Sluiceway Operations to Pass Juvenile Salmonids at The Dalles Dam, Columbia River, USA

Existing ice and trash sluiceways are commonly used to pass juvenile salmonids downstream at hydropower dams through a benign, non-turbine route. At The Dalles Dam on the Columbia River, managers undertook optimizing operations of sluiceway weirs to maximize survival of juvenile salmonids at the powerhouse. We applied fixed-location hydroacoustic methods to compare fish passage rates and sluiceway efficiencies for two weir configurations during 2004 and 2005: three weirs versus six weirs, located at the mid- versus east powerhouse, respectively. We also analyzed horizontal distributions of passage at the sluiceway and turbines and the effects of operating turbines beneath open sluiceway gates to provide supporting data relevant to operations optimization. Based on the findings, we recommend the following for long-term operations for the sluiceway at The Dalles Dam: open six rather than three sluiceway weirs to take advantage of the maximum hydraulic capacity of the sluiceway; open the three weirs above the western-most operating main turbine unit (MU) and the three weirs at MU 8 where turbine passage rates are relatively high; operate the turbine units below open sluiceway weirs as a standard procedure; operate the sluiceway 24 h/d year-round to maximize its benefits to juvenile salmonids; and use the same operations for spring and summer emigrants. These operational concepts are transferable to dams where sluiceway surface flow outlets are used protect downstream migrating fishes.

juvenile salmonid passage↗

Tuning the heat transfer medium and operating conditions in magnetic refrigeration

A new experimental test bed has been designed, built, and tested to evaluate the effect of the system’s parameters on a reciprocating Active Magnetic Regenerator (AMR) near room temperature. Bulk gadolinium was used as the refrigerant, silicon oil as the heat transfer medium, and a magnetic field of 1.3 T was cycled. This study focuses on the methodology of single stage AMR operation conditions to get a high temperature span near room temperature. Herein, the main objective is not to report the absolute maximum attainable temperature span seen in an AMR system, but rather to find the system’s optimal operating conditions to reach that maximum span. The results of this research show that there is a optimal operating frequency, heat transfer fluid flow rate, flow duration, and displaced volume ratio in any AMR system. By optimizing these parameters in our AMR apparatus the temperature span between the hot and cold ends increased by 24%. The optimized values are system dependent and need to be determined and measured for any AMR system by following the procedures that are introduced in this research. It is expected that such optimization will permit the design of a more efficient magnetic refrigeration system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS USING THE GANNI CYCLE

The constant pressure ratio process, as implemented in the floating pressure - Ganni cycle, is a new variation to prior cryogenic refrigeration and liquefaction cycle designs that allows for optimal operation and design of helium refrigeration systems. This cycle is based upon the traditional equipment used for helium refrigeration system designs, i.e., constant volume displacement compression and critical flow expansion devices. It takes advantage of the fact that for a given load, the expander sets the compressor discharge pressure and the compressor sets its own suction pressure. This cycle not only provides an essentially constant system Carnot efficiency over a wide load range, but invalidates the traditional philosophy that the (‘TS’) design condition is the optimal operating condition for a given load using the as-built hardware. As such, the Floating Pressure- Ganni Cycle is a solution to reduce the energy consumption while increasing the reliability, flexibility and stability of these systems over a wide operating range and different operating modes and is applicable to most of the existing plants. This paper explains the basic theory behind this cycle operation and contrasts it to the traditional operational philosophies presently used.

42 ENGINEERING↗

Multi-layered Energy Management Framework for Extreme Fast Charging Stations Considering Demand Charges, Battery Degradation, and Forecast Uncertainties

To achieve a cost-effective and expeditious charging experience for extreme fast charging station (XFCS) owners and electric vehicle (EV) users, the optimal operation of XFCS is crucial. It is however challenging to simultaneously manage the profit from energy arbitrage, the cost of demand charges, and the degradation of a battery energy storage system (BESS) under uncertainties. This paper, therefore, proposes a multi-layered multi-time scale energy flow management framework for an XFCS by considering long- and short-term forecast uncertainties, monthly demand charges reduction, and BESS life degradation. In the proposed approach, an upper scheduling layer (USL) ensures the overall operation economy and yields optimal scheduling of the energy resources on a rolling horizon basis, thereby considering the long-term forecast errors. A lower dispatch layer (LDL) takes the short-term forecast errors into account during the real-time operation of the XFCS. Per the latest research, monthly demand charges can be as high as 90% of the total monthly bills for EV fast charging stations; to this end, this paper takes the first attempt at the reduction of demand charges cost by considering the trade-off between the energy cost and monthly demand charges. Contrasting literature, this work allocates an energy reserve in the BESS stored energy to deal with the impact of short-term forecast errors on the optimized real-time operation of the XFCS. Moreover, degradation modeling considers the trade-off between short-term benefits and long-term BESS life degradation. As a result, case studies and a comparative analysis prove the efficacy of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biomimetic model-based advanced control strategy integrated with multi-agent optimization for nonlinear chemical processes

Here, a novel framework is proposed for integrating biomimetic-based advanced control and multi-agent optimization approaches for nonlinear chemical process applications. In particular, a Biologically-Inspired Optimal Control Strategy, denoted as BIO-CS, is combined with multi-agent optimization (MAO) techniques to provide optimal solutions for dynamic systems. In this combined framework, the BIO-CS algorithm employs gradient-based optimal control solvers for the intermediate problems associated with the leader-follower agents’ local interactions. Also, the MAO uses the capabilities of heuristic-based optimization techniques by sharing process information to obtain optimal operating setpoints for the controller considering an overall process objective. The applicability of the proposed method is demonstrated using a nonlinear, multivariable, process model of a fermentation system. Specifically, the optimal operating points are computed by the MAO implementation for setpoint tracking, trajectory tracking and plant-model mismatch scenarios for BIO-CS application. Results of the developed framework are compared to a gradient-based Sequential Quadratic Programming (SQP) technique and a classical proportional-integral (PI) controller in terms of optimization and control studies, respectively. As an additional contribution, BIO-CS is also cast as a model predictive controller (MPC) for the first time and compared to the agent-based BIO-CS approach in terms of computational time and tracking error. Closed-loop control results show up to 46% improvement in tracking performance during transient for the multi-agent BIO-CS when compared to BIO-CS as MPC for additional computational expense. The obtained results illustrate the capabilities of this novel integrated framework including BIO-CS as MPC to achieve desired nonlinear system performance for various scenarios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CFD modeling of crystallization fouling with CO 2 desorption incorporated for a falling-film evaporator in thermal desalination

Seawater flowing around horizontal tubes in falling-film evaporators is a common configuration for thermal desalination. Heat is transferred from in-tube steam condensation to the shell-side seawater by conduction through the tube wall and scaling layer, and conduction and convection to the evaporating liquid film. CO 2 is simultaneously released from seawater and mixed with the produced vapor. Fouling coupled with CO 2 desorption has deleterious impacts on both evaporation and condensation. The evaluation of spatiotemporal dependent crystallization fouling and CO 2 desorption is vital to selecting optimal operating conditions. Here, in this work, a CO 2 desorption model is integrated into CFD modeling for predictions of coupled heat and mass transfer, to understand and predict scale formation and CO 2 desorption with local and transient profiles of temperature, carbonate species concentrations, pH, and total alkalinity. The porosity of the scale layer is experimentally determined as 67.7% and invoked in the calculation of effective thermal conductivity. The simulation results reveal that high steam temperatures increase seawater total alkalinity and accelerate scale formation. The scale thickness on the bottom tube reaches 0.30 μm and 5.24 μm for steam temperatures of 60 °C and 80 °C, respectively. High salinity leads to a large CO 2 desorption rates. The CO 2 desorption rate increases 43% when the seawater salinity increases from 35 to 55 g/kg. The effects of operating conditions on carbonate speciation and pH have been compared and analyzed. This model can serve as a comprehensive tool for the design of thermal desalination systems and optimal operation.

42 ENGINEERING↗

Modeling State Transition and Head-Dependent Efficiency Curve for Pumped Storage Hydro in Look-Ahead Dispatch

As one of the most widely installed utility-scale storage facilities, pumped storage hydro (PSH) plays an essential role in providing flexibility for power systems worldwide. Thus, to accurately quantify the flexibility of PSH units in operational optimization problems is important. The conventional PSH models in the literature rarely consider detailed state transitions due to their hourly-based settings. However, it becomes imperative for operational optimization on short-term intervals, especially with increasing shares of renewable energy in power systems. To this end, this paper presents a novel deterministic PSH model that considers the transition time and trajectory between three states of PSH units in look-ahead dispatch. Moreover, to better characterize the varying efficiency of PSH units with water head and flow rate, this paper proposes to model detailed headdependent efficiency curves (hereafter called input-output curves) in look-ahead dispatch, which encounters heavy computational burdens when short time intervals are applied. In this work, a zig-zag piece-wise linear approximation method is used for input-output curve modeling. This can enable an accurate quantification for variable efficiency and head dependence in a computationally effective manner. Here, numerical results are presented to show performances of the proposed PSH model in both flexibility quantification and computation time.

13 HYDRO ENERGY↗

Application of a machine learning algorithm (XGBoost) to offline RHIC luminosity optimization

The operation parameter optimization in 2020 RHIC low energy run is difficult. First, the RHIC luminosity is affected by many RHIC operation parameters, as well as affected by many Low Energy RHIC electron Cooling (LEReC) operation parameters. Second, the luminosity signal in this run is noisy and not sensitive to these parameter changes, especially when these parameters are very close to their optimized values. It is not easy to distinguish the effects of one parameter from all other operation parameters separately. Therefore, it is difficult to optimize the luminosity by varying these parameters one by one. To find a way for luminosity optimization, we analyze some operation parameters via a machine learning algorithm - XGBoost. After constructing a black-box surrogate model from XGBoost and plotting their partial dependency plots (PDF) and SHAP value plots for different operation parameters, we can find the effects of an individual parameter on the RHIC luminosity and optimize it accordingly.

43 PARTICLE ACCELERATORS↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

Optimization of Operating Profit for the FEED of the PZAS Process for CO 2 Capture on a 460 MW NGCC

A rating model of PZAS (Piperazine with the Advanced Stripper) for a 460 MW natural gas combined cycle was developed from vendor-provided equipment performance data. Surrogate rating models were built and used to optimize variable profit of the system subject to natural gas and electricity price at a fixed value for CO 2 of $\$80$/tonne. Several process constraints were considered between ambient temperatures of 4.4 and 40.5 °C. Lower lean loading resulted in lower reboiler heat duty of about 2.2 GJ/tonne. Lean loading at 0.2 mol/equiv N was sufficient at an ambient temperature of 4.4 °C to maximize variable profit. Solvent precipitation was avoided even at low lean loading (0.18 mol/mol) in the absence of a trim cooler for the lean solvent between the absorber and the cold cross exchanger. Optimal CO 2 removal was always higher than the design case removal of 90% and achieved a peak of 93.6% for 4.4 ºC ambient temperature. Lean solvent rate was a significant driver of profitability. The maximum capacity of the compressor was a significant constraint on profitability. Increasing compressor capacity by 20–30% could increase variable profit by about 21% in the case of 0.18 lean loading at 4.4 °C ambient temperature. Furthermore, this increase in profit was lower at higher ambient temperature and higher lean loading. The breakeven gas price was $\$4.6$/MMBtu at high lean loading of 0.22 mol/mol. Below this value, profit was maximized by increasing the boiler heat rate. Above this value, profit could not be increased by burning additional natural gas, requiring a reduction in boiler heat rate and consequently, specific heat duty. At lower lean loading (0.2, 0.18 mol/mol), this transition in heat duty was not observed due to the lower heat duty. As the ambient temperature increased, a similar trend in heat duty was observed at 0.22 lean loading, but the transition to lower heat duty occurred earlier at $\$4$/MMBtu. This was because of the lower CO 2 production at higher ambient temperature, making the process unprofitable at a gas price higher than $\$3$/MMBtu unless the heat duty of the stripper and natural gas boiler is steeply decreased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Grid Operation and Optimized PV Penetration Utilizing Highly Distributed Sensor Data

Sandia National Laboratories (SNL) and Enphase Energy, Inc. (Enphase) collaborated to address challenges related to the integration of Renewable Energy Systems. The goal of this research was to develop methods to cost-effectively achieve very high PV penetration scenarios (well beyond 100% of peak load at the feeder level) by leveraging distributed inverters to increase operator visibility and provide local voltage support This project focused on the integration of high penetration PV systems and other distributed resources such as energy storage, to determine how these technologies interoperate with each other and with utility distribution operations and management systems. To address the lack of coverage of feeder monitoring and communications infrastructure, SNL and Enphase leveraged highly distributed micro inverters that were installed in very large numbers in CA and Hawaii, and that have the ability to measure currant and voltage and communicate via a highly distributed network. The data was used to verify and enhance distribution system models and to optimize the control settings of distributed resources. SNL and Enphase demonstrated the effectiveness of these techniques by analyzing high PV penetration scenarios on distribution systems in California.

14 SOLAR ENERGY↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling

Efficiency in drilling is measured by Mechanical Specific Energy (MSE). MSE is the measure of the amount of energy input required to remove a unit volume of rock, expressed in units of energy input divided by volume removed. It can be expressed mathematically in terms of controllable parameters; Weight on Bit, Torque, Rate of Penetration, and RPM. It is well documented that minimizing MSE by optimizing controllable factors results in maximum Rate of Penetration. Current methods for computing MSE make it possible to minimize MSE in the field only through a trial-and-error process. This work makes it possible to compute the optimum drilling parameters that result in minimum MSE. The parameters that have been traditionally used to compute MSE are interdependent. Mathematical relationships between the parameters were established, and the conventional MSE equation was rewritten in terms of a single parameter, Weight on Bit, establishing a form that can be minimized mathematically. Once the optimum Weight on Bit was determined, the interdependent relationship that Weight on Bit has with Torque and Penetration per Revolution was used to determine optimum values for those parameters for a given drilling situation. The improved method was validated through laboratory experimentation and analysis of published data. Two rock types were subjected to four treatments each, and drilled in a controlled laboratory environment. The method was applied in each case, and the optimum parameters for minimum MSE were computed. The method demonstrated an accurate means to determine optimum drilling parameters of Weight on Bit, Torque, and Penetration per Revolution. A unique application of micro-cracking is also presented, which demonstrates that rock failure ahead of the bit is related to axial force more than to rotation speed.

42 ENGINEERING↗

Collaboration on Radiation Driven Chemistry and Accelerator Operations

The Notre Dame Radiation Laboratory (NDRL) will contribute subject matter expertise to increase the Fermilab Illinois Accelerator Research (IARC) team’s knowledge of radiation chemistry processes. NDRL will do this by offering guidance on what analytical equipment to use to measure the effects of electron beam treatment during and post treatment. NDRL will also offer guidance that will help further develop IARC applications. The application areas are not limited to, but may include chemistries in the energy generation, industrial and environmental sectors. Fermi National Accelerator Laboratory’s IARC team will contribute subject matter expertise on accelerator operations to help NDRL optimize operation of their Titan-Beta accelerator. The objective of NDRL is to optimize accelerator output, as well as the beam transport and focusing from the accelerator to several experimental beam ports. NDRL also wants to install and optimize a new subharmonic pre-buncher to be able to deliver sub-nanosecond timescale doses for the study of reaction kinetics decoupled from molecular diffusion.

43 PARTICLE ACCELERATORS↗

GOOML Big Kahuna Forecast Modeling and Genetic Optimization Files

This submission includes example files associated with the Geothermal Operational Optimization using Machine Learning (GOOML) Big Kahuna fictional power plant, which uses synthetic data to model a fictional power plant. A forecast was produced using the GOOML data model framework and fictional input data, and a genetic optimization is included which determines optimal flash plant parameters. The inputs and outputs associated with the forecast and genetic optimization are included. The input and output files consist of data, configuration files, and plots. A link to the Physics-Guided Neural Networks (phygnn) GitHub repository is also included, which augments a traditional neural network loss function with a generic loss term that can be used to guide the neural network to learn physical or theoretical constraints. phygnn is used by the GOOML framework to help integrate its machine learning models into the relevant physics and engineering applications. Note that the data included in this submission are intended to provide a demonstration of GOOML's capabilities. Additional files that have not been released to the public are needed for users to run these models and reproduce these results. Units can be found in the readme data resource.

15 GEOTHERMAL ENERGY↗

A data driven control strategy for optimal and flexible operation of absorption systems; Stratégie de régulation fondée sur les données pour un fonctionnement optimal et flexible des systèmes à absorption

A novel control strategy for vapor absorption systems with experimental validation is presented. Statistical methods are used to integrate a detailed thermodynamic model and system-specific characteristics into a model based control algorithm. This allows for continuously optimized operation as well as fast response to variations in operating conditions. Autonomous controller performance was tested experimentally for response to changes in heat sink and evaporator temperatures. Continuous turndown with fast response to capacity demand changes, in contrast to suboptimal on/off control, was demonstrated. The thermal compressor concept was employed to develop the variable speed thermal compressor module, with aspects specific to absorption heat pumps, also facilitating cross-applicability of vapor compression system control strategies. Our results of this study enable further development and optimization of absorption systems for a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗