Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE CHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High-Fidelity Arc-Discharge Model for Hydrogen-Plasma-Smelting-Reduction of Iron Ore

Electrification and use of renewable hydrogen is currently a necessity for decarbonizing the iron-and-steel industry. In this regard, hydrogen plasma smelting reduction (HPSR) is a novel pathway that is being explored for reduction of iron ore. HPSR provides several decarbonization merits compared to conventional blast furnaces. Firstly, the use of renewable hydrogen drastically reduces the CO2 emissions compared to the use of coke. Secondly, renewable electricity in the form of a thermal plasma for making reactive hydrogen species (radicals, ions) are more efficient at reducing iron ore compared to neutral H2. Thirdly, a molten product compatible with downstream processes is obtained from the intense heat transfer from the plasma. However, the scale-up of this technology requires fundamental exploration of hydrogen plasma dynamics and its interaction with complex solid material that include phase changing iron-ore and slag. In this work, we present a first principles continuum scale model for thermal plasmas in Ar/H2 gas mixtures typically used for HPSR. The thermal plasma governing equations for mass, momentum and energy with Lorentz force and Joule heating source terms are solved along with electromagnetic equations for electrostatic and magnetic vector potential. Our solver will be based on Pele, a suite of reacting flow solvers designed for advanced scientific computing architectures (Henry De Frahan et al., Proceedings of SIAM Parallel Processing, 13-25, 2024), and will utilize adaptive mesh generation for enhanced resolutions at locations of intense physicochemical interactions. This study will present the impact of Ar to H2 ratios on excited/dissociated hydrogen species concentrations, plasma temperature and conductivity along with the impact of outgassed species (water, metal vapor, O, OH radicals) from ore surface on gas phase chemistry. Furthermore, the heat and species flux to the surface will be quantified as a function of applied voltages in a transferred arc configuration.

hydrogen plasma↗

Fragile-to-strong transition in liquid As 2 S 3 under pressure: The effect of melt metallization

The well-known classification of glass-forming melts into fragile and strong liquids has several notable exceptions, including water, silica, and certain phase-change materials (PCMs). These exceptional fluid systems exhibit a fragile-to-strong transition (FST) upon cooling: a transformation from a high-temperature liquid with fast atomic dynamics, low viscosity, and low flow activation energy, to a viscous supercooled melt with high energy barriers near the glass transition temperature T g . This behavior is critically important for non-volatile memories, photonic tensor cores, reconfigurable metamaterials, and other devices, that use PCMs, enabling nanosecond-scale crystallization in the fragile regime and long data retention in the strong regime near or below T g . A significant structural transformation is expected between these two viscosity regimes, along with a semiconductor-metal (SC-M) transition upon heating, driven by high internal pressure and associated density increase. By applying high external pressure to the canonical low-conducting chalcogenide melt As 2 S 3 , we observed both the FST and the SC-M transition, occurring simultaneously within the same domain of the P, T−phase space. These findings suggest that the FST is not limited to a few exceptional liquids but is a common phenomenon, at least in systems that exhibit melt metallization within specific regions of their P, T−phase diagrams.

first-principles molecular dynamics↗

Charge-induced atomic strain as a predictor of structural phase transformation in rare-earth intermetallics

We present a descriptor based on charge-induced atomic strain in crystalline lattices for predicting structural phase transformations in rare-earth intermetallic compounds containing lanthanides and transition metals. The charge-induced local atomic strain was obtained from structural optimization of experimentally known crystalline phases using state of the art density-functional theory methods. The predictive power of the descriptor was evaluated on 𝑅⁢𝐸 2 ⁢In (𝑅𝐸 = rare earth) compounds, a class known for diverse phase transformations. We show that incorporating quantum-mechanical effects—such as local charge distribution, bonding, symmetry, and electronic structure—enhances the robustness of the descriptor. To gain further insight, we analyzed phononic and electronic behavior in Y 2 ⁢In and demonstrated that experimental phase transformations are captured only when atomic strain effects are included. The descriptor was further used to predict structural phase changes in (Y⁢b 1–𝑥 ⁢E⁢r 𝑥 ) 2 ⁢In and G⁡d 2 ⁡(I⁢n 1–𝑥⁢ A⁢l 𝑥 ), with predictions confirmed by x-ray powder diffraction. Here, while the current study is focused on lanthanide-based intermetallics, the underlying principles of the descriptor suggest potential applicability to other closely related classes of rare-earth intermetallics.

Density functional theory↗

Novel thermal energy storage component: Development, performance, and phase transition diagnosis

Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.↗

Tailoring a 3D Covalent Organic Framework Toward Facile Functionalization

Three-dimensional covalent organic frameworks (3D COFs) are notably crystalline and stable, but their architectures and monomer structures make them difficult to functionalize. Here, a new strategy is presented to render COF-300 and other imine-linked frameworks amenable to facile functionalization in the last step of synthesis. By reducing the imine linkages to secondary amines and appending them with acetyl halide groups, the linkages are converted to electrophiles that can be readily reacted with nucleophilic guests. This route yields eight new COF-300 derivatives, bearing chloroacetyl, bromoacetyl, azide, cyano, amino, hydroxyl, methoxy, or thiomethyl groups appended to the inter-monomer linkages. The new materials are characterized through solid-state NMR, infrared spectroscopy, and powder X-ray diffraction, among other techniques, finding that the reported linkage transformations proceed to complete conversion while retaining the crystallinity of the materials. Microcrystal electron diffraction (microED) data are used to solve the evacuated structure of the amine-linked framework COF-300-AR for the first time, providing conclusive evidence of this framework's guest-induced phase change, along with the structure of the new framework COF-300-NH 2 . Finally, COF-300-NH 2 is shown to have significantly improved adsorption capacity for CO 2 and perfluoroalkyl substances (PFAS), highlighting the benefits of this synthetic strategy for the generation of customized adsorbents.

COF-300↗

Probing the CP structure of the top quark Yukawa at the future muon collider

We study the top-Higgs coupling with a CP violating phase ξ at a future multi-TeV muon collider. We focus on processes that are directly sensitive to the top quark Yukawa coupling: $t$$\overline{t}$$h$, $tbhμν$, and $t$$\overline{t}$$h$$v$$\overline{v}$ with $h$ → $b$$\overline{b}$ and semileptonic top decays. At different energies, different processes dominate the cross section, providing complementary information. At and above an energy of $\mathcal{O}$(10) TeV, vector boson fusion processes dominate. As we show, in the Standard Model there is destructive interference in the vector boson fusion processes $t$$\overline{t}$$h$$v$$\overline{v}$ and $tbhμν$ between the top quark Yukawa and Higgs-gauge boson couplings. A CP-violating phase changes this interference, and the cross section measurement is very sensitive to the size of the CP-violating angle. Although we find that the cross sections are measured to $\mathcal{O}$(50%) statistical uncertainty at 1σ, a 10 and 30 TeV muon collider can bound the CP-violating angle |ξ| ≲ 9.0° and |ξ| ≲ 5.4°, respectively. However, cross section measurements are insensitive to the sign of the CP-violating angle. To determine that the coupling is truly CP violating, observables sensitive to CP-violation must be measured. We find in the $t$$\overline{t}$$h$ process the azimuthal angle between the $t$ + $\overline{t}$ plane and the initial state muon+Higgs plane shows good discrimination for ξ = ±0.1π.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Transforming nanoscale VO 2 (B) into a scalable sodium-ion electrode

The intermittent nature of renewable energies requires highly reliable grid-level energy storage approaches. A critical consideration in developing this technology is the areal capacity which determines battery performance and influences the cost of battery technology. Of related importance is finding new ways of developing scalable electrodes. In recent years, three-dimensional (3D) printing of conductive scaffolds has emerged as an alternative to overcome the scalability limitations of commercial tape cast electrodes. The research carried out in the current study demonstrates a successful scalability pathway for nanoscale VO 2 (B), a desirable cathode for sodium-ion batteries which has a nano-flower morphology with a crystallite size < 20 nm. By electrodepositing VO 2 (B) onto a graphene aerogel scaffold, we were able to achieve mass loading of over 100 mg·cm −2 and still possess an areal capacity of 10 mAh·cm −2 at a current density of 5 mA·cm −2 . Moreover, after 1000 cycles, these electrodes retained 75% to 80% of their initial capacity. Even at high loading levels, the electrodeposited VO 2 (B) exhibits pseudocapacitive material signatures such as a box-like voltammetry response, linear galvanostatic response, and no phase change upon lithiation. The scalability of the VO 2 (B) electrode is demonstrated in a series of experiments which show the areal capacity to scale upon increase in both mass loading and electrode thickness, with only small changes in specific capacity. Furthermore, this study establishes that nanoscale materials can be scaled up to achieve thick electrodes without compromising their electrochemical properties.

additive manufacturing↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Biphasic solvents for post-combustion CO 2 capture from natural gas flue Gas

Fossil fuel fired power plants are generally expected to remain one of the most significant global sources of electricity for decades to come. Consequently, carbon management technologies are needed to reduce or eliminate ongoing emissions from these sources. Amongst the many techniques for carbon capture, aqueous amine-based absorbents (monoethanolamine, MEA, in particular) are, presently, considered the leading technology for post-combustion CO 2 point-source capture. These technologies are nevertheless limited by their high capital and regeneration energy costs. Biphasic solvents have been identified as an attractive alternative to traditional MEA based absorbents due to their potential energy savings. Thus far, however, the research on biphasic solvents has largely focused on their performance in coal flue gas while more dilute natural gas flue gas applications have received relatively little attention. Here, this work examines the performances of two novel biphasic solvent blends, diethylenetriamine (DETA) and triethylenetetramine (TETA), in CO 2 capture from a natural gas flue gas simulant. Across several regeneration tests, both solvents achieved considerable energy savings over the benchmark MEA solution. Specifically, the energy consumption per mol CO 2 recovered for the DETA-based and TETA-based solvents was 46 % and 35 % less than that of the benchmark MEA solution, respectively. Molecular dynamics simulations were also performed to gain a deeper understanding of the phase separation phenomena that occur as a consequence of CO 2 absorption. These simulations indicated that phase change was driven by the strong interaction between the absorption products and water, while the degree of separation depended on the CO 2 loading.

Biphasic solvents↗

Dielectric and magnetic properties of microwave-absorbing FeAl x O y catalysts fabricated via solution combustion synthesis

Iron-based alumina (FeAl x O y ) nanocomposites are microwave-absorbers and catalysts, which makes them promising for emerging microwave-assisted thermocatalytic technologies. Solution combustion synthesis (SCS) has been used to synthesize FeAl x O y powders, and prior work has demonstrated that adjusting SCS parameters significantly changes phase composition and specific surface area of the products. However, it is unclear how synthesis parameters affect their microwave-absorbing properties, which are essential for optimizing microwave-assisted technologies. To address this challenge, in the present work, twelve different FeAl x O y products were synthesized at different combinations of the SCS parameters such as two fuels (citric acid and glycine), two heating modes (hotplate and muffle furnace), and three Fe:Al molar ratios (2:1, 1:1, 1:2). Dielectric and magnetic properties of the products were characterized using a network analyzer and a vibrating sample magnetometer. Based on the measured permittivity and permeability, penetration depth and reflection loss were calculated as a function of frequency and bed thickness. The products were heated by microwaves at 2.45 GHz and then examined with X-ray diffraction (XRD) analysis. For all products, the magnetic saturation was lower than for bulk iron oxides because of the small crystallite size and aluminum substitution. The use of glycine induced high dielectric losses and enabled fast microwave-heating rates compared to citric acid. Higher Fe:Al ratio also led to higher dielectric and magnetic losses. With glycine fuel, SCS in a furnace induced larger penetration depth and lower microwave absorption than SCS on a hotplate. The minimization of reflected power was more sensitive to the thickness of the product bed than to the frequency of the electromagnetic field. Post-heating XRD analysis revealed different phase transformations in the FeAl x O y powders depending on the SCS parameters. As a result, an FeAl x O y material, synthesized via incipient wetness impregnation, lacked magnetic losses and did not heat well as compared to the SCS products.

Combustion synthesis↗

MFC 5.0: An exascale many-physics flow solver

Many problems of interest in engineering, medicine, and the fundamental sciences rely on high-fidelity flow simulation, making performant computational fluid dynamics solvers a mainstay of the open-source software community. Previous work MFC 3.0 was made a published, documented, and open-source solver via Bryngelson et al. Comp. Phys. Comm. (2021) with numerous physical features, numerical methods, and scalable infrastructure. MFC 5.0 is a significant update to MFC 3.0, featuring a broad set of well-established and novel physical models and numerical methods, as well as the introduction of GPU and APU (or superchip) acceleration. Here, we exhibit state-of-the-art performance and ideal scaling on the first two exascale supercomputers, OLCF Frontier and LLNL El Capitan. Combined with MFC’s single-accelerator performance, MFC achieves exascale computation in practice, and achieved the largest-to-date public CFD simulation at 200 trillion grid points as a 2025 ACM Gordon Bell Prize finalist. New physical features include the immersed boundary method, N-fluid phase change, Euler–Euler and Euler–Lagrange sub-grid bubble models, fluid-structure interaction, hypo- and hyper-elastic materials, chemically reacting flow, two-material surface tension, magnetohydrodynamics (MHD), and more. Numerical techniques now represent the current state-of-the-art, including general relaxation characteristic boundary conditions, WENO variants, Strang splitting for stiff sub-grid flow features, and low Mach number treatments. Weak scaling to tens of thousands of GPUs on OLCF Summit and Frontier and LLNL El Capitan achieves efficiencies within 5% of ideal to over 90% of their respective system sizes. Strong scaling results for a 16-times increase in device count show parallel efficiencies over 90% on OLCF Frontier. MFC’s software stack has undergone further improvements, including continuous integration, which ensures code resilience and correctness through over 300 regression tests; metaprogramming, which reduces code length while maintaining performance portability; and code generation for computing chemical reactions

Computational fluid dynamics↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗