Search NASA⌕ Search

SEARCH · Search NASA

Results for “Off-Axis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Space telescope optical telescope assembly/scientific instruments. Phase B: Preliminary design and program definition study. Volume 2A. focal plane camera

Trade studies were conducted to ensure the overall feasibility of the focal plane camera in a radial module. The primary variable in the trade studies was the location of the pickoff mirror, on axis versus off-axis. Two alternatives were: (1) the standard (electromagnetic focus) SECO submodule, and (2) the MOD 15 permanent magnet focus SECO submodule. The technical areas of concern were the packaging affected parameters of thermal dissipation, focal plane obscuration, and image quality.

Source record↗

A comparison of simple shear characterization methods for composite laminates

Various methods for the shear stress-strain characterization of composite laminates are examined, and their advantages and limitations are briefly discussed. Experimental results and the necessary accompanying analysis are then presented and compared for three simple shear characterization procedures. These are the off-axis tensile test method, the + or - 45 degs tensile test method and the 0 deg/90 degs symmetric rail shear test method. It is shown that the first technique indicates that the shear properties of the G/E laminates investigated are fundamentally brittle in nature while the latter two methods tend to indicate that the G/E laminates are fundamentally ductile in nature. Finally, predictions of incrementally determined tensile stress-strain curves utilizing the various different shear behavior methods as input information are presented and discussed.

Yeow, Y. T.↗

Gregorian all-reflective optical system

An optical heterodyne receiver comprises a system of reflectors forming a folded Gregorian configuration for collecting a signal beam, and an optical detector located at the focus of the system. A paraboloidal primary reflector and an elipsoidal secondary reflector face each other on an optical axis with the focus of the secondary reflector coinciding with the focus of the primary reflector. An auxiliary laser generates a local oscillator beam that is combined with the signal beam after the signal beam emerges from the exit pupil (which is also the aperture stop) of the system, and the resultant is impinged on the detector. A pair of image motion compensators is located as close to the exit pupil as possible for aligning off-axis inputs to the detector.

King, W. L.↗

The Lyman alpha coronagraph

The rocket-borne Lyman alpha coronagraph (RLAC) is to be used in the absence of a natural solar eclipse to determine coronal temperatures from measurements of the line width of Lyman-alpha and to determine neutral hydrogen densities of coronal material from the absolute intensity. The coronagraph consists of a 75-cm Fastie-Ebert scanning spectrometer with an AMR 641 photoelectric detection system, an off-axis parabolic primary mirror, and an occulting system. A special optical arrangement achieves rejection of radiation from the solar disk.

Kohl, J. L.↗

An Integrated Theory for Predicting the Hydrothermomechanical Response of Advanced Composite Structural Components

An integrated theory is developed for predicting the hydrothermomechanical (HDTM) response of fiber composite components. The integrated theory is based on a combined theoretical and experimental investigation. In addition to predicting the HDTM response of components, the theory is structured to assess the combined hydrothermal effects on the mechanical properties of unidirectional composites loaded along the material axis and off-axis, and those of angleplied laminates. The theory developed predicts values which are in good agreement with measured data at the micromechanics, macromechanics, laminate analysis and structural analysis levels.

Chamis, C. C.↗

Evaluation of the Tensor Polynomial and Hoffman strength theories for composite materials

The Hoffman theory and the Tensor Polynomial (Tsai-Wu) theory with the stress interaction term set equal to zero have been found to be preferred alternatives to the general Tensor Polynomial theory for predicting strength of filamentary composite laminae. These theories were used to predict failure of off-axis boron/epoxy and E-glass/epoxy test specimens and gave excellent agreement with available experimental results. A numerical experiment was also performed to estimate the errors for ten different composite systems under six different loadings. The maximum error in predicted failure loads among all cases was below 10 percent. These results suggest that the Hoffman failure theory and the Tensor Polynomial theory with the stress interaction term equal to zero can predict failure of practical filamentary composite materials under general biaxial loading with sufficient accuracy for engineering applications.

Narayanaswami, R.↗

Parabolic Deformable Mirror Project Development and Device Characterization

Existing state-of-the-art wavefront sensing and control setups for the imaging of exoplanets utilize two high-actuator count flat deformable mirrors (DMs) to control both phase and amplitude aberrations. One of the objectives of the Exoplanet Spectroscopy (ExoSpec) project at Goddard Space Flight Center (GSFC) is to improve upon this regime through the development of parabolic deformable mirrors (PDMs), which can address several of the key limitations in existing setups. Specifically, the need for flat DMs to be located in conjugate pupil planes drives unique packaging challenges that can be overcome by allowing the off-axis imaging elements to be controllable as well. In addition, simulations show that the use of deformable powered elements will increase the overall controllable bandwidth, up to 35% over 5-12 lambda/D. To pursue this effort, the ExoSpec group has begun testing a first-generation parabolic DM, which is already informing a second generation design. This paper will provide a comprehensive update on its characterization, including influence function measurements, linearity analysis, closed-loop wavefront control performance, and thermal stability assessment.

spectroscopy↗

Latest Three-Flavor Neutrino Oscillation Results from NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. NOvA was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiments consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from a neutrino-beam exposure of $26.60 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.50\times 10^{20}$ POT with an additional low energy $\nu_e$ sample, will be presented in this talk.

Singh, Ishwar↗

Updates and Lessons Learned from NuMI Beamline at Fermilab

The Neutrinos at the Main Injector (NuMI) beamline at Fermilab generates an intense muon neutrino beam for the NOvA (NuMI Off-axis $\nu_e$ Appearance) long-baseline neutrino experiment. Over the years, the NuMI beamline has been pivotal in advancing neutrino physics, providing invaluable data and insights. This proceeding paper discusses updates and the lessons learned from recent experiences during the beam operations, maintenance, and monitoring of the NuMI beamline. Key topics include the optimization of beam performance and challenges in maintaining beamline stability. The paper aims to share best practices and provide a road-map for future beamline projects, including the Long-Baseline Neutrino Facility (LBNF).

43 PARTICLE ACCELERATORS↗

The NuMI Flux Prediction at ICARUS

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment seeking to probe fundamental symmetries within the structure of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix, and perform precision measurements its parameters including the neutrino mass ordering via the sign of $\Delta m^2_{31}$, and the charge-parity violating phase, $\delta_{CP}$. To make these measurements with high precision, DUNE will require external $\nu$-Ar scattering cross section data as a crucial input to the oscillation fit. Imaging Cosmic And Rare Underground Signals (ICARUS) is a 476 t liquid argon neutrino detector located at Fermi National Accelerator Laboratory (FNAL) where it is serving as the far detector for the Short-Baseline Neutrino (SBN) program along the Booster Neutrino Beam (BNB) axis. ICARUS additionally lies 795 m downstream and 100.1 mrad off-axis of the Neutrinos at the Main Injector (NuMI) neutrino beam. From this position, ICARUS is exposed to a large flux of NuMI (anti-)electron and (anti-)muon neutrinos, and poses a unique opportunity to provide high-statistics measurements of quasi-elastic and single pion-production cross sections for four neutrino flavors ($\nu_{\mu}$, $\nu_{e}$, $\bar{\nu}_{\mu}$, $\bar{\nu}_{e}$). This dissertation is centered around accurately characterizing the models and estimating their precision for use in making these measurements. This includes identifying major sources of uncertainty in the models such that they can be properly propagated to the cross section measurements. Specifically, this work focused on the model of the NuMI beamline and its impact on the neutrino fluxes, but also delved into the detector response model and its impact on reconstructed observables in the detector. Significant efforts were made to improve the characterization to enhance precision and thus reduce the level of propagated uncertainty. In particular, the NuMI flux was determined to be composed of 57% $\nu_{\mu}$, 38% $\bar{\nu}_{\mu}$, 3% $\nu_{e}$, and 2% $\bar{\nu}_{e}$ while the horns are operating in the positive-particle focusing configuration. The total uncertainty on the $\nu_{\mu} + \bar{\nu}_{\mu}$ ($\nu_{e} + \bar{\nu}_{e}$) flux while operating in the forward horn operating mode was determined to be 10.84% (9.04%). Compared to the on-axis flux, mesons that eventually decay to neutrinos more frequently reinteract within the NuMI structure, resulting in elevated uncertainty as these processes are not well-constrained by existing hadron interaction cross section measurements. Covariance matrices were calculated to propagate the flux uncertainty characterization to NuMI analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

Comparison of ACHILLES and GENIE Observables for DUNE-PRISM and the SBN Program, with New 2p2h Predictions

The DUNE near detector LAr-TPC can be moved to different off-axis positions to sample different neutrino fluxes, which in turn will yield different cross section distributions for observables. Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Additionally, the predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.

Dumont, Daniel [Fermilab]↗

Latest Results from the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment based at Fermilab, IL, USA, that observes $\nu_\mu(\bar{\nu}_\mu) \to \nu_\mu(\bar{\nu}_\mu)$ disappearance and $\nu_\mu(\bar{\nu}_\mu) \to \nu_e(\bar{\nu}_e)$ appearance oscillations from a beam of neutrninos provided by the NuMI beamline at Fermilab. The experiment is made up of two functionally identical liquid scintillation detectors, both situated 14.6 mrad off-axis to the beam direction and made out of PVC extrusion cells arranged in alternating horizontal and vertical planes. The experiment is sensitive not only to standard three-flavor neutrino oscillations, but also to beyond standard model (BSM) searches such as sterile neutrino and non-standard interaction (NSI) of neutrinos with matter searches. The latest results from 3-flavor neutrino oscillation analysis, the NOvA-T2K joint analysis, searches for sterile neutrinos and non-standard interactions of neutrinos with matter, will be discussed here.

Choudhary, Brajesh [Delhi Tech. U.] (ORCID:0000000↗

Neutrino-argon cross-section measurements from the MicroBooNE experiment

MicroBooNE is a liquid argon time projection chamber (LArTPC) neutrino detector located along the Fermilab Booster Neutrino Beam and 8 degrees off-axis to the Neutrinos at the Main Injector beam. MicroBooNE collected data from both beams accumulating a large neutrino-argon scattering dataset containing hundreds of thousands of events. Understanding neutrino-argon interactions is crucial for the next generation of neutrino oscillation experiments including DUNE. MicroBooNE has developed pioneering methodologies and novel reconstruction tools in order to benchmark models at very high sensitivity across the interaction phase space, including for ultra-rare channels. This proceeding presents an overview of the most recent MicroBooNE neutrino interaction results. These measurements span inclusive, CC0$π$, and rare channels including $Λ$, $K^+$ and $η$ production, providing invaluable datasets for constraining backgrounds and improving the modeling of neutrino scattering critical for the broader LArTPC neutrino physics program.

Liu, Liang [Fermilab] (ORCID:000000026753925X)↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector using a high purity beam of neutrinos and anti-neutrinos from Fermilab's NuMI beamline. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be discussed here.

Choudhary, Brajesh [Delhi U.] (ORCID:0000000150291↗

Neutrino beam bunch structure reconstruction with precision timing in the ICARUS liquid argon time projection chamber

The ICARUS detector has been operating smoothly since 2021 as the far detector in the Short Baseline Neutrino (SBN) program at Fermilab, collecting neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Neutrinos at the Main Injector (NuMI) beam. Analysis of neutrino interactions in ICARUS requires mitigation of substantial cosmogenic backgrounds. This is achieved by using an external Cosmic Ray Tagger (CRT) and a Photomultiplier Tube (PMT) system embedded in the liquid argon. The intrinsic neutrino beam bunch structure, inherited time structure from the Radio Frequency (RF) system used to accelerate the protons, can be resolved at the ICARUS detector using precise timing information. Located at shallow depth, ICARUS is exposed to a high flux of cosmic rays that can be mistaken for neutrino interactions. To mitigate this background, the CRT and a 3-meter-thick concrete overburden were installed. To better model backgrounds, ICARUS makes use of an overlay technique where simulated neutrino events are superimposed on detector beam-off data. PMTs installed within a Time Projection Chamber detect argon scintillation light emitted by high energy charged particles passing through the chamber and provide the event timing of neutrino interactions. The nanosecond-level beam bunch structure is reconstructed with the PMT system and can be used to further understand backgrounds and enhance neutrino physics capabilities. In this thesis, I will discuss background mitigation techniques using precision timing and present a novel technique to select neutrino events from our unbiased data stream using the beam bunch structure.

Heggestuen, Anna [Colorado State U.] (ORCID:000000↗

NOvA Sterile Neutrino Search with Additional Systematic Constraints

The NOvA experiment measures neutrino oscillations in a nearly pure muon neutrino beam. The neutral current (NC) and the muon neutrino charged current (CC) interaction disappearance are studied to search for active-to-sterile neutrino oscillations. NOvA consists of two functionally identical detectors placed 14 mrad off-axis of the Fermi National Accelerator Laboratory's NuMI beamline. The Near Detector (ND) is located 100 meters underground on-site at Fermilab, while the Far Detector (FD) is situated on the surface 810 kilometers away at Ash River, Minnesota. The NuMI beam is capable of operating in either forward or reverse horn current modes, producing predominantly neutrino or antineutrino beams, respectively. For this analysis, a simultaneous near and far detector joint fit approach was utilized. Systematic uncertainties constrain the ND while the statistical uncertainties constrain the FD. In addition to the dual baseline approach, the neutrino-on-electron elastic scattering sample was included. This interaction is advantageous as it is subject to minimal cross-section uncertainties, which will help reduce degeneracies between other uncertainty categories. This thesis presents the sterile neutrino oscillation sensitivity results using 27.2e+20 POT in FHC mode, 12.6e+20 in RHC mode, with the nu-on-e sample of 13.6e+20 POT in FHC.

Oh, Haejun [Cincinnati U.]↗

Investigating Interference Term in DUNE And SBND Neutrino Interactions with ACHILLES

Understanding neutrino-nucleus interactions is critical for conducting precise neutrino oscillation ex- periments. However, uncertainties in neutrino-nucleus cross section measurements and our incomplete understanding of nuclear effects remain a significant challenge in neutrino physics. In this paper, we investigate contributions from quantum interference between one-body and two-body interactions in charged-current quasi-elastic (CCQE) neutrino scattering amplitudes, using the ACHILLES event gen- erator. Simulations are performed using muon neutrino flux from Fermilab’s Booster Neutrino Beam (BNB), as well as Long-Baseline Neutrino Facility (LBNF) flux. We observe the neutrino flux interact- ing with Argon nuclei as detected by the Short Baseline Near Detector (SBND) and DUNE Near Detector (DUNE-ND), both Liquid Argon Time Projection Chambers (LArTPC). We focus on one muon and one proton final states with cascade interactions. We analyze multiple experimental observables including outgoing kinematic variables, energy-momentum transfer variables, and Transverse Kinematic Imbalance (TKI) variables. In this study, we also investigate the effects of PRISM (a method of sampling flux from multiple off-axis angles which creates different neutrino energy spectra). We find that the ratio of in- terference to quasi-elastic contributions gives a non-flat distribution across a 0-3.5 GeV energy range, indicating that effects of interference vary with the neutrino energy sampled. Our ultimate goal is to reduce systematic uncertainties from neutrino interactions when conducting oscillation experiments by working to disentangle the effects of quantum interference from the quasi-elastic signature.

Serumaga, Peera [Fermilab; UC, San Diego] (ORCID:0↗