Search NASA⌕ Search

SEARCH · Search NASA

Results for “PAINT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Radiation sensitive paint and application thereof

A camera is used in conjunction with storage phosphor paint, configured to examine a surface. The surface is coated with storage phosphor paint in some embodiments. The camera is configured to image the surface coated with the storage phosphor paint, eliminating requirement of fast relaxation times associated with conventional scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DNA-PAINT Imaging with Hydrogel Imprinting and Clearing

Hydrogel-embedding is a versatile technique in fluorescence microscopy, offering stabilization, optical clearing, and the physical expansion of biological specimens. DNA-PAINT is a super-resolution microscopy approach based on the diffusion and transient binding of fluorescently labeled oligos, but its feasibility in hydrogels has not yet been explored. In this study, we demonstrate that polyacrylamide hydrogels support sufficient diffusion for effective DNA-PAINT imaging. Using acrydite-anchored oligonucleotides imprinted from patterned DNA origami nanostructures and microtubule filaments in fixed cells, we find that hydrogel embedding preserves docking strand positioning at the nanoscale. Sample clearing via protease treatment had minor structural effects on the microtubule structure and enhanced diffusion and accessibility to hydrogel-imprinted docking strands. Our work demonstrates promising potential for diffusion and binding-based fluorescence imaging applications in hydrogel-embedded samples.

DNA origami↗

The darkening of zinc yellow: XANES speciation of chromium in artist;s paints after light and chemical exposures

The color darkening of selected brushstrokes of the masterpiece A Sunday on La Grande Jatte - 1884 (by Georges Seurat) has been attributed to the alteration of the chromate pigment zinc yellow. The pigment originally displays a bright greenish-yellow color but may undergo, after aging, darkening to a dull, ocher tone. We used XANES to probe the oxidation state of Cr on paint reconstructions, and show that color changes are associated with the reduction of Cr(VI) to Cr(III). Paint mixtures containing the pigment and linseed oil to mimic mixtures used in La Grande Jatte were subjected to artificial aging in the presence of light, SO{sub 2}, and variable air humidity - 50 and 90% relative humidity. High relative humidity led to the largest degree of Cr(VI) reduction whereas low relative humidity promoted light-induced alterations. These results are corroborated by visible reflectance measurements on the same laboratory samples and contribute to a better understanding of the chemical reactivity of chromate pigments, which are present in many historical works of art.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commercialization of laser-induced breakdown spectroscopy for lead-in-paint inspection

A study was undertaken to determine if laser-induced breakdown spectroscopy (LIBS) can be a practical and competitive alternative to x-ray fluorescence (XRF) methods for lead-in-paint inspection. Experiments in the laboratory confirmed that LIBS is suitable for detecting lead in paint at the hazard levels defined by federal agencies. Although we compared speed, function, and cost, fundamental differences between the XRF and LIBS measurements limited our ability to make a quantitative performance comparison. While the LIBS method can achieve the required sensitivity and offers a way to obtain unique information during inspection, the current component costs will likely restrict interest in the method to niche applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nondestructive Analysis of MET-5 Paint Can at TA35 Building 2 A-Wing Vault

In Building 2 A-wing vault MET-5 has some drums and other packages they wanted NEN-1 help identifying nondestructively. Measurements using a mechanically cooled portable high-purity germanium HPGe Ortec detective were taken of a paint can container labeled DU-2A to determine if any radioactive material was inside. The HPGe detector measures the gamma rays emitted by radioactive material and displays it as a spectrum. The spectrum is used to identify this radioactive material by using appropriate analysis software and identifying the gamma ray peaks. A paint can container, DU-2A, was analyzed with PeakEasy 4.84 and FRAM 5.2. The FRAM report is shown. The enrichment is 0.091% U235 and 99.907% U238. This material is depleted uranium. The measurement was performed in the near field, and to extract a mass a far field measurement will need to be taken.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Transonic Unsteady Aerodynamic Environments using Unsteady Pressure Sensitive Paint for the Space Launch System Block 1 Cargo Launch Vehicle

Predicting launch vehicle unsteady aerodynamic loads due to buffet remains a significant challenge. Current practices for modeling buffet environments involve the development of buffet forcing functions using unsteady pressure measurements acquired during wind-tunnel tests. These practices often result in significant uncertainty in buffet environments for coupled loads analyses due to the complex spatio-temporal nature of the unsteady pressure field and challenge of its estimation using discrete sensors. Unsteady pressure sensitive paint, on the other hand, can provide unsteady pressure data at a comparatively high-spatial-density and may overcome the challenge of unsteady pressure field estimation with discrete sensors and lead to improvements in the development of buffet forcing functions. In this paper, comparisons of the fluctuating pressure field are made for the Space Launch System Block 1 cargo launch vehicle measured using unsteady pressure sensitive paint and pressure transducers.

buffet↗

Analysis of Transonic Unsteady Aerodynamic Environments using Unsteady Pressure Sensitive Paint for the Space Launch System Block 1 Cargo Launch Vehicle

Predicting launch vehicle unsteady aerodynamic loads due to buffet remains a significant challenge. Current practices for modeling buffet environments involve the development of buffet forcing functions using discrete unsteady pressure measurements acquired during wind-tunnel tests. These practices often result in significant uncertainty in buffet environments for coupled loads analyses due to the complex spatio-temporal nature of the unsteady pressure field and the challenge of its estimation using discrete sensors. Unsteady pressure sensitive paint, on the other hand, can provide unsteady pressure data at a comparatively high spatial density and may overcome the challenge of unsteady pressure field estimation with discrete sensors and lead to improvements in the development of buffet forcing functions. In this paper, comparisons of the fluctuating pressure field are made for the Space Launch System Block 1 cargo launch vehicle measured using unsteady pressure sensitive paint and pressure transducers.

buffet↗

Analysis of Transonic Unsteady Aerodynamic Environments using Unsteady Pressure Sensitive Paint for the Space Launch System Block 1 Cargo Launch Vehicle

Predicting launch vehicle unsteady aerodynamic loads due to buffet remains a significant challenge. Current practices for modeling buffet environments involve the development of buffet forcing functions using discrete unsteady pressure measurements acquired during wind-tunnel tests. These practices often result in significant uncertainty in buffet environments for coupled loads analyses due to the complex spatio-temporal nature of the unsteady pressure field and the challenge of its estimation using discrete sensors. Unsteady pressure sensitive paint, on the other hand, can provide unsteady pressure data at a comparatively high spatial density and may overcome the challenge of unsteady pressure field estimation with discrete sensors and lead to improvements in the development of buffet forcing functions. In this paper, comparisons of the fluctuating pressure field are made for the Space Launch System Block 1 cargo launch vehicle measured using unsteady pressure sensitive paint and pressure transducers.

buffet↗

Spectral Analysis of Integrated Pressures on Patches with Unsteady Pressure-Sensitive Paint Measurements

The technique of Pressure-Sensitive Paint (PSP) is commonly used in the aerospace industry to measure surface pressures on the model of launch vehicles and airplanes in the wind tunnel test. Recent research has demonstrated that Unsteady Pressure-Sensitive Paint (uPSP) can be an essential tool for the assessment of the unsteady, aerodynamic phenomena. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. This paper describes the spectral analysis of integrated pressures on patches of the scale model of the Space Launch System (SLS) Block 1 cargo vehicle with the uPSP measurements, which were collected in the Ascent Transient Aerodynamics Test (ATAT) with the Unitary Plan Wind Tunnel 11-by-11-foot Transonic Wind Tunnel in September 2019 at NASA Ames Research Center. The patches are defined with x station values, indicating the position along length of the SLS vehicle, and azimuth angles of the scale model. For each patch, the polygons are determined from the surface cells of the grid of the model, clipped with the edges of the patch, and each of the polygons is divided into triangles. The integrated pressure of the patch is determined as the ratio of the sum of the forces on the triangles over the sum of the areas of the triangles. For each run of the test, the Cross Power Spectral Density (CPSD) and magnitude squared coherence are computed from the time series of the integrated pressures on the patches. The pressure integration is coded in C++ and the spectral analysis is coded in MATLAB. The results were generated with the execution of the compiled C++ and MATLAB codes in parallel on the NASA Pleiades supercomputer. The results of pressure integration and spectral analysis are presented in this paper, and the data consistency of the test is also demonstrated. Funding for this research was provided by the NASA Aerosciences Evaluation and Test Capabilities Project.

Pressure-Sensitive Paint↗

Launch Vehicle Loads Analysis Using Pressure-Sensitive Paint

Pressure transducers have been the instrumentation of choice for measuring unsteady flow phenomena. With recent advances in high-speed cameras, high-powered LEDs, and fast-response, pressure-sensitive paint, the unsteady pressure-sensitive paint (uPSP) technique has become a valuable alternative for production wind tunnel facilities, enabling time-resolved measurements of unsteady pressure fluctuations over a dense spatial grid on a wind tunnel model. Launch vehicle ground tests have proven to be a particularly well-matched application for uPSP due to the high signal level relative to tunnel background acoustics, relatively simple camera optical access, and rigidity of the model in wind-on test conditions. This presentation will highlight recent advances in data reduction of uPSP measurement data from recent launch vehicle wind tunnel tests at the NASA Ames Unitary Plan Wind Tunnel Complex (UPWT). The system can provide both localized surface pressure spectra as well as regional or zonal estimates of turbulence correlation model parameters. In addition, integrated vehicle-scale loads can be provided for buffet analysis. Data is reduced at the on-premise NASA Advanced Supercomputer (NAS) Division for just-in-time delivery of results during an ongoing wind tunnel test.

Pressure-Sensitive Paint↗

Noise Reduction and Calibration for Aeroacoustic Loads from Unsteady Pressure-Sensitive Paint

Unsteady pressure-sensitive paint (uPSP) is a significant new technology for high spatial resolution measurement of complex dynamic surface pressure loading on a wind tunnel model, to better define flight vehicle buffet and aeroacoustic loads. Compared with the very sparse surface pressure measurements of traditional sensors, the pressure sensitivity of uPSP light reflectivity provides a visual measure of surface pressure fluctuations over a wide area illuminated by high intensity light, captured by a high-speed digital camera. Panda et al (AIAA Journal, May 2019) have shown good data is recoverable up to 10 kHz. In cases where available uPSP luminescence is low for a painted wind tunnel test model, significant noise levels have been observed primarily due to the discrete photon arrival variability of low intensity light (termed “shot noise”). In this case, uPSP measurements can exhibit unusually low signal to noise ratio (SNR of 0.1 or less). This paper will report on latest work to recover calibrated uPSP measurements which are noise free over a useful dynamic range of 10-15 dB. It will be shown how the distinct spatial correlations of both the shot noise and the underlying aeroacoustic surface pressure play an important role in obtaining a reliable measurement.

pressure-sensitive paint↗

Launch Vehicle Loads Analysis Using Pressure-Sensitive Paint

Pressure transducers have been the instrumentation of choice for measuring unsteady flow phenomena. With recent advances in high-speed cameras, high-powered LEDs, and fast-response, pressure-sensitive paint, the unsteady pressure-sensitive paint (uPSP) technique has become a valuable alternative for production wind tunnel facilities, enabling time-resolved measurements of unsteady pressure fluctuations over a dense spatial grid on a wind tunnel model. Launch vehicle ground tests have proven to be a particularly well-matched application for uPSP due to the high signal level relative to tunnel background acoustics, relatively simple camera optical access, and rigidity of the model in wind-on test conditions. This presentation will highlight recent advances in data reduction of uPSP measurement data from recent launch vehicle wind tunnel tests at the NASA Ames Unitary Plan Wind Tunnel Complex (UPWT). The system can provide both localized surface pressure spectra as well as regional or zonal estimates of turbulence correlation model parameters. In addition, integrated vehicle-scale loads can be provided for buffet analysis. Data is reduced at the on-premise NASA Advanced Supercomputer (NAS) Division for just-in-time delivery of results during an ongoing wind tunnel test.

pressure-sensitive paint↗

Coherent x-ray diffraction imaging of paint pigmentparticles by scanning a phase plate modulator

We have implemented a coherent x-ray diffraction imaging technique that scans a phase plate to modulate wave-fronts of the x-ray beam transmitted by samples. The method was applied to measure a decorative alkyd paint containing iron oxide red pigment particles. By employing an iterative algorithm for wave-front modulation phase retrieval, we obtained an image of the paint sample that shows the distribution of the pigment particles and is consistent with the result obtained from a transmission x-ray microscope. The technique has been experimentally proven to be a feasible coherent x-ray imaging method with about 120 nm spatial resolution and was shown to work well with industrially relevant specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-Stabilisation and UV Blocking Efficacy of Coated Macro and Nano-Rutile Titanium Dioxide Particles in Paints and Coatings

Surface treated macro and nanoparticle TiO{sub 2} samples have been prepared, characterised and their efficiency as UV blockers evaluated in clear coatings and paints. The particle size of the ‘base’ TiO{sub 2} has been optimised to block UV radiation and the surface treatment developed to deactivate the photocatalytic activity of the surface of the TiO{sub 2} particles. The resultant UV blockers have been evaluated in both solvent and water-based clear coatings. Nanoparticle TiO{sub 2} has been prepared from ‘seed’ and the particle size was controlled by calcination. It was found that the choice of particle size is a compromise between UVA absorption, UVB absorption, visible transmission and photoactivity. It has been demonstrated that TiO{sub 2} with a crystallite size of 25 nm yields a product with the optimum properties. A range of dispersants was successfully used to disperse and mill the TiO{sub 2}. Both organic and inorganic dispersants were used; 2-amino-2-methyl-1-propanol and 1-amino-2-propanol (MIPA) and P{sub 2}O{sub 5} and Na{sub 2}SiO{sub 3} respectively. The surface of the nano-TiO{sub 2} was coated with mixed oxides of silicon, aluminium, zirconium and phosphorous. Addition of the resultant coated nano-rutiles to an Isocyanate Acrylic clear coating prolonged the lifetime of that coating compared to the blank. Generally, a surface treatment based on SiO{sub 2}, Al{sub 2}O{sub 3} and P{sub 2}O{sub 5} was more successful than one based on ZrO{sub 2}, Al{sub 2}O{sub 3} and P{sub 2}O{sub 5}. Higher addition levels of the surface treatment were beneficial for protecting the polymeric coating. The UV blocker products were also evaluated in a water-based acrylic, first a water-based dispersion of the UV blocker was prepared before addition to the acrylic. The dispersions and resultant acrylic thin films were evaluated using UV/Vis spectroscopy and durability assessed. The ratio of absorbance at 300:500 nm for the water-based dispersion was shown to be a good predictor of both the transparency of the resultant acrylic thin film and the durability of that film, in terms of weight loss. Macro grade titanium dioxide pigments were also prepared and coated with treatments of silica, alumina and siloxane and their photo-stabilising activity in alkyd paint film assessed and found to be directly related to the electron–hole pair mobility and trapping as determined by micro-wave spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To investigate the feasibility of adaptive intensity-modulated radiation therapy (IMRT) using dose painting by numbers (DPBN) for head-and-neck cancer. Methods and Materials: Each patient's treatment used three separate treatment plans: fractions 1-10 used a DPBN ([{sup 18}-F]fluoro-2-deoxy-D-glucose positron emission tomography [{sup 18}F-FDG-PET]) voxel intensity-based IMRT plan based on a pretreatment {sup 18}F-FDG-PET/computed tomography (CT) scan; fractions 11-20 used a DPBN plan based on a {sup 18}F-FDG-PET/CT scan acquired after the eighth fraction; and fractions 21-32 used a conventional (uniform dose) IMRT plan. In a Phase I trial, two dose prescription levels were tested: a median dose of 80.9 Gy to the high-dose clinical target volume (CTV{sub highdose}) (dose level I) and a median dose of 85.9 Gy to the gross tumor volume (GTV) (dose level II). Between February 2007 and August 2009, 7 patients at dose level I and 14 patients at dose level II were enrolled. Results: All patients finished treatment without a break, and no Grade 4 acute toxicity was observed. Treatment adaptation (i.e., plans based on the second {sup 18}F-FDG-PET/CT scan) reduced the volumes for the GTV (41%, p = 0.01), CTV{sub highdose} (18%, p = 0.01), high-dose planning target volume (14%, p = 0.02), and parotids (9-12%, p < 0.05). Because the GTV was much smaller than the CTV{sub highdose} and target adaptation, further dose escalation at dose level II resulted in less severe toxicity than that observed at dose level I. Conclusion: To our knowledge, this represents the first clinical study that combines adaptive treatments with dose painting by numbers. Treatment as described above is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Positron Emission Tomography: Implications for Dose Painting of High-Uptake Regions

Purpose: To investigate the behavior of tumor subvolumes of high [18F]-fluorodeoxyglucose (FDG) uptake as seen on clinical four-dimensional (4D) FDG-positron emission tomography (PET) scans. Methods and Materials: Four-dimensional FDG-PET/computed tomography scans from 13 patients taken before radiotherapy were available. The analysis was focused on regions of high uptake that are potential dose-painting targets. A total of 17 lesions (primary tumors and lymph nodes) were analyzed. On each one of the five phases of the 4D scan a classification algorithm was applied to obtain the region of highest uptake and segment the tumor volume. We looked at the behavior of both the high-uptake subvolume, called 'Boost,' and the segmented tumor volume, called 'Target.' We measured several quantities that characterize the Target and Boost volumes and quantified correlations between them. Results: The behavior of the Target could not always predict the behavior of the Boost. The shape deformation of the Boost regions was on average 133% higher than that of the Target. The gross to internal target volume expansion was on average 27.4% for the Target and 64% for the Boost, a statistically significant difference (p < 0.05). Finally, the inhale-to-exhale phase (20%) had the highest shape deformation for the Boost regions. Conclusions: A complex relationship between the measured quantities for the Boost and Target volumes is revealed. The results suggest that in cases in which advanced therapy techniques such as dose painting are being used, a close examination of the 4D PET scan should be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Painted Intensity-Modulated Radiation Therapy for Anal Cancer: A Multi-Institutional Report of Acute Toxicity and Response to Therapy

Purpose: Chemoradiation for anal cancer yields effective tumor control, but is associated with significant acute toxicity. We report our multi-institutional experience using dose-painted IMRT (DP-IMRT). Patients and Methods: Between August 2005 and May 2009, 43 patients were treated with DP-IMRT and concurrent chemotherapy for biopsy-proven, squamous cell carcinoma of the anal canal at two academic medical centers. DP-IMRT was prescribed as follows: T2N0: 42 Gy, 1.5 Gy/fraction (fx) to elective nodal planning target volume (PTV) and 50.4 Gy, 1.8 Gy/fx to anal tumor PTV; T3-4N0-3: 45 Gy, 1.5 Gy/fx to elective nodal PTV, and 54 Gy, 1.8 Gy/fx to the anal tumor and metastatic nodal PTV >3 cm with 50.4 Gy, 1.68 Gy/fx to nodal PTVs {<=}3 cm in size. Acute and late toxicity was reported by the treating physician. Actuarial analysis was performed using the Kaplan-Meier method. Results: Median age was 58 years; 67% female; 16% Stage I, 37% II; 42% III; 5% IV. Fourteen patients were immunocompromised: 21% HIV-positive and 12% on chronic immunosuppression. Median follow-up was 24 months (range, 0.6-43.5 months). Sixty percent completed chemoradiation without treatment interruption; median duration of treatment interruption was 2 days (range, 2-24 days). Acute Grade 3+ toxicity included: hematologic 51%, dermatologic 10%, gastrointestinal 7%, and genitourinary 7%. Two-year local control, overall survival, colostomy-free survival, and metastasis-free survival were 95%, 94%, 90%, and 92%, respectively. Conclusions: Dose-painted IMRT appears effective and well-tolerated as part of a chemoradiation therapy regimen for the treatment of anal canal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Deformable Image Coregistration in Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To assess the accuracy of contour deformation and feasibility of dose summation applying deformable image coregistration in adaptive dose painting by numbers (DPBN) for head and neck cancer. Methods and Materials: Data of 12 head-and-neck-cancer patients treated within a Phase I trial on adaptive {sup 18}F-FDG positron emission tomography (PET)-guided DPBN were used. Each patient had two DPBN treatment plans: the initial plan was based on a pretreatment PET/CT scan; the second adapted plan was based on a PET/CT scan acquired after 8 fractions. The median prescription dose to the dose-painted volume was 30 Gy for both DPBN plans. To obtain deformed contours and dose distributions, pretreatment CT was deformed to per-treatment CT using deformable image coregistration. Deformed contours of regions of interest (ROI{sub def}) were visually inspected and, if necessary, adjusted (ROI{sub def{sub ad}}) and both compared with manually redrawn ROIs (ROI{sub m}) using Jaccard (JI) and overlap indices (OI). Dose summation was done on the ROI{sub m}, ROI{sub def{sub ad}}, or their unions with the ROI{sub def}. Results: Almost all deformed ROIs were adjusted. The largest adjustment was made in patients with substantially regressing tumors: ROI{sub def} = 11.8 {+-} 10.9 cm{sup 3} vs. ROI{sub def{sub ad}} = 5.9 {+-} 7.8 cm{sup 3} vs. ROI{sub m} = 7.7 {+-} 7.2 cm{sup 3} (p = 0.57). The swallowing structures were the most frequently adjusted ROIs with the lowest indices for the upper esophageal sphincter: JI = 0.3 (ROI{sub def}) and 0.4 (ROI{sub def{sub ad}}); OI = 0.5 (both ROIs). The mandible needed the least adjustment with the highest indices: JI = 0.8 (both ROIs), OI = 0.9 (ROI{sub def}), and 1.0 (ROI{sub def{sub ad}}). Summed doses differed non-significantly. There was a trend of higher doses in the targets and lower doses in the spinal cord when doses were summed on unions. Conclusion: Visual inspection and adjustment were necessary for most ROIs. Fast automatic ROI propagation followed by user-driven adjustment appears to be more efficient than labor-intensive de novo drawing. Dose summation using deformable image coregistration was feasible. Biological uncertainties of dose summation strategies warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗