Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Identifying Organic Molecules in Space: The AstroBiology Explorer (ABE) Mission Concept

The AstroBiology Explorer (ABE) mission concept consists of a dedicated space observatory having a 60 cm class primary mirror cooled to T < 50 K equipped with medium resolution cross-dispersed spectrometers having cooled large format near- and mid-infrared detector arrays. Such a system would be capable of addressing outstanding problems in Astrochemistry and Astrophysics that are particularly relevant to Astrobiology and addressable via astronomical observation. The mission s observational program would make fundamental scientific progress in establishing the nature, distribution, formation and evolution of organic and other molecular materials in the following extra-terrestrial environments: 1) The Outflow of Dying Stars, 2) The Diffuse Interstellar Medium, 3) Dense Molecular Clouds, Star Formation Regions, and Young StellarPlanetary Systems, 4) Planets, Satellites, and Small Bodies within the Solar System, and 5 ) The Interstellar Media of Other Galaxies. ABE could make fundamental progress in all of these areas by conducting a 1 to 2 year mission to obtain a coordinated set of infrared spectroscopic observations over the 2.5-20 micron spectral range at a spectral resolution of R > 2000 of about 1500 objects including galaxies, stars, planetary nebulae, young stellar objects, and solar system objects. Keywords: Astrobiology, infrared, Explorers, interstellar organics, telescope, spectrometer, space, infrared detectors

Ennico, K. A.↗

Characterization of Dual-Band Infrared Detectors for Application to Remote Sensing

NASA Langley Research Center (LaRC), in partnership with the Rensselaer Polytechnic Institute (RPI), developed photovoltaic infrared (IR) detectors suitable at two different wavelengths using Sb-based material systems. Using lattice-matched InGaAsSb grown on GaSb substrates, dual wavelength detectors operating at 1.7 and 2.5 micron wavelengths can be realized. P-N junction diodes are fabricated on both GaSb and InGaAsSb materials. The photodiode on GaSb detects wavelengths at 1.7 micron and the InGaAsSb detector detects wavelengths at 2.2 micron or longer depending on the composition. The films for these devices are grown by metal-organic vapor phase epitaxy (MOVPE). The cross section of the independently accessed back-to-back photodiode dual band detector consists of a p-type substrate on which n-on-p GaInAsSb junction is grown, followed by a p-on-n GaSb junction. There are three ohmic contacts in this structure, one to the p-GaSb top layer, one to the n-GaSb/n-GaInAsSb layer and one to the p-type GaSb substrate. The common terminal is the contact to the n-GaSb/n-GaInAsSb layer. The contact to the n-GaSb/p-GaInAsSb region of the photodiode in the dual band is electrically connected and is accessed at the edge of the photodiode. NASA LaRC acquired the fabricated dual band detector from RPI and characterized the detector at its Detector Characterization Laboratory. Characterization results, such as responsivity, noise, quantum efficiency, and detectivity will be presented.

Abedin, M. Nurul↗

Large Detector Systems in Particle Physics Experiments & the Role Africa Will Play in Detector Technologies of the Future

In this talk, we will give a brief overview of some of the detector technologies deployed in large-scale experiments in particle physic research lab the world and through a specific Micro Pattern Gaseous Detector (MPGD) technologies example, we will discuss challenges associated to these technologies in term of production, assembly, characterization and deployment in complex detector system for the experiments. In the second half of the talk, we will initiate the discussion on the role that African countries could play in the development of detector technologies in the future for application in various field of fundamental and applied science. We will hope to engage the audience to explore initiatives under the African Strategy for Fundamental and Applied Physics (ASFAP) umbrella to encourage African research institutions and universities to invest in detector research and development (R&D) and in infrastructures dedicated aimed at covering all aspects of detector technologies and providing opportunities to generation of bright young African minds to take part in international collaboration of large-scale experiments at facilities such as the Electron Ion Collider (EIC) in the USA or the European Organization for Nuclear Research (CERN) and to contribute to the deployment and operation of detector technologies in future experiments.

Gnanvo, Kondo↗

Radiation Tests of the Extravehicular Mobility Unit Space Suit for the International Space Station Using Energetic Protons

Measurements using silicon detectors to characterize the radiation transmitted through the EMU space suit and a human phantom have been performed using 155 and 250 MeV proton beams at LLUMC. The beams simulate radiation encountered in space, where trapped protons having kinetic energies on the order of 100 MeV are copious. Protons with 100 MeV kinetic energy and above can penetrate many centimeters of water or other light materials, so that astronauts exposed to such energetic particles will receive doses to their internal organs. This dose can be enhanced or reduced by shielding - either from the space suit or the self-shielding of the body - but minimization of the risk depends on details of the incident particle flux (in particular the energy spectrum) and on the dose responses of the various critical organs. Data were taken to characterize the beams and to calibrate the detectors using the beam in a treatment room at LLUPTF, in preparation for an experiment with the same beams incident on detectors placed in a human phantom within the EMU suit. Nuclear interactions of high-energy protons in various materials produce a small flux of highly ionizing, low-energy secondary radiation. Secondaries are of interest for their biological effects, since they cause doses and especially dose-equivalents to increase relative to the values expected simply from ionization energy loss along the Bragg curve. Because many secondaries have very short ranges, they are best measured in passive track detectors such as CR-39. The silicon detector data presented here are intended to supplement the CR-39 data in regions where silicon has greater sensitivity, in particular the portion of the LET spectrum below 5 keV/micron. The results obtained in this study suggest that optimizing the radiation shielding properties of space suits is a formidable task. The naive assumption that adding mass can reduce risk is not supported by the data, which show that reducing the dose delivered at or near the skin by low-energy particles may increase the dose delivered by energetic particles to points deeper in the body.

Zeitlin, C.↗

Analysis of TATB by uHPLC-DAD (V.2.2)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an Electrochemical Hydrogen Contaminant Detector

Hydrogen refueling stations (HRSs) that dispense hydrogen to fuel cell vehicles need to ensure the quality of hydrogen to avoid contamination of the vehicle’s expensive fuel cell stacks. Currently, stations verify their fuel quality only periodically to ensure that they meet the strict fuel quality standards specified by either International Organization for Standards (ISO) or Society for Automotive Engineers (SAE). The development of hydrogen contaminant detectors (HCDs) that can provide low cost continuous monitoring at the HRS can be an invaluable asset in protecting fuel cell vehicles from any fuel contamination in-between infrequent expensive analysis of hydrogen fuel quality. An HCD capable of detecting < 200 ppb of CO in hydrogen is presented in this paper. The HCD is based on an electrochemical hydrogen pumping cell whose ultra-low loaded working electrode is poisoned by the contaminant, thus reducing its hydrogen oxidation reaction rate. The hydrogen pumping cell consists of a Nafion® membrane, a sputtered Pt working electrode, a Pt/Ru counter/pseudo-reference electrode and an internal water wicking system that provides humidification to the membrane and electrodes. When this HCD is operated in a pulsed voltammetry mode, it can provide stable CO response for thousands of hours in a HRS.

47 OTHER INSTRUMENTATION↗

Background estimation in a (gnu e)-diffusion detector

Background conditions for detecting (gamma e)-diffusion are discussed with reference to the utilization of a hodoscope system consisting of wide area flat Geiger counters connected for coincidence and of a controllable spark chamber. When calculating the background, any organic compounds synthesized from C, O2 and H2 with radioactive admixtures is presumed to be the preferrable material for the construction of the detector. The number of background events simulating the effect sought is estimated by analyzing the spectrum of the organic glass gamma radiation caused by disintegration and fission of long lived isotopes and by nuclear reactions with the participation of alpha particles and neutrons.

Glotov, V. I.↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Higher-Sensitivity Ionization Trace-Species Detector

Electron source and electron optics of reversal electron-attachment detector modified to increase sensitivity. Original version described in "High-Sensitivity Ionization Trace-Species Detector" (NPO-17596). Used to detect molecules of particular chemical species of interest (e.g., narcotics, explosives, or organic wastes) present in air at low concentrations, and known to attach extremely low-energy electrons. Apparatus does this by ionizing molecules from sampled atmosphere, then detecting ions of species of interest. Detector features indirectly heated spherical cathode and redesigned electron optics, together, deliver more electrons at low kinetic energy to reversal plane, R. Greater electron current generates more ions for detection.

Boumsellek, Said↗

Dark matter searches and energy accumulation and release in materials

Efforts to identify dark matter by detecting nuclear recoils produced by dark matter particles reveal low-energy backgrounds of unknown origin in different types of detectors. In many cases, energy accumulation and delayed burst-like releases of stored energy could provide an explanation. These dynamics follow Prigogine’s ideas on systems with energy flow and the general Self-Organized Criticality scenario. We compare these models with properties of excess backgrounds in cryogenic solid-state detectors, relaxation processes in glasses and crystals, our observations of delayed luminescence in NaI(Tl), and make predictions for more phenomena present in these systems and in superconducting photon detectors and qubits. Experiments to create accurate phenomenological models are needed.

Pereverzev, Sergey↗

Beyond the Hype: An Evaluation of Commercially Available Machine-Learning-Based Malware Detectors

There is a lack of scientific testing of commercially available malware detectors, especially those that boast accurate classification of never-before-seen (i.e., zero-day) files using machine learning (ML). Consequently, efficacy of malware detectors is opaque, inhibiting end users from making informed decisions and researchers from targeting gaps in current detectors. In this paper, we present a scientific evaluation of four prominent commercial malware detection tools to assist an organization with two primary questions: To what extent do ML-based tools accurately classify previously and never-before-seen files? Is purchasing a network-level malware detector worth the cost? To investigate, we tested each tool against 3,536 total files (2,554 or 72% malicious, 982 or 28% benign) of a variety of file types, including hundreds of malicious zero-days, polyglots, and APT-style files, delivered on multiple protocols. We present statistical results on detection time and accuracy, consider complementary analysis (using multiple tools together), and provide two novel applications of the recent cost-benefit evaluation procedure of Iannacone & Bridges. Although the ML-based tools are more effective at detecting zero-day files and executables, the signature-based tool might still be an overall better option. Both network-based tools provide substantial (simulated) savings when paired with either host tool, yet both show poor detection rates on protocols other than HTTP or SMTP. Our results show that all four tools have near-perfect precision but alarmingly low recall, especially on file types other than executables and office files—37% of malware, including all polyglot files, were undetected. Priorities for researchers and takeaways for end users are given. Code for future use of the cost model is provided.

97 MATHEMATICS AND COMPUTING↗