Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Multiplicity Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Application of an energy-dependent instrument response function to analysis of nTOF data from cryogenic DT experiments

Neutron time-of-flight (nTOF) detectors are used to diagnose the conditions present in inertial confinement fusion (ICF) experiments and basic laboratory physics experiments performed on an ICF platform. The instrument response function (IRF) of these detectors is constructed by convolution of two components: an x-ray IRF and a neutron interaction response. The shape of the neutron interaction response varies with incident neutron energy, changing the shape of the total IRF. Analyses of nTOF data that span a broad range of energies must account for this energy-dependence in order to accurately infer plasma parameters and nuclear properties in ICF experiments. This work briefly reviews a matrix multiplication approach to convolution which allows for an energy-dependent change in the shape of the IRF. This method is applied to synthetic data resembling symmetric cryogenic DT implosions to examine the effect of the energy-dependent IRF on the inferred areal density. Here, results of forward fits that infer ion temperatures and areal densities from nTOF data collected during cryogenic DT experiments on OMEGA are also discussed.

47 OTHER INSTRUMENTATION↗

Determining the average prompt-fission-neutron multiplicity for Pu 239 ( n , f ) via a Pu 240 ( α , α ' f ) surrogate reaction

The average prompt-fission-neutron multiplicity ν ¯ is of significance in the areas of nuclear theory, nuclear nonproliferation, and nuclear energy. In this work, the surrogate-reaction method has been used for the first time to indirectly determine ν ¯ for Pu 239 ( n , f ) via Pu 240 ( α , α ' f ) reactions. A Pu 240 target was bombarded with a beam of 53.9-MeV α particles. Scattered α particles, fission products, and neutrons were measured with the NeutronSTARS detector array. Values of ν ¯ were obtained for a continuous range of equivalent incident neutron energies between 0.25 and 26.25 MeV, and the results agree well with direct neutron measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutrino Interactions observed with Large Area Picosecond Photodetectors in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water-based neutrino detector located at Fermilab, approximately 110 m downstream of the Booster Neutrino Beam (BNB). ANNIE utilizes both photomultiplier tubes (PMTs) and advanced photodetectors, specifically Large Area Picosecond Photodetectors (LAPPDs), to detect Cherenkov light emitted by leptons produced in neutrino interactions within ANNIE. LAPPDs are a novel technology designed to detect photons with picosecond-level temporal resolution and sub-millimetre spatial precision. Multiple LAPPDs have been deployed in the ANNIE detector. This is the first use of this technology in a running particle physics experiment and has yielded the first detection of light from neutrino interactions in water with LAPPDs. In this poster, I will showcase the operational performance and functionality of LAPPDs in the ANNIE experiment. Neutrino beam data from the BNB is used to evaluate the timing precision, hit reconstruction performance, and beam response of deployed LAPPDs, demonstrating how this novel picosecond-resolution technology performs in a running neutrino water Cherenkov detector. This work highlights the successful integration of LAPPDs in ANNIE and provides quantitative benchmarks that inform their application in future neutrino experiments requiring high-resolution photon detection.

Aman, Mohammad Adil [Florida State U.] (ORCID:0009↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A First Search for Argon-Bound Neutron-Antineutron Oscillation using the MicroBooNE LArTPC

The use of Liquid Argon Time Projection Chambers (LArTPCs) as a detector technology in neutrino experiments has grown considerably over the past two decades. The excellent spatial and calorimetric resolution offered by LArTPCs enable precise neutrino oscillation measurements as well as beyond-Standard Model searches. One such search, which is the focus of this note, is the search for nucleus-bound neutron-antineutron (n ₋ n̄) oscillation. The n ₋ n̄ oscillation process is a baryon number violating process that produces a unique, star-like topology as a result of multiple final state pions. This unique signature is a key feature that may be used to search for this signal process. This note describes a machine learning-based analysis of MicroBooNE data, making use of a sparse convolutional neural network to search for n ₋ n̄ oscillation-like signals in MicroBooNE. While the future DUNE LArTPC can search for this signature with high sensitivity, existing MicroBooNE data can be used to demonstrate and validate methodologies that can be used as part of the DUNE search. This document presents the first-ever search for n ₋ n̄ oscillation in a LArTPC, using MicroBooNE off-beam data (data collected when the neutrino beam was not running).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first search for argon-bound neutron-antineutron oscillation using the MicroBooNE LArTPC

The use of Liquid Argon Time Projection Chambers (LArTPCs) as a detector technology in neutrino experiments has grown considerably over the past two decades. The excellent spatial and calorimetric resolution offered by LArTPCs enable precise neutrino oscillation measurements as well as beyond-Standard Model searches. One such search, which is the focus of this note, is the search for nucleus-bound neutron-antineutron (n – n̄) oscillation. The n – n̄ oscillation process is a baryon number violating process that produces a unique, star-like topology as a result of multiple final state pions. This unique signature is a key feature that may be used to search for this signal process. This note describes a machine learning-based analysis of MicroBooNE data, making use of a sparse convolutional neural network to search for n – n̄ oscillation-like signals in MicroBooNE. While the future DUNE LArTPC can search for this signature with high sensitivity, existing MicroBooNE data can be used to demonstrate and validate methodologies that can be used as part of the DUNE search. This document presents the first-ever search for n – n̄ oscillation in a LArTPC, using MicroBooNE off-beam data (data collected when the neutrino beam was not running).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron 𝛽 decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25, 30, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one-year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from 109Cd and 113Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from (2±2)×109/cm3 at the center to (26±2)×109/cm3 at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

Taylor, RJ [North Carolina State University]↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First results from the LAPPDs in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-dopedwater Cherenkov detector with a submerged water-based liquid scintillator filled vessel. It is on-axis of the Booster Neutrino Beam (BNB) at Fermilab, and its main physics goal is to measurethe neutrino cross-section which will improve the systematic uncertainties of next-generationlong-baseline neutrino experiments. The first such measurement will be the final state neutronmultiplicity of neutrino-nucleus interactions in water. ANNIE is also the first large-scale highenergy physics experiment to deploy multiple Large Area Picosecond Photodetectors (LAPPD), anovel photon detector technology with a timing resolution of <100 ps and a sub-centimeter spatialresolution which will help to improve the vertex reconstruction. This work will give an updateon the status of the LAPPD deployment as well as first results from neutrino beam induced eventsrecorded by the LAPPDs.

79 ASTRONOMY AND ASTROPHYSICS↗

New Experiments for Detecting Emissions from Fission

Ensuring that nuclear science and technology is used solely for peaceful purposes is one of the most pressing challenges facing our society. The Consortium for Monitoring, Technology, and Verification (MTV) mission is to help meet this challenge by providing advanced technology and trained talent for careers in nuclear security and nonproliferation. The study of nuclear fission is one area of interest in the MTV. We are performing new experiments for the characterization of neutron and gamma ray emissions from fission fragments. These emissions are signatures for the detection and characterization of nuclear materials. To perform these experiments, we have developed Fission Sphere (FS-3), an array of forty organic stilbene detectors operated in time-coincidence. The FS-3 is used to measure the prompt emissions of neutrons and gamma rays from Cf-252 spontaneous fission. These new data will be used to validate physics-based prediction codes, including CGMF and FREYA, and will be useful in future ENDF and ENSDF evaluations. This paper will present results from the first experiments using FS-3 and a Cf-252 spontaneous fission source. It will compare the experimental results with predictions from theory and Monte Carlo simulation. Specifically, we will describe the correlations among energy, multiplicity, and angles of emitted particles. We will also discuss the application of these correlations in multiplicity counting techniques, which are widely used in nuclear safeguards.

Pozzi, S. A.↗

Birefringence tests of gravity with multimessenger binaries

Extensions to General Relativity (GR) allow the polarization of gravitational waves (GW) from astrophysical sources to suffer from amplitude and velocity birefringence, which respectively induce changes in the ellipticity and orientation of the polarization tensor. Here, we introduce a multi-messenger approach to test this polarization behavior of GWs during their cosmological propagation using binary sources, for which the initial polarization is determined by the inclination and orientation angles of the orbital angular momentum vector with respect to the line of sight. In particular, we use spatially resolved radio imaging of the jet from a binary neutron star (BNS) merger to constrain the orientation angle and hence the emitted polarization orientation of the GW signal at the site of the merger, and compare to that observed on Earth by GW detectors. For GW170817, using past measurements of the inclination angle, we constrain the deviation from GR due to amplitude birefringence to κ A = $-0.12^{+0.60}_ {-0.61}$, while the velocity birefringence parameter κ V remains unconstrained. The inability to constrain κ V is due to the low amplitude of GW170817 in the Virgo detector, and measurements of the polarization orientation require information from a combination of multiple detectors with different alignments. For this reason, we also mock future BNS mergers with resolved afterglow proper motion and project that κ V could be constrained to a precision of 5 rad (corresponding to an angular shift of the GW polarization of δ φV ≈ 0.2 rad for a BNS at 100 Mpc) by a future network of third-generation ground-based GW detectors such as Cosmic Explorer and the radio High Sensitivity Array. Crucially, this velocity birefringence effect cannot be constrained with dark binary mergers as it requires polarization information at the emission time, which can be provided only by electromagnetic emission.

79 ASTRONOMY AND ASTROPHYSICS↗

First light from beam neutrinos on an LAPPD in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is both a physics experiment and a technology testbed for next-generation light-based neutrino detection. In this paper, we report the first demonstration of a fully integrated Large Area Picosecond Photodetector (LAPPD) operating in a running neutrino beam experiment. Particular focus is given to the design, commissioning, and successful deployment of the Packaged ANNIE LAPPD (PAL), a waterproof, self-triggering module incorporating fast waveform digitization and precision timing synchronized to the ANNIE detector subsystems. We identify beam-correlated LAPPD data frames consistent with charged-current neutrino interactions observed in multiple detector subsystems, establishing the first detection of neutrino-induced Cherenkov light with an LAPPD. These results validate the system-level performance of LAPPDs under realistic experimental conditions — including long-term stability, timing synchronization, and event matching with conventional PMT and muon detector systems — marking a critical step toward their deployment in future large-scale neutrino and particle detectors.

Cherenkov detectors↗

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

RICH (Robotic Interface Control & Handling) System for VULCAN

High flux neutron beam and high efficiency detectors warrant quick turn arounds of neutron diffraction measurements at the engineering materials diffractometer VULCAN. Efficient change and alignment of samples and automatic measurements at VULCAN are desired for better use of neutron beam time by users. In this work, we aim to develop a proof-of-concept Robotic Interactive Control & Handling System (RICH) for sample handling at VULCAN that could assist high throughput experiments and reduce the overhead time significantly. This was realized by a six-axis desktop robot with trained AI models. The trained AI models can recognize and locate samples in various types of positions in a live video stream. In addition, we developed smart algorithms which used our models on multiple cameras to recognize where samples are with respect to multiple point of views, and then using user-inputted parameters, align them to perform complex measurements.

42 ENGINEERING↗