real-life use cases having feeder-level and microgrid-level configurations respectively. The simulation results clearly demonstrate the capability of the rationing scheme to serve customers’ high-priority loads through prolonged outages even during extreme scarcity scenarios.

42 ENGINEERING↗

Solid State Power Substation DC Node Optimization and Controller Hardware-In-The-Loop Demonstration

A solid state power substation (SSPS) node is a microgrid that integrates distributed energy resources and loads and injects/absorbs power to/from the SSPS distribution network. It is an essential building block of a futuristic distribution grid network. This paper presents the development and demonstration of optimization use cases of a SSPS DC node. By adopting multi-layer hierarchical control architecture and developing automatic device identification and dynamic optimization formulation algorithms, the SSPS DC node can perform plug-and-play resource integration and seamless transition of the optimized node operation under on and off grid condition without sophisticated algorithms, control mode changes, and user interactions. Four optimization use cases including economic dispatches with price signal changes, a sudden PV power drop, and a single directional meter and its associated costs with sending power back to the grid, and resiliency under a grid inverter trip condition were demonstrated through the real-time controller hardware-in-the-loop simulation.

Kim, Namwon↗