Search NASA⌕ Search

SEARCH · Search NASA

Results for “NETHERLANDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

SU-E-T-580: On the Significance of Model Based Dosimetry for Breast and Head and Neck 192Ir HDR Brachytherapy

Purpose: To assess the dosimetric and radiobiological differences between TG43-based and model-based dosimetry in the treatment planning of {sup 192}Ir HDR brachytherapy for breast and head and neck cancer. Methods: Two cohorts of 57 Accelerated Partial Breast Irradiation (APBI) and 22 head and neck (H&N) patients with oral cavity carcinoma were studied. Dosimetry for the treatment plans was performed using the TG43 algorithm of the Oncentra Brachy v4.4 treatment planning system (TPS). Corresponding Monte Carlo (MC) simulations were performed using MCNP6 with input files automatically prepared by the BrachyGuide software tool from DICOM RT plan data. TG43 and MC data were compared in terms of % dose differences, Dose Volume Histograms (DVHs) and related indices of clinical interest for the Planning Target Volume (PTV) and the Organs-At-Risk (OARs). A radiobiological analysis was also performed using the Equivalent Uniform Dose (EUD), mean survival fraction (S) and Tumor Control Probability (TCP) for the PTV, and the Normal Tissue Control Probability (N TCP) and the generalized EUD (gEUD) for the OARs. Significance testing of the observed differences performed using the Wilcoxon paired sample test. Results: Differences between TG43 and MC DVH indices, associated with the increased corresponding local % dose differences observed, were statistically significant. This is mainly attributed to their consistency however, since TG43 agrees closely with MC for the majority of DVH and radiobiological parameters in both patient cohorts. Differences varied considerably among patients only for the ipsilateral lung and ribs in the APBI cohort, with a strong correlation to target location. Conclusion: While the consistency and magnitude of differences in the majority of clinically relevant DVH indices imply that no change is needed in the treatment planning practice, individualized dosimetry improves accuracy and addresses instances of inter-patient variability observed. Research co-financed by the ESF and Greek funds through the Operational Program Education and Lifelong Learning Investing in Knowledge Society of the NSRF. Research Funding Program Aristeia. Nucletron, an Elekta company (Veenendaal, The Netherlands) is gratefully acknowledged for providing Oncentra Brachy v4.4 for research purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-303-10: Impact of Visual Biofeedback On Respiratory Reproducibility in 4DMRI

Purpose: Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4DCT. 4DMRI offers improved contrast. However, long scan times and irregular breathing patterns can be limiting. To address this, we introduced visual biofeedback (VBF) into 4DMRI. Methods: Eight healthy volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted coronal 4DMRIs were acquired on an open 1.0T MR- SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within pre-determined tolerances. 4DMRIs were acquired with and without VBF for 2–8 phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, end-inhale (EI) amplitude, and breathing variability (coefficient of variation, EI-COV). B-spline-based deformable image registration propagated contours from end-exhale (EE) to EI phases. Respiration-induced liver motion was calculated via centroid analysis and compared. Results: Incorporating VBF reduced 2-phase acquisition time (4.7±0.6 and 5.6±1.4 minutes with and without VBF, respectively) while reducing the amplitude EI-COV by 53.0±8.1%. On average, incorporating VBF reduced 8-phase 4DMRI acquisition times by 1.7±1.2 minutes and EI-COVs by 46.0±15.8%. Using VBF yielded higher duty cycles than free breathing (34.7% versus 28.3%, respectively). 4DMRI acquisition time was reduced for the cohort with VBF despite breathing rate remaining similar (10.5±4.0 with vs. 10.6±3.3 BPM without). Respiratory waveforms showed higher EI amplitude with VBF (0.84±0.05 a.u.) as compared to 0.72±0.06 a.u. without. This translated to differences in liver excursions, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.3±3.6, 4.8±2.1, and 1.6±1.0 mm, respectively, with VBF compared to 13.0±6.2, 3.8±2.4, and 1.2±1.4 mm without. Conclusion: Incorporating VBF system into 4DMRI substantially reduced acquisition time and breathing variability. While VBF reduced liver motion variability, differences in excursion were observed, suggesting that implementation will be required throughout the RT workflow. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an equipment evaluation agreement with MedSpira.

60 APPLIED LIFE SCIENCES↗

SU-F-303-12: Implementation of MR-Only Simulation for Brain Cancer: A Virtual Clinical Trial

Purpose: To perform a retrospective virtual clinical trial using an MR-only workflow for a variety of brain cancer cases by incorporating novel imaging sequences, tissue segmentation using phase images, and an innovative synthetic CT (synCT) solution. Methods: Ten patients (16 lesions) were evaluated using a 1.0T MR-SIM including UTE-DIXON imaging (TE = 0.144/3.4/6.9ms). Bone-enhanced images were generated from DIXON-water/fat and inverted UTE. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating intersection and Dice similarity coefficients (DSC) using CT-SIM as ground truth. SynCTs were generated using voxel-based weighted summation incorporating T2, FLAIR, UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized HU differences between synCT and CT-SIM. Dose was recalculated on synCTs; differences were quantified using planar gamma analysis (2%/2 mm dose difference/distance to agreement) at isocenter. Digitally reconstructed radiographs (DRRs) were compared. Results: On average, air maps intersected 80.8 ±5.5% (range: 71.8–88.8%) between MR-SIM and CT-SIM yielding DSCs of 0.78 ± 0.04 (range: 0.70–0.83). Whole-brain MAE between synCT and CT-SIM was 160.7±8.8 HU, with the largest uncertainty arising from bone (MAE = 423.3±33.2 HU). Gamma analysis revealed pass rates of 99.4 ± 0.04% between synCT and CT-SIM for the cohort. Dose volume histogram analysis revealed that synCT tended to yield slightly higher doses. Organs at risk such as the chiasm and optic nerves were most sensitive due to their proximities to air/bone interfaces. DRRs generated via synCT and CT-SIM were within clinical tolerances. Conclusion: Our approach for MR-only simulation for brain cancer treatment planning yielded clinically acceptable results relative to the CT-based benchmark. While slight dose differences were observed, reoptimization of treatment plans and improved image registration can address this limitation. Future work will incorporate automated registration between setup images (cone-beam CT and kilovoltage images) for synCT and CT-SIM. Submitting institution holds research agreements with Philips HealthCare, Best, Netherlands and Varian Medical Systems, Palo Alto, CA. Research partially sponsored via an Internal Mentored Research Grant.

60 APPLIED LIFE SCIENCES↗

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.

60 APPLIED LIFE SCIENCES↗

SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose rate distributions have been obtained for the applicators with and without the plastic cap. An experimental study using EBT3 radiochromic film has been realized in order to verify the Monte Carlo results. Results: The Monte Carlo simulations show that absorbed dose in the first millimeter of skin can increase up to 180% for the Valencia applicator if the plastic cap is absent and up to 1500% for the Leipzig applicators. At deeper distances the increase of dose is smaller being about 10–15%. Conclusion: Important differences have been found if the plastic cap of the applicators is absent in the treatment producing an overdosage in the skin. The user should have a checklist to remind him check always before HDR fraction delivery to insure the plastic cap is placed on the applicator. This work was supported in part by Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156, and by a research agreement with Elekta Brachytherapy, Veenendaal, The Netherlands.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-643: Feasibility of Performing Patient Specific VMAT QA On Single Linac for Plans Treated in Beam-Matched Elekta Agility Linacs

Purpose: The increasing application of VMAT demands a more efficient workflow and QA solution. This study aims to investigate the feasibility of performing VMAT QA measurements on one linac for plans treated on other beam-matched Elekta Agility linacs. Methods: A single model was used to create 24 clinically approved VMAT plans (12 head-and-neck and 12 prostate using 6MV and 10MV respectively) on Pinnacle v9.10 (Philips, Einhoven, Netherlands). All head-and-neck plans were delivered on three beam-matched machines while all prostate cases were delivered on two beam-matched 10MV Agility machines. All plans were delivered onto PTW Octavius 4D phantom with 1500 detector array (PTW, Freiburg, Germany). Reconstructed volume doses were then compared with the Pinnacle reference plans in Verisoft 6.1 under 3%/3mm gamma criteria at local dose. Plans were considered clinically acceptable if >90% of the voxels passing the gamma criteria. Results: All measurements were passed (3D gamma passing rate >90%) and the result shows that the mean difference of 3D gamma of 12 head-and-neck cases is 1.2% with standard deviation of 0.6%. While for prostate cases, the mean difference of 3D gamma is 0.9% with standard deviation of 0.7%. Maximum difference of 3D gamma of all measurements between beam-matched machines is less than 2.5%. The differences of passing rates between different machines were statistically insignificant (p>0.05). Conclusion. The result suggests that ther Conclusion: The result suggests that there exists a 3D gamma threshold, in our case 92.5%, above which the VMAT QA performed in any one of beam-matched machine will also pass in another one. Therefore, VMAT QA efficiency may be increased and phantom set up time can be saved by implementing such method. A constant performance across all beam matched machines must be maintained to make this QA approach feasible.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-14: MRI-Based HDR Prostate Brachytherapy: A Phantom Study for Interstitial Catheter Reconstruction with 0.35T MRI Images

Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI was acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

WE-H-BRC-01: Failure Mode and Effects Analysis of Skin Electronic Brachytherapy Using Esteya Unit

Purpose: A failure mode and effect analysis (FMEA) of skin lesions treatment process using Esteya™ device (Elekta Brachyterapy, Veenendaal, The Netherlands) was performed, with the aim of increasing the quality of the treatment and reducing the likelihood of unwanted events. Methods: A multidisciplinary team with experience in the treatment process met to establish the process map, which outlines the flow of various stages for such patients undergoing skin treatment. Potential failure modes (FM) were identified and the value of severity (S), frequency of occurrence (O), and lack of detectability (D) of the proposed FM were scored individually, each on a scale of 1 to 10 following TG-100 guidelines of the AAPM. These failure modes were ranked according to our risk priority number (RPN) and S scores. The efficiency of existing quality management tools was analyzed through a reassessment of the O and D made by consensus. Results: 149 FM were identified, 43 of which had RPN ≥ 100 and 30 had S ≥ 7. After introduction of the tools of quality management, only 3 FM had RPN ≥ 100 and 22 FM had RPN ≥ 50. These 22 FM were thoroughly analyzed and new tools for quality management were proposed. The most common cause of highest RPN FM was associated with the heavy patient workload and the continuous and accurate applicator-patient skin contact during the treatment. To overcome this second item, a regular quality control and setup review by a second individual before each treatment session was proposed. Conclusion: FMEA revealed some of the FM potentials that were not predicted during the initial implementation of the quality management tools. This exercise was useful in identifying the need of periodic update of the FMEA process as new potential failures can be identified.

60 APPLIED LIFE SCIENCES↗

Heavy-flavor production and medium properties in high-energy nuclear collisions --What next?

Open and hidden heavy-flavor physics in high-energy nuclear collisions are entering a new and exciting stage towards reaching a clearer understanding of the new experimental results with the possibility to link them directly to the advancement in lattice Quantum Chromo-Dynamics (QCD). Some recent results from experiments and theoretical developments regarding open and hidden heavy-flavor dynamics have been debated at the Lorentz Workshop Tomography of the Quark-Gluon Plasma with Heavy Quarks, which was held in October 2016 in Leiden, The Netherlands. Here, we summarize identified common understandings and developed strategies for the upcoming five years, which aim at achieving a profound knowledge of the dynamical properties of the quark-gluon plasma.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Sandia's Current Energy Conversion module for Flexible-Mesh Delft3D flow solver v. 1.0

The DOE has funded Sandia National Labs (SNL) to develop an open-source modeling tool to guide the design and layout of marine hydrokinetic (MHK) arrays to maximize power production while minimizing environmental effects. This modeling framework simulates flows through and around a MHK arrays while quantifying environmental responses. As an augmented version of the Dutch company, Deltares’s, environmental hydrodynamics code, Delft3D, SNL-Delft3D-CEC-FM includes a new module that simulates energy conversion (momentum withdrawal) by MHK current energy conversion devices with commensurate changes in the turbulent kinetic energy and its dissipation rate. SNL-Delft3D-CEC-FM modified the Delft3D flexible mesh flow solver, DFlowFM. The Following is a description of Deltares’s open-source code Delft3D from which Delft3D-CEC is built upon. “Delft3D is a world leading 3D modeling suite to investigate hydrodynamics, sediment transport and morphology and water quality for fluvial, estuarine and coastal environments. As per 1 January 2011, the Delft3D flow (FLOW), morphology (MOR) and waves (WAVE) modules are available in open source. The software is used and has proven his capabilities on many places around the world, like the Netherlands, USA, Hong Kong, Singapore, Australia, Venice, etc. The software is continuously improved and developed with innovating advanced modelling techniques as consequence of the research work of our institute and to stay world leading. The FLOW module is the heart of Delft3D and is a multi-dimensional (2D or 3D) hydrodynamic (and transport) simulation program which calculates non-steady flow and transport phenomena resulting from tidal and meteorological forcing on a curvilinear, boundary fitted grid or spherical coordinates. In 3D simulations, the vertical grid is defined following the so-called sigma coordinate approach or Z-layer approach. The MOR module computes sediment transport (both suspended and bed total load) and morphological changes for an arbitrary number of cohesive and non-cohesive fractions. Both currents and waves act as driving forces and a wide variety of transport formulae have been incorporated. For the suspended load this module connects to the 2D or 3D advection-diffusion solver of the FLOW module; density effects may be taken into account. An essential feature of the MOR module is the dynamic feedback with the FLOW and WAVE modules, which allow the flows and waves to adjust themselves to the local bathymetry and allows for simulations on any time scale from days (storm impact) to centuries (system dynamics). It can keep track of the bed composition to build up a stratigraphic record. The MOR module may be extended to include extensive features to simulate dredging and dumping scenarios. For over 30 years Deltares has been in the forefront of these types of combined morphological simulation techniques.”

Chartand, Chris↗

Risk of Positive Sentinel Lymph Node After Neoadjuvant Systemic Therapy in Clinically Node-Negative Breast Cancer: Implications for Postmastectomy Radiation Therapy and Immediate Breast Reconstruction

Background: Residual axillary lymph node involvement after neoadjuvant systemic therapy (NST) is the determining factor for postmastectomy radiation therapy (PMRT). Preoperative identification of patients needing PMRT is essential to enable shared decision-making when choosing the optimal timing of breast reconstruction. We determined the risk of positive sentinel lymph node (SLN) after NST in clinically node-negative (cN0) breast cancer. Methods: All cT1-3N0 patients treated with NST followed by mastectomy and SLNB between 2010 and 2016 were identified from the Netherlands Cancer Registry. Rate of positive SLN for different breast cancer subtypes was determined. Logistic regression analysis was performed to determine correlated clinicopathological variables with positive SLN. Results: In total 788 patients were included, of whom 25.0% (197/788) had positive SLN. cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+ , and cT1-2N0 triple-negative patients had the lowest rate of positive SLN: 7.2–11.5%, 0–6.3%, and 2.9–6.2%, respectively. cT1-3N0 ER+HER2− and cT3N0 triple-negative patients had the highest rate of positive SLN: 23.8–41.7% and 30.4%, respectively. Multivariable regression analysis showed that cT2 (odds ratio [OR] 1.93; 95% confidence interval [CI] 1.01–3.96), cT3 (OR 2.56; 95% CI 1.30–5.38), grade 3 (OR 0.44; 95% CI 0.21–0.91), and ER+HER2− subtype (OR 3.94; 95% CI 1.77–8.74) were correlated with positive SLN. Conclusions: In cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+, and cT1-2N0 triple-negative patients treated with NST, immediate reconstruction can be considered an acceptable option due to low risk of positive SLN. In cT1-3N0 ER+HER2− and cT3N0 triple-negative patients treated with NST, risks and benefits of immediate reconstruction should be discussed with patients due to the relatively high risk of positive SLN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subsurface redox potential and water level at the Elkhorn Slough NERR

This resource contains various hydrological, and geochemical data from Elkhorn Slough National Estuarine Research Reserve from the years 2020 and 2021. These data have been used to assess how continuous measurements of environmental variables. The data can be used to understand processes at timescales over which biochemical transformations can happen. Especially, the data were used to explain the local subsurface hydrology, and its implication, in an experimental transect in a coasta estuary. Water level and water temperature were measured in-situ with Solinst pressure transducer loggers (Ontario, Canada). Redox potential was collected using in-situ, redox sensors (Paleoterra, The Netherlands) connected to CR1000X Campbell data loggers (Logan, Utah). Meteorological data was gathered from the Elkhorn Slough meteorological station.

54 ENVIRONMENTAL SCIENCES↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

FAST Model Calibration and Validation of the OC5-DeepCwind Floating Offshore Wind System Against Wave Tank Test Data

During the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. The OC5 project revealed a general underprediction of loads and motions by the participating numerical models. This paper discusses several model calibration studies that were conducted to identify potential model parameter adjustments that help to improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), and hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more complex combined wind and wave validation cases. The analysis presented in this paper does not claim to be an exhaustive parameter identification study but is aimed at describing the qualitative impact of different model parameters on the system response. This work should help to provide guidance for future systematic parameter identification and uncertainty quantification efforts.

17 WIND ENERGY↗

FINAL REPORT

Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusion within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.

09 BIOMASS FUELS↗

Climate data, analysis and models for the study of natural variability and anthropogenic change

Gridded Temperature Under prior/current support, we completed and published (Jones et al., 2012) the fourth major update to our global land dataset of near-surface air temperatures, CRUTEM4. This is one of the most widely used records of the climate system, having been updated, maintained and further developed with DoE support since the 1980s. We have continued to update the CRUTEM4 (Jones et al., 2012) database that is combined with marine data to produce HadCRUT4 (Morice et al., 2012). The emphasis in our use of station temperature data is to access as many land series that have been homogenized by National Meteorological Services (NMSs, including NCDC/NOAA, Asheville, NC). Unlike the three US groups monitoring surface temperatures in a similar way, we do not infill areas that have no or missing data. We can only infill such regions in CRUTEM4 by accessing more station temperature series. During early 2014, we have begun the extensive task of updating as many of these series as possible using data provided by some NMSs and also through a number of research projects and programs around the world. All the station data used in CRUTEM4 have been available since 2009, but in Osborn and Jones (2014) we have made this more usable using a Google Earth interface (http://www.cru.uea.ac.uk/cru/data/crutem/ge/ ). We have recently completed the update of our infilled land multi-variable dataset (CRU TS 3.10, Harris et al., 2014). This additionally produces complete land fields (except for the Antarctic) for temperature, precipitation, diurnal temperature range, vapour pressure and sunshine/cloud. Using this dataset we have calculated sc-PDSI (self-calibrating Palmer Drought Severity Index) data and compared with other PDSI datasets (Trenberth et al., 2014). Also using CRU TS 3.10 and Reanalysis datasets, we showed no overall increase in global temperature variability despite changing regional patterns (Huntingford et al., 2013). Harris et al. (2014) is an update of an earlier dataset (Mitchell and Jones, 2005) which also had earlier DoE support. The earlier dataset has been cited over 1700 times according to ResearcherID on 31/July/2014 and the recent paper has already been cited 22 times. Analyses of Temperature Data Using the ERA-Interim estimate of the absolute surface air temperature of the Earth (instead of in the more normal form of anomalies) we compared the result against estimates we produced in 1999 with earlier DoE support. The two estimates are surprisingly close (differing by a couple of tenths of a degree Celsius), with the average temperature of the world (for 1981-2010) being very close to 14°C (Jones and Harpham, 2013). We have assessed ERA-Interim against station temperatures from manned and automatic weather station measurements across the Antarctic (Jones and Lister, 2014). Agreement is generally excellent across the Antarctic Peninsula and the sparsely sampled western parts of Antarctica. Differences tend to occur over eastern Antarctica where ERA-Interim is biased warm (up to 6°C) in the interior of the continent and biased cool (up to 6°C) for some of the coastal locations. Opportunities presented themselves during 2012 for collaborative work with a couple of Chinese groups. Three papers develop new temperature series for China as a whole and also for the eastern third of China (Wang et al., 2014, Cao et al., 2013 and Zhao et al., 2014). A dataset of ~400 daily Chinese temperature stations has been added to the CRU datasets. The latter paper finds that urban effects are generally about 10% of the long-term warming trend across eastern China. A fourth paper (Wang et al., 2013) illustrates issues with comparisons between reanalyses and surface temperatures across China, a method that has been widely used by some to suggest urban heating effects are much larger in the region. ERA-Interim can be used but NCEP/NCAR comparisons are very dependent on the period analysed. Earlier a new temperature dataset of homogenized records was developed for China (Li et al., 2009). Urbanization has also been addressed for London (Jones and Lister, 2009) where two rural sites have not warmed more than a city centre site since 1900. Additionally, in Ethymiadis and Jones (2010) we show that land air temperatures agree with marine data around coastal areas, further illustrating that urbanization is not a major component of large-scale surface air temperature change. Early instrumental data (before the development of modern thermometer screens) have always been suspected of being biased warm in summer, due to possible direct exposure to the sun. Two studies (Böhm et al., 2010 and Brunet et al., 2010) show this for the Greater Alpine Region (GAR) and for mainland Spain respectively. The issue is important before about 1870 in the GAR and before about 1900 in Spain. After correction for the problems, summer temperature estimates before these dates are cooler by about 0.4°C. In Jones and Wigley (2010), we discussed the importance of the biases in global temperature estimation. Exposure and to a lesser extent urbanization are the most important biases for the land areas, but both are dwarfed by the necessary adjustments for bucket SST measurements before about 1950. Individual station homogeneity is only important at the local scale. This was additionally illustrated by Hawkins and Jones (2013) where we replicated the temperature record developed by Guy Stewart Callendar in papers in 1938 and 1961. Analyses of Daily Climate Data Work here indicates that ERA-Interim (at least in Europe, Cornes and Jones, 2013, discussed in more detail in this proposal) can be used to monitor extremes (using the ETCCDI software – see Zhang et al., 2011). Additionally, also as a result of Chinese collaboration, a new method of daily temperature homogenization has been developed (Li et al., 2014). In Cornes and Jones (2011) we assessed storm activity in the northeast Atlantic region using daily gridded data. Even though the grid resolution is coarse (5° by 5° lat/long) the changes in storm activity are similar to those developed from the pressure triangle approach with station data. Analyses of humidity and pressure data In Simmons et al. (2010) we showed a reduction in relative humidity over low-latitude and mid-latitude land areas for the 10 years to 2008, based on monthly anomalies of surface air temperature and humidity from ECMWF reanalyses (ERA-40 and ERA-Interim) and our earlier land-only dataset (CRUTEM3) and synoptic humidity observations (HadCRUH). Updates of this station-based humidity dataset (now called HadISDH) extend the record, showing continued reductions (Willett et al., 2013). Analyses of Proxy Temperature Data In Vinther et al. (2010), relationships between the seasonal stable isotope data from Greenland Ice Cores and Greenland and Icelandic instrumental temperatures were investigated for the past 150-200 years. The winter season stable isotope data are found to be influenced by the North Atlantic Oscillation (NAO) and very closely related to SW Greenland temperatures. The summer season stable isotope data display higher correlations with Icelandic summer temperatures and North Atlantic SST conditions than with local SW Greenland temperatures. In Jones et al. (2014) we use these winter isotope reconstructions to show the expected inverse correlation (due to the NAO) with winter-season documentary reconstructions from the Netherlands and Sweden over the last 800 years. Finally, in this section Jones et al. (2013) shows the agreement between tree-ring width measurements from Northern Sweden and Finland and an assessment of the link to explosive volcanic eruptions. An instrumental record for the region in the early 19th century indicates that the summer of 1816 was only slightly below normal, explaining why this year has normal growth for both ring width and density. GCM/RCM/Reanalysis Evaluation In this section we have intercompared daily temperature extremes across Europe in Cornes and Jones (2013) using station data, E-OBS and ERA-Interim. We have additionally considered the impact of the urban issue on the global scale using the results of the Compo et al. (2011) Reanalyses, 20CR. These only make use of SST and station pressure data. Across the world’s land areas, they indicate similar warming since 1900 to that which has occurred (Compo et al., 2013), again illustrating that urbanization is not the cause of the long-term warming. Changes in HadCRUH global land surface specific humidity and CRUTEM3 surface temperatures from 1973 to 1999 were compared to the CMIP3 archive of climate model simulations with 20th Century forcings (Willett et al., 2010). The models reproduce the magnitude of observed interannual variance over all large regions. Observed and modelled trends and temperature-humidity relationships are comparable with the exception of the extra-tropical Southern Hemisphere where observations exhibit no trend but models exhibit moistening.

54 ENVIRONMENTAL SCIENCES↗