Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simultaneous transmission/absorption photometry of particle-laden filters from wildland fires during the Biomass Burning Observation Project (BBOP) field campaign

Transmissivity and absorptivity measurements were carried out simultaneously in the visible (wavelength of 532 nm) at laboratory conditions using particle-laden filters obtained from a three-wavelength particle/soot absorption photometer (PSAP). Here, the particles were collected on filters from wildland fires over the Pacific Northwest during the Department of Energy Biomass Burning Observation Project (BBOP) field campaign in 2013. The objective of this investigation was to apply this measurement approach, referred to as simultaneous transmission/absorption photometry (STAP), to estimate the aerosol extinction coefficient from actual field-campaign filter aerosol, and compare results with the PSAP. The STAP approach offers several advantages over the PSAP, including estimation of the extinction coefficient from temperature measurements (avoiding the complexities associated with filter reflectivity/scattering measurements), as well as determination of the filter optical properties and filter effects on particle absorption (resulting in particle absorption enhancement). The experimental arrangement included a laser probe beam impinging normal to the particle-coated surface of a vertically mounted filter, and a thermocouple placed flush in the middle of (and in thermal contact with) the filter uncoated back surface. With this simple arrangement, the transmissivity and absorptivity were determined simultaneously at a given laser beam wavelength. The measurement repeatability was better than 0.3 K (95% confidence level) for temperature and 0.4 mW for laser power. The limit of detection for the extinction coefficient was estimated to be (8–12) Mm -1 (95% confidence level) at about 1.9 mW laser power. The extinction coefficient was determined through measurement of both PSAP blank and exposed filters. Filters were obtained from nine different aircraft flights conducted during the BBOP campaign, representing different flight patterns, days, stages of burning, landscapes, and wildland fires. The STAP extinction coefficient matched the darkness of the filter coating, however the PSAP-filter results did not follow the same order. Although there were differences in transmissivity between the two techniques, the estimated values for absorption coefficient were in good agreement.

54 ENVIRONMENTAL SCIENCES↗

Comet Bowell 1980b

Optical filter photometry, and optical and ultraviolet spectrophotometry data collected between November 1980 and June 1982 of Comet Bowell are presented. It was determined that Comet Bowell began producing significant amounts of OH, though not other species, before perihelion at a heliocentric distance near 4.6 AU. As the comet approached perihelion at 3.4 AU, OH production decreased and CN and C2 species were detected at normal concentrations. An outburst in April 1982 was dominated by OH. The grains in 1982 near perihelion showed increases in albedo between 3150 and 4500 A and 1.2 and 1.6 microns. The presence of two grains populations was suggested, together with the conclusion that Comet Bowell was physically a typical new comet entering the inner solar system from the Oort cloud for the first time.

Feldman, P. D.↗

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

State estimation Kalman filter using optical processings Noise statistics known

Reference is made to a study by Casasent et al. (1983), which gave a description of a frequency-multiplexed acoustooptic processor and showed how it was capable of performing all the individual operations required in Kalman filtering. The data flow and organization of all required operations however, were not detailed in that study. Consideration is given here to a simpler Kalman filter state estimation problem. Equally spaced time-sampled intervals (k times T sub s, with k the iterative time index) are assumed. It is further assumed that the system noise vector w and the measurement noise vector v are uncorrelated and Gaussian distributed and that the noise statistics (Q and R) and the system model (Phi, Gamma, H) are known. The error covariance matrix P and the extrapolated error covariance matrix M can thus be precomputed and the Kalman gain matrix K sub k can be precomputed and stored for each input time sample.

Jackson, J.↗

Achromatic shearing phase sensor for generating images indicative of measure(s) of alignment between segments of a segmented telescope's mirrors

An achromatic shearing phase sensor generates an image indicative of at least one measure of alignment between two segments of a segmented telescope's mirrors. An optical grating receives at least a portion of irradiance originating at the segmented telescope in the form of a collimated beam and the collimated beam into a plurality of diffraction orders. Focusing optics separate and focus the diffraction orders. Filtering optics then filter the diffraction orders to generate a resultant set of diffraction orders that are modified. Imaging optics combine portions of the resultant set of diffraction orders to generate an interference pattern that is ultimately imaged by an imager.

Stahl, H. Philip↗

A remote sensing laser fluorometer

A sensor is reported which is able to identify certain specific substances in water by means of their fluorescence spectra. In particular, the sensor detects oil, ligninsulfonates and chlorophyll. The device is able to measure the fluorescence spectra of water at ranges up to 75 m and to detect oil spills on water at altitudes up to 300 m. Blue light from a laser is used to excite the fluorescence of the target. Any light from the ambient background illumination, from the reflected laser light or from the induced fluorescence is gathered by a small telescope focused on the target. Optical filters are used to block the reflected laser light and to select the wavelengths of interest in the fluorescence spectrum of the target. The remaining light is detected with a photomultiplier tube. The amplitude of the laser induced fluorescence in the wavelength interval selected by the optical filters is displayed on a meter or strip chart recorder.

Oneill, R. A.↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

Lidar method of measurement of atmospheric extinction and ozone profiles

A description of a method of measurement of atmospheric extinction and of ozone profiles by use of the backscatter signal from a monostatic lidar is given. The central feature of the procedure involves a measurement of the ratio of the Raman backscatter returns of both the oxygen and nitrogen atmospheric content. Because the ratio of the number density of both species is known to high accuracy, the measurement itself becomes a measure of the ratio of two transmissions to altitude along with a ratio of the two system constants. The calibration measurement for determining the value of the ratio of the two system constants or electro-optical conversion constants is accomplished by a lidar measurement of identical atmospheric targets while at the same time interchanging the two optical filters in the two optical channels of the receiver. More details of the procedure are discussed. Factoring this calibrated value into the measured O2/N2 profile ratio provides a measured value of the ratio of the two transmissions. Or equivalently, it provides a measurement of the difference of the two extinction coefficients at the O2 and N2 Raman wavelengths as a function of the height.

Cooney, J. A.↗

Spectral imagery with an acousto-optic tunable filter

.A spectral imager for astronomy and aeronomy has been fabricated using collinear or non-collinear acoustooptic tunable filters (AOTFs). The AOTF provides high transparency, rapid tunability over a wide wavelength range, a capability of varying the bandwidth by more than an order of magnitude, high etendue, and linearly polarized output. Some typical observational applications of acoustooptic tunable filters used in several configurations at astronomical telescopes are demonstrated.

Smith, W. Hayden↗

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.↗

Infrared fiber coupled acousto-optic tunable filter spectrometer

A spectrometer design is introduced which combines an acoustooptic tunable filter (AOTF) and IR-transmitting flouride-glass fibers. The AOTF crystal is fabricated from TeO2 and permits random access to any wavelength in less than 50 microseconds, and the resulting spectrometer is tested for the remote analysis of gases and hydrocarbons. The AOTF spectrometer, when operated with a high-speed frequency synthesizer and optimized algorithms, permits accurate high-speed spectroscopy in the mid-IR spectral region.

Levin, K. H.↗

Acousto-optic tunable filter (AOTF) imaging spectrometer for NASA applications - System issues

A recently developed AOTF operating in the visible, 0.4-0.8 micron bandpass is presently compared with other spectrometer designs, with a view to the advantages it may uniquely offer for prospective NASA missions. Since spectral identification is accomplished by this system through the scanning of a few spectral bands, data storage requirements for spectral image analysis can be significantly reduced. Attention is given to spectral and imaging capabilities and their applicability to defense, remote sensing, and industrial uses.

Yu, Jeffrey↗