Search NASA⌕ Search

SEARCH · Search NASA

Results for “OXYGEN CONSUMPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Influences of chemical sympathectomy and simulated weightlessness on male and female rats

Consideration is given to a study aimed at determining whether the sympathetic nervous system is associated with the changes in maximum oxygen consumption (VO2max), run time, and mechanical efficiency observed during simulated weightlessness in male and female rats. Female and male rats were compared for food consumption, body mass, and body composition in conditions of simulated weightlessness to provide an insight into how these parameters may influence aerobic capacity and exercise performance. It is concluded that chemical sympathectomy and/or a weight-bearing stimulus will attenuate the loss in VO2max associated with simulated weightlessness in rats despite similar changes in body mass and composition. It is noted that the mechanisms remain unclear at this time.

Woodman, Christopher R.↗

Engineering verification of the biomass production chamber

The requirements for life support systems, both biological and physical-chemical, for long-term human attended space missions are under serious study throughout NASA. The KSC 'breadboard' project has focused on biomass production using higher plants for atmospheric regeneration and food production in a special biomass production chamber. This chamber is designed to provide information on food crop growth rate, contaminants in the chamber that alter plant growth requirements for atmospheric regeneration, carbon dioxide consumption, oxygen production, and water utilization. The shape and size, mass, and energy requirements in relation to the overall integrity of the biomass production chamber are under constant study.

Prince, R. P.↗

Myosin heavy chain composition in the rat diaphragm - Effect of age and exercise training

The effects of aging and exercise training on the myosin heavy chain (MHC) composition were determined in both the costal and crural diaphragm regions of female Fischer 344 rats. Treadmill running at 75 percent maximal oxygen consumption resulted in similar increases in plantaris muscle citrate synthase activity in both young (5 mo) and old (23mo) trained animals (P less than 0.05). It was found that the ratio of fast to slow MHC was significantly higher (P less than 0.005) in the crural compared with costal diaphragm region in both age groups. A significant age-related increase in persentage of slow MHC was observed in both diaphragm regions. The relative proportion of slow MHC in either costal or crural region was not changed by exercise training.

Gosselin, Luc E.↗

Variability of prediction of maximal oxygen concumption on the cycle ergometer using standard equations

Several investigations within the Exercise Countermeasures Project at the NASA Johnson Space Center focused on the assessment of maximum oxygen consumption (VO2(sub max)) within the Astronaut Corps pre- and postspace flight. Investigations during the Apollo era suggested that there was a significant decrease in postflight VO2(sub max) when compared to preflight values, and current studies have documented that this trend continues in the Space Shuttle era. It is generally accepted and was confirmed in our laboratory that VO2(sub max) can be predicted from submaximal measures taken during graded exercise tests on the cycle ergometer with respect to populations. However, previous work had not examined the effect of day-to-day variations in the physiologic responses that might alter these predictions for individuals. Stability of individual submaximal data over serial tests is important so that predicted changes in VO2(sub max) are reflective of actual VO2(sub max) changes. Therefore, the purpose of this investigation was to determine which of the accepted equations to predict VO2(sub max) would be less affected by normal daily physiologic changes.

Greenisen, Michael C.↗

Plasma volume shifts and exercise thermoregulation with water immersion and six-degree head-down tilt

The hypothesized fluid shifts and resultant responses that occur during spaceflight are simulated by six-degree head down tilt (HDT) and water immersion (WI). The purpose of this study was to compare exercise thermoregulation before and after physiologic mechanisms reduce plasma volume (PV) in response to 24-hr HDT (HDT24). A secondary study utilized WI to reproduce the PV reduction of HDT24. Seven males were studied in two conditions: during 70 minutes of supine cycling ergometry at 58 percent of peak oxygen consumption following 1-hr HDT (HDT1) and HDT24; and up to 6 hr WI at 34.5 C. Plasma volume was reduced by 10.4 percent in HDT24 when compared to HDT1. Pre-exercise rectal temperature, T(sub re), was an average 0.22 C higher after HDT24. Rectal temperature increased during exercise with no interaction between time and treatment. The reduced PV and elevated pre-exercise T(sub re) had offsetting effects on thermoregulatory mechanisms, suggesting no alteration in the response at a given T(sub re). Plasma volume was reduced by 4.3 +/- 2.3 percent and 1.1 +/- 1.8 percent following HDT24 and WI, respectively, compared to upright chair rest. Although the reductions in PV were not significantly different, great intra-individual variability was evident. The ability to reproduce PV changes consistently with HDT and WI is limited by this variability.

Ertl, Andrew Carl↗

Intermittent gravity: How much, how often, how long?

Continuous exposure to gravity may not be necessary to prevent the deconditioning effects of microgravity. It is not known, however, what the minimum gravity (G) exposure reguirements are, whether they vary for different physiological systems, or whether passive Gz (gravity in the head-to-toe vector) or activity in a G field is more effective in preventing deconditioning. It is also not known what the optimal characteristics of the G stimulus should be in terms of amplitude, duration, and frequency. To begin to address these questions, a 4-day -6 deg head-down bed rest (HDBR) study was conducted. Nine males (aged 30-50 yr) were subjected, over a period of seven months, to four different +1 Gz exposure protocols (periodic standing or controlled walking each for a total of 2 or 4 hr/day in individual 15-min doses), plus a control (0 Gz) of continuous HDBR. The study consisted of one ambulatory control day, 4 full days of -6 deg HDBR, and a recovery day when subjects were released at the end of HDBR after completion of tests. A battery of tests was selected and standardized in order to evaluate the known early responses to HDBR. Dependent variables of interest included orthostatic tolerance (30 min at 60 deg head-up tilt) and hemodynamics during head-up tilt, peak oxygen consumption (VO2(sub peak)) plasma volume (PV), and urinary calcium (Ca). The results were as follows: 4 hr standing completely prevented and 2 hr walking partially prevented post-HDBR orthostatic intolerance. Walking at 3 mi/hr for 4 hr/day provided no additional benefit. Intermittent walking attenuated, but did not prevent, the decrease in VO2(sub peak). Both 4 hr conditions showed less PV loss by the end of HDBR; both 2 hr conditions were without effect. Both 2 and 4 hr walking essentially prevented urinary Ca excretion and were more effective than standing. It is concluded that different physiological systems benefit differentially from passive +1 Gz or activity in +1 Gz, and the intensity of the stimulus may be an important contributing factor.

Vernikos, Joan↗

Dual-cycle ergometry as an exercise modality during prebreathe with 100 percent oxygen

In an effort to reduce prebreathe time requirements prior to extravehicular activities and high-altitude flights, a combined arm and leg exercise task proposes to enhance denitrogenation by incorporation of both upper and lower body musculature at a moderately high work intensity during prebreathe with 100% oxygen. Preliminary findings indicated peak oxygen consumption (VO2peak) levels attained on the dual-cycle ergometer do not differ significantly from those levels attained on the treadmill. Eight male subjects were exercised to VO2peak using leg-only cycle ergometry and dual-cycle ergometry on separate days. Preliminary data during dual-cycle ergometry showed arm work equaling 30% of the leg workrate at each stage of the incremental test resulted in arm fatigue in several subjects and a reduced VO2peak compared to dual-cycle ergometry with arm work at 20%. Thus, the 20% workrate was used during the dual-cycle VO2peak trial. On a third experimental day, subjects performed a 10 minute exercise test at a workrate required to elicit 75% of VO2peak for each subject on the dual-cycle ergometer. Blood lactate response to the exercise was monitored as an objective measure of fatigue. Peak VO2 levels attained on the leg-only and the dual-cycle ergometry tasks were not significantly different. Blood lactate levels were significantly elevated following the dual-cycle ergometry at 75% VO2peak. However, lactate levels show the expected rate of decline during recovery and, as demonstrated in the literature, should return to baseline levels within 30 minutes following exercise cessation. Thus, dual-cycle ergometry at 75% VO2peak appears to be a valid exercise for use during prebreathe and should not contribute to fatigue during subsequent EVA's.

Heaps, Cristine L.↗

Effect of decreased gravity on circulation in the rat

It has been reported that hypokinesia and bed rest induce cardiovascular changes similar to those observed in space flights. Using an animal model that was developed in our laboratory and that was extensively studied and characterized in our laboratory and other laboratories in this country and abroad, we have studied circulatory mechanisms that occur during exposure to hypokinesia (with or without negative tilt) as well as during readaptation to control conditions (free activity). We believe that this study contributes to better understanding of mammalian circulatory mechanisms that operate under 1-g force and will serve to provide control data to be compared with cardiovascular data obtained in conditions of a Space lab. Because survey and anesthesia drastically decrease cardiac output and other circulatory parameters in rats, only unanesthetized rats were used in experiments. Aorta and right atrium of the animals were permanently cannulated fifteen to twenty days before experiments. Arterial and right ventricular blood pressures, cardiac output, cerebral and other regional blood flow, ECG, other cardiovascular parameters, and oxygen consumption were measured with techniques routinely used in our laboratory. Specifically, we undertook the following investigations during the period of three years: (1) A study of circulatory changes (right ventricular pressure, arterial blood pressure, heart rate, cardiac output) during exposure of rats to hypokinetic conditions. Used the head down tilted Holton-Musacchia system in order to compare the results with the results already obtained on unrestrained rats, (2) Humoral changes were investigated in animals exposed to hypokinesia; also, lymphocyte and neutrophil levels in hypokinetic animals (with or without tilt) were determined to ascertain the level of induced stress and possible changes observed in weightless animals, and (3) circulating blood volume was determined during and after hypokinesia.

Popovic, Vojin P.↗

The value of the 4-day headdown bedrest model for screening countermeasures

In order to evaluate the benefits of periodic exposure to the +G(z) vector as a countermeasure to the physiological responses to minus 6 degree head down bedrest (HDT), we considered a two-tiered approach: (a) to use 4 days HDT as a quick and inexpensive means of screening countermeasures, (b) to use a 60 day HDT to validate the most promising candidates. The approach and results of a 4 day study are described here. Methods: Nine males were admitted to our Human Research Facility for one ambulatory control day followed by 4 days HDT and were released on the next day after completion of a peak oxygen consumption test (VO(sub 2 peak)). A battery of tests was selected and standardized to evaluate the known early effects of HDT on plasma volume, early bone markers, orthostatic tolerance, physical performance, and fluid and electrolytes and their hormone regulation. Fluid sodium (Na) and potassium (K) intake and output in the urine were monitored throughout. Plasma volume was determined with a modified Evans Blue method and orthostatic tolerance with a 60 degree head-up tilt test for 30 minutes - both of which were determined on the ambulatory control day and on day 4 of HDT. Immediately after completion of the tilt test subjects were returned to the minus 6 degree position until the next morning when a VO(sub 2 peak) (horizontal ergometer) was done. This was compared to a similar control test determined on 2 separate occasions before subject admission. Results: Four hours after going HDT produced significant decreases (p less than 0.05) in the circulating concentration of fluid and electrolyte regulating hormones. Plasma volume, orthostatic tolerance and VO(sub 2 peak) changed significantly after 4 days HDT. There was also the expected natriuresis on day 1 of HDT but no significant diuresis. The consistency of the pre-bedrest VO(sub 2 peak) tilt tests and plasma volumes was remarkable. Conclusions: The 4 day HDT model seems highly promising for screening a variety of countermeasures alone and in combination before validating their benefits in extended bedrest or flight experiments.

Vernikos, J.↗

Light and Gravity Effects on Circadian Rhythms of Rhesus Macaques

Temporal integration of a biological organism's physiological, behavioral and biochemical systems depends upon its circadian timing system. The endogenous period of this timing system is typically synchronized to the 24- hour day by environmental cues. The daily alternation of light and dark has long been known as one of the most potent environmental synchronizers influencing the circadian timing system. Alterations in the lighting environment (length or intensity of light exposure) can also affect the homeostatic state of the organism. A series of experiments was performed using rhesus monkeys with the objective of defining the fundamental properties of the circadian rhythm of body temperature. Three major experiments were performed in addition to several preliminary studies. These experiments explored 1.) the response of the rhesus body temperature rhythm to varying day length and light intensity; 2.) the response of the body temperature rhythm to light exposure as a function of time of day; and 3.) the characteristics of the metabolic heat production rhythm which is responsible for the daily cycle in body temperature. Results of these three completed experiments will be reported here. In addition, preliminary experiments were also performed in social entrainment of rhesus circadian rhythms and the properties of rhesus body temperature rhythms in constant conditions, where no external time cues were provided. Four adult male rhesus monkeys served as subjects in all experiments. All experiments were performed at the California Regional Primate Research Center. Each animal was implanted with a biotelemetry unit that measured deep body temperature. All surgeries were performed by a board certified veterinary surgeon under sterile conditions. The biotelemetry implants also provided an index of activity level in each animal. For metabolic heat production measurements, oxygen consumption and carbon dioxide production were measured and the caloric equivalent of these was calculated. Specific methodologies are described in detail.

Fuller, Charles↗

Syntheses and Degradations of Fluorinated Heterocyclics: Perfluoroalkyl and Perfluoroalkylether-1,3,4-Oxadiazoles - 3

2,5-Bis(perfluoro-n-heptyl)-, 2-perfluoroalkylether-5-perfluoro-n- heptyl- , and 2 , 5-bisperfluoroalkylether-1,3,4-oxadiazoles were synthesized and characterized. 2,5-Bis(perfluoro-n-heptyl)-1,3,4-oxadiazole was thermally and hydrolytically stable at 325 C; however, in the presence of air, degradation took place at 235 C. The perfluoroalkylether analogue exhibited thermal and hydrolytic stability at 325 C; it was found to be unaffected by jet-A fuel and air at 235 C. At 325 C in air some degradation occurred as evidenced by volatiles production, oxygen consumption, and 96% starting material recovery.

Paciorek, K. J. L.↗

Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures

The purpose of this study was to determine if intestinal temperature (Tin) might be in acceptable alternative to esophageal (Tes) and rectal temperature (Trec) to assess thermoregulation during supine exercise. We hypothesized that Tin would have values similar to Tes and a response time similar to Trec, but the rate of temperature change across time would not be different between measurement sites. Seven subjects completed a continuous supine protocol of 20 min of rest, 20 min of cycle exercise at 40% peak oxygen consumption (VO2pk), 20 min of cycle exercise at 65% V02pk, and 20 min of recovery. Tes, Trec, and Tin were recorded each min throughout the test. Temperatures were not different after 20 min of rest, but Trec was less than the Tes and Tin at the end of the 40% and 65% VO2pk stages. After 20 min of recovery, Tes was less than either Trec or Tin, which were not different from each other. Time to threshold for increased temperature from rest was greater for Trec than Tes but not different from Tin. Time to reach peak temperature was greater for Tin and Trec than Tes. Similarly, time to a decrease in temperature after exercise was greater for Trec than Tes, but not different from Tin. The rate of temperature change from threshold to the end of the 40% VO2pk stage was not different between measurement sites. However, the rate of change during recovery was more negative for Tes than Tin and Trec, which were different from each other. Measurement of Tin may he an acceptable alternative to Tes and Trec with an understanding of its limitations.

Lee, Stuart M. C.↗

A Pilot Study for Applying an Extravehicular Activity Exercise Prebreathe Protocol to the International Space Station

Decompression sickness (DCS) is a serious risk to astronauts performing extravehicular activity (EVA). To reduce this risk, the addition of ten minutes of moderate exercise (75% VO2pk) during prebreathe has been shown to decrease the total prebreathe time from 4 to 2 hours and to decrease the incidence of DCS. The overall purpose of this pilot study was to develop an exercise protocol using flight hardware and an in-flight physical fitness cycle test to perform prebreathe exercise before an EVA. Eleven subjects volunteered to participate in this study. The first objective of this study was to compare the steady-state heart rate (HR) and oxygen consumption (VO2) from a submaximal arm and leg exercise (ALE) session with those predicted from a maximal ALE test. The second objective was to compare the steady-state HR and V02 from a submaximal elastic tube and leg exercise (TLE) session with those predicted from the maximal ALE test. The third objective involved a comparison of the maximal ALE test with a maximal leg-only (LE) test to conform to the in- flight fitness assessment test. The 75% VO2pk target HR from the LE test was significantly less than the target HR from the ALE test. Prescribing exercise using data from the maximal ALE test resulted in the measured submaximal values being higher than predicted VO2 and HR. The results of this pilot study suggest that elastic tubing is valid during EVA prebreathe as a method of arm exercise with the flight leg ergometer and it is recommended that prebreathe countermeasure exercise protocol incorporate this method.

Woodruff, Kristin K.↗

Temperature Regulation in Crewmembers After a 115-Day Space Flight

Impaired thermoregulation, which has been observed during exercise following bed rest, may significantly impact crewmembers during space flight operations by decreasing exercise capacity and orthostatic tolerance. Impaired temperature regulation would cause higher levels of core temperature, due to an attenuated cutaneous vasodilatory reflex and sweating response, for a given oxygen consumption. Two mate crewmembers of the Mir 18 mission performed supine cycle exercise se (20 min @ 40% and 20 min @ 65% preflight VO2pk) 145 days preflight and 5 days postflight. Core temperature (Tcore) was measured by an ingestible telemetry pill, skin blood flow (SBF) by laser Doppler velocimetry, and sweat rate (SR) by dew point hygrometry. Tcore at the time of test termination was similar (37.8 C) for both subjects before and after flight despite a shorter test duration (40 vs 28-29 minutes) postflight. The slopes of the SBF/Tcore relationship (Subj 1: 396 vs 214; Subj 2: 704 vs 143 Perfusion Unit/degC) and SR/Tcore relationship (Subj 1: 4.5 vs 2.1; Subj 2: 11.0 vs 3.6mg/min/sq cm/degC) were reduced postflight. Tcore thresholds for both SR (Subj 1: 37.4 vs 37.6; Subj 2: 37.6 vs 37.6 C) and SBF (Subj 1: 37.3 vs 37.5; Subj 2: 37.6 vs 37.7 C) were similar pre- to postflight. For these 2 crewmembers, it appeared that thermoregulation during exercise was impaired as evidenced by compromised heat loss responses after long-duration space flight.

Lee, S. M. C.↗

Development and Application of Tools to Characterize the Oxidative Degradation of AP/HTPB/Al Propellants in a Propellant Reliability Study

The oxidative thermal aging of a crosslinked hydroxyl-terminated polybutadiene (HTPB)/isophorone diisocyanate (IPDI) polyurethane rubber was studied at temperatures between 25 C and 125 C. Changes in tensile elongation, mechanical hardening, polymer network properties, density, O2 permeation, and molecular chain dynamics were investigated as a function of age. The techniques used include solvent swelling, detailed modulus profiling, and NMR relaxation measurements. The Arrhenius methodology, which normally assumes a linear extrapolation of high temperature aging data, is critically evaluated by using extensive data superposition and highly sensitive oxygen consumption measurements. Significant curvature in the Arrhenius diagram of these oxidation rates is observed to be similar to previous results found for other rubber materials that have been evaluated by this technique. Preliminary gel/network properties suggest that crosslinking is the dominant process at higher temperatures. The effect on the oxidation rate of the binder when other constituents found in propellants are present, such as ammonium perchlorate, plasticizer and aluminum powder, is presented.

Celina, Mathew↗

Development of Countermeasures and Exercise Protocols to Reduce the Effects of Microgravity

I have helped scientists at NASA-JSC in analyzing data from many projects. Some of the major ones are: (1) cardiovascular responses to lower body negative pressure (LBNP) following bed rest, (2) the effects of dietary sodium, (3) in-flight cycle exercise mitigates reduced oxygen consumption at submaximal heart rates following space flight, (4) exercise thermoregulation after 13 days of head down bed rest, and (5) bed rest induced orthostatic intolerance. Many of the projects have now been completed and some of them are in the process of being published and others have been presented at national meetings. These projects have helped me be a true statistician and given me a real-life perspective of how interesting and complicated data can be. As a by-product of of these involvements I have been able to write and publish some methodological research that have applications in NASA and elsewhere. For instance, while I was at JSC, I happened to meet Dr. Al Feiveson and got into a discussion of the Space Shuttle Reliability. This led us to rethink about the way the data on the accelerated life testing of space shuttle pressure vessels had been analyzed. This has resulted in a major statistical paper and the paper has appeared in one of the top journals in the field of Statistics. A review of the paper by the editor of the journal was published in AmStatNews, a copy is attached with this report. I have presented these findings at the national/international statistics conference and at other places. I have also written another paper on reliability and a paper on calibration techniques that have applications in the engineering and the biomedical branches of NASA. Further, I am currently in the process of writing at least two more papers that have direct applications in NASA related studies.

Kulkarni, Pandurang M.↗

Resting Energy Expenditure of Rats Acclimated to Hyper-Gravity

To determine the influence of body mass and age on resting energy expenditure (EE) following acclimation to hyper-gravity, oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured to calculate resting energy expenditure (EE), in male rats, ages 40 to 400 days, acclimated to 1.23 or 4.1 G for a minimum of two weeks. Animals were maintained on a centrifuge to produce the hyper-gravity environment. Measurements were made over three hours in hyper-gravity during the period when the lights were on, the inactive period of rats. In rats matched for body mass (approximately 400 g) hyper-gravity increased VO2 by 18% and VCO2 by 27% compared to controls, resulting in an increase in RER, 0.80 to 0.87. There were increases in resting EE with an increase in gravity. This increase was greater when the mass of the rat was larger. Rating EE for 400g animals were increased from 47 +/- 1 kcal/kg/day at 1 G, to 57 +/- 1.5 and 5.8 +/- 2.2 kcal/kg/day at 2,3 and 4.1 G, respectively. There was no difference between the two hyper-gravity environments. When differences in age of the animals were accounted for, the increase in resting EE adjusted for body mass was increased by over 36% in older animals due to exposure to hyper-gravity. Acclimation to hyper-gravity increases the resting EE of rats, dependent upon body mass and age, and appears to alter substrate metabolism. Increasing the level of hyper-gravity, from 2.3 to 4.1 G, produced no further changes raising questions as to a dose effect of gravity level on resting metabolism.

Wade, Charles E.↗

An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity and Extraterrestrial Fire-Safety Applications

The objective of this project is to modify the standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. This apparatus will allow us to conduct normal gravity experiments that accurately and quantitatively evaluate a material's flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire configuration that provides a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by a flame in a spacecraft or extraterrestrial gravity level. Prototype unit testing results are presented in this paper. Ignition delay times and regression rates for PMMA are presented over a range of radiant heat flux levels and equivalent stretch rates which demonstrate the ability of ELSA to simulate key features of microgravity and extraterrestrial fire behavior.

Olson, S. L.↗