Search NASASearch

SEARCH · Search NASA

Results for “Modulus Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

242 records · Page 8

Large Scale Granulator Development Designed to Process Reclaimed Feedstock for Sustainable Additive Manufacturing Applications

This CRADA between UT-Battelle, LLC (Contractor) and re:3D Inc. (Participant) aims to develop an affordable large-scale granulator system designed to process reclaimed plastic feedstock suitable for additive manufacturing applications. The 24-month project will focus on testing, prototyping, and optimizing a shredder/granulator system. This project also focuses on the processing steps (e.g. washing and sorting) that can convert waste plastics, like discarded water bottles, into flake/granules which can be 3D printed using re:3D’s Fused Granular Fabrication (FGF) 3D printers. If successful, this could enable more localized 3D printing using recycled plastics, reducing waste and feedstock costs.

Wang, Peter [Oak Ridge National Laboratory (ORNL),

Ultra-light antennas via charge programmed deposition additive manufacturing

Abstract The demand for lightweight antennas in 5 G/6 G communication, wearables, and aerospace applications is rapidly growing. However, standard manufacturing techniques are limited in structural complexity and easy integration of multiple material classes. Here we introduce charge programmed multi-material additive manufacturing platform, offering unparalleled flexibility in antenna design and the capability for rapid printing of intricate antenna structures that are unprecedented or necessitate a series of fabrication routes. Demonstrating its potential, we present a transmitarray antenna composed of an interconnected, multi-layered array of dielectric/conductive S-ring unit cells, reducing 94% mass of conventional antenna configurations. A fully printed circular polarized transmitarray system fed by a source and a Risley prism antenna system operating at 19 GHz both show close alignment between testing results and numerical simulations. This printing method establishes a universal platform, propelling discovery of new antenna designs and enabling data-driven design and optimizations where rapid production of antenna designs is crucial.

Science & Technology - Other Topics

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision

Progress Report on SFR Metallic Fuel Data Qualification

This report summarizes the progress of SFR metallic fuel qualification related activities, which are focused on providing quality assurance relevant information applicable to experiments irradiated during the Integral Fast Reactor (IFR) program. An overview of the metallic fuel performance data and the associated databases, including the EBR-II Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT Experimental Relational Database (TREXR) is included. The legacy data in the databases, including as-built, post-irradiation examination (PIE), operating parameters, and out-of-pile experiment post-test data are introduced. The SFR metallic fuel Quality Assurance Program Plan (QAPP) and its implementation to qualify these legacy data is described in detail. Important PIE data QA documents and the specifications of seven types of PIE measurements (contact profilometry, laser profilometry, neutron radiography, gamma scan, fission gas release fission gas chemistry, and metallography) are provided. Examples of the implementation of the QAPP to qualify each of those types of PIE data are provided.

Mo, Kun [Argonne National Laboratory (ANL), Argonn

Lagrange-Remap strategy for multi-material fluid-solid simulations using compressive limiters

In the present work, the Lagrange-Remap strategy proposed in [1] is extended to multi-material fluid-solid simulations. Both hypo-elastic and hyper-elastic material models are considered to describe the mechanical behavior of the solids. In practice, the deviatoric stress tensor (for hypo-elastic materials) and the left Cauchy-Green tensor (for isotropic hyper-elastic materials) are remapped, while the use of compressive limiters effectively reduces numerical diffusion during the remapping step. The simplicity of this diffuse interface approach is emphasized in the context of multi-material fluid-solid simulations. A series of Lagrange-Remap test cases, involving both solids and fluids, are conducted and compared with reference Lagrangian simulations, demonstrating the robustness and accuracy of the overall numerical strategy.

Compressive limiters

Flash Heating of a Hollow Rod to Determine Thermal Properties

In a nuclear reactor, prolonged exposure to high neutron flux levels can change material properties of reactor components. Due to the danger posed to personnel by highly radioactive components such as spent fuel, noncontact methods must be used to determine these properties. The objective of the current research is to test the viability of using a flash-heating method to determine the thermal diffusivity of a silicon carbide (SiC) tube, which could be used as cladding for a nuclear fuel rod. The flash-heating experiment was conducted at Oak Ridge National Laboratory and temperature results were analyzed as a two-Dimensional cross section which assumed axial symmetry. The model was fitted iteratively to the temperature measurements using nonlinear regression which required values for thermal diffusivity, Biot number and a term to determine the magnitude of the heat absorbed by the flash. The method could be expanded in the future to estimate the thermal diffusivity of spent nuclear fuel rods in an effort to increase the certainty of new reactor designs using precise thermal properties throughout the core life. A statistical analysis of the results of this work is provided as part of the analysis.

McMasters, Robert L [Virginia Military Institute,

Shear and combustion characterization of printable ammonium perchlorate composite propellant formulations

Seven formulations of ammonium perchlorate composite propellant (APCP) are developed and their properties relevant for successful additive manufacture are characterized. Extrusion in a custom-built 3D printing system and spindle viscometry are used to collect viscosity measurements of curing primary and non-curing secondary versions of the formulations. The formulations that behave similarly to a Bingham plastic, with apparent viscosities between 4 and 8 thousand Pa*s at 30 minutes post-mix, are determined to be most suitable for printing applications. Measurements of one material show a yield stress of 1 kPa. Ambient pressure burn rates of 2.0–2.9 mm/s were measured for the compositions tested. All measured burn rates were comparable to the lower end of typical burn rates for APCP. In conclusion, the results of the characterization demonstrate a propellant suitable for use in a 3D printing system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Tensorized Interior Radiative Heat Transfer for a Scalable and Calibrated Building Energy Simulator

Building energy simulation is a critical tool for developing and testing advanced control strategies, such as Reinforcement Learning (RL), to provide demand flexibility and affordable energy costs. The recently introduced Smart Buildings Control Suite (sbsim) provides a lightweight, scalable, and data-calibrated simulation environment based on a 2D finite-difference model. However, the initial model primarily focused on conductive and convective heat transfer, neglecting the significant impact of long-wave radiative heat exchange between interior surfaces. This paper presents a significant extension to the sbsim framework by incorporating a physically-grounded model for interior radiative heat transfer. Our primary contribution is the development and integration of a fully tensorized radiative heat transfer module, which preserves the computational efficiency and scalability of the original simulator. This was achieved by developing a pipeline for view factor calculation, including an algorithm to identify directly seeing surfaces within complex floor plans, and formulating the net radiation equations for efficient execution on modern hardware accelerators. We validate the numerical accuracy of our tensorized implementation by comparing its results against a traditional iterative approach, demonstrating identical outcomes. This enhancement increases the physical fidelity of sbsim, enabling more accurate training of RL agents for building energy optimization.

Ham, Sang woo

Electrode Erosion and Prefire Studies Towards Fusion Scale Pulsed Power

This study presents a comprehensive investigation of electrode erosion and discharge behavior in spark gap switches over long switching cycle lifetimes. Brass, copper–tungsten (CuW), and stainless steel electrodes are tested under controlled conditions to quantify material degradation, debris accumulation, and changes in breakdown voltage. High-resolution imaging and statistical analysis of spark channel locations and gap breakdown voltages reveal how surface evolution influences long-term performance and reliability. These results provide essential data for lifetime modeling and inform design strategies for pulsed power systems in emerging applications such as private sector fusion energy and large-scale facilities like Sandia’s Z Machine and proposed ZX upgrades, where high repetition reliability and predictable behavior are critical.

electrical breakdown

Robust Spectral Anomaly Detection in EELS Spectral Images via 3D Convolutional Variational Autoencoders

Abstract A 3D Convolutional Variational Autoencoder (3D‐CVAE) is introduced for automated anomaly detection in electron energy‐loss spectroscopy spectrum imaging (EELS‐SI) data. This approach leverages the full 3D structure of EELS‐SI data to detect subtle spectral anomalies while preserving both spatial and spectral correlations across the datacube. By employing cross‐entropy loss and training on bulk spectra, the model learns to reconstruct bulk features characteristic of the defect‐free material. In exploring methods for anomaly detection, both the 3D‐CVAE approach and principal component analysis (PCA) are evaluated, testing their performance using FeL‐edge ΔEpeak shifts designed to simulate material defects. These results show that 3D‐CVAE achieves superior anomaly detection and maintains consistent performance across various shift magnitudes. The method demonstrates clear bimodal separation between bulk and anomalous spectra, enabling reliable classification. Further analysis verifies that lower‐dimensional representations are robust to anomalies in the data. While performance advantages over PCA diminish with decreasing anomaly concentration, our method maintains high reconstruction quality even in challenging, noise‐dominated spectral regions. This approach provides a robust framework for unsupervised automated detection of spectral anomalies in EELS‐SI data, particularly valuable for analyzing complex material systems.

Chemistry

Getting Warmer: IceCube Nears Freeze Out

IceCube has recently detected a diffuse population of high-energy neutrinos arising from the Milky Way. We use this high-significance detection to place new limits on dark matter (DM) annihilation to neutrinos with two complementary approaches. The first method uses the background-subtracted Galactic longitude distribution of shower events to place a conservative bound on the DM annihilation cross section that does not rely on any assumed Galactic cosmic ray emission model; the resulting limits on the velocity-averaged annihilation cross section improve upon existing bounds by factors of a few. The second method uses the template-dependent neutrino energy spectra from the Inner Galaxy, inferred under different Galactic cosmic ray emission models. This complementary approach shows that the inferred Galactic neutrino intensities are already sensitive to DM contributions near the thermal-relic benchmark for a range of TeV-scale DM masses, though this comparison is more model-dependent. Our results demonstrate that measurements of diffuse Galactic neutrino emission can be used as a powerful probe of DM annihilation into neutrinos. Future observations with IceCube-Gen2 and KM3NeT will substantially extend this sensitivity, potentially allowing a decisive test of the thermal freeze-out mechanism with Galactic neutrino observations.

Mukhopadhyay, Mainak [Fermilab; Chicago U., KICP;

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES

Energy-Optimal Vehicle Longitudinal Motion Control via Pontryagin’s Minimum Principle and Ultra-Local Model

Longitudinal vehicle motion control is essential for enhancing performance and optimizing a vehicle’s energy usage. However, it remains a challenging task due to the nonlinear and uncertain nature of vehicle dynamics, along with varying driving conditions. This paper presents a novel ultra-local optimal control approach based on Pontryagin’s Minimum Principle (PMP) that circumvents the need for detailed system identification by employing an ultra-local model. The control objective is to minimize the total energy consumption under boundary conditions while ensuring smooth traction force generation. The proposed approach is evaluated using a high-fidelity vehicle model in three representative scenarios: (i) nominal driving, (ii) a change in tire road friction coefficient (TRFC) from 0.5 to 0.65 and road slope from 0% to 5% during the maneuver, with target velocity unchanged, and (iii) a change in target velocity from 20 m/s to 0 m/s during the maneuver, while maintaining nominal TRFC and slope conditions. The simulation results demonstrate that the proposed method delivers robust performance, effectively balancing consumption and tracking accuracy in all tested scenarios.

Waleed khan, Muhammad [The University of Texas at

Optimizing Deep Geothermal Drilling for Energy Sustainability in the Appalachian Basin

This study investigates the geological and geomechanical characteristics of the MIP 1S geothermal well in the Appalachian Basin to optimize drilling and address the wellbore stability issues encountered. Data from well logs, sidewall core analysis, and injection tests were used to derive elastic and rock strength properties, as well as stress and pore pressure profiles. A robust 1D-geomechanical model was developed and validated, correlating strongly with wellbore instability observations. This revealed significant wellbore breakout, widening the diameter from 12 ¼ inches to over 16 inches. Advanced technologies like Cerebro Force™ In-Bit Sensing were used to monitor drilling performance with high accuracy. This technology tracks critical metrics such as bit acceleration, vibration in the x, y, and z directions, Gyro RPM, stick-slip indicators, and bending on the bit. Cerebro Force™ readings identified hole drag caused by poor hole conditions, including friction between the drill string and wellbore walls and the presence of cuttings or debris. This led to higher torque and weight on bit (WOB) readings at the surface compared to downhole measurements, affecting drilling efficiency and wellbore stability. Optimal drilling parameters for future deep geothermal wells were determined based on these findings.

Environmental Sciences & Ecology

Hamiltonian switching control of noisy bipartite qubit systems

Abstract We develop a Hamiltonian switching ansatz for bipartite control that is inspired by the quantum approximate optimization algorithm, to mitigate environmental noise on qubits. We demonstrate the control for a central spin coupled to bath spins via isotropic Heisenberg interactions, and then make physical applications to the protection of quantum gates performed on superconducting transmon qubits coupling to environmental two-level-systems (TLSs) through dipole-dipole interactions, as well as on such qubits coupled to both TLSs and a Lindblad bath. The control field is classical and acts only on the system qubits. We use reinforcement learning with policy gradient to optimize the Hamiltonian switching control protocols, using a fidelity objective for specific target quantum gates. We use this approach to demonstrate effective suppression of both coherent and dissipative noise, with numerical studies achieving target gate implementations with fidelities over 0.9999 (four nines) in the majority of our test cases and showing improvement beyond this to values of 0.999 999 999 (nine nines) upon a subsequent optimization by GRadient Ascent Pulse Engineering (GRAPE). We analyze how the control depth, total evolution time, number of environmental TLS, and choice of optimization method affect the fidelity achieved by the optimal protocols and reveal some critical behaviors of bipartite control of quantum gates.

Physics

Compressed baryon acoustic oscillation analysis is robust to modified-gravity models

Abstract We study the robustness of the baryon acoustic oscillation (BAO) analysis to the underlying cosmological model. We focus on testing the standard BAO analysis that relies on the use of a template. These templates are constructed assuming a fixed fiducial cosmological model and used to extract the location of the acoustic peaks. Such “compressed analysis” had been shown to be unbiased when applied to the ΛCDM model and some of its extensions. However, it has not been known whether this type of analysis introduces biases in a wider range of cosmological models where the template may not fully capture relevant features in the BAO signal. In this study, we apply the compressed analysis to noiseless mock power spectra that are based on Horndeski models, a broad class of modified-gravity theories specified with eight additional free parameters. We study the precision and accuracy of the BAO peak-location extraction assuming DESI, DESI II, and MegaMapper survey specifications. We find that the bias in the extracted peak locations is negligible; for example, it is less than 10% of the statistical error for even the proposed future MegaMapper survey. Our findings indicate that the compressed BAO analysis is remarkably robust to the underlying cosmological model.

Astronomy & Astrophysics

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI