Search NASA⌕ Search

SEARCH · Search NASA

Results for “Models, Anatomic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advanced interdisciplinary technologies

The following topics are presented in view graph form: (1) breakthrough trust (space research and technology assessment); (2) bionics (technology derivatives from biological systems); (3) biodynamics (modeling of human biomechanical performance based on anatomical data); and (4) tethered atmospheric research probes.

Anderson, John L.↗

Virtual Reality Simulation of the Effects of Microgravity in Gastrointestinal Physiology

The ultimate goal of this research is to create an anatomically accurate three-dimensional (3D) simulation model of the effects of microgravity in gastrointestinal physiology and to explore the role that such changes may have in the pharmacokinetics of drugs given to the space crews for prevention or therapy. To accomplish this goal the specific aims of this research are: 1) To generate a complete 3-D reconstructions of the human GastroIntestinal (GI) tract of the male and female Visible Humans. 2) To develop and implement time-dependent computer algorithms to simulate the GI motility using the above 3-D reconstruction.

Compadre, Cesar M.↗

Paralysis recovery in humans and model systems

Considerable evidence now demonstrates that extensive functional and anatomical reorganization following spinal cord injury occurs in centers of the brain that have some input into spinal motor pools. This is very encouraging, given the accumulating evidence that new connections formed across spinal lesions may not be initially functionally useful. The second area of advancement in the field of paralysis recovery is in the development of effective interventions to counter axonal growth inhibition. A third area of significant progress is the development of robotic devices to quantify the performance level of motor tasks following spinal cord injury and to 'teach' the spinal cord to step and stand. Advances are being made with robotic devices for mice, rats and humans.

Review↗

Effects of spaceflight and simulated weightlessness on longitudinal bone growth

Indirect measurements have suggested that spaceflight impairs bone elongation in rats. To test this possibility, our laboratory measured, by the fluorochrome labeling technique, bone elongation that occurred during a spaceflight experiment. The longitudinal growth rate (LGR) in the tibia of rats in spaceflight experiments (Physiological Space Experiments 1, 3, and 4 and Physiological-Anatomical Rodent Experiment 3) and in two models of skeletal unloading (hind-limb elevation and unilateral sciatic neurotomy) were calculated. The effects of an 11 day spaceflight on gene expression of cartilage matrix proteins in rat growth plates were also determined by northern analysis and are reported for the first time in this study. Measurements of longitudinal growth indicate that skeletal unloading generally did not affect LGR, regardless of age, strain, gender, duration of unloading, or method of unloading. There was, however, one exception with 34% suppression in LGR detected in slow-growing, ovariectomized rats skeletally unloaded for 8 days by hind-limb elevation. This detection of reduced LGR by hind-limb elevation is consistent with changes in steady-state mRNA levels for type II collagen (-33%) and for aggrecan (-53%) that were detected in rats unloaded by an 11 day spaceflight. The changes detected in gene expression raise concern that spaceflight may result in changes in the composition of extracellular matrix, which could have a negative impact on conversion of growth-plate cartilage into normal cancellous bone by endochondral ossification.

manned↗

NASA Occupant Protection Standards Development

Historically, spacecraft landing systems have been tested with human volunteers, because analytical methods for estimating injury risk were insufficient. These tests were conducted with flight-like suits and seats to verify the safety of the landing systems. Currently, NASA uses the Brinkley Dynamic Response Index to estimate injury risk, although applying it to the NASA environment has drawbacks: (1) Does not indicate severity or anatomical location of injury (2) Unclear if model applies to NASA applications. Because of these limitations, a new validated, analytical approach was desired. Leveraging off of the current state of the art in automotive safety and racing, a new approach was developed. The approach has several aspects: (1) Define the acceptable level of injury risk by injury severity (2) Determine the appropriate human surrogate for testing and modeling (3) Mine existing human injury data to determine appropriate Injury Assessment Reference Values (IARV). (4) Rigorously Validate the IARVs with sub-injurious human testing (5) Use validated IARVs to update standards and vehicle requirement

Somers, Jeffrey↗

SU-F-J-80: Deformable Image Registration for Residual Organ Motion Estimation in Respiratory Gated Treatments with Scanned Carbon Ion Beams

Purpose: At the Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy) C-ions respiratory gated treatments of patients with abdominal tumours started in 2014. In these cases, the therapeutic dose is delivered around end-exhale. We propose the use of a respiratory motion model to evaluate residual tumour motion. Such a model requires motion fields obtained from deformable image registration (DIR) between 4DCT phases, estimating anatomical motion through interpolation. The aim of this work is to identify the optimal DIR technique to be integrated in the modeling pipeline. Methods: We used 4DCT datasets from 4 patients to test 4 DIR algorithms: Bspline, demons, log-domain and symmetric log domain diffeomorphic demons. We evaluate DIR performance in terms of registration accuracy (RMSE between registered images) and anatomical consistency of the motion field (Jacobian) when registering end-inhale to end-exhale. We subsequently employed the model to estimate the tumour trajectory within the ideal gating window. Results: Within the liver contour, the RMSE is in the range 31–46 HU for the best performing algorithm (Bspline) and 43–145 HU for the worst one (demons). The Jacobians featured zero negative voxels (which indicate singularities in the motion field) for the Bspline fields in 3 of 4 patients, whereas diffeomorphic demons fields showed a non-null number of negative voxels in every case. GTV motion in the gating window measured less than 7 mm for every patient, displaying a predominant superior-inferior (SI) component. Conclusion: The Bspline algorithm allows for acceptable DIR results in the abdominal region, exhibiting the property of anatomical consistency of the computed field. Computed trajectories are in agreement with clinical expectations (small and prevalent SI displacements), since patients lie wearing semi-rigid immobilizing masks. In future, the model could be used for retrospective estimation of organ motion during treatment, as guided by the breathing surrogate signal.

60 APPLIED LIFE SCIENCES↗

Atrial Model Development and Prototype Simulations: CRADA Final Report on Tasks 3 and 4

The goal of this CRADA was to develop essential tools needed to simulate human atrial electrophysiology in 3-dimensions using an anatomical image-based anatomy and physiologically detailed human cellular model. The atria were modeled as anisotropic, representing the preferentially longitudinal electrical coupling between myocytes. Across the entire anatomy, cellular electrophysiology was heterogeneous, with left and right atrial myocytes defined differently. Left and right cell types for the “control” case of sinus rhythm (SR) was compared with remodeled electrophysiology and calcium cycling characteristics of chronic atrial fibrillation (cAF). The effects of Isoproterenol (ISO), a beta-adrenergic agonist that represents the functional consequences of PKA phosphorylation of various ion channels and transporters, was also simulated in SR and cAF to represent atrial activity under physical or emotional stress. Results and findings from Tasks 3 & 4 are described. Tasks 3 and 4 are, respectively: Input parameters prepared for a Cardioid simulation; Report including recommendations for additional scenario development and post-processing analytic strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Minipigs as a Model to Study Separate and Combined Effects of Space Radiation and Altered Gravity on Cardiovascular disease, Spaceflight-Associated Neuro-Ocular Syndrome (SANS), and Central Nervous System (CNS) effects

Minipigs are a well-characterized animal model used to study thecardiovascular system, metabolism, bone, gastrointestinal tract,pancreas, liver, kidney, lung, immune system, central nervous system(white matter) etc. Due to their anatomical, physiological, andbiochemical similarities to humans, minipigs are considered atranslational model in biomedical research and development. Also, their large size and cognitive abilities allow collection of supplementary information regarding the central nervous system(BMed) and Spaceflight-Associated Neuro-Ocular Syndrome (SANS) risk.

Janapriya Saha↗

Predictive models enhance feedstock quality of corn stover via air classification

Feedstock heterogeneity is a fundamental obstacle to cost-competitive biobased products. Agricultural products like corn stover have anatomical components that vary in their chemical composition, mechanical properties, structure, and response to chemical and biological treatments. A technique that can enrich streams in select anatomical fractions would allow a tailored deconstruction approach to increase overall process efficiency. Air classification can be leveraged for such refining, however, fundamental characterization and understanding of the particle properties that underly the physics of air classification are only modestly documented. Here, we determine fundamental particle properties including mass-to-area ratio, drag coefficient, and partition velocity that describe how anatomical tissues of corn stover behave during air classification. In this work, mass-to-area ratios of anatomical tissues vary by nearly two orders of magnitude from 2.3 mg/mm 2 for cob to 0.04 mg/mm 2 for leaf. Drag coefficients of longer, fibrous materials (i.e., rind, husk, and sheath) are shown to correlate with particle area (p-value < 0.001) whereas granular tissues (i.e., cob, pith, and leaf) correlate better with mass-to-area ratio (p-values < 0.001). When compared to experimental observations, a simulated two-stage air classification and size reduction scenario predicts the overall partitioning of anatomical tissues within 15% for pith, husk, rind, and cob tissues. The model predicts an air-classified fraction preferentially enriched in cob (purity = 20%), rind (purity = 74%), and pith (purity = 4.5%) with a mass yield of 47%. Empirical relations for these properties can be used to predict the partitioning of corn stover during air classification based on anatomical type and size.

09 BIOMASS FUELS↗

Lumped Parameter Models of the Central Nervous System for VIIP Research

INTRODUCTION: Current long-duration missions to the International Space Station and future exploration-class missions beyond low-Earth orbit, such as to Mars and asteroids, expose astronauts to increased risk of Visual Impairment and Intracranial Pressure (VIIP) syndrome [1]. It has been hypothesized that the headward shift of cerebral spinal fluid (CSF) and blood in microgravity may cause significant elevation of intracranial pressure (ICP), which in turn induces VIIP syndrome through biomechanical pathways [1, 2]. However, there is insufficient evidence to confirm this hypothesis. In this light, we are developing lumped-parameter models of fluid transport in the central nervous system (CNS) as a means to simulate the influence of microgravity on ICP. The CNS models will also be used in concert with the lumped parameter and finite element models of the eye described in the realted IWS abstracts submitted by Nelson et al., Feola et al. and Ethier et al. METHODS: We have developed a nine compartment CNS model (Figure 1) capable of both time-dependent and steady state fluid transport simulations, based on the works of Stevens et al. [3]. The breakdown of compartments within the model includes: vascular (3), CSF (2), brain (1) and extracranial (3). The boundary pressure in the Central Arteries [A] node is prescribed using an oscillating pressure function PA(t) simulating the carotid pulsatile pressure wave as developed by Linninger et al. [4]. For each time step, pressures are integrated through time using an adaptive-timestep 4th and 5th order Runga-Kutta solver. Once pressures are found, constitutive equations are used to solve for flowrates (Q) between each compartment. In addition to fluid flow between the different compartments, compliance (C) interactions between neighboring compartments are represented. We are also developing a second CNS model based on the works of Linninger et al. [4] which takes a more granular approach to represent the interactions of the intracranial and spinal compartments with the inclusion of arteries, arterioles, capillaries, venules, veins, venous sinus, and ventricles. The flow through the arteries, veins and CSF compartments are governed by continuity, momentum and distensibility balance equations. Furthermore, unlike the Stevens et al. approach, the Monro-Kellie doctrine of constant cranial volume and the bi-phasic nature of the brain parenchyma are implemented. These features appear to be more consistent with the physiologic and anatomical behavior of the CNS, and follow a modeling philosophy similar to the lumped parameter eye model that is intended to be integrated with the CNS model. However, Linninger’s approach has never been implemented to include hydrostatic gradient and microgravity simulation capabilities. Therefore, we aim at implement this modeling approach for spaceflight simulations and assess its overall applicability to VIIP research. OBJECTIVES: We will present verification and validation test results for both models, as well as head-to-head comparison to explore their strengths and limitations with respect to mathematical implementation and physiological significance for VIIP research. In doing so, we hope to provide some guidance to the HRP research community on how to appropriately leverage lumped parameter models for space biomedical research.

Vera, J.↗

Using individual patient anatomy to predict protocol compliance for prostate intensity-modulated radiotherapy

If a prostate intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) plan has protocol violations, it is often a challenge knowing whether this is due to unfavorable anatomy or suboptimal planning. This study aimed to create a model to predict protocol violations based on patient anatomical variables and their potential relationship to target and organ at risk (OAR) end points in the setting of definitive, dose-escalated IMRT/VMAT prostate planning. Radiotherapy plans from 200 consecutive patients treated with definitive radiation for prostate cancer using IMRT or VMAT were analyzed. The first 100 patient plans (hypothesis-generating cohort) were examined to identify anatomical variables that predict for dosimetric outcome, in particular OAR end points. Variables that scored significance were further assessed for their ability to predict protocol violations using a Classification and Regression Tree (CART) analysis. These results were then validated in a second group of 100 patients (validation cohort). In the initial analysis of the hypothesis-generating cohort, percentage of rectum overlap in the planning target volume (PTV) (%OR) and percentage of bladder overlap in the PTV (%OB) were highlighted as significant predictors of rectal and bladder dosimetry. Lymph node treatment was also significant for bladder outcomes. For the validation cohort, CART analysis showed that %OR of < 6%, 6% to 9% and > 9% predicted a 13%, 63%, and 100% rate of rectal protocol violations respectively. For the bladder, %OB of < 9% vs > 9% is associated with 13% vs 88% rate of bladder constraint violations when lymph nodes were not treated. If nodal irradiation was delivered, plans with a %OB of < 9% had a 59% risk of violations. Percentage of rectum and bladder within the PTV can be used to identify individual plan potential to achieve dose-volume histogram (DVH) constraints. A model based on these factors could be used to reduce planning time, improve work flow, and strengthen plan quality and consistency.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.

60 APPLIED LIFE SCIENCES↗

Analysis of meiosis in Pristionchus pacificus reveals plasticity in homolog pairing and synapsis in the nematode lineage

Meiosis is conserved across eukaryotes yet varies in the details of its execution. Here we describe a new comparative model system for molecular analysis of meiosis, the nematode Pristionchus pacificus, a distant relative of the widely studied model organism Caenorhabditis elegans. P. pacificus shares many anatomical and other features that facilitate analysis of meiosis in C. elegans. However, while C. elegans has lost the meiosis-specific recombinase Dmc1 and evolved a recombination-independent mechanism to synapse its chromosomes, P. pacificus expresses both DMC-1 and RAD-51. We find that SPO-11 and DMC-1 are required for stable homolog pairing, synapsis, and crossover formation, while RAD-51 is dispensable for these key meiotic processes. RAD-51 and DMC-1 localize sequentially to chromosomes during meiotic prophase and show nonoverlapping functions. We also present a new genetic map for P. pacificus that reveals a crossover landscape very similar to that of C. elegans, despite marked divergence in the regulation of synapsis and crossing-over between these lineages.

59 BASIC BIOLOGICAL SCIENCES↗

Techno-Economic Case Study: Low-Temperature Conversion Performance Based on Isolated Anatomical Fractions of Corn Stover

This report summarizes analysis conducted to support a case study under the Feedstock Conversion Interface Consortium (FCIC) focused on techno-economic analysis (TEA) modeling to quantify the process yield and resulting process cost impacts for processing isolated anatomical fractions of corn stover through a low-temperature conversion (biochemical) pathway. It is hypothesized that different individual anatomical fractions of corn stover vary in both composition and recalcitrance, giving biorefineries options in whether and how to deal with fractionated or whole biomass feedstock. By quantifying the techno-economic impacts of this variability, we provide actionable information for end users to understand tradeoffs in conversion system yields and economics in considering feedstock processing decisions at the biorefinery gate. For this study, we worked with FCIC researchers to obtain data on the compositional analysis and conversion performance of whole corn stover alongside three individual anatomical fractions (cobs, husks, and stalks) across key steps of the biorefinery conversion process within FCIC’s research scope—pretreatment and enzymatic hydrolysis. This TEA screening assessment highlighted biorefinery economic trade-offs observed through this approach. Namely, relative to processing whole stover biomass, two of the three anatomical fractions for which composition/conversion data were available (cobs and husks) demonstrated the ability to achieve higher fuel yields and lower minimum fuel selling prices (MFSPs), while the third fraction (stalks) led to the opposite result, as a composite reflection of compositional differences and process convertibility.

cost impacts↗

SU-F-I-50: Finite Element-Based Deformable Image Registration of Lung and Heart

Purpose: Photodynamic therapy (PDT) is used after surgical resection to treat the microscopic disease for malignant pleural mesothelioma and to increase survival rates. Although accurate light delivery is imperative to PDT efficacy, the deformation of the pleural volume during the surgery impacts the delivered light dose. To facilitate treatment planning, we use a finite-element-based (FEM) deformable image registration to quantify the anatomical variation of lung and heart volumes between CT pre-(or post-) surgery and surface contours obtained during PDT using an infrared camera-based navigation system (NDI). Methods: NDI is used during PDT to obtain the information of the cumulative light fluence on every cavity surface point that is being treated. A wand, comprised of a modified endotrachial tube filled with Intralipid and an optical fiber inside the tube, is used to deliver the light during PDT. The position of the treatment is tracked using an attachment with nine reflective passive markers that are seen by the NDI system. Then, the position points are plotted as three-dimensional volume of the pleural cavity using Matlab and Meshlab. A series of computed tomography (CT) scans of the lungs and heart, in the same patient, are also acquired before and after the surgery. The NDI and CT contours are imported into COMSOL Multiphysics, where the FEM-based deformable image registration is obtained. The NDI and CT contours acquired during and post-PDT are considered as the reference, and the Pre-PDT CT contours are used as the target, which will be deformed. Results: Anatomical variation of the lung and heart volumes, taken at different times from different imaging devices, was determined by using our model. The resulting three-dimensional deformation map along x, y and z-axes was obtained. Conclusion: Our model fuses images acquired by different modalities and provides insights into the variation in anatomical structures over time.

60 APPLIED LIFE SCIENCES↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

A reduced order model to analytically infer atmospheric CO 2 concentration from stomatal and climate data

To address questions related to the acceleration or deceleration of the global hydrological cycle or links between the carbon and water cycles over land, reliable data for past climatic conditions based on proxies are required. In particular, the reconstruction of palaeoatmospheric CO 2 content (C a ) is needed to assist the separation of natural from anthropogenic C a variability and to explore phase relations between C a and air temperature T a time series. Both T a and C a are needed to fingerprint anthropogenic signatures in vapor pressure deficit, a major driver used to explain acceleration or deceleration phases in the global hydrological cycle. Current approaches to C a reconstruction rely on a robust inverse correlation between measured stomatal density in leaves (ν) of many plant taxa and C a . There are two methods that exploit this correlation: The first uses calibration curves obtained from extant species assumed to represent the fossil taxa, thereby restricting the suitable taxa to those existing today. The second is a hybrid eco-hydrological/physiological approach that determines C a with the aid of systems of equations based on quasi-instantaneous leaf-gas exchange theories and fossil stomatal data collected along with other measured leaf anatomical traits and parameters. In this contribution, a reduced order model (ROM) is proposed that derives C a from a single equation incorporating the aforementioned stomatal data, basic climate (e.g. temperature), estimated biochemical parameters of assimilation and isotope data. The usage of the ROM is then illustrated by applying it to isotopic and anatomical measurements from three extant species. The ROM derivation is based on a balance between the biochemical demand and atmospheric supply of CO 2 that leads to an explicit expression linking stomatal conductance to internal CO 2 concentration (C i ) and C a . The resulting expression of stomatal conductance from the carbon economy of the leaf is then equated to another expression derived from water vapor gas diffusion that includes anatomical traits. When combined with isotopic measurements for long-term C i /C a , C a can be analytically determined and is interpreted as the time-averaged C a that existed over the life-span of the leaf. Key advantages of the proposed ROM are: 1) the usage of isotopic data provides constraints on the reconstructed atmospheric CO 2 concentration from ν, 2) the analytical form of this approach permits direct links between parameter uncertainties and reconstructed C a , and 3) the time-scale mismatch between the application of instantaneous leaf-gas exchange expressions constrained with longer-term isotopic data is reconciled through averaging rules and sensitivity analysis. The latter point was rarely considered in prior reconstruction studies that combined models of leaf-gas exchange and isotopic data to reconstruct C a from ν. The proposed ROM is not without its limitations given the need to a priori assume a parameter related to the control on photosynthetic rate. Our work here further explores immanent constraints for the aforementioned photosynthetic parameter.

54 ENVIRONMENTAL SCIENCES↗

The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicing experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even for models of the same age and sex. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: This work provides a large cohort of highly detailed pediatric phantoms with 4D capabilities of varying age, height, and body mass. The population of phantoms will provide a vital tool with which to optimize 3D and 4D pediatric imaging devices and techniques in terms of image quality and radiation-absorbed dose.

60 APPLIED LIFE SCIENCES↗