Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Liposomal Encapsulation Enhances In Vivo Near Infrared Imaging of Exposed Phosphatidylserine in a Mouse Glioma Model

We have previously demonstrated that exposed phosphatidylserine (PS) on tumor vascular endothelial cells is highly tumor specific, and development of the PS targeted near infrared (NIR) optical probe enables successful in vivo optical imaging of U87 gliomas in a mouse model. Liposomes have been widely used as a nanovector for delivery of chemotherapeutics and imaging contrast agents due to their high payload and longer circulation time. In the current study, we have fabricated PS-targeted liposomal nanoprobes encapsulating a NIR dye, IRDye® 800CW, aiming to enhance PS-targeted tumor imaging. Hydrophilic 800CW dye was packed into the core of polyethylene glycol (PEG)-coated liposomes functionalized with F(ab’)2 fragments of PGN635, a fully human monoclonal antibody that binds PS. As expected, in vivo dynamic NIR imaging revealed significantly improved tumor/normal contrast (TNR = 20 ± 3; p < 0.01) of subcutaneous U87 gliomas in mice after injection of the liposomal nanoprobes. Markedly enhanced TNR was observed after the tumors were irradiated to increase PS exposure (TNR = 48 ± 6; p < 0.05). Intriguingly, the liposomal nanoprobes, PGN-L-800CW showed distinct biodistribution and pharmacokinetics compared to the 800CW-PGN probes used in our previous study. Our data further suggest the usefulness of PS-targeted imaging probes for sensitive tumor detection and the potential of utilizing liposomal platform for glioma theranostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography

In order to exploit the femtosecond pulse duration of X-ray Free-Electron Lasers (XFEL) operating in the hard X-ray regime for ultrafast time-resolved protein crystallography experiments, critical parameters that determine the crystallographic signal-to-noise (I/σI) must be addressed. For single-crystal studies under low absorbed dose conditions, it has been shown that the intrinsic pulse intensity stability as well as mode structure and jitter of this structure, significantly affect the crystallographic signal-to-noise. Here, geometrical parameters are theoretically explored for a three-beam scheme: X-ray probe, optical pump, X-ray probe (or “probe-pump-probe”) which will allow experimental determination of the photo-induced structure factor amplitude differences, ΔF, in a ratiometric manner, thereby internally referencing the intensity noise of the XFEL source. In addition to a non-collinear split-beam geometry which separates un-pumped and pumped diffraction patterns on an area detector, applying an additional convergence angle to both beams by focusing leads to integration over mosaic blocks in the case of well-ordered stationary protein crystals. Ray-tracing X-ray diffraction simulations are performed for an example using photoactive yellow protein crystals in order to explore the geometrical design parameters which would be needed. The specifications for an X-ray split and delay instrument that implements both an offset angle and focused beams are discussed, for implementation of a probe-pump-probe scheme at the European XFEL. We discuss possible extension of single crystal studies to serial femtosecond crystallography, particularly in view of the expected X-ray damage and ablation due to the first probe pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-particle correlation functions in cluster perturbation theory: Hubbard spin susceptibilities

Cluster perturbation theory (CPT) is a computationally economic method commonly used to estimate the momentum- and energy-resolved single-particle Green's function. It has been used extensively in direct comparisons with experiments that effectively measure the single-particle Green's function, e.g., angle-resolved photoemission spectroscopy. However, many experimental observables are given by two-particle correlation functions. CPT can be extended to compute two-particle correlation functions by approximately solving the Bethe-Salpeter equation. We implement this method and focus on the transverse spin susceptibility, measurable via inelastic neutron scattering or with optical probes of atomic gases in optical lattices. Finally, we benchmark the method with the one-dimensional Fermi-Hubbard model by comparing with known results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Folded optical system for narrow forward looking probe

An optical system is described in which a laser beam makes three passes through a single graded index lens, forming a focus along the optic axis. It has important applications in endoscopic probes, where the forward looking characteristic permits the avoidance of obstacles and the narrow structure makes it minimally invasive.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical encoder devices and systems

Devices, systems and methods for encoding information using optical components are described. Information associated with a first optical signal (e.g., an optical pump) is encoded onto the phase of a second optical signal (e.g., an optical probe) using cross phase modulation (XPM) in a non-linear optical medium. The optical signals are multiplexed together into the nonlinear optical medium. The probe experiences a modified index of refraction as it propagates through the medium and thus accumulates a phase change proportional to the intensity of the pump. The disclosed devices can be incorporated into larger components and systems for various applications such as scientific diagnostics, radar, remote sensing, wireless communications, and quantum computing that can benefit from encoding and generation of low noise, high resolution signals. Examples of the encoded information includes intrinsic noise from the optical source, or others signals of interest, such as electrical, optical, X-ray, or high-energy particle signals.

Buckley, Brandon Walter↗

Optical encoder devices and systems

Devices, systems and methods for encoding information using optical components are described. Information associated with a first optical signal (e.g., an optical pump) is encoded onto the phase of a second optical signal (e.g., an optical probe) using cross phase modulation (XPM) in a non-linear optical medium. The optical signals are multiplexed together into the nonlinear optical medium. The probe experiences a modified index of refraction as it propagates through the medium and thus accumulates a phase change proportional to the intensity of the pump. The disclosed devices can be incorporated into larger components and systems for various applications such as scientific diagnostics, radar, remote sensing, wireless communications, and quantum computing that can benefit from encoding and generation of low noise, high resolution signals. Examples of the encoded information includes intrinsic noise from the optical source, or others signals of interest, such as electrical, optical, X-ray, or high-energy particle signals.

Buckley, Brandon Walter↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

Wigner polarons probe the dynamics of a Wigner crystal in a monolayer semiconductor

Wigner crystals—lattices made purely of electrons—provide a platform for studying correlation-driven quantum phase transitions. Despite extensive research, accessing the internal dynamics of Wigner crystals has remained challenging, with most experiments probing only static order or collective motion. Here we demonstrate optical probing and the manipulation of zero-field Wigner crystals and elucidate their static and dynamic properties in the frequency domain. We observe optical resonances that we identify as Wigner polarons—quasiparticles formed when the electron lattice is locally distorted by exciton–Wigner crystal coupling. We further achieve all-optical control of spins in the Wigner crystal, thereby directly probing valley-dependent Wigner polaron scattering well above the magnetic ordering temperature and in the absence of any external magnetic field. Lastly, we show optical melting of the Wigner crystal and observe different responses of the umklapp (static) and Wigner polaron (dynamic) resonances to optical excitation. Our results provide an avenue for understanding electron dynamics and achieving ultrafast optical control of interaction-driven quantum phase transitions in strongly correlated electron systems.

2D materials↗

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION↗

Measurement of an Explosively Driven Hemispherical Shell Using 96 Points of Optical Velocimetry

We report the measurement of the surface motion of a hemispherical copper shell driven by high explosives. This measurement was made using three 32-channel multiplexed photonic Doppler velocimetry (PDV) systems, in combination with a novel compound optical probe. Clearly visible are detailed features of the motion of the shell over time, enhanced by spatial correlation. Significant non-normal motion is apparent, and challenges in measuring such a geometry are discussed.

multiplexed PDV, frequency-time measurements, Quic↗

Measurement of Temperature and Density Profiles of the Plasma at PR-2 Facility

A new system of probe diagnostics at linear plasma simulator PR-2 is described, allowing us to measure the profiles of plasma temperature and density in different cross sections of the plasma column. The Langmuir probe fixed to the movable part of the two-coordinate positioning system built into the PR-2 passes the region of the discharge area during the process of measuring plasma parameters. The overall dimensions of the positioning system make it possible to mount electrical probes (magnetic probes, optical fibers, and other diagnostic equipment) covering almost the entire volume of the vacuum chamber between the magnetic mirrors of the device. We present the measurement results of local plasma parameters of the beam-plasma discharge (BPD) for different values of the input power and working gas pressure. The boundaries of appearance of discharge of three types were determined: the diffusive BPD mode, the BPD mode, and the arc mode. Dependences of the plasma concentration and temperature on the input power for different values of pressure have been also determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

Detecting and Tracking Nonfluorescent Nanoparticles Probes in Live Cells

Precisely imaging and tracking dynamic biological processes in live cells are crucial for both fundamental research in life sciences and biomedical applications. Nonfluorescent nanoparticles are emerging as important optical probes in live-cell imaging because of their excellent photostability, large optical cross sections, and low cytotoxicity. Here, we provide a review of recent development in optical imaging of nonfluorescent nanoparticle probes and their applications in dynamic tracking and biosensing in live cells. A brief discussion on cytotoxicity of nanoparticle probes is also provided.

36 MATERIALS SCIENCE↗

Coupled analysis of high and low frequency resonant ultrasound spectroscopy: Application to the detection of defects in ceramic balls

A coupled analysis of high and low frequency resonant ultrasound spectroscopy of spheroidal modes is presented in this paper. Experimentally, by using an ultrasonic probe for the excitation (piezoelectric transducer) and a heterodyne optic probe for the receiver (interferometer), it was possible to take spectroscopic measurements of spheroidal vibrations over a large frequency range of 100 kHz-45 MHz in a continuous regime. This wide analysis range enabled variations in velocity due to the presence of defects to be differentiated from the inherent characteristics of the balls and consequently, it offers the possibility of detecting cracks independently of production variations. This kind of defect is difficult to detect because the C-shaped surface crack is very small and narrow (500x5 {mu}m{sup 2}), and its depth does not exceed 50 {mu}m. The proposed methodology can excite spheroidal vibrations in the ceramic balls and detect such vibrations over a large frequency range. On the one hand, low frequency resonances are used in order to estimate the elastic coefficients of the balls according to various inspection depths. This method has the advantage of providing highly accurate evaluations of the elastic coefficients over a wide frequency range. On the other hand, high frequency vibrations are considered because they are similar to the surface waves propagating in the surface zone of the ceramic balls and consequently can be used to detect C-crack defects.

36 MATERIALS SCIENCE↗

Time-resolved orbital angular momentum spectroscopy

We introduce pump-probe magneto-orbital spectroscopy, wherein Laguerre-Gauss optical pump pulses impart orbital angular momentum to the electronic states of a material and subsequent dynamics are studied with 100 fs time resolution. The excitation uses vortex modes that distribute angular momentum over a macroscopic area determined by the spot size, and the optical probe studies the chiral imbalance of vortex modes reflected off the sample. First observations in bulk GaAs yield transients that evolve on time scales distinctly different from population and spin relaxation, as expected, but with surprisingly large lifetimes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Giant Optical Linear Dichroism in a Zigzag Antiferromagnet FePS 3

Direct optical probing of the antiferromagnetic order parameter in atomically thin samples is challenging, for example, via magneto-optical spectroscopy, due to the lack of net magnetization. Here, we report zigzag-antiferromagnetism (AFM) induced optical linear dichroism (LD) in layered transition-metal thiophosphate FePS3 down to the monolayer limit. The observed LD is giant despite having the optical wave vector parallel to the Neel vector. The LD is at least one order of magnitude larger than those reported in other antiferromagnetic systems, where the optical wave vector is orthogonal to the Neel vector. The large LD enables the probe of 60 degrees orientated zigzag-AFM domains. The optical anisotropy in FePS 3 originates from an electronic anisotropy associated with the zigzag direction of the AFM order and is independent of the spin-pointing direction. Furthermore, our findings point to a new optical approach for the investigation and control of zigzag or stripe magnetic order in strongly correlated systems.

2D magnet↗

Chemical detection demonstrated using an evanescent wave graphene optical sensor

Graphene devices have been constructed on silicon mirrors, and the graphene is optically probed through an evanescent wave interaction in an attenuated total reflectance configuration using an infrared spectrometer. The graphene is electrically biased in order to tune its optical properties. Exposure of the device to the chemicals iodine and ammonia causes observable and reversible changes to graphene's optical absorption spectra in the mid to near infrared range which can be utilized for the purpose of sensing. Electrical current measurements through the graphene are made simultaneously with optical measurements allowing for simultaneous sensing using two separate detection modalities. Our current results reveal sub-ppm detection limits for iodine and approximately 100 ppm detection limits for ammonia. We have also demonstrated that this approach will work at 1.55 μm, which opens up the possibility for graphene optical sensors that leverage commercial telecom light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗