Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Facile All-Optical Method for In Situ Detection of Low Amounts of Ammonia

As a key precursor for nitrogenous compounds and fertilizer, ammonia affects our lives in numerous ways. Rapid and sensitive detection of ammonia is essential, both in environmental monitoring and in process control for industrial production. Here we report a novel and nonperturbative method that allows rapid detection of ammonia at low concentrations, based on the all-optical detection of surface-enhanced Raman signals. We show that this simple and affordable approach enables ammonia probing at selected regions of interest with high spatial resolution, making in situ and operando observations possible.

09 BIOMASS FUELS↗

Detection of coherent optical phonons in a thin bismuth film by ultrafast electron diffraction

Coherent dynamics of lattice oscillations in a ∼20-nm-thick film obtained by thermal sputtering of bismuth is studied using ultrashort electron bunches synchronised with femtosecond laser pulses irradiating the sample. The Fourier analysis of ultrafast electron diffraction (UED) data shows that the observed modulation of the signal is due to the ensemble of modes corresponding to optical phonons with frequencies of approximately 3, 6 and 9 THz. A conclusion is made that these peaks correspond to the manifestation of the bismuth A{sub 1g} mode (three-terahertz peak), as well as its first and second overtones, which is probably due to quantum confinement in a 20-nm Bi nanostructure. The possibility of a detailed study of the quantum-size effect in bismuth with the help of a transmission UED is analysed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavelength domain spatial frequency modulation imaging: enabling fiber optic delivery and detection

Spatial frequency modulation imaging (SPIFI) provides a simple architecture for modulating an extended illumination source that is compatible with single pixel imaging. We demonstrate wavelength domain SPIFI (WD-SPIFI) by encoding time-varying spatial frequencies in the spectral domain that can produce enhanced resolution images, like its spatial domain counterpart, spatial domain (SD) SPIFI. However, contrary to SD-SPIFI, WD-SPIFI enables remote delivery by single mode fiber, which can be attractive for applications where free-space imaging is not practical. Finally, we demonstrate a cascaded system incorporating WD-SPIFI in-line with SD-SPIFI enabling single pixel 2D imaging without any beam or sample scanning.

47 OTHER INSTRUMENTATION↗

Real-time single-element-detection structured illumination optical metrology for laser powder bed fusion

Laser powder bed fusion (LPBF) is a type of metal additive manufacturing which could benefit from improved process monitoring to improve quality control. We demonstrate, for the first time to our knowledge, the coaxial monitoring of melt track formation in steel powder with spatial frequency modulation imaging (SPIFI), an enhanced-resolution imaging technique which uses a photodiode to record one-dimensional images. Using a custom live-display software and a high-speed SPIFI geometry, we offset the SPIFI field of view from the fusing beam to monitor different regions of the LPBF melt pool and surrounding area. This demonstrates the potential of SPIFI to monitor spatial features within the melt pool in real-time with increased data efficiency.

Hunter, Scott (ORCID:0009000886150312)↗

Remote Americium Detection Using an Optical Sensor: A D-Optimal Strategy for Efficient PLS-Based Modeling

A fiber-optic visible–near-infrared absorption spectroscopy system in a glove box was demonstrated for remote quantification of Am(III) (0–500 µM) and HNO 3 (0.1–9 M) using partial least squares regression (PLSR) models. The sensor platform, featuring a simple plug-and-play spectrophotometer, can enable noninvasive, real-time monitoring of actinide process solutions. To establish a flexible PLSR model calibration strategy, a D-optimal design developed using Nd(III) in previous studies was successfully extended to an actinide system with Am(III) to effectively minimize sample set size while maintaining robust prediction performance. The results suggest strong spectral similarities between Nd(III) and Am(III) and validate Nd(III) as an effective optical surrogate for trivalent actinide species. This work also supports the generalizability of a D-optimal training set selection approach for two-factor systems. The PLS1 models for Am(III) and HNO 3 outperformed a PLS2 model and maintained reasonable performance in the presence of interfering U(VI). The resulting sensor system and multivariate approach provides a flexible and scalable solution for process monitoring, control, and safety in diverse nuclear applications.

actinide↗

Polarimetry-Enhanced Imaging towards Autonomous Solar Field and Receiver Inspections

During the typical operation of a Concentrating Solar Power (CSP) plant, a large portion of the energy (~45%) can be lost due to various imperfect conditions, such as blocking, shading, mirror soiling, tracking and canting errors, etc. It is necessary to develop efficient and effective field inspection technology to optically survey and characterize a CSP field, which can be used as an input for autonomous control, maintenance scheduling and spot repair whenever necessary to maximize the overall efficiency of the plant. In this project, We aim to apply polarimetric imaging for CSP collector and receiver inspection and develop polarimetric drone cameras (via integrating polarimetric imagers onto drones) for autonomous field inspection in CSP plants.

14 SOLAR ENERGY↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Method and apparatus for radiation detection based on time-of-flight within optical fibers

A radiation detection system using time of flight (TOF) information within multiple optical fiber complexes coupled with a scintillating material at intersections of repeatedly crossing over shape. Light detectors are placed at the ends of each fiber to detect scintillation events. A timing processor is collecting light detector signal to compute TOF difference and estimate the location and strength of radioactivity. The system is scalable in one dimension, capable of being shaped or curved, and customizable in terms of special resolution and sensitivity. The system is suitable for long range and coarse radiation detection.

Lee, Seung Jae↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber optic system for direct detection of CO 2 leakage in carbon storage wells (Abbreviated Final Report)

The feasibility study focused on the development of new fiber for distributed chemical sensing that will allow direct detection of CO2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), which can provide early warning for an incoming well failure and potential CO2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously. The methodology would overcome current roadblocks to using fiber optics for CO2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure. We were able to assess commercially available IR/Raman hollow core fiber and demonstrated detection of CO2 through them in our controlled environment setups at various pressure conditions. We have also established the ability of drilling precisely with fs-lases side holes to enable penetration of CO2 into the hollow core fiber and reduce diffusion rates. Open joint collars were also explored with double functionality: to obtain splice to solid core fiber critical for field deployment and create gas ingress locations. Both diffusion-only and pressurized fiber system have been constructed following COMSOL based semi-hybrid optical /fluidodynamics models. FBGs have been identified and procured and characterized. Along the work we leveraged internal modeling/design, photonics/laser characterization, optical fiber fabrication, and AM lab capabilities to design, develop and test in-house components or assemblies. Our results indicate the potential of HoF for CO2 downhole direct detection.

25 ENERGY STORAGE↗

Luminescence based fiber optic probe for the detection of rare earth elements

The disclosure relates to an apparatus, method and process for detecting rare earth elements. The system includes an LED powered by a first power source and a focusing lens in optical communication with the LED. A shortpass filter is in optical communication with the focusing lens; and a fiber bifurcated cable in optical communication with the shortpass filter. The system includes a probe tip in optical communication with the fiber bifurcated cable and a sample; a first aspheric lens in optical communication with the fiber bifurcated cable. A longpass filter is in optical communication with the first aspheric lens and a second aspheric lens in optical communication with the longpass filter. The system includes a spectrometer connected to a power source, where the spectrometer is in optical communication with the second aspheric lens.

Ahern, John C.↗

Fiber optic system for direct detection of CO2 leakage in carbon storage wells

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with standard solid core fibers and Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously by means of reflectometry. The methodology would overcome current roadblocks to using fiber optics for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

25 ENERGY STORAGE↗

An Assessment of Homogeneous Mixture Method Cavitation Models in Predicting Cavitation in Nozzle Flow

The homogeneous mixture method (HMM) is a popular class of models used in the computational prediction of cavitation. Several cavitation models have been developed for use with HMM to govern the development and destruction of vapor in a fluid system. Two models credited to Kunz and Schnerr–Sauer are studied in this paper. The goal of this work is to provide an assessment of the two cavitation submodels in their ability to predict cavitation in nozzle flow. Validation data were obtained via experiments which employ both passive cavitation detection, (PCD) via acoustic sensing and optical cavitation detection (OCD) via camera imaging. The experiments provide quantitative information on cavitation inception and qualitative information on the vapor in the nozzle. The results show that initial vapor formation is not predicted precisely but within reason. A sensitivity analysis of the models to input parameters shows that the Schnerr–Sauer method does not depend upon the estimation of nuclei size and number density. Small changes in the vapor formation rate but not the total vapor volume can be seen when weighting parameters are modified. In contrast, changes to the input parameters for the Kunz model greatly change the final total vapor volume prediction. The assessment also highlights the influence of vapor convection within the method. Finally, the analysis shows that if the fluid and nozzle walls do not support nuclei larger than 40 μm, the methods would still predict cavitation when indeed there would be none in practice.

Engineering↗

Using synthetic infrared spectra derived from n/k optical constants for standoff detection of chemical deposits

We report results from a recent field experiment to test the validity of using physics-based synthetic infrared spectra to serve as endmembers in a spectral database targeted at chemical deposits. Specifically, the optical constants n and k, (the real and imaginary part of the refractive index) were used to first model infrared reflectance spectra for different thicknesses of chemical layers (e.g. acetaminophen, methylphosphonic acid – MPA, etc.) on various conducting and insulating substrates such as aluminum, wood, and glass. In the experimental portion of the research, thin films of the solid and liquid analytes were deposited onto such substrates to form micron-thick layers of the analytes at different thicknesses: Standoff data from an imaging instrument were then recorded and analyzed to not only identify the different analytes, but also quantify the layer/deposit thickness. To gauge success, the detection results using the synthetic data were compared to the results from hemispherical reflectance (HRF) spectra that were collected for the same sample planchets measured in the field via standoff methods. Preliminary results indicate good agreement between the synthetic reference data as compared to the lab-measured HRF data in terms of their ability to quantitatively reduce longwave infrared data. Specifically, modeled IR spectra for acetaminophen on an aluminum planchet at various thicknesses (1, 2, 5, 10, 15, and 20 µm) were synthesized and compared with standoff field reflectance data as well as HRF laboratory reflectance spectra for two samples: a 5.2 µm- and 12.8 µm-thick layer of acetaminophen on aluminum. Using a first-order approximation, analysis of the field data estimates the thicknesses of the samples to be 2 and 10 µm for the two samples, respectively, while the HRF laboratory data yields thickness estimates of between 5-10 µm and 10 µm, respectively. Both yield reasonable estimates, with the uncertainty most likely due to factors yet to be accounted for in the synthetic spectra such as light scattering.

complex index of refraction, optical constants, hy↗

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗