At least 145 records · Page 8

A source of hard X-ray radiation based on hybrid X pinches

X pinches are well known to produce very small, dense plasma pinches (“hot spots”) that emit sub-nanosecond bursts of 1–8 keV radiation. Hard X-ray radiation in the range from 8 to 300 keV or more is also emitted, and only a small portion of which is associated with the X-pinch hot spot. In hybrid X-pinches (HXP), the 10 ns hard X-ray pulse is terminated by fast closure of the gap between the two conical electrodes of the HXP by rapidly expanding electrode plasmas. The temporal, spectral, and spatial properties of this higher energy radiation have been studied. This radiation was used for point-projection imaging with magnification between 1.5 and 6, and spatial resolution of 20–100 μ m was demonstrated..

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on a negative hydrogen ion source with hot cathode arc discharge

A negative hydrogen (H{sup −}) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H{sup −} beam with ε {sub N,} {sub RMS} = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I{sub e{sup −}}/I{sub H{sup −}} were experimentally studied. The discussion on the result, and opinions to improve the source were given.

43 PARTICLE ACCELERATORS↗

Rod-filter-field optimization of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second-stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). Although rod-filter-field (RFF) is indispensable and one of the most beam performance dominative parameters for the RF-driven H{sup −} ion source with the internal-antenna, the procedure to optimize it is not established. In order to optimize the RFF and establish the procedure, the beam performances of the J-PARC source with various types of rod-filter-magnets (RFMs) were measured. By changing RFM’s gap length and gap number inside of the region projecting the antenna inner-diameter along the beam axis, the dependence of the H{sup −} ion beam intensity on the net 2MHz-RF power was optimized. Furthermore, the fine-tuning of RFM’s cross-section (magnetmotive force) was indispensable for easy operation with the temperature (T{sub PE}) of the plasma electrode (PE) lower than 70°C, which minimizes the transverse emittances. The 5% reduction of RFM’s cross-section decreased the time-constant to recover the cesium effects after an slightly excessive cesiation on the PE from several 10 minutes to several minutes for T{sub PE} around 60°C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Permanent-Magnet Microwave Ion Source for a Sealed-Tube Neutron Generator

A microwave ion source has been designed and constructed for use with a sealed-tube, high-yield neutron generator. When operated with a tritium-deuterium gas mixture the generator will be capable of producing 5*1011 n/s in non-proliferation applications. Microwave ion sources are well suited for such a device because they can produce high extracted beam currents with a high atomic fraction at low gas pressures of 0.2-0.3 Pa required for sealed tube operation. The magnetic field strength for achieving electron cyclotron resonance (ECR) condition, 87.5 mT at 2.45 GHz microwave frequency, was generated and shaped with permanent magnets surrounding the plasma chamber and a ferromagnetic plasma electrode. This approach resulted in a compact ion source that matches the neutron generator requirements. The needed proton-equivalent extracted beam current density of 40 mA/cm^2 was obtained at moderate microwave power levels of 400 W. Results on magnetic field design, pressure dependency and atomic fraction measured for different wall materials are presented.

43 PARTICLE ACCELERATORS↗

Numerical Analysis of Electronegative Plasma near the Extraction Grid in Negative Ion Sources

The effects of plasma electrode (PE) bias on the extraction process in a negative ion source are studied with a series of two-dimensional (2D) electrostatic particle simulations. Motion of charged particles in their self-consistent electric field is modeled by the Particle-In-Cell (PIC) method. The effect of a weak transverse magnetic field is also taken into account. Extracted electron current density gradually decreases as the PE bias increases, while the absolute value of PE net current density initially increases and is saturated for higher values of PE bias. The extracted negative ion current density reaches a weak peak when the PE bias approaches the bulk plasma potential (Vpf) in the case without the PE bias, but the decrease afterwards is mild. Physical mechanisms leading to these results are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Open Boundary Conditions for Dissipative MHD

In modeling magnetic confinement, astrophysics, and plasma propulsion, representing the entire physical domain is often difficult or impossible, and artificial, or 'open' boundaries are appropriate. A novel open boundary condition (BC) for dissipative MHD, called Lacuna-based open BC (LOBC), is presented. LOBC, based on the idea of lacuna-based truncation originally presented by V.S. Ryaben'kii and S.V. Tsynkov, provide truncation with low numerical noise and minimal reflections. For hyperbolic systems, characteristic-based BC (CBC) exist for separating the solution into outgoing and incoming parts. In the hyperbolic-parabolic dissipative MHD system, such separation is not possible, and CBC are numerically unstable. LOBC are applied in dissipative MHD test problems including a translating FRC, and coaxial-electrode plasma acceleration. Solution quality is compared to solutions using CBC and zero-normal derivative BC. LOBC are a promising new open BC option for dissipative MHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanism of carbon nanostructure synthesis in arc plasma

Plasma enhanced techniques are widely used for synthesis of carbon nanostructures. The primary focus of this paper is to summarize recent experimental and theoretical advances in understanding of single-wall carbon nanotube (SWNT) synthesis mechanism in arcs, and to describe methods of controlling arc plasma parameters. Fundamental issues related to synthesis of SWNTs, which is a relationship between plasma parameters and SWNT characteristics are considered. It is shown that characteristics of synthesized SWNTs can be altered by varying plasma parameters. Effects of electrical and magnetic fields applied during SWNT synthesis in arc plasma are explored. Magnetic field has a profound effect on the diameter, chirality, and length of a SWNT synthesized in the arc plasma. An average length of SWNT increases by a factor of 2 in discharge with magnetic field and an amount of long nanotubes with the length above 5 {mu}m also increases in comparison with that observed in the discharge without a magnetic field. In addition, synthesis of a few-layer graphene in a magnetic field presence is discovered. A coupled model of plasma-electrode phenomena in atmospheric-pressure anodic arc in helium is described. Calculations indicate that substantial fraction of the current at the cathode is conducted by ions (0.7-0.9 of the total current). It is shown that nonmonotonic behavior of the arc current-voltage characteristic can be reproduced taking into account the experimentally observed dependence of the arc radius on arc current.

36 MATERIALS SCIENCE↗

Achieving Higher Fidelity Pulsed-Power Simulations Using Advanced Gap Closure Modeling

This project has progressed several physics models in the EMPIRE plasma simulation code to achieve higher fidelity simulations of high-current diode operation in pulsed-power accelerators. In this report, we present details for the following major work products: (1) a set of verification problems covering all key processes involved in gap closure physics has been designed; this suite has facilitated feature vetting and overall model maturation, (2) a new EMPIRE exemplar has been developed: the Radiographic Integrated Test Stand 6 (RITS-6) diode, and (3) An exemplar for the Saturn accelerator exemplar was enabled by the models matured under this work to self-consistently simulate further into the diode pulse than previously possible (bipolar flow regime). These developments have lead to the highest confidence EMPIRE power flow predictions of the Saturn accelerator to date. Additionally, three modeling approaches for simulating electrode plasmas have been investigated. We report on these results and provide recommendations.

43 PARTICLE ACCELERATORS↗

Experimental study of self magnetic pinch diode as flash radiography source at 4 megavolt

The Self Magnetic Pinch (SMP) diode is a potential high-brightness X-ray source for high voltage generators (2–10 MV) that has shown good reliability for flash radiography applications [D. D. Hinchelwood et al., “High power self-pinch diode experiments for radiographic applications” IEEE Trans. Plasma Sci. 35(3), 565–572 (2007)]. We have studied this diode at about 4 MV, driven by the ASTERIX generator operated at the CEA/GRAMAT [G. Raboisson et al., “ASTERIX, a high intensity X-ray generator,” in Proceedings of the 7th IEEE Pulsed Power Conference (1989), pp. 567–570]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode is modified in order to set up flash radiographic diodes. A previous set of radiographic experiments was carried out on ASTERIX with a Negative Polarity Rod Pinch (NPRP) diode [B. Etchessahar et al., “Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV,” Phys. Plasmas 19(9), 093104 (2012)]. The SMP diode which is examined in the present study provides an alternative operating point on the same generator and a different radiographic performance: 142 ± 11 rad at 1 m dose (Al) for a 3.46 ± 0.42 mm spot size (1.4× FWHM of the LSF). This performance is obtained in a reproducible and robust nominal configuration. However, several parametric variations were also tested, such as cathode diameter and anode/cathode gap. They showed that an even better performance is accessible after optimization, in particular, a smaller spot size (<3 mm). Numbers of electrical, optical, and X-ray diagnostics have been implemented in order to gain more insight in the diode physics and to optimize it further. For the first time in France, visible and laser imaging of the SMP diode has been realized, from a radial point of view, thus, providing key information on the electrode plasmas evolution, responsible for the gap closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial plasma jet characterization on a microsecond x-pinch

The jets produced on a microsecond x-pinch (quarter period T 1/4 ~ 1 μs, dI/dt ~ 0.35 kA/ns) have been studied through light-field schlieren imaging and optical framing photographs across 4 different materials: Al, Ti, Mo, and W. The axial velocity of the jets was measured and exhibited no dependence on atomic number (Z) of the wire material. Additionally, there may be a dependence on another factor(s), namely, the current rise rate. The average axial jet velocity across all four materials was measured to be 2.9 ± 0.5 × 10 6 cm/s. The average jet diameter and the average radial jet expansion rate displayed inverse relationships with Z, which may be attributed to radiative cooling and inertia. Asymmetry between the anode and cathode jet behavior was observed and is thought to be caused by electron beam activity. The mean divergence angle of the jet was found to vary with wire material and correlated inversely with the thermal conductivity of the cold wire. Optical images indicated a two-layer structure in Al jets which may be caused by standing shocks and resemble phenomena observed in astrophysical jet formation and collimation. Finally, kinks in the jets have also been observed which may be caused by m = 1 MHD instability modes or by the interaction of the jet with the electrode plasma.

36 MATERIALS SCIENCE↗

Enhancement of SPES source performances

Installation of SPES source at LNL was finished in July 2006 and the first beam was extracted in September 2006. Commissioning results confirmed very good performance of the extracted current density. Conversely, source reliability was very poor due to glow-discharge phenomena, which were caused by the ion source axial magnetic field protruding in the high-voltage column. This problem was fixed by changing the stainless steel plasma electrode support with a ferromagnetic one. This new configuration required us to recalculate ion source solenoids positions and fields in order to recover the correct resonance pattern. Details on magnetic simulations and experimental results of high voltage column shielding are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coaxial Mono-Energetic Gamma Generator for Active Interrogation

Compact mono-energetic photon sources are sought for active interrogation systems to detect shielded special nuclear materials in, for example, cargo containers, trucks and other vehicles. A prototype gamma interrogation source has been designed and built that utilizes the {sup 11}B(p,{gamma}){sup 12}C reaction to produce 12 MeV gamma-rays which are near the peak of the photofission cross section. In particular, the {sup 11}B(p,{gamma}){sup 12}C resonance at 163 kV allows the production of gammas at low proton acceleration voltages, thus keeping the design of a gamma generator comparatively small and simple. A coaxial design has been adopted with a toroidal-shaped plasma chamber surrounding a cylindrical gamma production target. The plasma discharge is driven by a 2 MHz rf-power supply (capable up to 50 kW) using a circular rf-antenna. Permanent magnets embedded in the walls of the plasma chamber generate a multi-cusp field that confines the plasma and allows higher plasma densities and lower gas pressures. About 100 proton beamlets are extracted through a slotted plasma electrode towards the target at the center of the device that is at a negative 180 kV. The target consists of LaB{sub 6} tiles that are brazed to a water-cooled cylindrical structure. The generator is designed to operate at 500 Hz with 20 {mu}s long pulses, and a 1% duty factor by pulsing the ion source rf-power. A first-generation coaxial gamma source has been built for low duty factor experiments and testing.

43 PARTICLE ACCELERATORS↗

Studies of extraction and transport system for highly charged ion beam of 18 GHz superconducting electron cyclotron resonance ion source at Research Center for Nuclear Physics

An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

43 PARTICLE ACCELERATORS↗

Extraction of ion beam from laser ion source for direct plasma injection scheme

Laser ion sources are expected to be used in various applications of heavy ion beam technology. The plasma direct injection scheme (DPIS) is a method in which ion beams extracted from a laser ion source are directly injected into a radio frequency quadrupole (RFQ) linear accelerator. In this study, a new shape of the plasma electrode with a concave surface for the DPIS was proposed to inject a converging beam to a cavity of RFQ accelerator. This approach allows the use of a large-diameter extraction electrode, which is not limited by the aperture of the RFQ electrode rods. The DPIS, using the concave surface electrode, was employed to accelerate C 6+ ion beams. The results indicated that both the beam current and the number of ions increased nearly twice with the proposed electrode shape compared to values obtained with the conventional electrode. This enhancement corresponded to the increased extraction area of the beam.

43 PARTICLE ACCELERATORS↗

The smooth transition from field emission to a self-sustained plasma in microscale electrode gaps at atmospheric pressure

We report on the existence of a smooth transition from field emission to a self-sustained plasma in microscale electrode geometries at atmospheric pressure. This behavior, which is not found at macroscopic scales or low pressures, arises from the unique combination of large electric fields that are created in microscale dimensions to produce field-emitted electrons and the high pressures that lead to collisional ionization of the gas. Using a tip-to-plane electrode geometry, currents less than 10 μA are measured at onset voltages of ∼200 V for gaps less than 5 μm, and analysis of the current–voltage (I-V) relationship is found to follow Fowler–Nordheim behavior, confirming field emission. As the applied voltage is increased, gas breakdown occurs smoothly, initially resulting in the formation of a weak, partial-like glow and then a self-sustained glow discharge. Remarkably, this transition is essentially reversible, as no significant hysteresis is observed during forward and reverse voltage sweeps. In contrast, at larger electrode gaps, no field emission current is measured and gas breakdown occurs abruptly at higher voltages of ∼400 V, absent of any smooth transition from the pre-breakdown condition and is characterized only by glow discharge formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory and simulation of anode spots in low pressure plasmas

When electrodes are biased above the plasma potential, electrons accelerated through the associated electron sheath can dramatically increase the ionization rate of neutrals near the electrode surface. It has previously been observed that if the ionization rate is great enough, a double layer separates a luminous high-potential plasma attached to the electrode surface (called an anode spot or fireball) from the bulk plasma. Here, results of the first 2D particle-in-cell simulations of anode spot formation are presented along with a theoretical model describing the formation process. It is found that ionization leads to the build-up of an ion-rich layer adjacent to the electrode, forming a narrow potential well near the electrode surface that traps electrons born from ionization. It is shown that anode spot onset occurs when a quasineutral region is established in the potential well and the density in this region becomes large enough to violate the steady-state Langmuir condition, which is a balance between electron and ion fluxes across the double layer. A model for steady-state properties of the anode spot is also presented, which predicts values for the anode spot size, double layer potential drop, and form of the sheath at the electrode by considering particle, power, and current balance. Furthermore, these predictions are found to be consistent with the presented simulation and previous experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrode configuration for extended plasma confinement

Methods and systems are provided for plasma confinement utilizing various electrode and valve configurations. In one example, a device includes a first electrode positioned to define an outer boundary of an acceleration volume, a second electrode arranged coaxially with respect to the first electrode and positioned to define an inner boundary of the acceleration volume, at least one power supply to drive an electric current along a Z-pinch plasma column between the first second electrodes, and a set of valves to provide gas to the acceleration volume to fuel the Z-pinch plasma column, wherein an electron flow of the electric current is in a first direction from the second electrode to the first electrode. In additional or alternative examples, a shaping part is conductively connected to the second electrode to, in a presence of the gas, cause a gas breakdown of the gas to generate a sheared flow velocity profile.

Meier, Eric T.↗

Arc plasma assisted rotating electrode process for preparation of metal pebbles

Spherical beryllium pebbles of size ranging from 0.2-2 mm are required as neutron multiplying material in solid Test Blanket Module (TBM) of International Thermonuclear Experimental Reactor (ITER). Rotating electrode process (REP) has been identified as a suitable technique for preparation of beryllium pebbles. In REP, arc plasma generated between non-consumable electrode (cathode) and rotating metal electrode (anode) plays a major role for continuous consumption of metal electrode and preparation of spherical metal pebbles. This paper focuses on description of the process, selection of sub-systems for development of REP experimental set up and optimization of arc parameters, such as, cathode geometry, arc current, arc voltage, arc gap and carrier gas flow rate for preparation of required size spherical metal pebbles. Other parameters which affect the pebbles sizes are rotational speed, metal electrode diameter and physical properties of the metal. As beryllium is toxic in nature its surrogate metals such as stainless steel (SS) and Titanium (Ti) were selected to evaluate the performance of the REP equipment. Several experiments were carried out using SS and Ti electrode and process parameters have been optimized for preparation of pebbles of different sizes. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗