Deletion of Re -citrate synthase allows for analysis of contributions of tricarboxylic acid cycle directionality to the growth of Heliomicrobium modesticaldum

ABSTRACT Heliomicrobium modesticaldum,a phototrophic member of the phylum Firmicutes and family Clostridiales, possesses most of the enzymes specific to the reductive tricarboxylic acid (rTCA) cycle, except for the key enzyme, ATP-citrate lyase. It is thought to utilize a split TCA cycle when growing on pyruvate as a carbon source, in which the oxidative TCA (oTCA) direction generates most of the 2-ketoglutarate, but some can be produced in the reductive direction. Although a typicalSi-citrate synthase gene is not found in the genome, it was suggested that gene HM1_2993, annotated as homocitrate synthase, actually encodesRe-citrate synthase, which would function as the initial enzyme of the oTCA cycle. We deleted this gene to test this hypothesis and, if true, see what effect severing access to the oTCA cycle would have on this organism. The endogenous CRISPR-Cas system was used to replace the open reading frame with a selectable marker. The deletion mutants could grow on pyruvate but were unable to grow phototrophically on acetate + CO 2 as carbon source. Growth on acetate could be rescued by the addition of different electron sources (formate or ascorbate), suggesting that the oTCA cycle is used to oxidize acetate to generate electrons required to drive the carboxylation of acetyl-CoA. The deletion mutants were capable of growing in acetate minimal media without additional organic supplements beyond formate, demonstrating that the rTCA cycle can be employed to support sufficient 2-ketoglutarate production in this organism, unlike citrate synthase mutants in several chemoheterotrophic organisms utilizing the oTCA cycle. IMPORTANCE Heliobacteria are a unique group of phototrophic bacteria that are obligate anaerobes and possess a rudimentary system to use light as a source of energy. They do not make oxygen or fix carbon dioxide. Here, we explore their fundamental carbon metabolism to understand the role and operation of the central TCA cycle. This work shows both the role and operation of this cycle under different growth modes and explains how these organisms can obtain electrons to drive their biosynthetic metabolism. This foundational knowledge will be crucial in the future when attempts are made to use this organism as a platform for oxygen-sensitive synthesis of compounds in an anaerobe that can use light as its energy source.

Biotechnology & Applied Microbiology↗

Comparison of experimental and theoretical thermal fatigue lives for five nickel-base alloys.

Alloys investigated were Nimonic 90, IN 100, coated IN 100, B 1900, coated B 1900, MAR M200, and MAR M200DS (directionally solidified). Maximum temperatures ranged from 770 to 1120 C. Specimen geometries included tapered disks, double-edged wedges, and cambered airfoils. The disks and wedges were heated and cooled in fluidized beds. The airfoil specimens were heated by a Mach 1 natural gas burner and rapid-air cooled, with and without spanwise loading. Life calculations included two distinct failure modes: conventional low-cycle fatigue and cyclic creep. The complete life calculation system included the calculation of transient temperature distributions, thermal strains, stresses, creep damage, fatigue damage, and finally cycles to first crack. Calculated lives were within a factor of two for 76 of the 86 data points analyzed.

Spera, D. A.↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the Atmosphere Explorer, hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested at NASA to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Atmosphere Explorer spacecraft (AE's C, D, and E). The diaphragms will be used for positive propellant expulsion and spacecraft center of mass (c.m.) control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 10 psid during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft c.m. control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the atmosphere explorer hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Explorer spacecraft. The diaphragms will be used for positive propellant expulsion and spacecraft center of mass control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 7 N/sq cm during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft center of mass control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

Solar-powered Rankine heat pump for heating and cooling

The design, operation and performance of a familyy of solar heating and cooling systems are discussed. The systems feature a reversible heat pump operating with R-11 as the working fluid and using a motor-driven centrifugal compressor. In the cooling mode, solar energy provides the heat source for a Rankine power loop. The system is operational with heat source temperatures ranging from 155 to 220 F; the estimated coefficient of performance is 0.7. In the heating mode, the vapor-cycle heat pump processes solar energy collected at low temperatures (40 to 80 F). The speed of the compressor can be adjusted so that the heat pump capacity matches the load, allowing a seasonal coefficient of performance of about 8 to be attained.

Rousseau, J.↗

Some practical observations on the accelerated testing of Nickel-Cadmium Cells

A large scale test of 6.0 Ah Nickel-Cadmium Cells conducted at the Naval Weapons Support Center, Crane, Indiana has demonstrated a methodology for predicting battery life based on failure data from cells cycled in an accelerated mode. After examining eight variables used to accelerate failure, it was determined that temperature and depth of discharge were the most reliable and efficient parameters for use in accelerating failure and for predicting life.

Mcdermott, P. P.↗

Frequency shifts of high frequency p-modes

Frequency shifts of high frequency p-modes during the solar cycle are calculated for a non-magnetic polytrope convection zone model. An isothermal chromospheric atmosphere threaded by a uniform horizontal magnetic field is correlated to this model. The relevant observations of such frequency changes are discussed. The calculated simultaneous changes in the field strength and chromospheric temperature result in the frequency shifts that are similar to those of the observations.

Jain, Rekha↗

Thermal Conductivity and Thermal Gradient Cyclic Behavior of Refractory Silicate Coatings on SiC/SiC Ceramic Matrix Composites

Plasma-sprayed mullite and BSAS coatings have been developed to protect SiC/SiC ceramic matrix composites from high temperature environmental attack. In this study, thermal conductivity and thermal barrier functions of these coating systems are evaluated using a laser high-heat-flux test rig. The effects of water vapor on coating thermal conductivity and durability are studied by using alternating furnace and laser thermal gradient cyclic tests. The influence of laser high thermal-gradient cycling on coating failure modes is also investigated.

Zhu, Dongming↗

Subsurface Stress Fields in FCC Single Crystal Anisotropic Contacts

Single crystal superalloy turbine blades used in high pressure turbomachinery are subject to conditions of high temperature, triaxial steady and alternating stresses, fretting stresses in the blade attachment and damper contact locations, and exposure to high-pressure hydrogen. The blades are also subjected to extreme variations in temperature during start-up and shutdown transients. The most prevalent high cycle fatigue (HCF) failure modes observed in these blades during operation include crystallographic crack initiation/propagation on octahedral planes, and non-crystallographic initiation with crystallographic growth. Numerous cases of crack initiation and crack propagation at the blade leading edge tip, blade attachment regions, and damper contact locations have been documented. Understanding crack initiation/propagation under mixed-mode loading conditions is critical for establishing a systematic procedure for evaluating HCF life of single crystal turbine blades. This paper presents analytical and numerical techniques for evaluating two and three dimensional subsurface stress fields in anisotropic contacts. The subsurface stress results are required for evaluating contact fatigue life at damper contacts and dovetail attachment regions in single crystal nickel-base superalloy turbine blades. An analytical procedure is presented for evaluating the subsurface stresses in the elastic half-space, based on the adaptation of a stress function method outlined by Lekhnitskii. Numerical results are presented for cylindrical and spherical anisotropic contacts, using finite element analysis (FEA). Effects of crystal orientation on stress response and fatigue life are examined. Obtaining accurate subsurface stress results for anisotropic single crystal contact problems require extremely refined three-dimensional (3-D) finite element grids, especially in the edge of contact region. Obtaining resolved shear stresses (RSS) on the principal slip planes also involves considerable post-processing work. For these reasons it is very advantageous to develop analytical solution schemes for subsurface stresses, whenever possible.

Arakere, Nagaraj K.↗

Alternative Computational Approaches for Probalistic Fatigue Analysis

The feasibility is discussed for alternative methods of direct Monte Carlo simulation for failure probability computations. First and second order reliability methods are used for fatigue crack growth and low cycle fatigue structural failure modes to illustrate typical problems.

fatigue analysis failure models simulation↗

Static and Switching Characteristics of a 4H-SiC Based BJT to 200 C

Static curves and resistive load switching characteristics of a 600 V, 4 A rated, SiC-based NPN bipolar power transistor (BJT) were observed at selected temperatures from 23 to 200 C. All testing was done in a pulse mode at low duty cycle (approx. 0.1 percent). Turn-on was driven by an adjustable base current pulse and turn-off was accelerated by a negative base voltage pulse of either 7 or 0.6 V. Switching observations were done at base drive currents (I(sub B)) up to 400 mA and collector currents (I(sub C)) up to 4 A, using a 100 OMEGA non-inductive load. At I(sub B) = 400 mA and I(sub C) = 4 A, turn-on times typically varied from 81 to 97 ns, over temperatures from 23 to 200 C. As expected, lowering the base drive greatly extended the turn-on time. Similarly, decreasing the load current to I(sub C) = 1 A with I(sub B) = 400 mA produced turn-on times as short as 30 ns. Over the 23 to 200 C range, with I(sub B) = 400 mA and I(sub C) = 4 A, turn-off times were in the range of 61 to 77 ns with the 7 V sweep-out and 130 to 150 ns with the 0.6 V sweep-out. At a fixed temperature and I(sub C), the turn-off time decreased slightly with decreasing I(sub B), for I(sub B) sufficient to still provide full turn-on. The ratio of conduction to switching losses is estimated, based on the observed I(sub C) transition times and static curves. An estimate at 200 kHz and a 50 percent duty cycle shows that under practicable conditions the two losses can be comparable. Hence the evidence obtained does not support the occasionally voiced concern of necessarily unacceptably high conduction losses in SiC-based BJTs.

Niedra, Janis M.↗

Switching Characteristics of a 4H-SiC Based Bipolar Junction Transistor to 200 C

Static curves and resistive load switching characteristics of a 600 V, 4 A rated, SiC-based NPN bipolar power transistor (BJT) were observed at selected temperatures from room to 200 C. All testing was done in a pulse mode at low duty cycle (approx.0.1 percent). Turn-on was driven by an adjustable base current pulse and turn-off was accelerated by a negative base voltage pulse of 7 V. These base drive signals were implemented by 850 V, gated power pulsers, having rise-times of roughly 10 ns, or less. Base charge sweep-out with a 7 V negative pulse did not produce the large reverse base current pulse seen in a comparably rated Si-based BJT. This may be due to a very low charge storage time. The decay of the collector current was more linear than its exponential-like rise. Switching observations were done at base drive currents (I(sub B)) up to 400 mA and collector currents (I(sub C)) up to 4 A, using a 100 Omega non-inductive load. At I(sub B) = 400 mA and I(sub C) = 4 A, turn-on times typically varied from 80 to 94 ns, over temperatures from 23 to 200 C. As expected, lowering the base drive greatly extended the turn-on time. Similarly, decreasing the load current to I(sub C) = 1 A with I(sub B) = 400 mA produced turn-on times as short as 34 ns. Over the 23 to 200 C range, with I(sub B) = 400 mA and I(sub C) = 4 A, turn-off times were in the range of 72 to 84 ns with the 7 V sweep-out.

Niedra, Janis M.↗

Building a Database for a Quantitative Model

A database can greatly benefit a quantitative analysis. The defining characteristic of a quantitative risk, or reliability, model is the use of failure estimate data. Models can easily contain a thousand Basic Events, relying on hundreds of individual data sources. Obviously, entering so much data by hand will eventually lead to errors. Not so obviously entering data this way does not aid linking the Basic Events to the data sources. The best way to organize large amounts of data on a computer is with a database. But a model does not require a large, enterprise-level database with dedicated developers and administrators. A database built in Excel can be quite sufficient. A simple spreadsheet database can link every Basic Event to the individual data source selected for them. This database can also contain the manipulations appropriate for how the data is used in the model. These manipulations include stressing factors based on use and maintenance cycles, dormancy, unique failure modes, the modeling of multiple items as a single "Super component" Basic Event, and Bayesian Updating based on flight and testing experience. A simple, unique metadata field in both the model and database provides a link from any Basic Event in the model to its data source and all relevant calculations. The credibility for the entire model often rests on the credibility and traceability of the data.

Kahn, C. Joseph↗

Air Source Heat Pumps in Very Cold Climates

Air source heat pumps (ASHPs) in heating mode use a refrigeration cycle to remove heat from the outside air and transfer it into a building. Therefore, ASHPs have the potential to save energy compared to conventional heat sources that create the heat as opposed to transferring it from outside. Many cold climate ASHPs available on the market today can operate at outside temperatures of -25 degrees C (-13 degrees F) or even lower. As a result of technological advances and other factors, there is growing interest in ASHPs in cold climates, including very cold regions such as Alaska. However, guidance on the selection, installation, and operation of ASHPs in these very cold climates is limited, as significant data gaps exist regarding the performance of ASHPs in very cold environments. To address these data gaps and guide future innovations, our research team has studied the field performance of several ASHP installations in Alaska and done lab evaluations of several ASHP models using a cold chamber. While a cold chamber cannot fully reflect field conditions, it allowed for changing one variable at a time and gaining additional understanding of the behavior of ASHPs that would be difficult to gain from field studies only. This study focused on two main variables: the temperature in the chamber (representing the outdoor temperature) and the level of thermal loading of the ASHP. The results from the field as well as the lab show that ASHPs can operate with relatively high efficiency even in very cold climates if used in appropriate situations and in an appropriate way. It was found that not only the outside temperature, but also the level of thermal loading is a significant factor affecting the ASHP efficiency and needs to be carefully considered when sizing and operating ASHPs in very cold climates.

air source heat pump↗

Evaluation of oxidation resistant nonmetallic materials at 1204 C (2200 F) in a Mach 1 burner

Specimens of 23 oxidation resistant, nonmetallic, refractory materials were systematically exposed in a high gas velocity burner to simulate a turbine engine environment. Isothermal and cyclic tests were conducted at a specimen temperature of 2200F which resulted from exposure to Mach 1 or Mach 0.5 hot gas streams. Specimen behavior was judged on the basis of failure mode, appearance, and weight change. SiC and Si3N4 exhibited the most promising behavior surviving all exposures including Mach 1 for 120 cycles (10 hr). Major failure modes identified for other materials were thermal shock, thermal fatigue, and mechanical failure due to gas loading.

Sanders, W. A.↗

Unsteady Aerodynamic Response of a Linear Cascade of Airfoils in Separated Flow

The overall objective of this research program was to investigate methods to modify the leading edge separation region, which could lead to an improvement in aeroelastic stability of advanced airfoil designs. The airfoil section used is representative of current low aspect ratio fan blade tip sections. The experimental potion of this study investigated separated zone boundary layer from removal through suction slots. Suction applied to a cavity in the vicinity of the separation onset point was found to be the most effective location. The computational study looked into the influence of front camber on flutter stability. To assess the influence of the change in airfoil shape on stability the work-per-cycle was evaluated for torsion mode oscillations. It was shown that the front camberline shape can be an important factor for stabilizing the predicted work-per-cycle and reducing the predicted extent of the separation zone. In addition, data analysis procedures are discussed for reducing data acquired in experiments that involve periodic unsteady data. This work was conducted in support of experiments being conducted in the NASA Glenn Research Center Transonic Flutter Cascade. The spectral block averaging method is presented. This method is shown to be able to account for variations in airfoil oscillation frequency that can occur in experiments that force oscillate the airfoils to simulate flutter.

Capece, Vincent R.↗