Search NASA⌕ Search

SEARCH · Search NASA

Results for “PDMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Surface Bacterial-Spore Assay Using Tb3+/DPA Luminescence

Equipment and a method for rapidly assaying solid surfaces for contamination by bacterial spores are undergoing development. The method would yield a total (nonviable plus viable) spore count of a surface within minutes and a viable-spore count in about one hour. In this method, spores would be collected from a surface by use of a transparent polymeric tape coated on one side with a polymeric adhesive that would be permeated with one or more reagent(s) for detection of spores by use of visible luminescence. The sticky side of the tape would be pressed against a surface to be assayed, then the tape with captured spores would be placed in a reader that illuminates the sample with ultraviolet light and counts the green luminescence spots under a microscope to quantify the number of bacterial spores per unit area. The visible luminescence spots seen through the microscope would be counted to determine the concentration of spores on the surface. This method is based on the chemical and physical principles of methods described in several prior NASA Tech Briefs articles, including Live/Dead Spore Assay Using DPA-Triggered Tb Luminescence (NPO-30444), Vol. 27, No. 3 (March 2003), page 7a. To recapitulate: The basic idea is to exploit the observations that (1) dipicolinic acid (DPA) is present naturally only in bacterial spores; and (2) when bound to Tb3+ ions, DPA triggers intense green luminescence of the ions under ultraviolet excitation; (3) DPA can be released from the viable spores by using L-alanine to make them germinate; and (4) by autoclaving, microwaving, or sonicating the sample, one can cause all the spores (non-viable as well as viable) to release their DPA. One candidate material for use as the adhesive in the present method is polydimethysiloxane (PDMS). In one variant of the method for obtaining counts of all (viable and nonviable) spores the PDMS would be doped with TbCl3. After collection of a sample, the spores immobilized on the sticky tape surface would be lysed by heating or microwaving to release their DPA. Tb3+ ions from the TbCl3 would become bound to the released DPA. The tape would then be irradiated with ultraviolet and examined as described above. In another variant of the method - for obtaining counts of viable spores only - the PDMS would be doped with L-alanine in addition to TbCl3. As now envisioned, a fully developed apparatus for implementing this method would include a pulsed source of ultraviolet light and a time-gated electronic camera to record the images seen through the microscope during a prescribed exposure interval at a prescribed short time after an ultraviolet pulse. As in the method of the second-mentioned prior article, the pulsing and time-gating would be used to discriminate between the longer-lived Tb3+/DPA luminescence and the shorter-lived background luminescence in the same wavelength range. In a time-gated image, the bright luminescence from bacterial spores could easily be seen against a dark background.

Ponce, Adrian↗

Subtask 2.5 – Syngas Testing of NETL's Advanced Precombustion CO2 Capture Solvent

U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) on-site researchers have been examining and developing a novel solvent for precombustion capture that has the potential for improved performance and lower costs compared to Selexol™ and Rectisol®. In Subtask 2.5, the Energy & Environmental Research Center (EERC) conducted actual comparison tests on actual coal-derived syngas of a PEGDME (polyethylene glycol dimethyl ether) Selexol-type solvent and three other solvents provided by NETL. One was a new hybrid PEG–PDMS (poly[dimethylsiloxane]) solvent engineered by NETL. In addition, two commercially available chemicals that are projected to have good CO2 capture abilities were also selected for testing on actual coal-derived syngas. These tests were conducted in the EERC high-pressure fluid-bed gasifier (HPFBG) system utilizing an existing gas-sweetening absorption system (GSAS) to test the solvents. The four solvents tested were Solvent 1 – AGR II from Coastal Chemical Co., LLC, NETL Solvent 2 – XG-3229 Bis(methoxytriethyleneoxypropyl)hexamethyltrisiloxane, as manufactured by Gelast, Inc.; Solvent 3 – CASSH-1 (diethyl sebacate), procured from Sigma Aldrich; and Solvent 4 – TBP (tributyl phosphate), purchased from ThermoFisher Scientific. The solvents were all tested at a consistent syngas flow and composition at approximately 50 bar to make direct comparisons easier; two solvent flow rates which would bracket 90% CO2 capture; and, temperatures of 10°, 25°, 40°, and 55°C to determine the effects of temperature on CO2 uptake and CO2 to H2 selectivity. Figure E-1 shows the results for CO2 uptake and selectivity for the various solvents. These data show that the CO2 uptake for the Selexol-type solvent for the PEG-PDMS-3 and CASHH-1 solvents at higher operating temperatures around 40°C was better than the Selexol-type solvent was able to achieve at the lower operating temperature of 10°C. Selectivity of CO2 over H2 was at least as good as Selexol for the PEG-PDMS-3 solvent and even better than Selexol for the CASSH-1 solvent. The TBP solvent also displayed good CO2 uptake; however, CO2/H2 selectivity was worse than for the Selexol-type solvent. Operation of precombustion CO2 solvents at temperatures above ambient can provide a 2% process efficiency improvement along with a significant capital cost reduction since refrigeration and solvent dehydration equipment is not required. The excellent results from these tests warrant further longer-duration testing with one or both superior NETL-provided solvents to determine if longer-term exposure to any coal-derived syngas trace species may have an adverse impact on solvent performance. This project was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233.

01 COAL, LIGNITE, AND PEAT↗

Double-Layer Morphologies from a Silicon-Containing ABA Triblock Copolymer

A combined experimental and self-consistent-field theoretical (SCFT) investigation of the phase behavior of poly(stryrene-b-dimethylsiloxane-b-styrene) (PS-b-PDMS-b-PS, or SDS32) thin films during solvent vapor annealing is presented. The morphology of the triblock copolymer is described as a function of the as-cast film thickness and the ratio of two different solvent vapors, toluene and heptane. SDS32 formed terraced bilayer morphologies even when the film thickness was much lower than the commensurate thickness. The morphology transitioned between bilayer cylinders, bilayer perforated lamellae, and bilayer lamellae, including mixed structures such as a perforated lamella on top of a layer of in-plane cylinders, as the heptane fraction during solvent annealing increased. SCFT modeling showed the same morphological trends as a function of the block volume fraction. In comparison with diblock PS-b-PDMS with the same molecular weight, the SDS32 offers a simple route to produce a diversity of well-ordered bilayer structures with smaller feature sizes, including the formation of bilayer perforated lamellae over a large process window.

36 MATERIALS SCIENCE↗

Literature Review: Silicone Applications in Health Care

Early in the 20 th century, the term ‘silicone’ was coined by Professor Frederic Stanley Kipping, a British chemist and one of the founding fathers of silicon chemistry. The word was given to describe new compounds containing a Si-O linkage (siloxane bond) and basic chemical formula R 2 -Si-O. In industry, silicone usually refers to linear polydimethylsiloxane (PDMS), the most basic silicone polymer containing only methyl groups as substituents in the polymeric structure. However, the term silicone can also be used to describe complex polymer structures that feature a wide range of functional groups, branching or crosslinking. “The properties of basic PDMS materials can be changed by replacing some methyl groups with other organic groups or atoms.” Substitution of this type is useful when specific physical and chemical properties are required of the material, such as adhesion or compatibility with a certain substrate.

36 MATERIALS SCIENCE↗

Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring

Flexible pressure sensors have many potential applications in wearable electronics, robotics, health monitoring, and more. In particular, liquid-metal-based sensors are especially promising as they can undergo strains of over 200% without failure. However, current liquid-metal-based strain sensors are incapable of resolving small pressure changes in the few kPa range, making them unsuitable for applications such as heart-rate monitoring, which require a much lower pressure detection resolution. In this paper, a microfluidic tactile diaphragm pressure sensor based on embedded Galinstan microchannels (70 µm width × 70 µm height) capable of resolving sub-50 Pa changes in pressure with sub-100 Pa detection limits and a response time of 90 ms is demonstrated. An embedded equivalent Wheatstone bridge circuit makes the most of tangential and radial strain fields, leading to high sensitivities of a 0.0835 kPa -1 change in output voltage. The Wheatstone bridge also provides temperature self-compensation, allowing for operation in the range of 20–50 °C. Finally, as examples of potential applications, a polydimethylsiloxane (PDMS) wristband with an embedded microfluidic diaphragm pressure sensor capable of real-time pulse monitoring and a PDMS glove with multiple embedded sensors to provide comprehensive tactile feedback of a human hand when touching or holding objects are demonstrated.

47 OTHER INSTRUMENTATION↗

Effect of cross-link density on carbon dioxide separation in polydimethylsiloxane-norbornene membranes

The development of high performance materials for CO 2 separation and capture will significantly contribute to a solution for climate change. In this work, (bicycloheptenyl) ethyl terminated polydimethylsiloxane (PDMSPNB) membranes with varied cross-link densities were synthesized via ring-opening metathesis polymerization. The developed polymer membranes show higher permeability and better selectivity than those of conventional cross-linked PDMS membrane. The achieved performance (CO 2 permeability ~ 6800 Barrer and CO 2 /N 2 selectivity ~ 14) is very promising for practical applications. The key to achieving this high performance is the use of an in-situ cross-linking method of the difunctional PDMS macromonomers, which provides lightly cross-linked membranes. By combining positron annihilation lifetime spectroscopy, broadband dielectric spectroscopy and gas solubility measurements, we have elucidated the key parameters necessary for achieving their excellent performance.

36 MATERIALS SCIENCE↗

3D Printing Amorphous Polysiloxane Terpolymers via Vat Photopolymerization

Abstract Photocuring and vat photopolymerization (VP) additive manufacturing (AM) is reported for two families of fully amorphous poly(dimethyl siloxane) (PDMS) terpolymers containing either diphenylsiloxy (DiPhS) or diethylsiloxy (DiEtS) repeating units. A thiol‐functionalized PDMS crosslinker enables rapid crosslinking in air using efficient thiol–ene addition. Differential scanning calorimetry and dynamic mechanical analysis (DMA) confirm the absence of crystallinity for the DiPhS‐containing systems, while DMA shows a rubbery plateau extending to greater than 200 °C for the DiEtS‐containing system. VP‐AM of both photopolymer systems afford well‐defined 3D geometries, including high aspect ratio structures, which demonstrate feasibility of these photopolymers for the 3D printing of unique geometric objects that require elastomeric performance to temperatures as low as −120 °C.

Sirrine, Justin M.↗

Synthesis and characterization of porous polydimethylsiloxane structures with adjustable porosity and pore morphology using emulsion templating technique

Abstract Porous polydimethylsiloxane (PDMS) framework with adjustable pore structures has been fabricated by polymerization of the continuous phase in the emulsion templates. Different types of surfactants, including nonionic (Triton X‐100), cationic (Benzalkonium chloride), anionic (sodium dodecyl sulfate), and silicone‐based block copolymer were used to stabilize the water‐in‐oil emulsion system. Deionized water with a wide range of internal phases varying from 10% to 60% by weight was employed to make the low internal phase emulsion and medium internal phase emulsion. The effect of surfactant type, surfactant concentration, and the internal phase volume on the stability of the emulsion, pore morphology, and pore size distribution was explored. The stability of the emulsion was investigated by comparing the pore morphology of the cured sample at different set times, such as 0, 6, and 72 h. Scanning electron microscopy was employed for the characterization of the porous structures. The image analysis was conducted, and the pore size distribution, porosity, and open‐cell ratio of each sample were calculated. Interconnected pores have been seen in the porous PDMS made from emulsions with an internal phase larger than 30%. The results demonstrated that the frequency of open‐cell pores and the pore size is dependent on the surfactant types.

Abshirini, Mohammad↗

Highly stretchable miniature strain sensor for large dynamic strain measurement

In this paper, a new type of highly stretchable strain sensor was developed to measure large strains. The sensor was based on the piezo-resistive response of carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite thin films. The piezo-resistive response of CNT composite gives accurate strain measurement with high frequency response, while the ultra-soft PDMS matrix provides high flexibility and ductility for large strain measurement. Experimental results show that the CNT/PDMS sensor measures large strains (up to 8 %) with an excellent linearity and a fast frequency response. The new miniature strain sensor also exhibits much higher sensitivities than the conventional foil strain gages, as its gauge factor is 500 times of that of the conventional foil strain gages.

47 OTHER INSTRUMENTATION↗

Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to procedure type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring

PurposeRadiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions.Materials and MethodsMedical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose.ResultsPersonalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm{sup 2} versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm{sup 2}, p = 0.002].ConclusionPersonalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fully embedded CuNWs/PDMS conductor with high oxidation resistance and high conductivity for stretchable electronics

Currently, copper nanowires (CuNWs) based conductors have been considered as a promising candidate in the area of stretchable electronics. But the fast degradation of CuNWs in ambient conditions largely limited their practical applications. Here, the author reports a highly conductive, stable, and stretchable conductor with CuNWs fully embedded in the surface layer of poly(dimethylsiloxane) (PDMS), which not only exhibit superb stability against oxidation, but also possess good conductivity. In the fully embedded conductor, PDMS protects the CuNWs from oxidation and increases the mechanical robustness of CuNWs networks at the same time. The stretchable conductor could maintain a low sheet resistance even after 1000 cycles of stretching under 30% of strain. In addition, fully embedded CuNWs/PDMS conductors have excellent oxidation stability even in high humidity and high temperature environments (85 °C, 85 % RH). Stretchable dipole antenna was fabricated using the fully embeded CuNWs/PDMS conductors, which could retain its sensitivity to specific radio frequencies even after 500 cycles of the stretching/releasing process. At the same time, a stretchable conductive heater was demonstrated, verifying the applicability of our fully embedded conductor. We believe that this work could opens new opportunities for CuNW-based conductor into broad practical applications.

Zhang, Bowen (ORCID:000000030432745X)↗

Modification of carbonyl iron particles by carboxyl-containing polydimethylsiloxanes

The possibility of preparing magnetic particles with the “core–shell” structure was demonstrated. The procedure is based on the treatment of carbonyl iron particles with polydimethylsiloxanes (PDMS) containing terminal or distributed over the chain carboxyl groups attached via the alkyl or aryl spacer. The presence of carboxyl-containing PDMS grafted to the surface of carbonyl iron particles was revealed by electron microscopy. Magnetorheological fluids and magnetic elastomers containing magnetic particles with the “core–shell” structure were obtained, and their rheological properties were studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Gas-Phase Ion Structures of Locally Polar Homopolymers Through High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

The strong synergy arising from coupling two orthogonal analytical techniques such as ion mobility and mass spectrometry can be used to separate complex mixtures and determine structural information of analytes in the gas phase. A tandem study is performed using two systems with different gases and pressures to ascertain gas-phase conformations of homopolymer ions. Aside from spherical and stretched configurations, intermediate configurations formed by a multiply charged globule and a “bead-on-a-string” appendix are confirmed for polyethylene-glycol (PEG), polycaprolactone (PCL), and polydimethylsiloxane (PDMS). These intermediate configurations are shown to be ubiquitous for all charge states and masses present. For each charge state, configurations evolve in two distinctive patterns: an inverse evolution which occurs as an elementary charge attached to the polymer leaves the larger globule and incorporates itself into the appendage, and a forward evolution which reduces the globule without relinquishing a charge while leaving the appendix relatively constant. Forward evolutions are confirmed to form self-similar family shapes that transcend charge states for all polymers. Identical structural changes occur at the same mass over charge regardless of the system, gas or pressure strongly suggesting that conformations are only contingent on number of charges and chain length, and start arranging once the ion is at least partially ejected from the droplet, supporting a charge extrusion mechanism. Configurational changes are smoother for PDMS which is attributed to the larger steric hindrance caused by protruding pendant groups. This study has implications in the study of the configurational space of more complex homopolymers and heteropolymers. .

74 ATOMIC AND MOLECULAR PHYSICS↗

A monolayer microfluidic device supporting mouse spermatogenesis with improved visibility

In our previous study, we produced a microfluidic device (MFD) which successfully maintained spermatogenesis for over 6 months in mouse testis tissues loaded in the device. In the present study, we developed a new MFD, a monolayer device (ML-D) with a barrier structure consisting of pillars and slits, which is simpler in design and easier to make. This ML-D was also effective for inducing mouse spermatogenesis and maintained it for a longer period than the conventional culture method. In addition, we devised a way of introducing sample tissue into the device during its production, just before bonding the upper layer of polydimethylsiloxane (PDMS) and bottom glass slide. The tissue can obtain nutrients horizontally from the medium running beside it and oxygen vertically from above through PDMS. In addition, the glass slide set at the bottom improved the visibility of the sample tissue with an inverted microscope. When we took photos of cultured tissue of the Acr-Gfp transgenic mouse testis in ML-D sequentially every day, morphological changes of the acrosome during spermiogenesis were successfully recorded. The ML-D is simple in design and useful for culturing testis tissue for inducing and maintaining spermatogenesis with clearer visibility. Due to the new method of sample loading, tissues other than testis should also be applicable.

60 APPLIED LIFE SCIENCES↗

Selective solid-phase microextraction of explosives using fibers coated with the La (III) complex of p-di (4,4,5,5,6,6,6-hepafluoro-1,3-hexanediony) benzene

This research demonstrates enhanced capture of explosives on polydimethylsiloxane (PDMS) solid-phase microextraction (SPME) fibers coated with a metal beta-diketonate polymer, [La(III) complex of p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene, La(dihed)], compared to PDMS control fibers. SPME sampling was performed in an explosives bunker where the concentration of 2,4,6-trinitrotoluene (TNT) was estimated at less than 3 parts-per-trillion (v/v). Analysis by gas chromatography/mass spectrometry showed an approximate ten-fold enhancement in the quantity of 2,4-dinitrotoluene captured on La(dihed) over the control fiber. La(dihed) sampling also resulted in a strong signal for TNT, whereas this explosive was well below the detection limit (1 pg on fiber) on the control fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust galactomannan/graphene oxide film with ultra-flexible, gas barrier and self-clean properties

Here, this study examines a facile technology to manufacture food packaging alternatives with superior mechanical, ultra-flexible, gas barrier and self-cleaning properties, based on green and benign starting materials. A novel galactomannan (GM) was isolated from the Sesbania cannabina seeds, which was used as a matrix for the fabrication of GM-based films. Inspired by the brick-and-mortar structure of natural nacre, a facile method was adopted to fabricate an artificial nacre based on the self-assembly of GM and borate crosslinked graphene oxide (GO). These GM/GO composites are ultra-flexible, which can be folded into various shapes. The tensile strength reached 135.54 MPa which is 2.40 times that of the pure GM film. In addition, after coating with the poly(dimethylsiloxane) (PDMS), these films became hydrophobic (WCA around 120°) with self-cleaning properties. Our study further revealed that the oxygen and water vapor permeabilities were improved with the introduction of GO and PDMS coating.

36 MATERIALS SCIENCE↗

Carbon nanotube based pressure sensor for flexible electronics

Highlights: • The electromechanical change of vertically aligned carbon nanotubes. • Fabrication of CNT field-effect transistor on flexible substrate. • CNT based FET integrated active pressure sensor. • The integrated device yields an increase in the source-drain current under pressure. - Abstract: A pressure sensor was developed based on an arrangement of vertically aligned carbon nanotubes (VACNTs) supported by a polydimethylsiloxane (PDMS) matrix. The VACNTs embedded in the PDMS matrix were structurally flexible and provided repeated sensing operation due to the high elasticities of both the polymer and the carbon nanotubes (CNTs). The conductance increased in the presence of a loading pressure, which compressed the material and induced contact between neighboring CNTs, thereby producing a dense current path and better CNT/metal contacts. To achieve flexible functional electronics, VACNTs based pressure sensor was integrated with field-effect transistor, which is fabricated using sprayed semiconducting carbon nanotubes on plastic substrate.

36 MATERIALS SCIENCE↗