Design and applications of optical interferometers in astronomy Final report
Interferometer application to optical instrument testing, double star separation measurements, and photoelectric techniques for stellar diameter measurements
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Interferometer application to optical instrument testing, double star separation measurements, and photoelectric techniques for stellar diameter measurements
Optical instruments designed for use with large telescopes need to be tested before being installed at their work site. This is especially true for space-based instruments. To perform these tests, an auxiliary optical system is required which simulates the telescope exit pupil. Two-mirror projection systems can be used for this purpose. In this paper the first-order geometric properties and third-order aberrations of the general two-mirror system used at finite conjugates are examined. Relations are given in terms of five design parameters: object distance, image distance, exit pupil size, and the two mirror magnifications. A particular application of these relations is presented for a system designed to simulate the HST, for ground testing of the next generation of scientific instruments to be installed in the observatory. We show that a sufficient number of degrees of freedom are available to meet requirements when both mirrors are conics.
The 12 month Phase A Conceptual Design Study of the Atmospheric, Magnetospheric and Plasmas in Space (AMPS) payload performed within the Program Development Directorate of the Marshall Space Flight Center is presented. The AMPS payload makes use of the Spacelab pressurized module and pallet, is launched by the space shuttle, and will have initial flight durations of 7 days. Scientific instruments including particle accelerators, high power transmitters, optical instruments, and chemical release devices are mounted externally on the Spacelab pallet and are controlled by the experimenters from within the pressurized module. The capability of real-time scientist interaction on-orbit with the experiment is a major characteristic of AMPS.
The advent of remote sensing, the develpmemt of new optical instrumentation, and the associated advances in hydrological optics have transformed oceanography; it is now feasible to describe ocean-scale biogeochemical dynamcis from satellite observations, verified and complemented by measurements from optical sensors on profilers, moorings, and drifters. Only near-surface observations are common to both remote sensing and in situ observation, so it is critical to understand processes in the upper euphotic zone. Unfortunately, the biological principles that must be used to interpret optical variability near the sea surface are weaker than we would like, because relatively few experiments and analyses have examined bio-optical relationships under high irradiance characteristic of the upper optical depth. Special consideration of this stratum is justified, because there is good evidence that bio-optical relationships are altered near the surface; (1) the fluorescence yield from chlorophyll declines, leading to bias in the estimation of pigment from fluorometry; (2) the modeled relationship between solar-stimulated fluorecence and photosynthesis seems to deviate significantly from that presented for the lower euphotic zone; and (3) carbon-specific and cellular attenuation cross sections of phytoplankton change substantially during exposures to bright light. Even the measurement of primary productivity is problematic near the sea surface, because vertical mixing is not simulated and artifactual inhibition of photosynthesis can result. These problems can be addressed by focusing more sampling effort, experimental simulation, and analytical consideration on the upper optical depth, and by shortening timescales for the measurement of marine photosynthesis. Special efforts to study near-surface processes are justified, because new bio-optical algorithms will require quantitaitve descriptions of the responses of phytoplankton to bright light.
The team's major emphasis during this reporting period has been focused on the completion of the operational versions of the Marine Optical Buoys (MOBY's). Other work areas consisted of designing and testing bio-optical instrumentation, evaluating several of the SeaWiFS bio-optical protocols, processing data collected during field experiments, and reprocessing several of the Marine Optical Characteristics Experiment (MOCE) 2 and 3 bio-optical data sets. The team conducted one trip to the operations site in Honolulu, Hawaii, making necessary preparations for future field experiments. Part of the team also traveled to Moss Landing Marine Laboratories, Salinas, CA, and to American Holographic Co. Fitchburg MA, to assist with the fabrication of the next generation Marine Optical Buoys. Technical memoranda are being written to address the remote sensing reflectance, and instrument self-shading protocols. During the Ocean Color 96 meeting discussions with the Spanish on acquiring research vessel support during the MODIS validation period were conducted. A proposal will be generated towards this purpose for an experiment to be conducted off the North African coast during the summer of 1999.
It has been suggested that spectroscopic analysis of the aqueous humor of the eye could be used to indirectly predict blood glucose levels in diabetics noninvasively. We have been investigating this potential using Raman spectroscopy in combination with partial least squares (PLS) analysis. We have determined that glucose at clinically relevant concentrations can be accurately predicted in human aqueous humor in vitro using a PLS model based on artificial aqueous humor. We have further determined that with proper instrument design, the light energy necessary to achieve clinically acceptable prediction of glucose does not damage the retinas of rabbits and can be delivered at powers below internationally acceptable safety limits. Herein we summarize our current results and address our strategies to improve instrument design. 2005 Society of Photo-Optical Instrumentation Engineers.
We conducted high-contrast polarimetry observations of T Tau in the H-band, using the High Contrast Instrument for the Subaru Next Generation Adaptive Optics instrument mounted on the Subaru Telescope, revealing structures as near as 0farcs1 from the stars T Tau N and T Tau S. The whole T Tau system is found to be surrounded by nebula-like envelopes, and several outflow-related structures are detected in these envelopes. We analyzed the detailed polarization patterns of the circumstellar structures near each component of this triple young star system and determined constraints on the circumstellar disks and outflow structures. We suggest that the nearly face-on circumstellar disk of T Tau N is no larger than 0".8, or 117 au, in the northwest, based on the existence of a hole in this direction, and no larger than 0".27, or 40 au, in the south. A new structure, "N5," extends to about 0."42, or 59 au, southwest of the star, and is believed to be part of the disk. We suggest that T Tau S is surrounded by a highly inclined circumbinary disk with a radius of about 0."3, or 44 au, with a position angle of about 30°, that is misaligned with the orbit of the T Tau S binary. After analyzing the positions and polarization vector patterns of the outflow-related structures, we suggest that T Tau S should trigger the well-known E–W outflow, and is also likely to be responsible for a southwest precessing outflow "coil" and a possible south outflow.
The review of optical instrumentation, forward modeling, and inverse problem solution for the polarimetric aerosol remote sensing from space is presented. The special emphasis is given to the description of current airborne and satellite imaging polarimeters and also to modern satellite aerosol retrieval algorithms based on the measurements of the Stokes vector of reflected solar light as detected on a satellite. Various underlying surface reflectance models are discussed and evaluated.
Transmissive scanning elements for coherent laser radar systems are typically optical wedges, or prisms, which deflect the lidar beam at a specified angle and are then rotated about the instrument optical axis to produce a scan pattern. The wedge is placed in the lidar optical system subsequent to a beam-expanding telescope, implying that it has the largest diameter of any element in the system. The combination of the wedge diameter and asymmetric profile result in the element having very large mass and, consequently, relatively large power consumption required for scanning. These two parameters, mass and power consumption, are among the instrument requirements which need to be minimized when designing a lidar for a space-borne platform. Reducing the scanner contributions in these areas will have a significant effect on the overall instrument specifications, Replacing the optical wedge with a diffraction grating on the surface of a thin substrate is a straight forward approach with potential to reduce the mass of the scanning element significantly. For example, the optical wedge that will be used for the SPAce Readiness Coherent Lidar Experiment (SPARCLE) is approximately 25 cm in diameter and is made from silicon with a wedge angle designed for 30 degree deflection of a beam operating at approx. 2 micrometer wavelength. The mass of this element could be reduced by a factor of four by instead using a fused silica substrate, 1 cm thick, with a grating fabricated on one of the surfaces. For a grating to deflect a beam with a 2 micrometer wavelength by 30 degrees, a period of approximately 4 micrometers is required. This is small enough that fabrication of appropriate high efficiency blazed or multi-phase level diffractive optical gratings is prohibitively difficult. Moreover, bulk or stratified volume holographic approaches appear impractical due to materials limitations at 2 micrometers and the need to maintain adequate wavefront quality. In order to avoid the difficulties encountered in these approaches, we have developed a new type of high-efficiency grating which we call a Stratified Volume Diffractive Optical Element (SVDOE). The features of the gratings in this approach can be easily fabricated using standard photolithography and etching techniques and the materials used in the grating can be chosen specifically for a given application, In this paper we will briefly discuss the SVDOE technique and will present an example design of a lidar scanner using this approach. We will also discuss performance predictions for the example design.
The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.
Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.
The Optical Transient Detector (OTD) is a space-based instrument specifically designed to detect and locate lightning discharges as it orbits the Earth. This instrument is a scientific payload on the MicroLab-1 satellite that was launched into a low-earth, 70 deg. inclination orbit in April 1995. Given the orbital trajectory of the satellite, most regions of the earth are observed by the OTD instrument more than 400 times during a one year period, and the average duration of each observation is 2 minutes. The OTD instrument optically detects lightning flashes that occur within its 1300x1300 sq km field-of-view during both day and night conditions. A statistical examination of OTD lightning data reveals that nearly 1.4 billion flashes occur annually over the entire earth. This annual flash count translates to an average of 44 +/- 5 lightning flashes (intracloud and cloud-to-ground combined) occurring around the globe every second, which is well below the traditional estimate of 100 flashes per second that was derived in 1925 from world thunder-day records. The range of uncertainty for the OTD global totals represents primarily the uncertainty (and variability) in the flash detection efficiency of the instrument. The OTD measurements have been used to construct lightning climatology maps that demonstrate the geographical and seasonal distribution of lightning activity for the globe. An analysis of this annual lightning distribution confirms that lightning occurs mainly over land areas, with an average land:ocean ratio of 10:1. A dominant Northern Hemisphere summer peak occurs in the annual cycle, and evidence is found for a tropically-driven semiannual cycle.
Future NASA deep space missions will fly advanced high resolution imaging instruments that will require high bandwidth links to return the huge data volumes generated by these instruments. Optical communications is a key technology for returning these large data volumes from deep space probes. Yet to cost effectively realize the high bandwidth potential of the optical link will require deployment of ground receivers in diverse locations to provide high link availability. A recent analysis of GOES weather satellite data showed that a network of ground stations located in Hawaii and the Southwest continental US can provide an average of 90% availability for the deep space optical link. JPL and AFRL are exploring the use of large telescopes in Hawaii, California, and Albuquerque to support the Mars Telesat laser communications demonstration. Designed to demonstrate multi-Mbps communications from Mars, the mission will investigate key operational strategies of future deep space optical communications network.
This paper presents the mechanical design and analysis work completed on the Lunar Orbiter Laser Altimeter (LOLA). LOLA is one of six instruments on the Lunar Reconnaissance Orbiter (LRO), scheduled to launch in 2008. LOLA's main objective is to produce a high-resolution global lunar topographic model to aid in safe landings and enhance surface mobility in future exploration missions. LOLA will also look for evidence of ice water in the permanently shadowed regions around the lunar poles. Beryllium was chosen as the primary material for the LOLA Optical Transmitter Assembly to take advantage of the material's low mass density for light weight optical instrument design and for CTE matching of the refractive optical components. In addition, the thermal conductivity and specific heat of beryllium minimizes thermal gradients and thermal excursions. Special consideration must be made for the planning and preparation to fabricate beryllium components, as well as the preparation and cleaning of the components for gold plating. Assembly challenges include handling, precision cleaning and integration and testing. Structural analysis considerations include following General Environmental Verification Specification (GEVS) guidelines for GSFC payloads. The GEVS random environment for LOLA has an acceptance level of 10.0 Grms, which was analyzed for higher frequency transients. The low frequency transients were analyzed using a Mass Acceleration Curve to obtain an equivalent static loading. In addition, Structural-Thermal-Optical analysis, commonly referred to as STOP analysis, was completed to predict optical performance under the instrument's operational thermal environment. This included stress and distortion analysis on the receiver telescope lens.
A study was performed of cooling methods for a space-borne, earth observing infrared optical instrument, AMTS. Major requirements on the thermal design are an optics temperature below 200 K, a detector array temperature below 75 K, orbital lifetime of 3 to 5 years, a near polar, sun synchronous orbit with altitude near 800 km. Power dissipation of the detectors is 38 mW, in the optics compartment 1.4 W. Large radiative coolers positioned so as to be shielded from sun, spacecraft and earth result in predicted optics temperature of 156 K and detector temperature of 63 K.
Large offshore structures used for the deployment of optical instruments can significantly perturb the intensity of the light field surrounding the optical measurement point, where different portions of the visible spectrum are subject to different shadowing effects. These effects degrade the quality of the acquired optical data and can reduce the accuracy of several derived quantities, such as those obtained by applying bio-optical algorithms directly to the shadow-perturbed data. As a result, optical remote sensing calibration and validation studies can be impaired if shadowing artifacts are not fully accounted for. In this work, the general in-water shadowing problem is examined for a particular case study. Backward Monte Carlo (MC) radiative transfer computations- performed in a vertically stratified, horizontally inhomogeneous, and realistic ocean-atmosphere system are shown to accurately simulate the shadow-induced relative percent errors affecting the radiance and irradiance data profiles acquired close to an oceanographic tower. Multiparameter optical data processing has provided adequate representation of experimental uncertainties allowing consistent comparison with simulations. The more detailed simulations at the subsurface depth appear to be essentially equivalent to those obtained assuming a simplified ocean-atmosphere system, except in highly stratified waters. MC computations performed in the simplified system can be assumed, therefore, to accurately simulate the optical measurements conducted under more complex sampling conditions (i.e., within waters presenting moderate stratification at most). A previously reported correction scheme, based on the simplified MC simulations, and developed for subsurface shadow-removal processing of in-water optical data taken close to the investigated oceanographic tower, is then validated adequately under most experimental conditions. It appears feasible to generalize the present tower-specific approach to solve other optical sensor shadowing problems pertaining to differently shaped deployment platforms, and also including surrounding structures and instrument casings.
Phase retrieval, the process of determining the exitpupil wavefront of an optical instrument from image-plane intensity measurements, is the baseline methodology for characterizing the wavefront for the suite of science instruments (SIs) in the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST). JWST is a large, infrared space telescope with a 6.5-meter diameter primary mirror. JWST is currently NASA's flagship mission and will be the premier space observatory of the next decade. ISIM contains four optical benches with nine unique instruments, including redundancies. ISIM was characterized at the Goddard Space Flight Center (GSFC) in Greenbelt, MD in a series of cryogenic vacuum tests using a telescope simulator. During these tests, phase-retrieval algorithms were used to characterize the instruments. The objective of this paper is to describe the Monte-Carlo simulations that were used to establish uncertainties (i.e., error bars) for the wavefronts of the various instruments in ISIM. Multiple retrieval algorithms were used in the analysis of ISIM phase-retrieval focus-sweep data, including an iterativetransform algorithm and a nonlinear optimization algorithm. These algorithms emphasize the recovery of numerous optical parameters, including low-order wavefront composition described by Zernike polynomial terms and high-order wavefront described by a point-by-point map, location of instrument best focus, focal ratio, exit-pupil amplitude, the morphology of any extended object, and optical jitter. The secondary objective of this paper is to report on the relative accuracies of these algorithms for the ISIM instrument tests, and a comparison of their computational complexity and their performance on central and graphical processing unit clusters. From a phase-retrieval perspective, the ISIM test campaign includes a variety of source illumination bandwidths, various image-plane sampling criteria above and below the Nyquist- Shannon critical sampling value, various extended object sizes, and several other impactful effects.
Systems considerations for the Shuttle Infrared Telescope Facility (SIRTF) are discussed, taking into account SIRTF telescope engineering and trade studies, implications of orbital inclination for SIRTF design and operations, the approaching of the natural background limit with the SIRTF, a long life feasibility study for SIRTF, and the impact of chopping on image quality in the SIRTF telescope. Cryogenic systems and coolers for space missions are considered, giving attention to the Infrared Astronomical Satellite (IRAS) hardware flight performance, the design of the superfluid helium dewar for the Cosmic Background Explorer (COBE), Infrared Telescope (IRT) system cryogenic performance, the solidification of a cryogen by pumping, the production of superfluid helium using a Joule-Thomson Expander, and open cycle He-3 cooling to 0.18 K for space operation. Other topics explored are related to cryogenic optical instruments, facilities, and components, and to supporting technology for cryogenic infrared telescopes in space.