Search NASA⌕ Search

SEARCH · Search NASA

Results for “Office Equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Inaugural Symposium of the Institute for Sustainable Energy and Environment, Virginia Commonwealth University

The Inaugural Symposium of the Institute for Sustainable Energy and Environment (ISEE) was held in Virginia Commonwealth University, Richmond, Virginia during April 26 – 28, 2023. The symposium addressed issues and challenges in energy and environment and highlighted the use of clean renewable energy to mitigate the adverse effects of fossil fuels and the greenhouse gases it produces. These issues are complex as the involve educating the public that the climate change is real, it is caused by the use of fossil fuels, it requires scientists and engineers to understand the fundamental science in the production and storage of renewable energy, it requires industries to manufacture and distribute the equipment necessary for commercial application of these technologies, it requires policy makers to put together policies and guidelines to make the transition from fossil fuels to renewable energies efficient, and it requires social scientists and educators to address environmental justice issues and create a workforce to sustain the transition. The symposium considered all the above issues with a diverse list of speakers from the federal and state government, industrial partners, and experts from science and technology to social sciences and public policy. Speakers from the White House Office of Science and Technology Policy, Department of Energy, universities, and non-governmental agencies discussed the challenges and solutions in Plenary as well as Panel sessions. The talks were recorded with permission from the speakers and the panelists and were put in the ISEE website. The participants included students, postdoctoral fellows, and professors from Virginia Commonwealth University and local area Historically Black College and Universities (HBCU) such as Virginia State University and Norfolk State University. The $5000 fund awarded by the Department of Energy were used to support the participation of students, postdoctoral fellows, and faculty from the HBCU institutions. The technical program the list of participants is provided later in the document.

08 HYDROGEN↗

Soil Temperature and Moisture, Council Road Mile Marker 71, Seward Peninsula, Alaska, beginning 2016

Daily averages of soil temperature and moisture measured once every hour at different heights, as well as daily averages of hourly measured snow depths located at Intensive Monitoring Stations at Council Road Mile Marker 71 site. Deployed at each site is an Onset HOBO U30 data logger with five smart temperature sensors and three smart soil moisture sensors (10HS). Three sites (CN_IS_4, CN_IS_6A, CN_IS_7) are equipped with a snow depth sensor. Data are retrieved annually since 2016. Contains 53 *.CSV files including a file inventory list by year. Data files have header rows, NaN fields indicate invalid or missing data, and negative vertical offsets are above ground. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Development for Under Tank Inspection of Double-Shell Tanks - 20045

The Department of Energy (DOE) Office of River Protection (DOE-ORP) is responsible for management and cleanup of the tank farms located at the Hanford Site. Nuclear waste at Hanford is stored in 149 single-shell tanks (SSTs) and 27 double-shell tanks (DSTs). The vast majority of the liquid radioactive waste is stored in the DSTs. The 27 DSTs, located in six tank farms, were constructed from 1967 to 1986 and, compared to the SSTs, provide greatly improved protection from leakage and better accessibility for inspection. The DSTs and ancillary equipment are expected to exceed their design life before their waste is removed and sent to the Waste Treatment and Immobilization Plant. The DST Integrity Project (DSTIP) must ensure that the DST system can meet the River Protection Project mission goals. This paper provides a programmatic overview of the DSTIP with a focus on development of under-tank inspection technologies. Currently, two categories of nondestructive examination (NDE) techniques for DSTs are implemented on the Hanford site: (1) surface (SNDE) and (2) volumetric (VNDE). Further discussion on current inspection techniques is provided in this paper. The technology development approach for advanced VNDE techniques will also be generally discussed as a precursor for another more detailed WM2020 paper and presentation by PNNL. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theoretical insights into the surface physics and chemistry of redox-active oxides

Redox active oxides are ubiquitous in materials applications, including catalysis, photovoltaics, self-cleaning glasses, chemical sensors, and electronic components. Their utility derives from their unique ability to access multiple metal charge states within a finite energy window. However, this property also confounds our ability to study reducible oxides, because it leads to structural, compositional, and electronic complexities that elude simplistic models of materials structure and function. Oxygen vacancies play a critical role in shaping the functional properties of such oxides; most notably, they lead to mobile charge imbalances that impact surface processes at significant distances from the originating defect. Atomistic simulations are inherently equipped to illuminate these phenomena at a fundamental level; however, reducible oxides pose great challenges due to the high level of electron correlation needed to correctly describe them. Knowing how defects form, couple, propagate, agglomerate, or repel each other and influence the surface properties of reducible oxides is only now coming into the grasp of modern theory and simulation capabilities. This knowledge is also key to discovering and controlling emergent materials processes at nanometer scale and beyond. The manuscript was written with support of all three authors from U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. Work by RR and VG was performed at Pacific Northwest National Laboratory (PNNL), which is a multi-program laboratory operated by Battelle for DOE under Contract DE AC05 76RL01830. AS was supported under Award DE-SC0007347.

Rousseau, Roger J.↗

The Role of Innovation in the Circularity of EV Lithium-Ion Batteries

This case study analysis highlights the role of innovations in EV battery design (cells, modules, and packs), reverse supply chain, and recycling processes in yielding value for the economics of recycling (and have the largest impact on the circularity of LIBs). Part of the assessment of value will be a semi-quantitative evaluation of the value of resilience in the rapidly evolving LIB market – i.e., there are a variety of risks that recyclers would face in making a financial commitment to a recycling facility including; the possibility that batteries would not be collected in sufficient quantities, the market for key constituents (e.g., cobalt) might decrease because of changes in battery chemistry, battery manufacturers may not be willing to pay as much for recycled material, etc. The analysis would be semi-quantitative in that two simple models would be used to assess 1. material flows using a previously developed excel-based reverse supply chain flows model, and 2. A LIB recycling process material and energy balance cost model that will be used to qualitatively assess the cost impacts of process innovations and changes in feed streams. Both sets of models are highly speculative in that they rely on a multitude of assumptions and input values (e.g., EV adoption rates) that vary widely in the literature. Additionally, the initial process flow diagrams and equipment lists for the recycling cost model are based on the Argonne EverBatt model, which is still under development. However, in combination with a critical review of the literature, economic modeling can yield valuable insights into the role of innovation in the circularity of LIBs and high-technology (“energy relevant”) products in general.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Advanced Mixed Waste Treatment Project Overcomes Challenges to Complete Treatment of Debris Waste - 20616

The Advanced Mixed Waste Treatment Project (AMWTP), operated by Fluor Idaho for the Department of Energy Idaho Operations Office, completed the last of its debris waste treatment in the fall of 2019. Concluding that work-scope was certainly not without its challenges. Fluor Idaho and its employees had to adapt to treating extremely challenging waste types, such as high-fissile gram materials and potentially pyrophoric and reactive wastes coming down the stretch. It also had to complete the sizing of large waste boxes from Mound Laboratories in inner-contamination enclosures designed to capture the extremely fine, 'flighty' plutonium-238 in its high-efficiency particulate air filters. Very few waste treatment facilities in the DOE Complex have completed their missions. In fact, most large-scale waste treatment facilities are still under construction with many months or years remaining before 'hot operations' begin. AMWTP is unique because it functioned as a 'one-stop shop.' Transuranic and low-level waste characterization, treatment, certification, and shipping all occurred there. AMWTP concluded the most challenging part of its mission and will continue to ship material out of the state of Idaho for the next decade. This paper will provide a background of the AMWTP mission, and the adaptations to its operating permit, equipment, or treatment processes to address challenging waste types. AMWTP will leave behind a legacy of being one of the most successful waste treatment facilities in the history of the DOE Complex. The facility was well-conceived, well-constructed, and well-executed; it was done right from start to finish. During the course of its waste treatment mission, the facility was required to adapt to changing conditions by treating extremely challenging waste types. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmark: Q1 2021 [Slides]

Our benchmarking method includes bottom-up accounting for all necessary system and projectdevelopment costs incurred when installing residential, commercial, and utility-scale systems, and it models the Q1 2021 costs for such systems, excluding any previous supply agreements or contracts. In general, we attempt to model the typical installation techniques and business operations from an installed-cost perspective, and our benchmarks are national averages. The residential PV-only benchmark and the commercial rooftop PV-only benchmark average costs by inverter type (string inverters, string inverters with direct current [DC] optimizers, and microinverters), weighted by inverter market share. The residential PV-only benchmark is further averaged across small installer and national integrator business models, weighted by market share. All benchmarks include variations—accounting for the differences in size, equipment, and operational use (particularly for storage)—that are currently available in the marketplace. All benchmarks assume nonunionized construction labor; residential and commercial PV systems predominantly use nonunionized labor, and the type of labor required for utility-scale PV systems depends heavily on the development process. All benchmarks assume the use of monofacial monocrystalline silicon PV modules. Benchmarks using cadmium telluride or bifacial modules could result in significantly different results. The data in this annual benchmark report inform the formulation of and track progress toward the U.S. Department of Energy (DOE) Solar Energy Technologies Office’s Government Performance and Reporting Act cost targets.

14 SOLAR ENERGY↗

Feasibility of critical infrastructure protection using network functions for programmable and decoupled ICS policy enforcement over WAN

Industrial control systems (ICS) represent a major component of our critical infrastructure. With the increasing need for more control and monitoring of such systems, ICS have seen an increase in connectivity to wide area networks (WAN) exposing aging equipment to rapidly evolving cybersecurity threats. Furthermore, the ICS data requires a reliability measure from the networks for critical functions for infrastructure monitoring and control. Especially when remote plant sites are involved such as pipelines, energy distribution networks, and transportation, WAN transport impairments most often provide a best effort delivery with no strict reliability guarantees. Network functions can provide a vendor agnostic, programmable critical infrastructure protection with a single maintenance, policy determination, and reliability assurance surface. A network function (NF) can be utilized for policy enforcement over the communication between remote entities and the main control office. This paper presents the research on transparent integration with existing ICS without disrupting communications, resulting in minimal downtime while decoupling the fast paced evolution of defensive security measures from the upgrade cycle of expensive long term hardware. We report our measurements on the resource requirements and overhead in the network for successful NF insertion under a wide variety of network impairments (network packet delay, reordering, and loss). Our paired NF implementation provides a policy enforcement platform extensible to cover myriad cybersecurity-related communication goals, including packet signing for verification, encryption for data privacy, packet filtering and data diode operation (i.e. protecting against eavesdropping, packet injection, and denial-of-service). Furthermore, bundling communication specifications into packet flows allows for tunability in applying policies as coarse- or fine-grained as the needs of the operator. We report on network function resource requirements in the form of required queue depth and network utilization overhead to inform the decision making against hardware cost constraints.

42 ENGINEERING↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Advanced Oxygen-Free Electrolyzer for Ultra-Low-Cost H 2 Storage for Fossil Plants (Final Technical Report)

DOE’s Office of Fossil Energy and Carbon Management has determined that long-duration energy storage solutions co-located with fossil energy assets offer significant benefits to the fossil industry, electric utilities, and customers. T2M Global has developed an Advanced O 2 -Free Electrolyzer System (AES) Technology for low-cost, long-duration H 2 energy storage for fossil plants. The MW-class AES Module conceptual design aims to upgrade stranded assets (dilute/waste syngas streams, excess electricity, and waste heat) at fossil plants to higher value H 2 for additional revenue and greater sustainability. The H 2 energy storage equips fossil plants with the load following capability needed for the lucrative grid-support services market created by Variable Renewable Energy resources.

08 HYDROGEN↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Expanding Collaborative Capacity to Address Climate Resiliency in the Great Lakes Region

U.S. Department of Energy (DOE), Office of Science, Award DE-SC0023215, Expanding Collaborative Capacity to Address Climate Resiliency in the Great Lakes Region, supported capacity and partnership building between researchers at Central Michigan University (CMU) and scientists at DOE laboratories. The work involved identifying potential collaborations both internal to CMU and between CMU researchers and DOE staff, developing collaborative research proposals, and partnering on pilot-scale research projects focused on enhancing resilience of Great Lakes communities, ecosystems, and infrastructure to global change and environmental stressors. DOE funds supported travel, time to develop collaborations, investigate new research pathways, and draft grant proposals, and a loan of DOE equipment to collect pilot data in support of future work. The project achieved its goal of strengthening research collaborations between interdisciplinary researchers at CMU and establishing new collaborations and partnerships between CMU and DOE scientists. These collaborations resulted in 5 pre-applications and 4 full applications for funding to DOE BER Funding Opportunities, a successfully funded DOE BER award (DE-SC0025260), a new pilot project that leveraged DOE resources (AquaBOT) to improve understanding of water quality conditions in Michigan rivers, and two presentations of preliminary results at national scientific conferences. This project’s outcomes will benefit the Great Lakes Region via new lines of collaborative research focused on improving the resilience of Michigan communities, ecosystems, and infrastructure.

58 GEOSCIENCES↗

Implementation and test of an automated control hunting fault correction algorithm in a fault detection and diagnostics tool

Control hunting due to improper proportional–integral–derivative (PID) parameters in the building automation system (BAS) is one of the most common faults identified in commercial buildings. It can cause suboptimal performance and early failure of heating, ventilation, and air conditioning (HVAC) equipment. Commercial fault detection and diagnostics (FDD) software represents one of the fastest growing market segments in smart building technologies in the United States. Implementation of PID retuning procedures as an auto-correction algorithm and integration into FDD software has the potential to mitigate control hunting across a heterogeneous portfolio of buildings with different BAS in a scalable way. This paper presents the development, implementation, and field testing of an automated control hunting fault correction algorithm based on lambda tuning open-loop rules. The algorithm was developed in a commercial FDD software and successfully tested among nine variable air volume boxes in an office building in the United States. The paper shows the feasibility of using FDD tools to automatically correct control hunting faults, discusses scalability considerations, and proposes a path forward for the HVAC industry and academia to further improve this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Software Bill of Materials in the Nuclear Industry

Nuclear power plants (NPP) have thousands of digital assets throughout their facility. Typically, NPPs have asset and configuration management programs that capture the make, model, and version of a component. This information, however, usually only includes first- or second-tier components and does not capture the complete enumeration of software components and their dependencies within operational technology (OT) equipment. As seen with recent cyberattacks, this level of detail is insufficient for identifying if and where an exploitable vulnerability exists within a facility. A software bill of materials (SBOM) provides this detailed enumeration. Further, integrating SBOMs with vulnerability data sources and vulnerability attestation reports can provide improved awareness leading to better cyber risk management and incident response. Preferably, SBOMs are provided by the supplier; however, when an NPP already owns a device, it is less likely they will have a supplier provided-SBOM. Fortunately, SBOMs can be generated on installed digital assets. This paper provides an introduction to the U.S. Department of Energy Office of Nuclear Energy paper titled “Towards Software Bill of Materials in the Nuclear Industry,” which describes the SBOM ecosystem and provides a suggested approach to methodically and seamlessly integrate an SBOM program in an NPP.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

EVI-X Updates and National Charging Assessment Report

With the support of DOE's Vehicle Technologies Office and the DOE/DOT Joint Office (JO), NREL has applied the EVI-X modeling suite to conduct a National Electric Vehicle Infrastructure Needs Assessment. This report considers a 2030 scenario in which 30-42 million light-duty electric vehicles are on the road (including plug-in hybrids). We consider the needs of vehicles used for typical daily driving, drivers without access to residential charging, corridor charging supporting long-distance travel, and ride-hailing electrification. We find that a national network of 28 million charging ports (including public and private infrastructure) will be necessary in our mid adoption scenario. This result is framed as a conservative estimate as the assumed costs include charging equipment and installation but exclude the cost of grid upgrades and distributed energy resources.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗