Search NASA⌕ Search

SEARCH · Search NASA

Results for “O-ring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Optical-Fiber Leak Detector

Proposed optical-fiber sensor detects small changes in pressure in elastomeric O-ring or similar pressure seal, which may indicate deterioration of seal and interpreted as indications of incipient failure. According to concept, length of optical fiber embedded in seal. Light-emitting diode illuminates one end of fiber; photodetector measures intensity of light emerging from other end. Pressure-induced changes in seal bend fiber slightly, altering microbending-induced loss of light from fiber and alter intensity of light at photodetector. Change in intensity approximately proportional to change in pressure.

Workman, Gary L.↗

STS-55 pad abort: Engine 2011 oxidizer preburner augmented spark igniter check valve leak

The STS-55 initial launch attempt of Columbia (OV102) was terminated on KSC launch pad A March 22, 1993 at 9:51 AM E.S.T. due to violation of an ME-3 (Engine 2011) Launch Commit Criteria (LCC) limit exceedance. The event description and timeline are summarized. Propellant loading was initiated on 22 March, 1993 at 1:15 AM EST. All SSME chill parameters and launch commit criteria (LCC) were nominal. At engine start plus 1.44 seconds, a Failure Identification (FID) was posted against Engine 2011 for exceeding the 50 psia Oxidizer Preburner (OPB) purge pressure redline. The engine was shut down at 1.50 seconds followed by Engines 2034 and 2030. All shut down sequences were nominal and the mission was safely aborted. The OPB purge pressure redline violation and the abort profile/overlay for all three engines are depicted. SSME Avionics hardware and software performed nominally during the incident. A review of vehicle data table (VDT) data and controller software logic revealed no failure indications other than the single FID 013-414, OPB purge pressure redline exceeded. Software logic was executed according to requirements and there was no anomalous controller software operation. Immediately following the abort, a Rocketdyne/NASA failure investigation team was assembled. The team successfully isolated the failure cause to the oxidizer preburner augmented spark igniter purge check valve not being fully closed due to contamination. The source of the contaminant was traced to a cut segment from a rubber O-ring which was used in a fine clean tool during valve production prior to 1992. The valve was apparently contaminated during its fabrication in 1985. The valve had performed acceptably on four previous flights of the engine, and SSME flight history shows 780 combined check valve flights without failure. The failure of an Engine 3 (SSME No. 2011) check valve to close was sensed by onboard engine instruments even though all other engine operations were normal. This resulted in an engine shutdown and safe sequential shutdown of all three engines prior to ignition of the solid boosters.

Source record↗

Return to Space

This video documents the preparations for Shuttle Flight STS-26 with Shuttle Discovery, NASA's return to manned space flight after the Challenger disaster. Footage and descriptions document such changes to the new Shuttle as new joints, improved insulation, and added O-rings to the solid rocket boosters; new safety hardware and procedures such as parachute and sidewire evacuations during liftoff, and new pressure suits; modified landing gear, brakes, and nose wheel steering, as well as a modified landing runway. Also profiled are the 5 member crew of all veteran Shuttle astronauts, the TDRS 3 Satellite to be released from the cargo bay in orbit, and 11 commercial and student experiments to be performed during the mission.

Source record↗

EG and G and NASA face seal codes comparison

This viewgraph presentation presents the following results for the example comparison: EG&G code with face deformations suppressed and SPIRALG agree well with each other as well as with the experimental data; 0 rpm stiffness data calculated by EG&G code are about 70-100 percent lower than that by SPIRALG; there is no appreciable difference between 0 rpm and 16,000 rpm stiffness and damping coefficients calculated by SPIRALG; and the film damping above 500 psig calculated by SPIRALG is much higher than the O-Ring secondary seal damping (e.g. 50 lbf.s/in).

Basu, Prit↗

BSM Delta Qualification 2, volume 3, book 2

This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into booster separation motor (BSM0 flight hardware: vulcanized-in-place nozzle aft closure insulation; new iso-static ATJ bulk graphite throat insert material, adhesive EA9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; deletion of the igniter adapter insulator ring; deletion of the igniter adapter/igniter case interface RTV; and deletion of loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM total quality management (TQM) team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor testing--consisting of two motors, randomly selected by USBI's on-site quality personnel from production lot AAY, which were modified to accept the enhancements -- was completed to provide the final qualification of the enhancements for incorporation into flight hardware. Volume 3, Book 2 provides various supporting documentation to the previous volumes with regards to the testing of the two Delta qualification units: data acceptance records, thermal conditioning analysis, igniter adapter thermal flake analysis, laboratory adhesive (EA-9394) qualification report, throat insert thermal/structural analysis, Delta Qualification Nonconformance Reports (NCR's), O-ring seating tests, and interim test report for vulcanization process qualification.

Source record↗

Analysis of selected specimens from the STS-46 Energetic Oxygen Interaction with Materials-3 experiment

The Energetic Oxygen Interaction with Materials 3 (EOIM-3) experiment was flown on the STS-46 mission, which was launched on 31 Jul. 1992 and returned 8 Aug. 1992. Boeing specimens were located on both the NASA Marshall Space Flight Center (MSFC) tray and the Ballistic Missile Defense Organization (BMDO) tray integrated by the Jet Propulsion Laboratory (JPL). The EOIM-3 pallet was mounted in the Space Shuttle payload bay near the aft bulkhead. During the mission, the atomic oxygen (AO) exposure levels of specimens in these passive sample trays was about 2.3 x 10(exp 20) atoms/sq cm. The specimens also received an estimated 22 equivalent sun hours of solar exposure. In addition, it appears that the EOIM-3 pallet was exposed to a silicone contamination source and many specimens had a thin layer of silicon based deposit on their surfaces after the flight. The specimens on the MSFC tray included seven solid film lubricants, a selection of butyl rubber (B612) and silicone (S383) o-rings, three indirect scatter surfaces, and Silver/Fluorinated Ethylene Propylene (Ag/FEP) and Chemglaze A276 specimens which had previously flown on trailing edge locations of the Long Duration Exposure Facility (LDEF). The specimens on the JPL tray included composites previously flown on LDEF and two indirect scattering surfaces.

Golden, Johnny L.↗

Water driven turbine/brush pipe cleaner

Assemblies are disclosed for cleaning the inside walls of pipes and tubes. A first embodiment includes a small turbine with angled blades axially mounted on one end of a standoff support. An O-ring for stabilizing the assembly within the pipe is mounted in a groove within the outer ring. A replaceable circular brush is fixedly mounted on the opposite end of the standoff support and can be used for cleaning tubes and pipes of various diameters, lengths and configurations. The turbine, standoff support, and brush spin in unison relative to a hub bearing that is fixedly attached to a wire upstream of the assembly. The nonrotating wire is for retaining the assembly in tension and enabling return of the assembly to the pipe entrance. The assembly is initially placed in the pipe or tube to be cleaned. A pressurized water or solution source is provided at a required flow-rate to propel the assembly through the pipe or tube. The upstream water pressure propels and spins the turbine, standoff support and brush. The rotating brush combined with the solution cleans the inside of the pipe. The solution flows out of the other end of the pipe with the brush rotation controlled by the flow-rate. A second embodiment is similar to the first embodiment but instead includes a circular shaped brush with ring backing mounted in the groove of the exterior ring of the turbine, and also reduces the size of the standoff support or eliminates the standoff support.

Werlink, Rudy J.↗

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.↗

Soft Wire Seals For High Temperatures And Pressures

Soft metal wires used to make O-ring and similar seals for vessels, flanges, and fittings subject to pressures equal to or greater than 1,000 psi and temperatures equal to or greater than 100 degrees C. Seals containing soft metal wires made inexpensively because fabricated to looser tolerances like those of lower-temperature, lower-pressure elastomeric-O-ring seals, which they resemble. Seals also made with noncircular grooves and with soft metals other than aluminum. For example, gold performs well, though expensive. For other applications, silver good choice.

Tsou, Peter↗

Functional Performance of Pyrovalves

Following several flight and ground test failures of spacecraft systems using single-shot, 'normally closed' pyrotechnically actuated valves (pyrovalves), a government/industry cooperative program was initiated to assess the functional performance of five qualified designs. The goal of the program was to improve performance-based requirements for the procurement of pyrovalves. Specific objectives included the demonstration of performance test methods, the measurement of 'blowby' (the passage of gases from the pyrotechnic energy source around the activating piston into the valve's fluid path), and the quantification of functional margins for each design. Experiments were conducted in-house at NASA on several units each of the five valve designs. The test methods used for this program measured the forces and energies required to actuate the valves, as well as the energies and the pressures (where possible) delivered by the pyrotechnic sources. Functional performance ranged widely among the designs. Blowby cannot be prevented by o-ring seals; metal-to-metal seals were effective. Functional margin was determined by dividing the energy delivered by the pyrotechnic sources in excess to that required to accomplish the function by the energy required for that function. All but two designs had adequate functional margins with the pyrotechnic cartridges evaluated.

Bement, Laurence J.↗

A new RF package suitable for aeronautical commercial and DSCS satellite applications

Higher levels of integration through the use of GaAs and silicon MMIC devices, a die-cast housing, and the reduction of the number of subassemblies has enabled a large reduction of the size and weight of the electronics package for commercial and military satellite communications. This paper presents an electronics architecture and hardware that utilizes many new integrated circuits and design techniques, and allows flexibility for future satellite frequency changes and expansion. Key features of the radio are extended C-band, InSat, Defense Satellite Communications System (DSCS), and Ku-band coverage options; 70 (or 140) MHz transponder bandwidth or L-band block bandwidth IFs; integrated RS-232 control through local handheld terminal or remote computer; remote control of crystal reference oscillator for aging and temperature compensation; integrated 2 or 5 watt solid-state power amplifiers (SSPA); optional integrated solid-state booster amplifiers to 40 watts; optional external amplifiers to 100 watts; integral beacon tracking with second integrated downcoverter for antenna positioning; radio, including low-noise block converter (LNB) and SSPA, weighs 8.5 kg and measures 32 x 23 x 16.5 cm; environmentally ruggedized for -40 to +60 C; O-ring sealed for waterproofing; passive (convection) cooling; and simple cabling and installation, with a single cable between radio and LNB, and two cables between radio and IF interface. The small size and light weight of the radio make it ideal for mounting on stabilized antenna platforms (gyroscopic or servo). Several input power options (110 or 220 VAC; +48, +12, or -24 VDC) facilitate operation on multiple platforms.

Hamilton, Robert J., Jr.↗

Functional performance of pyrovalves

Following several flight and ground test failures of spacecraft systems using single-shot, 'normally closed' pyrotechnically actuated valves (pyrovalves), a Government/Industry cooperative program was initiated to assess the functional performance of five qualified designs. The goal of the program was to provide information on functional performance of pyrovalves to allow users the opportunity to improve procurement requirements. Specific objectives included the demonstration of performance test methods, the seating; these gases/particles entered the fluid path of measurement of 'blowby' (the passage of gases from the pyrotechnic energy source around the activating piston into the valve's fluid path), and the quantification of functional margins for each design. Experiments were conducted at NASA's Langley Research Center on several units for each of the five valve designs. The test methods used for this program measured the forces and energies required to actuate the valves, as well as the energies and the pressures (where possible) delivered by the pyrotechnic sources. Functional performance ranged widely among the designs. Blowby cannot be prevented by o-ring seals; metal-to-metal seals were effective. Functional margin was determined by dividing the energy delivered by the pyrotechnic sources in excess to that required to accomplish the function by the energy required for that function. Two of the five designs had inadequate functional margins with the pyrotechnic cartridges evaluated.

Bement, Laurence J.↗

Space Shuttle Solid Rocket Nozzle Joint 2 Gas Path Study

Each Space Shuttle solid rocket nozzle contains five joints. By design, each nozzle joint utilizes room-temperature vulcanized (RTV) rubber as a thermal barrier to protect the nozzle metal parts and O-rings from heat degradation due to motor combustion gas. Typically, combustion gas does not penetrate through the RTV in nozzle Joints. However, Joint currently experiences gas penetration through the RTV over 90 percent of the time. The occurrence of Joint gas paths is a very complex phenomenon with several known contributors such as the unique geometry of the joint, motor pressure, nozzle vectoring, manufacturing induced RTV voids. RTV material capability, and joint skip (relative radial displacement of joint components). The occurrence of Joint gas paths appears to be a combination of these causes. To better understand the causes of gas paths in Joint, the circumferential locations of gas paths in the RTV were identified and correlated with nozzle vectoring, RTV closeour locations (where the RTV backfill is completed), and X-ray low-density. anomaly (LDA) indications. Results that no specific cause was determined.

Lui, R. C.↗

Effect of Altered Gravity Environment on Tobacco Hornworm (Manduca Sexta) Development

Metamorphosis provides a unique condition for studying the role of gravity in development. Formation of new organs in a previously existing organism requires a highly active period of turnover of amino acids and proteins, and of changes in the endocrine profile. Furthermore, metamorphosis offers the advantage of studying a self-contained biological system. The tobacco hornworm provides a suitable species to study the effect of altered gravitational environment on invertebrate development. This species has been one of the most thoroughly investigated organisms in a variety of aspects of insect biology. M. sexta pharate adults can provide significant amounts of material with which to work, thus facilitating the study of metabolic aspects of adult development. During wandering, the period immediately following cessation of larval feeding, the larva burrows into the soil to form a pupation chamber. Despite burrowing down 25 to 30 cm, the insects reorient themselves to a slightly head-up (10 +/- 1 degree) position. Since light and temperature are not factors in this process, the larvae must sense the gravity vector. In our ground-based studies we had assessed whether developing adults might be sensitive to their gravitational environment by orienting pupae in a vertical head-up position within 24 to 48 h after pupal ecdysis. Our ground-based findings formed the foundation for determining which parameters would be evaluated in developing Manduca following spaceflight. Measurements were to include: (1) extent of development by all of the insects, (2) analysis of hemolymph obtained from half of the insects postflight for ecdysteroid, amino acid, urea, ammonia and trehalose concentrations, (3) further development of the other half of the insects to adult (moths), (4) analysis of the flight muscle protein content of the adults. Based on the first flight attempt in July, 1995, we modified the BRIC hardware to accommodate the insects. Our studies after BRIC-04 showed that sealing the top and bottom lids of the canisters with an 0-ring and with vacuum grease caused the insects to stop developing because of accumulation of carbon dioxide. Even though removing both the O-rings and vacuum grease permitted normal development, there was still some increase in carbon dioxide levels. Consequently, the canisters were vented and the vents covered with gas permeable membrane.

Tischler, Marc E.↗

Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

Lueders, Kathy↗

Design and Development of Lightweight Composite Tanks for the Mars Ascent Propulsion Technology

The investigation presented here focuses on the design and development of lightweight composite tanks for the Mars ascent propulsion technology. The proposed tanks are fabricated using the filament winding technique. The tanks will be used in the experimental permeability characterization of composite pressure vessels pressurized using cryogenic and kerosene fluids. We considered the geometry and composite material tailorability in the preliminary design formulation to obtain an isotensoid tank. The design formulation is based on membrane shell analysis. The tanks also include circular openings at the apex of the end caps for the installation of polar bosses. The development of a polar boss system was also investigated, and led to an innovative polar boss system that applies a uniform pressure on the o-ring gaskets. The permeability of these tanks was also considered and recommendations for improvement are presented.

Estrada, Hector↗

Laboratory Tool

Veterans Administration medical researchers, along with Langley Research Center are investigating possibility that peritoneal membrane (lining of abdominal cavity) can absorb nutrients and thus provide alternative route for nutrition when intestinal function is impaired. Apparatus (cake box design) consists of octagonal chamber with eight smaller chambers attached and secured by O-ring seals. Design is simple, interchangeable, and time controllable.

Source record↗

Ampoule sealing apparatus and process

An apparatus 10 for effecting sealing of a fused quartz ampoule 24 while maintaining a vacuum on the ampoule via system 12 is disclosed. A plug 28 of fused quartz is lowered into the vertically disposed ampoule 24 (while maintaining the vacuum thereon) and heat sealed therein to prevent any vapor escape from, or contamination of, the contained semiconductor growth charge 29 during subsequent semiconductor crystal growth processes. A rotary vacuum feed-through mechanism 16 selectively rotates axle 34 and spool 32 to unwind wire 30 for lowering of plug 28 into the reduced diameter portion 24b of ampoule 24. Ampoule 24 is hermatically connected to vacuum housing 18 by quick release flange 20 wherein O-ring 22 retains ampoule 24.

Debnam, Jr., William J.↗