SEARCH · Search NASA
Results for “Mixed precision”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Analysis of Femtosecond Timing Noise and Stability in Microwave Components
To probe chemical dynamics, X-ray pump-probe experiments trigger a change in a sample with an optical laser pulse, followed by an X-ray probe. At the Linac Coherent Light Source, LCLS, timing differences between the optical pulse and x-ray probe have been observed with an accuracy as low as 50 femtoseconds. This sets a lower bound on the number of frames one can arrange over a time scale to recreate a 'movie' of the chemical reaction. The timing system is based on phase measurements from signals corresponding to the two laser pulses; these measurements are done by using a double-balanced mixer for detection. To increase the accuracy of the system, this paper studies parameters affecting phase detection systems based on mixers, such as signal input power, noise levels, temperature drift, and the effect these parameters have on components such as the mixers, splitters, amplifiers, and phase shifters. Noise data taken with a spectrum analyzer show that splitters based on ferrite cores perform with less noise than strip-line splitters. The data also shows that noise in specific mixers does not correspond with the changes in sensitivity per input power level. Temperature drift is seen to exist on a scale between 1 and 27 fs/{sup o}C for all of the components tested. Results show that any components using more metallic conductor tend to exhibit more noise as well as more temperature drift. The scale of these effects is large enough that specific care should be given when choosing components and designing the housing of high precision microwave mixing systems for use in detection systems such as the LCLS. With these improvements, the timing accuracy can be improved to lower than currently possible.
Studies of long-life pulsed CO2 laser with Pt/SnO2 catalyst
Closed-cycle CO2 laser testing with and without a catalyst and with and without CO addition indicate that a catalyst is necessary for long-term operation. Initial results indicate that CO addition with a catalyst may prove optimal, but a precise gas mix has not yet been determined. A long-term run of 10 to the 6th power pulses using 1.3% added CO and a 2% Pt on SnO2 catalyst yields an efficiency of about 95% of open-cycle steady-state power. A simple mathematical analysis yields results which may be sufficient for determining optimum running conditions. Future plans call for testing various catalysts in the laser and longer tests, 10 to the 7th power pulses. A Gas Chromatograph will be installed to measure gas species concentration and the analysis will be slightly modified to include neglected but possibly important parameters.
Recent Developments for Computational Fluid Dynamics on Unstructured Meshes Using GPUs
Explore the source record for details and available documents.
A Search for New Physics at the TeV Scale Via a Precise Measurement of the Weak Mixing Angle in Moller Scattering
Explore the source record for details and available documents.
Precision Measurement of the Weak Mixing Angle in Moller Scattering
Explore the source record for details and available documents.
PRECISE DETERMINATION OF THE WEAK MIXING ANGLE FROM A MEASUREMENT OF A(LR) IN E+ E- --> Z0.
Explore the source record for details and available documents.
The First Determination of the Proton's Weak Charge Through Parity-Violating Asymmetry Measurements in Elastic e + p and e + Al Scattering
The Q_weak experiment at Jefferson Laboratory will make a 4% measurement of the proton's weak charge, Q^p_W, by measuring the parity-violating asymmetry in elastic electron-proton scattering at low momentum transfer, Q^2 = 0.025 GeV^2. This asymmetry is proportional to the weak charge of the proton and can be related to the weak mixing angle, sin^2 Theta_W, a parameter in the Standard Model. Q_weak will measure the weak mixing angle precisely to 0.3%, challenging predictions of the Standard Model and probing certain types of new physics up to the TeV scale.
Chemical ionization tandem mass spectrometer for the in situ measurement of methyl hydrogen peroxide
A new approach for measuring gas-phase methyl hydrogen peroxide [(MHP) CH{sub 3}OOH] utilizing chemical ionization mass spectrometry is presented. Tandem mass spectrometry is used to avoid mass interferences that hindered previous attempts to measure atmospheric CH{sub 3}OOH with CF{sub 3}O{sup -} clustering chemistry. CH{sub 3}OOH has been successfully measured in situ using this technique during both airborne and ground-based campaigns. The accuracy and precision for the MHP measurement are a function of water vapor mixing ratio. Typical precision at 500 pptv MHP and 100 ppmv H{sub 2}O is {+-}80 pptv (2 sigma) for a 1 s integration period. The accuracy at 100 ppmv H{sub 2}O is estimated to be better than {+-}40%. Chemical ionization tandem mass spectrometry shows considerable promise for the determination of in situ atmospheric trace gas mixing ratios where isobaric compounds or mass interferences impede accurate measurements.
Metrics to quantify the importance of mixing state for CCN activity
It is commonly assumed that models are more prone to errors in predicted cloud condensation nuclei (CCN) concentrations when the aerosol populations are externally mixed. In this work we investigate this assumption by using the mixing state index ( χ ) proposed by Riemer and West (2013) to quantify the degree of external and internal mixing of aerosol populations. We combine this metric with particle-resolved model simulations to quantify error in CCN predictions when mixing state information is neglected, exploring a range of scenarios that cover different conditions of aerosol aging. We show that mixing state information does indeed become unimportant for more internally mixed populations, more precisely for populations with χ larger than 75 %. For more externally mixed populations ( χ below 20 %) the relationship of χ and the error in CCN predictions is not unique and ranges from lower than -40 % to about 150 %, depending on the underlying aerosol population and the environmental supersaturation. We explain the reasons for this behavior with detailed process analyses.
Turbulent mixing in a precessing sphere
By numerically simulating turbulent flows at high Reynolds numbers in a precessing sphere, we propose a method to enhance the mixing of a fluid confined within a smooth cavity by its rotational motion alone. To precisely evaluate the mixing efficiency, we extend the quantification method proposed by Danckwerts [“The definition and measurement of some characteristics of mixtures,” Appl. Sci. Res. A 3, 279–296 (1952)] to the case in which only a finite number of fluid particle trajectories can be known. Our accurate numerical tracking of fluid particles in the flow, which is controlled by the Reynolds number (an indicator of the spin rate) and the Poincaré number (the precession rate), shows the following results. First, the mixing process on the time scale normalized by the spin period is independent of the Reynolds number as long as it is high enough for the flow to be developed turbulence. Second, fastest mixing is achieved under weak precession (Poincaré number ≈0.1); in such cases, perfect mixing requires only 10–15 spins of the container. Third, the power to sustain turbulence is a weakly increasing function of the Poincaré number, and the energy efficiency of the mixing is also maximized when the Poincaré number is about 0.1. Fourth, efficient mixing driven by the weak precession arises from the effective cooperation of complex large-scale flow and small-scale turbulence, which itself is sustained by the large-scale flow.
The St. Benedict Facility: Probing Fundamental Symmetries through Mixed Mirror $β$-Decays
Precise measurements of nuclear beta decays provide a unique insight into the Standard Model due to their connection to the electroweak interaction. These decays help constrain the unitarity or non-unitarity of the Cabibbo–Kobayashi–Maskawa (CKM) quark mixing matrix, and can uniquely probe the existence of exotic scalar or tensor currents. Of these decays, superallowed mixed mirror transitions have been the least well-studied, in part due to the absence of data on their Fermi to Gamow-Teller mixing ratios ($ρ$). At the Nuclear Science Laboratory (NSL) at the University of Notre Dame, the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is being constructed to determine the ρ for various mirror decays via a measurement of the beta–neutrino angular correlation parameter ($α_{βν}$) to a relative precision of 0.5%. In this work, we present an overview of the St. Benedict facility and the impact it will have on various Beyond the Standard Model studies, including an expanded sensitivity study of $ρ$ for various mirror nuclei accessible to the facility. A feasibility evaluation is also presented that indicates the measurement goals for many mirror nuclei, which are currently attainable in a week of radioactive beam delivery at the NSL.
GEER Status Update
History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.
Quick mixing of epoxy components
Two materials are mixed quickly, thoroughly, and in precise proportion by disposable cartridge. Cartridge mixes components of fast-curing epoxy resins, with no mess, just before they are used. It could also be used in industry and home for caulking, sealing, and patching. Materials to be mixed are initially isolated by cylinder wall within cartridge. Cylinder has vanes, with holes in them, at one end and handle at opposite end. When handle is pulled, grooves on shaft rotate cylinder so that vanes rotate to extrude material A uniformly into material B.
Medium-Energy Antiproton Physics with the Antiproton Annihilation Spectrometer (TApAS*) at Fermilab
We propose to assemble a cost-effective, yet powerful, solenoidal magnetic spectrometer for antiproton-annihilation events and use it at the Fermilab Antiproton Accumulator to measure the charm production cross section, study rare hyperon decays, search for hyperon CP asymmetry, and precisely measure the properties of several charmonium and nearby states. Should the charm production cross section be as large as some have proposed, we will also be able to measure D{sup 0}-{bar D}{sup 0} mixing with high precision and discover (or sensitively limit) charm CP violation. The experiment will be carried out by an international collaboration, with installation occurring during the accelerator downtime following the completion of the Tevatron run, and with funding largely from university research grants. The experiment will require some four years of running time. As possibly the sole hadron experiment in progress at Fermilab during that time, it will play an important role in maintaining a broad particle-physics program at Fermilab and in the U.S.
Precise determination of lattice phase shifts and mixing angles
Not Available
New 13 C(α,n) 16 O Cross Section with Implications for Neutrino Mixing and Geoneutrino Measurements
Precise antineutrino measurements are very sensitive to proper background characterization. Here, we present an improved measurement of the 13 C(α,n) 16 O reaction cross section which constitutes significant background for large v¯ detectors. We greatly improve the precision and accuracy by utilizing a setup that is sensitive to the neutron energies while making measurements of the excited state transitions via secondary γ-ray detection. Our results shows a 54% reduction in the background contributions from the 16 O(3–, 6.13 MeV) state used in the KamLAND analysis.
Coulomb excitation of a {sup 242}Am isomeric target : E2, E3 strengths, rotational alignment, and collective enhancement.
A 98% pure {sup 242m}Am (K=5{sup -}, t{sub 1/2} = 141 years) isomeric target was Coulomb excited with a 170.5-MeV {sup 40}Ar beam. The selectivity of Coulomb excitation, coupled with the sensitivity of Gammasphere plus CHICO, was sufficient to identify 46 new states up to spin 18 {h_bar} in at least four rotational bands; 11 of these new states lie in the isomer band, 13 in a previously unknown yrast K{sup {pi}} = 6{sup -} rotational band, and 13 in a band tentatively identified as the predicted yrast K{sup {pi}} = 5{sup +} band. The rotational bands based on the K{sup {pi}} = 5{sup -} isomer and the 6{sup -} bandhead were populated by Coulomb excitation with unexpectedly equal cross sections. The {gamma}-ray yields are reproduced by Coulomb excitation calculations using a two-particle plus rotor model (PRM), implying nearly complete {Delta}K = 1 mixing of the two almost-degenerate rotational bands, but recovering the Alaga rule for the unperturbed states. The degeneracy of the 5{sup -} and 6{sup -} bands allows for precise determination of the mixing interaction strength V, which approaches the strong-mixing limit; this agrees with the 50% attenuation of the Coriolis matrix element assumed in the model calculations. The fractional admixture of the I{sub K}{sup {pi}} = 6{sub 6{sup -}} state in the nominal 6{sub 5{sup -}} isomer band state is measured within the PRM as 45.6{sub -1.1}{sup +0.3}%. The E2 and M1 strengths coupling the 5{sup -} and 6{sup -} bands are enhanced significantly by the mixing, while E1 and E2 couplings to other low-K bands are not measurably enhanced. The yields of the 5{sup +} band are reproduced by an E3 strength of {approx}15 W.u., competitive with the interband E2 strength. Alignments of the identified two-particle Nilsson states in {sup 242}Am are compared with the single-particle alignments in {sup 241}Am.