Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL COUPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Computer quantitation of coronary angiograms

A computer technique is being developed at the Jet Propulsion Laboratory to automate the measurement of coronary stenosis. A Vanguard 35mm film transport is optically coupled to a Spatial Data System vidicon/digitizer which in turn is controlled by a DEC PDP 11/55 computer. Programs have been developed to track the edges of the arterial shadow, to locate normal and atherosclerotic vessel sections and to measure percent stenosis. Multiple frame analysis techniques are being investigated that involve on the one hand, averaging stenosis measurements from adjacent frames, and on the other hand, averaging adjacent frame images directly and then measuring stenosis from the averaged image. For the latter case, geometric transformations are used to force registration of vessel images whose spatial orientation changes.

Ledbetter, D. C.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Design and performance of the solar maximum mission Hard X-ray Burst Spectrometer

The Hard X-ray Burst Spectrometer acquires data on the temporal and energy distribution of solar X-rays in the energy region from 25 to 385 keV. The detector system is a CsI(Na) central detector, and an anti-coincidence shield with photomultiplier tubes optically coupled to the central and shield crystals. Additional detectors are included for calibration and South Atlantic Anomaly monitoring. A 15 channel pulse height analysis is performed over the energy range every 128 milliseconds. This instrument is capable of handling event rates up to 500 kHz and provides high rate data up to 100 kHz with low spectral distortion. Nine accumulated rates are telemetered every 8.192 seconds. A unique feature of the instrument is the ability to sample rates from the central detector or shield with a one millisecond minimum time resolution. Such samples are stored in a 32768 sample memory with a 40 percent pretrigger event history and a 60 percent posttrigger history.

Workman, L. G.↗

Images of single X-ray photons from X-ray phosphor screens

Photographs show the efficiency and resolution characteristics of single X-ray photons converted to optical photons in a variety of commercial X-ray phosphor screens. The recording system uses a cooled, two-stage image intensifier system with fiber optics coupling to the phosphor screen. High efficiencies in the energy range 20-100 keV with position resolution of the order 200 microns are readily achievable, although the sensitive area is presently limited. Potential applications include X-ray astronomy, high-speed X-ray diffractometry, and extremely low dose radiography.

Fishman, G. J.↗

Spectroscopic observations of comets

Development of a spectrograph using a microchannel plate intensifier for observing faint comets is described. The spectrograph is capable of obtaining useful spectra of objects as faint as M(2) = 18. The increased guiding efficiency achieved by the optical coupling of the ISIT vidicon of the 154 cm telescope has resulted in a better signal to noise ratio. The ability to take a direct image of the comet aids in the interpretation of the spatial profile of the emissions. Spectra of comets Schwassmann-Wachmann 1, Bradfield, Encke, Tuttle, and Stephen-Oterma are discussed.

Source record↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗

Low intensity X-ray and gamma-ray spectrometer

A low intensity X-ray and gamma ray spectrometer for imaging, counting, and energy resolving of single invisible radiation particles is described. The spectrometer includes a converting device for converting single invisible radiation particles to visible light photons. Another converting device converts the visible light photons to photoelectrons. A fiber optics coupling device couples together the two converting devices. An intensifying device intensifies the photoelectrons by an average gain factor of between 10 to the 4th power and 10 to the 7th power. The tensifying device is an anti-ion feedback microchannel plate amplifier which is operated substantially below saturation. A displaying device displays the intensified photoelectrons. The displaying device 32 indicates the spatial position, number, and energy of the incoming single invisible radiation particles.

Yin, L. I.↗

Laser processing of silicon solar cells

Results of a study to utilize an Nd:glass laser for production line annealing of ion implantation induced damage in solar cells are reported. Czochralski-grown and sawn Si wafers 7.6 cm in diam, 0.35 mm thick, were implanted with phosphorus junctions and boron BSFs. Annealing with electron beam, laser, and firing of an Al paste to form the BSFs in different cells was compared. The laser was employed at 1.06 and 0.53 micron and in combination of both, with a 20-50 nsec pulsewidth, and energy densities of 1.2, 1.5, 1.9, and 2.1 J/sq cm. Best optical coupling was observed with the combined wavelengths and a 20 nsec pulse, using energy densities less than 1.5 J/sq cm. Although the Al sintered cells displayed the best characteristics, laser annealing is concluded to offer electrically active, defect-free, shallow junction Si substrates for high efficiency cells.

Katzeff, J. S.↗

A software system for emission spectrometry

A computer system was developed for an emission spectrometry facility consisting of a direct current (DC) argon arc spectrograph optically coupled to an inductively coupled plasma multichannel spectrometer. Custom hardware and software were designed to control analytical functions and perform data acquisition. The software system was designed to make operation of the facility simple for routine operation and flexible for research and development. Special software was written to collect data under controlled conditions to characterize and monitor system response. One sequence collects intensity versus time data on all channels and displays the data graphically. These profiles are useful in studying the effects of operating parameters on measurement precision. Another special sequence performs calibration using a spline curve fit procedure. Routines were also written to measure dark currents and signals from a standard tungsten halogen lamp mounted in place of the DC arc. For quality control purposes, histories of these values are kept and monitored for excess scatter or drift.

Auping, J. V.↗

The application of encapsulation material stability data to photovoltaic module life assessment

For any piece of hardware that degrades when subject to environmental and application stresses, the route or sequence that describes the degradation process may be summarized in terms of six key words: LOADS, RESPONSE, CHANGE, DAMAGE, FAILURE, and PENALTY. Applied to photovoltaic modules, these six factors form the core outline of an expanded failure analysis matrix for unifying and integrating relevant material degradation data and analyses. An important feature of this approach is the deliberate differentiation between factors such as CHANGE, DAMAGE, and FAILURE. The application of this outline to materials degradation research facilitates the distinction between quantifying material property changes and quantifying module damage or power loss with their economic consequences. The approach recommended for relating material stability data to photovoltaic module life is to use the degree of DAMAGE to (1) optical coupling, (2) encapsulant package integrity, (3) PV circuit integrity or (4) electrical isolation as the quantitative criterion for assessing module potential service life rather than simply using module power loss.

Coulbert, C. D.↗

Stable Optocoupler

Circuit stabilizes current-transfer ratio (CTR) of optically coupled isolator used as linear transducer. New circuit employs feedback circuit containing second optocoupler. Circuit is inexpensive, requires little additional hardware.

Griffin, D. J.↗

On 3He bolometer systems

A 3He cryostat which was constructed to cool a germanium bolometer for use as an infrared detector at submillimeter wavelength is discussed. The system had better sensitivity than any other existing system for these wavelengths; the system could be improved if better optical coupling could be achieved between the bolometer and the incoming photon stream. Considerable effort was expended to improve this coupling. Even the best results however, fell short of an ideal system by a factor of nearly 5 in coupling efficiency.

Houck, J. R.↗

Research directions and progress in SERI advanced high efficiency concepts program

Novel solar cell designs and materials with the objective of achieving the maximum attainable photovoltaic conversion efficiencies are researched. Laboratory demonstrations of solar cells of greater than 30% efficiency under concentrated sunlight and thin film solar cells with one sun efficiencies of 17 to 20% are sought. These demonstrations are necessary intermediate steps towards the realization of very high efficiency, multi-bandgap, thin-film solar cells. Conversion efficiencies above 30% could be achieved by a cascade multijunction cell consisting of a high bandgap (1.7 eV) cell coupled optically and electrically on top of a lower bandgap (1.1 eV) cell. Recent improvements in peak currents of this interconnect are quite promising. However, this cell structure poses difficult problems for materials fabrication as a result of the combined requirements of choice of bandgaps, low defect density material, and high doping densities. Recent improvements in the quality of materials and newly proposed cell structures which may simplify fabrication are significant steps in the development of the multijunction concentrator solar cell.

Benner, J. P.↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

A V-grooved AlGaAs/GaAs passivated PN junction

A passivated, V-grooved GaAs solar cell offers important advantages in terms of improved optical coupling, higher short circuit current, and increased tolerance to particle radiation when compared to the planar cell configuration. An AlGaAs epilayer has been deposited on a p-type GaAs epilayer grown on an n-type V-grooved GaAs surface using MOCVD. A wet chemical etching process was used to produce a V-pattern with a 7.0 micron periodicity. Reflectivity measurements substantiate the expected decrease in solar reflectance. Scanning electron microscopy techniques were used to confirm the presence of the AlGaAs layer and verify the existence of a pn junction.

Bailey, Sheila G.↗

High angle of attack position sensing for the Southampton University magnetic suspension and balance system

An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

Parker, David H.↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

The UCB/MPE Cassegrain Submillimeter Heterodyne Spectrometer

The UCB/MPE Submillimeter Heterodyne Spectrometer is a system for astronomical spectroscopy in the high-frequency atmospheric windows from 500 to 1000 GHz. It contains a molecular laser local oscillator, a cooled Schottky open structure mixer, a quasi-optical coupling system, and an acoustooptical spectrometer. The compact receiver mounts at the Cassegrain focus of large infrared astronomical telescopes. The receiver noise temperature on the telescope is approximately 3500 K (DSB) during observations of the CO J = 7-6 line at 806.652 GHz. The spectrometer's frequency resolution and instantaneous bandwidth (less than 2 MHz resolution across 1.1 GHz) are well suited for observations of molecular emission lines from a variety of astronomical sources.

Harris, A. I.↗