Materials Compatibility Testing in Concentrated Hydrogen Peroxide

Materials test methods from the 1960's have been used as a starting point in evaluating materials for today's space launch vehicles. These established test methods have been modified to incorporate today's analytical laboratory equipment. The Orbital test objective was to test a wide range of materials to incorporate the revolution in polymer and composite materials that has occurred since the 1960's. Testing is accomplished in 3 stages from rough screening to detailed analytical tests. Several interesting test observations have been made during this testing and are included in the paper. A summary of the set-up, test and evaluation of long-term storage sub-scale tanks is also included. This sub-scale tank test lasted for a 7-month duration prior to being stopped due to a polar boss material breakdown. Chemical evaluations of the hydrogen peroxide and residue left on the polar boss surface identify the material breakdown quite clearly. The paper concludes with recommendations for future testing and a specific effort underway within the industry to standardize the test methods used in evaluating materials.

Boxwell, R.↗

Assessment of The Compatibility of Composite Materials With High-Test Hydrogen Peroxide

The compatibility of composite materials with high-test hydrogen peroxide (HTP) was assessed using various chemical and mechanical techniques. Methods included classical schemes combining concentration assay with accelerated aging by means of a heated water bath. Exothermic reactivity was observed using Isothermal Microcalorimetry. Mechanical Properties testing determined degradation of the composite material. Photoacoustic Infrared Spectroscopy was used to monitor chemical alteration of the resin matrix. Other materials were examined including some polymers and metals.

Gostowski, Rudy↗

Further Studies of Materials Compatibility in High-Test Hydrogen Peroxide

Assessment of the compatibility of high-test hydrogen peroxide (HTP) with materials, in particular new materials such as composites, is critical to the development of new propulsion systems meeting requirements of reduced cost and environmental impact. While compatibility with HTP has been addressed previously, newer materials were not considered. The focus of this project was to develop a scheme for evaluation of HTP with all materials. In the previous summer, methods were developed for production of HTP on site, and preliminary steps were taken to evaluate materials. Methods investigated this summer have included accelerated aging by heating, coupled with assay of concentration and stabilization loss, observation of reactivity by means of Isothermal Microcalorimetry, and evaluation of changes to the materials by Short Beam Shear testing and by Photoacoustic-Fourier Transform Infrared Spectroscopy. Various metals, polymers, and composites were examined in this study.

Gostowski, R.↗

The Effects of Long-Term Feeding of Rodent Food Bars on Lipid Peroxidation And Antioxidant Enzyme Levels In Fisher Rats

A specialized rodent food bar diet has been developed and utilized successfully for short-duration shuttle missions. Recent tests conducted in preparation for experiments aboard the International Space Station (ISS) indicated that long-term food bar feeding for three months induced hyperlipidemia in rats. This study examined oxidative stress status in livers of these same animals. Spectrophotometric analysis of 79 Fischer rat livers (40 female and 39 male) for lipid peroxidation (LPO) and superoxide dismutase (SOD) was conducted using Bioxytech LPO-587(TM) assay kit and SOD-525(Tm) assay kit, respectively. The treatment groups consisted of 20 male CHOW and 19 male FOOD BAR rats and 20 female CHOW and 20 female FOOD BAR rats. Statistical analysis to compare differences between groups was performed by standard analysis of variance procedures. The male FOOD BAR group LPO mean (3.6 +/- 0.2 mmol/g) was significantly (p less than or equal to 0.05) greater than that of the male CHOW group (2.1 +/-0.1 mmol/g). Moreover the female FOOD BAR group LPO mean (2.9 +/-0.1 mmol/g) was also significantly greater than the female CHOW group mean (2.2 +/-0.1 mmol/g). The mean values for SOD in both male and female groups showed no significant differences between CHOW and FOOD BAR groups. These results show that LPO levels were significantly higher in both the male and female FOOD BAR groups compared to CHOW groups and that there was no concomitant increase in SOD levels across the group. In addition, males showed a greater difference than females in terms of LPO levels. These findings suggest a need for further investigation into the use of the current food bar formulation for long-term experiments such as those planned for the ISS.

Ramirez, Joel↗

NASA Hydrogen Peroxide Propulsion Perspective

This presentation is to provide the current status of NASA's efforts in the development of hydrogen peroxide in both mono-propellant and bi-propellant applications, consistent with the Space Launch Initiative goals of pursuing low toxicity and operationally simpler propellants for application in the architectures being considered for the 2nd Generation Reusable Launch Vehicle, also known as the Space Launch Initiative, or SLI.

Unger, Ronald↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High-Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (equal to or greater than 70%) offers many advantages in space launch applications. However, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to % Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

An Experimental Investigation of Hypergolic Ignition Delay of Hydrogen Peroxide with Fuel Mixtures

An experimental investigation of hypergolicity and ignition delay of fuel mixtures with hydrogen peroxide is presented. Example results of high speed photography and schleiren from drop tests are shown. Also, a discussion of the sensitivity to experimental parameters such as drop size and subsequent uncertainty considerations of ignition delay results is presented. It is shown that using the described setup on the mixtures presented, the precision uncertainty is on the order of 6% of average ignition delay and 5% of average decomposition delay. This represents sufficient repeatability for first order discrimination of ignition delay for propellant development and screening. Two mixtures, each using commonly available amines and transition metal compounds, are presented as examples that result in ignition delays on the order of 10 milliseconds.

Blevins, John A.↗

Distribution of Hydrogen Peroxide, Carbon Dioxide, and Sulfuric Acid in Europa's Icy Crust

Galileo's Near Infrared Mapping Spectrometer (NIMS) detected hydrogen peroxide, carbon dioxide and a hydrated material on Europa's surface, the latter interpreted as hydrated sulfuric acid (H2SO4*nH2O) or hydrated salts. Related compounds are molecular oxygen, sulfur dioxide, and two chromophores, one that is dark in the ultraviolet(UV) and concentrated on the trailing side, the other brighter in the UV and preferentially distributed in the leading hemisphere. The UV-dark material has been suggested to be sulfur.

Carlson, R. W.↗

High Strength and Compatible Aluminum Alloy for Hydrogen-Peroxide Fuel Tanks

This paper describes the development of a new high strength and Hydrogen Peroxide (HP) propellant compatible aluminum alloy for NASA Hyper-X vehicle's fuel tanks and structures. The tensile strength of the new alloy is more than 3 times stronger than the conventional 5254 alloy while it still maintains HP compatibility similar to 5254 (Class 1 category). The alloy development strategy consists of selecting certain rare earth and transition metals, with unique electrochemical properties, that will not act as catalysts to decompose liquid HP at the atomic level. Such elements will added to the aluminum alloy and the mixture will be cast and rolled into thin sheet metals. Test coupons are machined from sheet metals for HP long-term exposure testing and mechanical properties testing. In addition, the ability to weld the new alloy using Friction Stir Welding has also been explored. Currently, aluminum alloy 5254 is the state-of-the-art material for HP storage, but its yield strength is very low (420 ksi) and may not be suitable for the development of light-weight fuel tanks for Hyper-X vehicles. The new high strength and HP compatible alloy could represent an enabling material technology for NASA's Hyper-X vehicles, where flight weight reduction is a critical requirement. These X-planes are currently under studied as air-breathing hypersonic research vehicles featuring a lifting body configuration with a Rocket Based Combined Cycle (RBCC) engine system.

Lee, Jonathan A.↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (greater than or equal to 70%) offers many advantages in space launch applications; however, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to %Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

The chemical activities of the Viking biology experiments and the arguments for the presence of superoxides, peroxides, gamma-Fe2O3 and carbon suboxide polymer in the Martian soil

The evolution of N2, Ar, O2, and CO2 from Martian soil as a function of humidity in the Gas Exchange Experiment are correlated with the mean level of water vapor in the Martian atmosphere. All but O2 are associated with desorption. The evolution of oxygen is consistent with the presence of alkaline earth and alkali metal superoxides; and their peroxides and the gamma-Fe2O3 in the soil can account for the generation of radioactive gas in the Labeled Release Experiment. The slower evolution of CO2 from both the Gas Exchange Experiment and the Labeled Release Experiment are associated with the direct oxidation of organics by gamma-Fe2O3. The Pyrolytic Release Experiment's second peak may be carbon suboxide as demonstrated by laboratory experiments. A necessary condition is that the polymer exists in the Martian soil. We ascribe the activity of the surface samples to the reaction of Martian particulates with an anhydrous CO2 atmosphere activated by uv and ionizing radiations. The surface particles are ultimately altered by exposure to small but significant amounts of water at the sites. From the working model, we have predicted the peculiar nature of the chemical entities and demonstrated that the model is justified by laboratory data. The final confirmation of this model will entail a return to Mars, but the nature and implications of this chemistry for the Martian surface is predicted to reveal even more about Mars with further simulations in the laboratory.

long duration↗

Hydrogen peroxide homeostasis: activation of plant catalase by calcium/calmodulin

Environmental stimuli such as UV, pathogen attack, and gravity can induce rapid changes in hydrogen peroxide (H(2)O(2)) levels, leading to a variety of physiological responses in plants. Catalase, which is involved in the degradation of H(2)O(2) into water and oxygen, is the major H(2)O(2)-scavenging enzyme in all aerobic organisms. A close interaction exists between intracellular H(2)O(2) and cytosolic calcium in response to biotic and abiotic stresses. Studies indicate that an increase in cytosolic calcium boosts the generation of H(2)O(2). Here we report that calmodulin (CaM), a ubiquitous calcium-binding protein, binds to and activates some plant catalases in the presence of calcium, but calcium/CaM does not have any effect on bacterial, fungal, bovine, or human catalase. These results document that calcium/CaM can down-regulate H(2)O(2) levels in plants by stimulating the catalytic activity of plant catalase. Furthermore, these results provide evidence indicating that calcium has dual functions in regulating H(2)O(2) homeostasis, which in turn influences redox signaling in response to environmental signals in plants.

NASA Discipline Plant Biology↗

Aluminum-Scandium Alloys: Material Characterization, Friction Stir Welding, and Compatibility With Hydrogen Peroxide (MSFC Center Director's Discretionary Fund Final Report, Proj. No. 04-14)

This Technical Memorandum describes the development of several high-strength aluminum (Al) alloys that are compatible with hydrogen peroxide (H2O2) propellant for NASA Hypersonic-X (Hyper-X) vehicles fuel tanks and structures. The yield strengths for some of these Al-magnesium-based alloys are more than 3 times stronger than the conventional 5254-H112 Al alloy, while maintaining excellent H2O2 compatibility similar to class 1 5254 alloy. The alloy development strategy is to add scandium, zirconium, and other transitional metals with unique electrochemical properties, which will not act as catalysts, to decompose the highly concentrated 90 percent H2O2. Test coupons are machined from sheet metals for H2O2 long-term exposure testing and mechanical properties testing. In addition, the ability to weld the new alloys using friction stir welding has also been explored. The new high-strength alloys could represent an enabling material technology for Hyper-X vehicles, where flight weight reduction is a critical requirement.

Lee, J. A.↗

Design and assembly of a catalyst bed gas generator for the catalytic decomposition of high concentration hydrogen peroxide propellants and the catalytic combustion of hydrocarbon/air mixtures

A method for designing and assembling a high performance catalyst bed gas generator for use in decomposing propellants, particularly hydrogen peroxide propellants, for use in target, space, and on-orbit propulsion systems and low-emission terrestrial power and gas generation. The gas generator utilizes a sectioned catalyst bed system, and incorporates a robust, high temperature mixed metal oxide catalyst. The gas generator requires no special preheat apparatus or special sequencing to meet start-up requirements, enabling a fast overall response time. The high performance catalyst bed gas generator system has consistently demonstrated high decomposition efficiency, extremely low decomposition roughness, and long operating life on multiple test articles.

Lohner, Kevin A.↗

Safe, in situ methodologies for the destruction of triacetone triperoxide and other explosive peroxides

Triacetone triperoxide (TATP) and other explosives of the peroxide family are safely degraded in situ. Nano and micron size metal particles in an elemental state include pure iron and magnesium or iron and magnesium particles that are mechanically alloyed with palladium and nickel. The metal particles are used in both the elemental state and in emulsions that are made from water, a hydrophobic solvent, such as corn oil, and a food-grade nonionic surfactant. The neat metals and emulsified zero valent metals (EZVM) safely degrade TATP with the major degradation product being acetone. The EZVM system absorbs and dissolves the TATP into the emulsion droplets where TATP degradation occurs. EZVM systems are ideal for degrading dry TATP crystals that may be present on a carpet or door entrance. Both the neat metal system and the emulsion system (EZVM) degrade TATP in an aqueous slurry.

Clausen, III, Christian↗

On the Formation of Interstellar Water Ice: Constraints from a Search for Hydrogen Peroxide Ice in Molecular Clouds

Recent surface chemistry experiments have shown that the hydrogenation of molecular oxygen on interstellar dust grains is a plausible formation mechanism, via hydrogen peroxide (H2O2), for the production of water (H2O) ice mantles in the dense interstellar medium. Theoretical chemistry models also predict the formation of a significant abundance of H2O2 ice in grain mantles by this route. At their upper limits, the predicted and experimental abundances are sufficiently high that H2O2 should be detectable in molecular cloud ice spectra. To investigate this further, laboratory spectra have been obtained for H2O2/H2O ice films between 2.5 and 200 micron, from 10 to 180 K, containing 3%, 30%, and 97% H2O2 ice. Integrated absorbances for all the absorption features in low-temperature H2O2 ice have been derived from these spectra. For identifying H2O2 ice, the key results are the presence of unique features near 3.5, 7.0, and 11.3 micron. Comparing the laboratory spectra with the spectra of a group of 24 protostars and field stars, all of which have strong H2O ice absorption bands, no absorption features are found that can definitely be identified with H2O2 ice. In the absence of definite H2O2 features, the H2O2 abundance is constrained by its possible contribution to the weak absorption feature near 3.47 micron found on the long-wavelength wing of the 3 micron H2O ice band. This gives an average upper limit for H2O2, as a percentage of H2O, of 9% +/- 4%. This is a strong constraint on parameters for surface chemistry experiments and dense cloud chemistry models.

Smith, R. G.↗

Hydrogen Peroxide-Water-Ethanol-Monopropellant Blend for CubeSat Propulsion

Monopropellant propulsion that provides high performance and low hazards compared to state-of-art hydrazine are being investigated under NASA, DOD and commercially sponsored green propellant research and development programs. This NASAeffort looks at phosphate stabilized 50% hydrogen peroxide/water –ethanol blends to evaluate their stability and combustion behavior in submillimeter diameter microtube combustion apparatus for cubesat propulsion applications. Exploratory 7-day stabilitytests find no pressure rise in a sealed test tube environment at room temperature indicating at least short term stability of the mixture. Temperature rise during combustion testing in resistively heated nickel microtube apparatus shows that micro-combustion is achieved in the tube. Propellant density is approximately 1.2 g/cm3compared to 1.0 g/cm3for hydrazine. Theoretical specific impulse of the stoichiometric blend is 219 s at a chamber pressure of 20 psia and an area ratio of 30:1. Density-specific impulseof this blendis263 swhile hydrazine is only about 215-220 sin small reaction control system thrusters. This provides about 20-22% more density-specific impulse for the cubesat compared to hydrazine. The theoreticalcombustion temperature is2168°F, whichis thermally compatible with stainless steel materials of constructionand the nickel catalystused in the tests. Combustion test results are given for stoichiometric, as well as fuel-leanand fuel-richpropellant formulations. Thesetests focus on thermally and catalytically supported combustionin the microtube, whichrequires a microtube preheat temperature of about 900°F and sufficient residence time to achieve combustion that is stable and anchored in the tubewithout blowing through the tube unreacted. Thrust class is expected to be in the 10 mN range based on flow rate and estimated specific impulse.Power requirements are generally below 25 Wto heat the tube. Steady state combustion testing is typically conducted for 3 minutes and shows littledegradation of the hardware over multiple test cyclesindicating thatthere is little catalyst degradation over time and littlecatalyst deactivation due tothe phosphate stabilizer inthe hydrogen peroxide.

Monopropellant↗

Hydrogen Peroxide-Water-Ethanol Monopropellant Blend for CubeSat Propulsion

Monopropellant propulsion that provides high performance and low hazards compared to state-of-art hydrazine are being investigated under NASA, DOD and commercially sponsored green propellant research and development programs. This NASA effort looks at phosphate stabilized 50% hydrogen peroxide/water –ethanol blends to evaluate their stability and combustion behavior in submillimeter diameter microtube combustion apparatus for cubesat propulsion applications. Exploratory 7-day stability tests find no pressure rise in a sealed test tube environment at room temperature indicating at least short term stability of the mixture. Temperature rise during combustion testing in resistively heated nickel microtube apparatus shows that micro-combustion is achieved in the tube. Propellant density is approximately 1.2 g/cu.cm compared to 1.0 g/cu.cm for hydrazine. Theoretical specific impulse of the stoichiometric blend is 219 s at a chamber pressure of 20 psia and an area ratio of 30:1. Density-specific impulse of this blend is 263 s while hydrazine is only about 215-220 s in small reaction control system thrusters. This provides about 20-22% more density-specific impulse for the cube sat compared to hydrazine. The the oretical combustion temperature is 2168°F, which is thermally compatible with stainless steel materials of construction and the nickel catalyst used in the tests. Combustion test results are given for stoichiometric, as well as fuel-lean and fuel-rich propellant formulations. These tests focus on thermally and catalytically supported combustion in the microtube, which requires a microtube preheat temperature of about 900°F and sufficient residence time to achieve combustion that is stable and anchored in the tube without blowing through the tube unreacted. Thrust class is expected to be in the 10 m N range based on flow rate and estimated specific impulse. Power requirements are generally below 25 W to heat the tube. Steady state combustion testing is typically conducted for 3 minutes and shows little degradation of the hardware over multiple test cycles indicating that there is little catalyst degradation over time and little catalyst deactivation due to the phosphate stabilizer in the hydrogen peroxide.

Monopropellant↗