A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

Cruikshank, D. P.↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

B-MINE: The Balloon-Borne Microcalorimeter Nuclear Line Explorer

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the 44Ti emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3 sigma sensitivity in 10 (exp 6) s of 3.3 x 10(exp -7) ph cm(exp -2) s(exp -1) at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroid and width in CAS A.

Silver, E.↗

Pixel Array Germanium Detectors for Nuclear Physics (Final Technical Report)

The Department of Energy (DOE) Office of Nuclear Physics supports the development and maintenance of germanium gamma-ray detector arrays at national laboratories and universities. Germanium gamma-ray detectors provide state-of-the-art gamma-ray energy resolution, making them critical for gamma-ray and x-ray spectroscopy in Nuclear Physics. Furthermore, detector segmentation and charge-signal waveform processing enables 3-dimensional (3D) measurement of gamma-ray interaction locations needed for the highest-fidelity Nuclear Physics experiments. Attaining and maintaining excellent gamma-ray energy resolution depends largely on the naturally excellent charge-collection properties of germanium crystals. However, the optimal method for achieving the best practical 3D spatial resolution within the detector volume at high counting rates is less clear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time infrared spectroscopy coupled with blind source separation for nuclear waste process monitoring

On-line infrared absorbance spectroscopy enables rapid measurement of solution-phase molecular species. Many spectra-to-concentration models exist for spectral data, with some models able to handle overlapping spectral bands and nonlinearities. However, model accuracy is limited by the quality of training data used in model fitting. The process spectra of nuclear waste simulants at the Savannah River Site display incongruity between training and process spectra; the glycolate spectral signature in the training data does not match the glycolate signature in Savannah River National Laboratory process data. A novel blind source separation algorithm is proposed that preprocesses spectral data so that process spectra more closely resemble training spectra, thereby improving model quantification accuracy when unexpected sources of variation appear in process spectra. The novel blind source separation preprocessing algorithm is shown to improve nitrate quantification from an R 2 of 0.934 to 0.988 and from 0.267 to 0.978 in two instances analyzing nuclear waste simulants from the Slurry Receipt Adjustment Tank and Slurry Mix Evaporator cycle at the Savannah River Site.

Crouse, Steven H.↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

G EANT 4 atomic relaxation data for transfermium nuclei (Z = 101–104)

Advanced theoretical methods can accurately calculate various atomic observables and predict electronic structure. Still, systematic computations of the radiative and non-radiative transition probabilities and energies are missing for the actinides and all the transfermium elements. However, these compilations are needed for comprehensive Monte-Carlo simulations (such as GEANT4) of the radioactive decay of transfermium nuclei. These simulations can forma basis for data analysis of experiments, especially with complex detection setups. Investigation of the transfermium nuclei is crucial for understanding the nature of the nuclear force. In this study, simulations based on data from the Jena Atomic Calculator (JAC) and the data from the Evaluated Atomic Data Library (EADL) present in GEANT4 were found compatible for the three elements Ba(Z = 56), U(Z = 92), and Fm(Z = 100), thus, validating the JAC calculations. For Z> 100, we also found sound agreement between simulations that used data generated with JAC and experimental results involving No(Z = 102) and Rf(Z = 104) isotopes. In conclusion, these results demonstrate that JAC can produce reliable atomic data sets for transfermium elements, which will assist in analyzing nuclear-decay-spectroscopy experiments.

GEANT4↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Cations impact radical reaction dynamics in concentrated multicomponent aqueous solutions

Ultraviolet (UV) photolysis of nitrite ions (NO 2 – ) in aqueous solutions produces a suite of radicals, viz., NO · , O – , · OH, and · NO 2 . The O – and NO · radicals are initially formed from the dissociation of photoexcited NO 2 – . The O – radical undergoes reversible proton transfer with water to generate · OH. Both · OH and O – oxidize the NO 2 – to · NO 2 radicals. The reactions of · OH occur at solution diffusion limits, which are influenced by the nature of the dissolved cations and anions. Here, we systematically varied the alkali metal cation, spanning the range from strongly to weakly hydrating ions, and measured the production of NO · , · OH, and · NO 2 radicals during UV photolysis of alkaline nitrite solutions using electron paramagnetic resonance spectroscopy with nitromethane spin trapping. Comparing the data for the different alkali cations revealed that the nature of the cation had a significant effect on production of all three radical species. Radical production was inhibited in solutions with high charge density cations, e.g., lithium, and promoted in solutions containing low charge density cations, e.g., cesium. Through complementary investigations with multinuclear single pulse direct excitation nuclear magnetic resonance (NMR) spectroscopy and pulsed field gradient NMR diffusometry, cation-controlled solution structures and extent of NO 2 – solvation were determined to alter the initial yields of · NO and · OH radicals as well as alter the reactivity of NO 2 – toward · OH, impacting the production of · NO 2 . The implications of these results for the retrieval and processing of low-water, highly alkaline solutions that comprise legacy radioactive waste are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Thorough Characterization of the Tellurocyanate Anion

Tellurocyanate, [TeCN] − , is the heaviest group 16 congener of the cyanate anion, [OCN] − . Due to the relative instability of the C─Te bond, tellurocyanate chemistry has seen only scarce attention. Here, we present the facile synthesis and thorough characterization of [K@crypt-222][TeCN]. The anion is essentially linear with interatomic distances C─N = 1.150(6)Å and C─Te = 2.051(4)Å, thus approximating a C≡N triple bond and for C─Te a bond order between 1 and 2. Fully 13 C and 15 N labeled [Te 13 C 15 N] − allowed for the extraction of chemical shifts and all possible coupling constants ( 13 C = 77.8 ppm, 15 N = 285.7 ppm, 125 Te = −566 ppm, 1 J 13C-15N = 8 Hz, 1 J 13C-125Te = 748 Hz, 2 J1 5N-125Te = 55 Hz), which were also determined independently by quantum chemical calculations. In the series [ChCN] − (Ch = O─Te), [TeCN] − shows the strongest spin-orbit coupling (SOC) induced heavy-atom effect on the light-atom shielding (SO-HALA-effect). In contrast, 15 N shifts are also well described without considering relativistic effects and/or SOC. Negative-ion photoelectron spectroscopy was used to extract the electron affinity (EA = 3.034 eV) and spin-orbit splitting (3807 cm −1 ) of [TeCN] • . These values continue the trends of falling EA and rising SOC in the series [ChCN] • .

Bonding analysis↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Ab initio study of the structure and properties of amorphous silicon hydride from accelerated molecular dynamics simulations

This paper presents a large-scale ab initio simulation study of amorphous silicon hydride (a-Si 1-x H x ) with an emphasis on the structure and properties of the material across a range of hydrogen concentration by combining accelerated molecular dynamics (MD) simulations with first-principles density-functional calculations. The accelerated MD scheme relied on classical metadynamics, which enabled the development of 2500+ high-quality structural models of a-Si 1-x H x , with system sizes ranging from 150 to 6000 atoms and hydrogen concentrations vary from 6 to 20 at. %. The resulting amorphous networks were found to be completely free from any coordination defects and that they all exhibited a pristine band-gap in their electronic spectrum. The microstructural properties of hydrogen distributions were examined with an emphasis on the presence of isolated and clustered environments of hydrogen atoms. The results were compared with experimental data obtained from X-ray diffraction, infrared spectroscopy and nuclear magnetic resonance studies.

36 MATERIALS SCIENCE↗

Deuterium retention in MeV ion-irradiated beryllium

Beryllium, as the material of choice for the ITER first wall, will be subject to high energy neutrons during the operation of the fusion device. Such irradiation will create displacement damage in the crystal lattice, which is known to influence hydrogen isotope retention, e.g. in iron and tungsten. Here in our study, we irradiated beryllium samples with high-energy oxygen ions up to various dpa levels (0.01 dpa, 0.1 dpa, and 1 dpa) and subsequently exposed the samples to deuterium plasma at 370 K and 573 K. The amount of retained deuterium was measured by thermal desorption spectroscopy and nuclear reaction analysis and was found to decrease by about 18% in the samples damaged up to 0.1 dpa compared to the undamaged ones. Further damaging up to 1 dpa did not show any additional effects on deuterium retention. Transmission electron microscopy was used to check for the existence of bubbles after plasma exposure.

36 MATERIALS SCIENCE↗

Inhibition of asphaltene aggregation using deep eutectic solvents: COSMO-RS calculations and experimental validation

Asphaltene precipitation/deposition adversely affects various oil and gas processes, such as oil recovery, transportation, and petroleum processing. The resulting increase in viscosity of crude oil decreases distillate yields creating unstable phase separation. Deep eutectic solvents (DESs) have recently gained interest as inhibitors of asphaltene aggregation. The goal of the present study is to derive the mechanism of inhibition of petroleum asphaltene aggregation by a novel screening of DESs. An archipelago-based chemical structure of asphaltene was adopted for performing quantum chemical calculations. The structure was used in the conductor-like screening model for real solvents (COSMO-RS) model to screen potential DESs for asphaltene precipitation. It was found that DESs containing thymol were the most promising of the 153 DES combinations screened. The COSMO-RS predictions were validated experimentally using solubility data of asphaltene in DESs. Among the studied DESs, thymol-diphenyl ether provided the highest solubility for asphaltene, which was further validated using the experimental and the COSMO-RS predicted data. In addition, to characterize the structural interactions between asphaltene and DESs, Fourier transform infrared (FTIR) spectroscopy and nuclear magnetic resonance (NMR) measurements were performed. It was found that strong interaction between asphaltene and the DESs is responsible for the higher asphaltene dispersion. Finally, the present approach opens pathways to rationally design and understand the impact of structural variation of DESs based on their interactions with asphaltene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

Spectral emission characteristics near 646 nm and plasma properties of laser-induced plasma of gaseous uranium hexafluoride

We present a detailed investigation of the temporal evolution of line and continuum emissions in laser-induced breakdown spectroscopy (LIBS) of gaseous uranium hexafluoride (UF 6 ), focusing on the spectral region near 646 nm. Spectral emission features, signal-to-background ratios (SBRs) of selected uranium lines, and spectral linewidths were examined under varying UF 6 pressures (15–60 Torr) and laser pulse energies (10–60 mJ). Higher pressures and pulse energies enhanced continuum emission and reduced SBRs but did not cause significant spectral congestion. Additional studies with the use of different laser systems, including nanosecond-pulsed Nd:YAG lasers (at fundamental and various harmonics) and a femtosecond-pulsed Ti:sapphire laser, revealed long-lived plasma continua in all cases. This persistent continuum is attributed to a pseudo-continuum from overlapping molecular emissions, as its intensity scales linearly with electron number density, deviating from the expected quadratic dependence of classical ion–electron interactions for free-free and free-bound continuum emission. Based on plasma persistence time, SBR, U II/U I intensity ratios, and electronic excitation temperature, no fundamental advantage was found for femtosecond-pulsed lasers over conventional nanosecond-pulsed ones for UF 6 enrichment assay with direct LIBS measurement.

Laser-induced breakdown spectroscopy↗

Unveiling the Liquid Electrolyte Solvation Structure by Small Angle X-ray Scattering

The fundamental understanding of the liquid electrolyte (LE) solvation structure and electrode–electrolyte interface behavior will bring more in-depth thinking and revolutionary changes to the entire electrochemical energy storage field. Regardless of the variety of techniques available, the methods employed to investigate electrolyte solvation structures over a long-range are severely limited. Small-angle X-ray scattering (SAXS) is an ideal complement to Raman spectroscopy, Fourier transform infrared spectroscopy, or nuclear magnetic resonance, which offers a unique perspective from a larger scale on clusters or networks in electrolytes. Understanding the solvation structures from a few angstroms to hundreds of nanometers will undoubtedly lay a good foundation for studying the macroscopic transport properties, such as viscosity and ionic conductivity, of the LEs. Here, in this Perspective, we discuss the use of SAXS to investigate the solvation structures in different electrolyte systems, a prospect for the SAXS broader application in the electrolyte study, and some challenges that need to be solved in the SAXS application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗