Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noise deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A further analysis for the minimum-variance deconvolution filter performance

Chi and Mendel (1984) analyzed the performance of minimum-variance deconvolution (MVD). In this correspondence, a further analysis of the performance of the MVD filter is presented. It is shown that the MVD filter performs like an inverse filter and a whitening filter as SNR goes to infinity, and like a matched filter as SNR goes to zero. The estimation error of the MVD filter is colored noise, but it becomes white when SNR goes to zero. This analysis also conects the error power-spectral density of the MVD filter with the spectrum of the causal-prediction error filter.

Chi, Chong-Yung↗

A variance deconvolution estimator for efficient uncertainty quantification in Monte Carlo radiation transport applications

Monte Carlo simulations are at the heart of many high-fidelity simulations and analyses for radiation transport systems. As is the case with any complex computational model, it is important to propagate sources of input uncertainty and characterize how they affect model output. Unfortunately, uncertainty quantification (UQ) is made difficult by the stochastic variability that Monte Carlo transport solvers introduce. The standard method to avoid corrupting the UQ statistics with the transport solver noise is to increase the number of particle histories, resulting in very high computational costs. In this contribution, we propose and analyze a sampling estimator based on the law of total variance to compute UQ variance even in the presence of residual noise from Monte Carlo transport calculations. Here, we rigorously derive the statistical properties of the new variance estimator, compare its performance to that of the standard method, and demonstrate its use on neutral particle transport model problems involving both attenuation and scattering physics. We illustrate, both analytically and numerically, the estimator’s statistical performance as a function of available computational budget and the distribution of that budget between UQ samples and particle histories. We show analytically and corroborate numerically that the new estimator is unbiased, unlike the standard approach, and is more accurate and precise than the standard estimator for the same computational budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The constrained inversion of Nimbus-7 wide field-of-view radiometer measurements for the Earth Radiation Budget

The results of a constrained, wide field-of-view radiometer measurement deconvolution are presented and compared against higher resolution results obtained from the Earth Radiation Budget instrument on the Nimbus-7 satellite and from the Earth Radiation Budget Experiment. The method is applicable to both longwave and shortwave observations and is specifically designed to treat the problem of anisotropic reflection and emission at the top of the atmosphere as well as low signal-to-noise ratios that arise regionally within a field. The procedure is reviewed, and the improvements in resolution obtained are examined. Some minor improvements in the albedo algorithm are also described.

Hucek, Richard R.↗

Determination of Endosperm Protein Secondary Structure in Hard Wheat Breeding Lines using Synchrotron Infrared Microspectroscopy

One molecular aspect of mature hard wheat protein quality for breadmaking is the relative amount of endosperm protein in the {alpha}-helix form compared with that in other secondary structure forms including {beta}-sheet. Modeling of {alpha}-helix and {beta}-sheet absorption bands that contribute to the amide I band at 1650 cm{sup -1} was applied to more than 1500 spectra in this study. The microscopic view of wheat endosperm is dominated by many large starch granules with protein in between. The spectrum produced from in situ microspectroscopy of this mixture is dominated by carbohydrate bands from the large starch granules that fill up the field. The high spatial resolution achievable with synchrotron infrared microspectroscopy enables revealing good in situ spectra of the protein located interstitially. Synchrotron infrared microspectroscopic mapping of 4 {mu}m thick frozen sections of endosperm in the subaleurone region provides spectra from a large number of pixels. Pixels with protein-dominated spectra are sorted out from among adjacent pixels to minimize the starch absorption and scattering contributions. Subsequent data treatment to extract information from the amide I band requires a high signal to noise ratio. Although spectral interference of the carbohydrate band on the amide band is not a problem, the scattering produced by the large starch granules diminishes the signal to noise ratio throughout the spectrum. High density mapping was done on beamlines U2B and U10B at the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, NY. Mapping with a single masked spot size of 5.5 {mu}m diameter or confocal 5 {mu}mX5{mu}m spot size, respectively, on the two beamlines used produced spectra for new breeding lines under current consideration. Appropriate data treatment allows calculation of a numerical estimate of the {alpha}-helix population relative to other secondary protein structures from the position and shape of the amide I absorption band. Current breeding lines show a substantial variance in this feature and its determination allows the prediction of relative quality for breadmaking to be taken into consideration for subsequent steps in the wheat breeding process. Data treatments include deconvolution, modeling of the individual resulting bands that contribute to the amide I band to enable measurement of the relative amounts of both forms. Results with specimens representing multiple crop years of hard winter wheat breeding are reported. It is evident that a range is available for the breeder to choose from, that allows including this protein molecular structural attribute in the selection process.

43 PARTICLE ACCELERATORS↗

Determination of Endosperm Protein Secondary Structure in Hard Wheat Breeding Lines using Synchrotron Infrared Microspectroscopy

One molecular aspect of mature hard wheat protein quality for breadmaking is the relative amount of endosperm protein in the a-helix form compared with that in other secondary structure forms including {beta}-sheet. Modeling of a-helix and {beta}-sheet absorption bands that contribute to the amide I band at 1650 cm-1 was applied to more than 1500 spectra in this study. The microscopic view of wheat endosperm is dominated by many large starch granules with protein in between. The spectrum produced from in situ microspectroscopy of this mixture is dominated by carbohydrate bands from the large starch granules that fill up the field. The high spatial resolution achievable with synchrotron infrared microspectroscopy enables revealing good in situ spectra of the protein located interstitially. Synchrotron infrared microspectroscopic mapping of 4 {mu}m thick frozen sections of endosperm in the subaleurone region provides spectra from a large number of pixels. Pixels with protein-dominated spectra are sorted out from among adjacent pixels to minimize the starch absorption and scattering contributions. Subsequent data treatment to extract information from the amide I band requires a high signal to noise ratio. Although spectral interference of the carbohydrate band on the amide band is not a problem, the scattering produced by the large starch granules diminishes the signal to noise ratio throughout the spectrum. High density mapping was done on beamlines U2B and U10B at the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, NY. Mapping with a single masked spot size of 5.5 {mu}m diameter or confocal 5 {mu}m x 5 {mu}m spot size, respectively, on the two beamlines used produced spectra for new breeding lines under current consideration. Appropriate data treatment allows calculation of a numerical estimate of the a-helix population relative to other secondary protein structures from the position and shape of the amide I absorption band. Current breeding lines show a substantial variance in this feature and its determination allows the prediction of relative quality for breadmaking to be taken into consideration for subsequent steps in the wheat breeding process. Data treatments include deconvolution, modeling of the individual resulting bands that contribute to the amide I band to enable measurement of the relative amounts of both forms. Results with specimens representing multiple crop years of hard winter wheat breeding are reported. It is evident that a range is available for the breeder to choose from, that allows including this protein molecular structural attribute in the selection process.

43 PARTICLE ACCELERATORS↗

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

High Resolution Imaging of the Sun with CORONAS-1

We applied several image restoration and enhancement techniques, to CORONAS-I images. We carried out the characterization of the Point Spread Function (PSF) using the unique capability of the Blind Iterative Deconvolution (BID) technique, which recovers the real PSF at a given location and time of observation, when limited a priori information is available on its characteristics. We also applied image enhancement technique to extract the small scale structure imbeded in bright large scale structures on the disk and on the limb. The results demonstrate the capability of the image post-processing to substantially increase the yield from the space observations by improving the resolution and reducing noise in the images.

Karovska, Margarita↗

Deconvolution Methods and Systems for the Mapping of Acoustic Sources from Phased Microphone Arrays

Mapping coherent/incoherent acoustic sources as determined from a phased microphone array. A linear configuration of equations and unknowns are formed by accounting for a reciprocal influence of one or more cross-beamforming characteristics thereof at varying grid locations among the plurality of grid locations. An equation derived from the linear configuration of equations and unknowns can then be iteratively determined. The equation can be attained by the solution requirement of a constraint equivalent to the physical assumption that the coherent sources have only in phase coherence. The size of the problem may then be reduced using zoning methods. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with a phased microphone array (microphones arranged in an optimized grid pattern including a plurality of grid locations) in order to compile an output presentation thereof, thereby removing beamforming characteristics from the resulting output presentation.

Brooks, Thomas F.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Stellar Population Properties in the Stellar Streams around SPRC047

Abstract We have investigated the properties (e.g., age, metallicity) of the stellar populations of a ringlike tidal stellar stream (or streams) around the edge-on galaxy SPRC047 (z= 0.031) using spectral energy distribution (SED) fits to integrated broadband aperture flux densities. We used visual images in six different bands and Spitzer/IRAC 3.6μm data. We have attempted to derive best-fit stellar population parameters (metallicity, age) in three noncontiguous segments of the stream. Due to the very low surface brightness of the stream, we have performed a deconvolution with a Richardson–Lucy–type algorithm of the low spatial resolution 3.6μm IRAC image, thereby reducing the effect of the point-spread function aliasedemissionfrom the bright edge-on central galaxy at the locations of our three stream segments. Our SED fits that used several different star formation (SF) history priors, from an exponentially decaying SF burst to continuous SF, indicate that the age–metallicity–dust degeneracy is not resolved, most likely because of inadequate wavelength coverage and low signal-to-noise ratios of the low surface brightness features. We also discuss how future deep visual–near-infrared observations, combined with absolute flux calibration uncertainties at or below the 1% level, complemented by equally well absolute flux-calibrated observations in ultraviolet and mid-infrared bands, would improve the accuracy of broadband SED fitting results for low surface brightness targets, such as stellar streams around nearby galaxies that are not resolved into stars.

Astronomy & Astrophysics↗

Deconvolution methods and systems for the mapping of acoustic sources from phased microphone arrays

A method and system for mapping acoustic sources determined from a phased microphone array. A plurality of microphones are arranged in an optimized grid pattern including a plurality of grid locations thereof. A linear configuration of N equations and N unknowns can be formed by accounting for a reciprocal influence of one or more beamforming characteristics thereof at varying grid locations among the plurality of grid locations. A full-rank equation derived from the linear configuration of N equations and N unknowns can then be iteratively determined. A full-rank can be attained by the solution requirement of the positivity constraint equivalent to the physical assumption of statically independent noise sources at each N location. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with the phased microphone array in order to compile an output presentation thereof, thereby removing the beamforming characteristics from the resulting output presentation.

Brooks, Thomas F.↗

Planck 2013 results. VII. HFI time response and beams

This paper characterizes the effective beams, the effective beam window functions and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is the angular response including the effect of the optics, detectors, data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the cosmic microwave background angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: a) the optical response of the telescope and feeds; b) the processing of the time-ordered data and deconvolution of the bolometric and electronic transfer function; and c) the merging of several surveys to produce maps. The time response transfer functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determined to better than 0.5% at each HFI frequency band. Observations of Jupiter and Saturn limit near sidelobes (within 5°) to about 0.1% of the total solid angle. Time response residuals remain as long tails in the scanning beams, but contribute less than 0.1% of the total solid angle. The bias and uncertainty in the beam products are estimated using ensembles of simulated planet observations that include the impact of instrumental noise and known systematic effects. Here, the correlation structure of these ensembles is well-described by five error eigenmodes that are sub-dominant to sample variance and instrumental noise in the harmonic domain. A suite of consistency tests provide confidence that the error model represents a sufficient description of the data. The total error in the effective beam window functions is below 1% at 100 GHz up to multipole ℓ ~ 1500, and below 0.5% at 143 and 217 GHz up to ℓ ~ 2000.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of limb darkening functions variations on deconvolution of wide-field-of-view measurements of earth emitted radiation

A solution is presented to the problem of deconvolving wide field of view measurements of earth-emitted radiation for the case of limb-darkening functions which are geographically dependent. The method of linear perturbations is used and the effects of limb-darkening function variations at various scales are evaluated. A simple model for the geographical variation of the limb-darkening function based on the radiant exitance is introduced. It is shown that the effect of these variations on the global average radiant exitance vanishes identically, and is insignificant for large spatial scales. For wave numbers six through twelve, the limb-darkening effects are small but possibly significant. At wave numbers greater than twelve, the noise due to meteorological variability dominates for an orbit altitude of 1100 km. The smallness of these effects is due to the smoothness of the monthly averaged radiant exitance field.

Smith, G. L.↗

Locating and Quantifying Broadband Fan Sources Using In-Duct Microphones

In-duct beamforming techniques have been developed for locating broadband noise sources on a low-speed fan and quantifying the acoustic power in the inlet and aft fan ducts. The NASA Glenn Research Center's Advanced Noise Control Fan was used as a test bed. Several of the blades were modified to provide a broadband source to evaluate the efficacy of the in-duct beamforming technique. Phased arrays consisting of rings and line arrays of microphones were employed. For the imaging, the data were mathematically resampled in the frame of reference of the rotating fan. For both the imaging and power measurement steps, array steering vectors were computed using annular duct modal expansions, selected subsets of the cross spectral matrix elements were used, and the DAMAS and CLEAN-SC deconvolution algorithms were applied.

Dougherty, Robert P.↗

Experimental considerations and applications for time-resolved impedance on silicon-anode battery systems

Dynamic electrochemical impedance spectroscopy (dEIS) utilizes a superimposed multi-sinusoidal waveform and enables temporally resolved investigations on various electrochemical processes; however, the signal-to-noise ratio must be maximized while retaining linearity and stationarity within the system. In the present work, we probe the impact of the waveform’s total amplitude as well as the waveform and phase profiles. The equal amplitude multi-sinusoidal waveform with 35 mV total amplitude (<1 mV per frequency) and random phase profile exhibits the lowest impedance noise. This input signal is sufficient in avoiding the high frequency signal attenuation from the potentiostat’s low-pass filter. Additionally, we demonstrate the optimized dEIS waveform’s utility in investigating surface passivation within thin-film and composite silicon (Si) anodes. Within a two-electrode Si-lithium metal coin cell, the charge transfer resistance (RCT) associated with alloying kinetics dominates the overall impedance. RCT increases with state of charge indicating a kinetic bottleneck at higher lithiation states. To explore this further, we utilize a three-electrode Si-LiNi0.8Mn0.1Co0.1O2 pouch cell to deconvolute the Si impedance contributions. The evolution of the solid electrolyte interphase (SEI) and charge transfer resistances correlate to specific Li–Si alloy phases. We attribute this to the influence of Si particle volume expansion on SEI instabilities and a kinetic bottleneck at higher lithiation states.

Lam, Steven [ORNL]↗

Acoustic time-of-flight for proton range verification in water

Purpose: Measurement of the arrival times of thermoacoustic waves induced by pulsed proton dose depositions (protoacoustics) may provide a proton range verification method. The goal of this study is to characterize the required dose and protoacoustic proton range (distance) verification accuracy in a homogeneous water medium at a hospital-based clinical cyclotron. Methods: Gaussian-like proton pulses with 17 μs widths and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 3.4 cGy/pulse at the Bragg peak) were generated by modulating the cyclotron proton source with a function generator. After energy degradation, the 190 MeV proton pulses irradiated a water phantom, and the generated protoacoustic emissions were measured by a hydrophone. The detector position and proton pulse characteristics were varied. The experimental results were compared to simulations. Different arrival time metrics derived from acoustic waveforms were compared, and the accuracy of protoacoustic time-of-flight distance calculations was assessed. Results: A 27 mPa noise level was observed in the treatment room during irradiation. At 5 cm from the proton beam, an average maximum pressure of 5.2 mPa/1 × 10{sup 7} protons (6.1 mGy at the Bragg peak) was measured after irradiation with a proton pulse with 10%–90% rise time of 11 μs. Simulation and experiment arrival times agreed well, and the observed 2.4 μs delay between simulation and experiment is attributed to the difference between the hydrophone’s acoustic and geometric centers. Based on protoacoustic arrival times, the beam axis position was measured to within (x, y) = (−2.0, 0.5) ± 1 mm. After deconvolution of the exciting proton pulse, the protoacoustic compression peak provided the most consistent measure of the distance to the Bragg peak, with an error distribution with mean = − 4.5 mm and standard deviation = 2.0 mm. Conclusions: Based on water tank measurements at a clinical hospital-based cyclotron, protoacoustics is a potential method for measuring the beam’s position (x and y within 2.0 mm) and Bragg peak range (2.0 mm standard deviation), although range verification will require simulation or experimental calibration to remove systematic error. Based on extrapolation, a protoacoustic arrival time reproducibility of 1.5 μs (2.2 mm) is achievable with 2 Gy of total deposited dose. Of the compared methods, deconvolution of the excitation proton pulse is the best technique for extracting protoacoustic arrival times, particularly if there is variation in the proton pulse shape.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-BRE-04: Microbeam-Radiation-Therapy (MRT): Characterizing a Novel MRT Device Using High Resolution 3D Dosimetry

Purpose: The feasibility of MRT has recently been demonstrated utilizing a new technology of Carbon-Nano-Tube(CNT) field emission x-ray sources.This approach can deliver very high dose(10's of Gy) in narrow stripes(sub-mm) of radiation which enables the study of novel radiation treatment approaches. Here we investigate the application of highresolution (50um isotropic) PRESAGE/Optical-CT 3D dosimetry techniques to characterize the radiation delivered in this extremely dosimetrically challenging scenario. Methods: The CNT field emission x-ray source irradiator comprises of a linear cathode array and a novel collimator alignment system. This allows a precise delivery of high-energy small beams up to 160 kVp. A cylindrical dosimeter (∼2.2cm in height ∼2.5cm in diameter) was irradiated by CNT MRT delivering 3 strips of radiation with a nominal entrance dose of 32 Gy.A second dosimeter was irradiated with similar entrance dose, with a regular x-ray irradiator collimated to microscopical strip-beams. 50um (isotropic) 3D dosimetry was performed using an in-house optical-CT system designed and optimized for high resolution imaging (including a stray light deconvolution correction).The percentage depth dose (PDD), peak-to-valley ratio (PVR) and beam width (FWHM) data were obtained and analyzed in both cases. Results: High resolution 3D images were successfully achieved with the prototype system, enabling extraction of PDD and dose profiles. The PDDs for the CNT irradiation showed pronounced attenuation, but less build-up effect than that from the multibeam irradiation. The beam spacing between the three strips has an average value of 0.9mm while that for the 13 strips is 1.5 mm at a depth of 16.5 mm. The stray light corrected image shows line profiles with reduced noise and consistent PVR values. Conclusion: MRT dosimetry is extremely challenging due to the ultra small fields involved.This preliminary application of a novel, ultra-high resolution, optical-CT 3D dosimetry system shows promise, but further work is required to validate and investigate accuracy and artifacts. This work was supported by NIH R01CA100835.

07 ISOTOPE AND RADIATION SOURCES↗

Real-time in Situ Signal-to-noise Ratio Estimation for the Assessment of Operational Communications Links

The work presented here formulates the rigorous statistical basis for the correct estimation of communication link SNR of a BPSK, QPSK, and for that matter, any M-ary phase-modulated digital signal from what is known about its statistical behavior at the output of the receiver demodulator. Many methods to accomplish this have been proposed and implemented in the past but all of them are based on tacit and unwarranted assumptions and are thus defective. However, the basic idea is well founded, i.e., the signal at the output of a communications demodulator has convolved within it the prevailing SNR characteristic of the link. The acquisition of the SNR characteristic is of the utmost importance to a communications system that must remain reliable in adverse propagation conditions. This work provides a correct and consistent mathematical basis for the proper statistical 'deconvolution' of the output of a demodulator to yield a measure of the SNR. The use of such techniques will alleviate the need and expense for a separate propagation link to assess the propagation conditions prevailing on the communications link. Furthermore, they are applicable for every situation involving the digital transmission of data over planetary and space communications links.

Manning, Robert M.↗