Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effect of Auger recombination on transient optical properties in XUV and soft X-ray irradiated silicon nitride

Spatially encoded measurements of transient optical transmissivity became a standard tool for temporal diagnostics of free-electron-laser (FEL) pulses, as well as for the arrival time measurements in X-ray pump and optical probe experiments. The modern experimental techniques can measure changes in optical coefficients with a temporal resolution better than 10 fs. This, in an ideal case, would imply a similar resolution for the temporal pulse properties and the arrival time jitter between the FEL and optical laser pulses. However, carrier transport within the material and out of its surface, as well as carrier recombination may, in addition, significantly decrease the number of carriers. This would strongly affect the transient optical properties, making the diagnostic measurement inaccurate. Below we analyze in detail the effects of those processes on the optical properties of XUV and soft X-ray irradiated Si 3 N 4 , on sub-picosecond timescales. Si 3 N 4 is a wide-gap insulating material widely used for FEL pulse diagnostics. Theoretical predictions are compared with the published results of two experiments at FERMI and LCLS facilities, and with our own recent measurement. The comparison indicates that three body Auger recombination strongly affects the optical response of Si 3 N 4 after its collisional ionization stops. By deconvolving the contribution of Auger recombination, in future applications one could regain a high temporal resolution for the reconstruction of the FEL pulse properties measured with a Si 3 N 4 -based diagnostics tool.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cellular Oxygen and Nutrient Sensing in Microgravity Using Time-Resolved Fluorescence Microscopy

Oxygen and nutrient sensing is fundamental to the understanding of cell growth and metabolism. This requires identification of optical probes and suitable detection technology without complex calibration procedures. Under this project Microcosm developed an experimental technique that allows for simultaneous imaging of intra- and inter-cellular events. The technique consists of frequency-domain Fluorescence Lifetime Imaging Microscopy (FLIM), a set of identified oxygen and pH probes, and methods for fabrication of microsensors. Specifications for electronic and optical components of FLIM instrumentation are provided. Hardware and software were developed for data acquisition and analysis. Principles, procedures, and representative images are demonstrated. Suitable lifetime sensitive oxygen, pH, and glucose probes for intra- and extra-cellular measurements of analyte concentrations have been identified and tested. Lifetime sensing and imaging have been performed using PBS buffer, culture media, and yeast cells as a model systems. Spectral specifications, calibration curves, and probes availability are also provided in the report.

Szmacinski, Henryk↗

Diagnostics Adapted for Heat-Treating Furnace Environment

Diagnostics developed for the in situ monitoring of rocket combustion environments were adapted for use in heat-treating furnaces. Simultaneous, in situ monitoring of the carbon monoxide, carbon dioxide, methane, water, and hydrogen concentrations in the endothermic gas of a heat-treating furnace were demonstrated under a Space Act Agreement between the NASA Lewis Research Center, the Heat Treating Network, and Akron Steel Treating Company. This endothermic gas, or "endogas," is produced in a catalytic process, where natural gas is "cracked" in the presence of air. Variations in the composition of the natural gas supplied lead to variations in the composition of the endothermic gas. These variations could lead to an unacceptable quality of steel products that are hardened through the carborization process that uses this gas. Conventional methods of monitoring the endogas include measuring the dew point of the gas and the oxygen concentration. From these data, the carbon monoxide content of the gas can be calculated. This carbon monoxide concentration creates the carbon potential needed for carburization. Several weak links are present in this approach. The oxygen monitor deteriorates over time, and the measurement might be inaccurate by 50 percent. Also, the chemistry equations, which are based on several assumptions, such as secondary species concentrations, provide only an approximate estimate of the carbon monoxide concentration. To address these weaknesses, we investigated a new method based on ordinary Raman spectroscopy, in which the carbon monoxide concentration is measured directly and in situ. This method measures the laser light scattered from the molecules. Each species interacts with the light and scatters the light at a different frequency. Spectral monitoring of the scattered light intensity at each molecular frequency of interest provides the species concentrations. One advantage over the conventional method is that several species can be monitored simultaneously. A second advantage is that the measurement is direct; there is no need to make assumptions, to filter the gas, or to calibrate the instrument. An instrument was designed consisting of a laser and a detection system within an enclosure, connected to an optical probe by fibers. For determining carbon monoxide concentration, the probe is mounted on the endothermic gas line, close to the generator. Optical fibers with a length of 150 ft have been used to transmit laser light from the instrument to the probe. There, the light is focused into the gas, and the scattered light is collected and transmitted back to the instrument where it is analyzed with a photomultiplier and lock-in amplifier. Laboratory tests have shown that with the current system the concentration of carbon monoxide, water, nitrogen, oxygen, and hydrogen in the air can be monitored with an accuracy of 1 percent. The concentration of carbon dioxide in the air can be monitored with an accuracy of 0.5 percent, and the concentration of methane with an accuracy of 0.2 percent. This instrument was taken to the Akron Steel Treating Plant, where field tests are in progress to verify the system capabilities. Planned developments are improving the accuracy, monitoring multiple locations, and reducing instrument size and cost.

Source record↗

Optical Metrology for the Segmented Optics on the Constellation-X Spectroscopy X-Ray Telescope

We present the metrology requirements and metrology implementation necessary to prove out the reflector technology for the Constellation X(C-X) spectroscopy X-ray telescope (SXT). This segmented, 1.6m diameter highly nested Wolter-1 telescope presents many metrology and alignment challenges. In particular, these mirrors have a stringent imaging error budget as compared to their intrinsic stiffness; This is required for Constellation-X to have sufficient effective area with the weight requirement. This has implications for the metrology that can be used. A variety of contract and noncontact optical profiling and interferometric methods are combined to test the formed glass substrates before replication and the replicated reflector segments.The reflectors are tested both stand-alone and in-situ in an alignment tower.Some of these methods have not been used on prior X-ray telescopes and some are feasible only because of the segmented approach used on the SXT. Methods discussed include high precision coordinate measurement machines using very low force or optical probe axial interferometric profiling azimuthal circularity profiling and use of advanced null optics such as conical computer generated hologram (CGHs).

Content, David↗

Comparison of two droplet sizing systems in an icing wind tunnel

A comparison between the Phase Doppler Analyzer and the combined measurements from the Particle Measuring Systems Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the icing cloud. Clouds with a range of volume median diameters from 10 to greater than 50 microns were used for the instrument comparisons. A comparison of the volume median diameter from the Phase Doppler Particle Analyzer and only the Forward Scattering Spectrometer Probe indicated agreement up to 18 microns. A combined volume median diameter was calculated from the droplet distribution of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement up to 30 microns with the agreement deteriorating rapidly above 30 microns. Droplet distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented.

Oldenburg, J. R.↗

Comparison of two droplet sizing systems in an icing wind tunnel

A comparison between the Phase Doppler Analyzer and the combined measurements from the Particle Measuring Systems Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the icing cloud. Clouds with a range of volume median diameterss from 10 to greater than 50 microns were used for the instrument comparisons. A comparison of the volume median diameter from the Phase Doppler Particle Analyzer and only the Forward Scattering Spectrometer Probe indicated agreement up to 18 microns. A combined volume median diameter was calculated from the droplet distribution of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement up to 30 microns with the agreement deteriorating rapidly above 30 microns. Droplet distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented.

Oldenburg, John R.↗

Exchange-Driven Intermixing of Bulk and Topological Surface States by Chiral Excitons in Bi 2 Se 3

Topological surface states (TSS) in the prototypical topological insulator (TI) Bi 2 Se 3 are frequently characterized using optical probes, but electron-hole interactions and their effect on surface localization and optical response of the TSS remain unexplored. Here, we use ab initio calculations to understand excitonic effects in the bulk and surface of Bi 2 Se 3 . We identify multiple series of chiral excitons that exhibit both bulk and TSS character, due to exchange-driven mixing. Further, our results address fundamental questions about the degree to which electron-hole interactions can relax the topological protection of surface states and dipole selection rules for circularly polarized light in TIs by elucidating the complex intermixture of bulk and surface states excited in optical measurements and their coupling to light.

42 ENGINEERING↗

Comparison of drop size distributions from two droplet sizing systems

A comparison between the Phase Doppler Particle Analyzer and the combined measurements from Particle Measuring Systems' Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the supercooled water droplet cloud. Clouds having a range of volume median diameters from 10 to greater than 50 microns were used for the instrument comparisons. A volume median diameter was calculated from combining the droplet distributions of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement from 10 microns up to 30 microns. Typical drop size distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented for several median volume diameters. A comparison of the distributions illustrates regions of the distributions where there is good agreement and other regions where there are discrepancies between the Phase Doppler Particle Analyzer and the Particle Measuring Systems' droplet size instruments.

Oldenburg, John R.↗

Ultrafast quasiparticle dynamics in the correlated semimetal Ca 3 Ru 2 O 7

The correlated polar semimetal Ca 3 Ru 2 O 7 exhibits a rich phase diagram including two magnetic transitions (T N = 56 K and T C = 48 K) with the appearance of an insulating-like pseudogap (at T C ). In addition, there is a crossover back to metallic behavior at T* = 30 K, the origin of which is still under debate. We utilized ultrafast optical-pump optical-probe spectroscopy to investigate quasiparticle dynamics as a function of temperature in this enigmatic quantum material. We identify two dynamical processes, both of which are influenced by the onset of the pseudogap. This includes electron-phonon relaxation and, below T C , the onset of a phonon bottleneck hindering the relaxation of quasiparticles across the pseudogap. We introduce a gap-modified two-temperature model to describe the temperature dependence of electron-phonon thermalization, and use the Rothwarf-Taylor to model the phonon bottleneck. In conjunction with density functional theory, our experimental results synergistically reveal the origin of the T-dependent pseudogap. Further, our data and analysis indicate that T* emerges as a natural consequence of T-dependent gapping out of carriers, and does not correspond to a separate electronic transition. Furthermore, our results highlight the value of low-fluence ultrafast optics as a sensitive probe of low-energy electronic structure, thermodynamic parameters, and transport properties of Ruddlesden-Popper ruthenates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generation of coherent phonons by coherent extreme ultraviolet radiation in a transient grating experiment

In this work, we investigate the excitation of coherent acoustic and optical phonons by ultrashort extreme ultraviolet (EUV) pulses produced by a free electron laser. Two crossed femtosecond EUV (wavelength 12.7 nm) pulses are used to excite coherent phonons at a wavelength of 280 nm, which are detected via diffraction of an optical probe beam. Longitudinal and surface acoustic waves are measured in BK-7 glass, diamond, and Bi 4 Ge 3 O 12 ; in the latter material, the excitation of a coherent optical phonon mode is also observed. We discuss probing different acoustic modes in reflection and transmission geometries and frequency mixing of surface and bulk acoustic waves in the signal. The use of extreme ultraviolet radiation will allow the creation of tunable GHz to THz acoustic sources in any material without the need to fabricate transducer structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Organic Cation Influence on Organic–Inorganic Thermal Equilibration within 2D Metal Halide Perovskites

Two-dimensional inorganic–organic lead halide perovskites exhibit tunable optoelectronic properties that are dictated by alternating layers of metal halide octahedra and organic cations. In such hybrid materials, vibrational coupling and thermalization between the low mass, insulating, organic cation spacers, and high mass inorganic octahedra remains poorly understood. Here, in this study, using femtosecond infrared-pump electronic-probe (IPEP) spectroscopy, we investigate the role of organic cation identity regarding the kinetics of vibrational energy exchange and sublattice mechanical coupling. Linear aliphatic cation-containing 2D perovskites with 4, 6, or 8 carbons (butylammonium = BA, hexylammonium = HA, and octylammonium = OA) were produced as thin films and mid-infrared pump pulses and then selectively excited organic cation stretch vibrations. Thermal energy introduction was evaluated via visible-wavelength optical probing that conveys inorganic octahedra response, owing to changes in electronic absorption. Multiple distinct spectral shifts appear upon excitation of the organic cations. Following an initial optical Stark shift caused by pump–probe temporal overlap, a redshift occurs within the first 10 ps that we attribute to compression of the octahedra by the expanded organic layers. Subsequently, a blueshift of the bandgap occurs commensurate with equilibration of both sublattices at an elevated temperature with a time constant of 21.8 to 31.6 ps depending on the spacer identity, with thermal energy transfer slowing by nearly 50% for the longest linker. By examining the effect that altered cation identity has on vibrational energy exchange, this work begins to offer routes to tune nonequilibrium response as well as provides insight into the fundamental impacts of organic spacers on thermal energy exchange in perovskite materials.

Peifer, Shoshanna E. [Northwestern Univ., Evanston↗

Optical measurements of winds and kinetic temperatures in the upper atmosphere

A development history is presented for the optical probing of the structure of the upper atmosphere, noting the contributions made by both ground and spaceborne optical sensors, and the role of advancements in thermospheric theory. The significance of optical techniques to current understanding of the upper atmosphere is discussed in the context of the new COSPAR International Reference Atmosphere-1986. While much of the work performed to date has involved the analysis of data obtained by individual observatories, the ability to effectively constrain theoretical models with such single-station data has become more limited with increasing model sophistication.

Hernandez, G.↗

Optical Diagnostics for Thermal Barrier Coatings

The translucent nature of ceramic oxide thermal barrier coatings (TBCs) provides an opportunity to employ optical probes to monitor temperature gradients and buried damage propagation within the coating. An important advantage of noncontact optical diagnostics is that they are amendable to health monitoring of TBCs in service. In this paper, two optical diagnostic approaches, operating in different wavelength regimes, are discussed. The first approach is the use of mid-infrared reflectance (MIR) to monitor the progression of TBC delamination produced by thermal cycling. This approach takes advantage of the maximum transparency of the TBCs at mid-infrared wavelengths, in particular, between 3 and 5 microns. Recent progress in extending the MIR method to a more practical visual inspection tool will be presented. A second approach, using visible wavelengths, is the embedding of thermographic phosphors within the TBC to add sensing functions to the coating that can provide depth-selective information about temperature gradients and TBC integrity. Emphasis will be given to the use of fluorescence decay time measurements to provide temperature readings from a thermographic phosphor layer residing beneath the TBC.

Eldridge, J. I.↗

A Compact Fiber Optic Eye Diagnostic System

A new fiber optic probe developed for determining transport properties of sub-micron particles in fluid experiments in a microgravity environment has been applied to study different parts of an eye. The probe positioned in front of an eye, delivers a low power (approximately few microW) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like materials in the vitreous humor. In a clinical setting, the probe can be mounted on a standard slit-lamp apparatus simply using a Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

A Compact Fiber Optic Eye Diagnostics System

A new fiber optic probe development for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to study different parts of the eye. The probe positioned in front of an eye, delivers a low power (approximately a few mu W) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. For a clinical use, the probe is mounted on a standard slit-lamp apparatus simply using Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

Raman-based sorting of microbial cells to link functions to their genes

In our recent work, we developed an optofluidic platform that allows a direct link to be made between the phenotypes (functions) and the genotypes (genes) of microbial cells within natural communities. By combining stable isotope probing, optical tweezers, Raman microspectroscopy, and microfluidics, the platform performs automated Raman-based sorting of taxa from within a complex community in terms of their functional properties. In comparison with manual sorting approaches, our method provides high throughput (up to 500 cells per hour) and very high sorting accuracy (98.3 ± 1.7%), and significantly reduces the human labour required. The system provides an efficient manner to untangle the contributions of individual members within environmental and host-associated microbiomes. In this News and Thoughts, we provide an overview of our platform, describe potential applications, suggest ways in which the system could be improved, and discuss future directions in which Raman-based analysis of microbial populations might be developed.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscale Imaging of Optical-Frequency Plasmonic Energy Transfer in Individual Nanoparticles and their Assemblies

The nonradiative transfer of energy from plasmonic metal nanostructures to their neighboring environments is a rapidly expanding research area because of its tremendous potential impact on photovoltaics and photocatalysis. Despite the significant progress achieved via optical spectroscopies, understanding the differing and competing energy transfer pathways available to these systems still presents a major challenge due to a lack of insight into their nanoscale optical responses. With the atom-scale spatial resolving power of the electron microscope and its ability to probe optical transitions, electron spectroscopies like EELS are uniquely suited for these challenges. Our proposal addressed STEM/EELS techniques (Camden) to directly measure and even control energy transfer pathways in hybrid plasmon-resonator systems and leveraged detailed theoretical models combined with simulation (Masiello) to understand the essential underlying physics. In particular, the outcome of our proposed studies deepened the fundamental understanding of how surface plasmons shed energy to their environment and the practical knowledge gained here will influence the design of future high-efficiency solar energy-harvesting devices and photocatalysts capable of operating throughout the visible and the infrared.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A fiber optic sensor for ophthalmic refractive diagnostics

This paper demonstrates the application of a lensless fiber optic spectrometer (sensor) to study the onset of cataracts. This new miniaturized and rugged fiber optic probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for cold-induced cataract in excised bovine eye lenses, and aging effects in excised human eye lenses. The device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics.

Ansari, Rafat R.↗