Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA FOCUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Study of soft X-ray emission during wire array implosion under plasma focus conditions at the PF-3 facility

Results of measurements of soft X-ray emission with photon energies of <1 keV under conditions of a plasma focus (PF) experiment are presented. The experiments were carried out at the world’s largest PF device—the PF-3 Filippov-type facility (I ⩽ 3 MA, T/4 ≈ 15–20 µs, W{sub 0} ⩽ 3 MJ). X-ray emission from both a discharge in pure neon and with a tungsten wire array placed on the axis of the discharge chamber was detected. The wire array imploded under the action of the electric current intercepted from the plasma current sheath of the PF discharge in neon. The measured soft X-ray powers from a conventional PF discharge in gas and a PF discharge in the presence of a wire array were compared for the first time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a 500-kJ Mather-type plasma focus device

In this article, design of a 500-kJ Mather-type plasma focus device to achieve 10{sup 11} neutrons/shot is reported. One of its important characteristics is the triple-part anode design. The anode is surrounded by an alumina insulator. The second part of the anode is changeable in order to locate cylindrical, conical, or other shapes of pieces mounted on it. This geometry leads to the easier investigation of the neutron and X-ray emissions of the device. The third part of the anode is for changing the materials exposed to different kinds of radiations. The design parameters are considered by semiempirical and empirical formulas and are sketched by Solidworks software. Also, the peak current and neutron yield are estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma focus ion beam fluence and flux-Scaling with stored energy

Measurements on plasma focus ion beams include various advanced techniques producing a variety of data which has yet to produce benchmark numbers [A Bernard et al., J. Mosc. Phys. Soc. 8, 93-170 (1998)]. This present paper uses the Lee Model code [S Lee, http://www.plasmafocus.net (2012)], integrated with experimental measurements to provide the basis for reference numbers and the scaling of deuteron beams versus stored energy E{sub 0}. The ion number fluence (ions m{sup -2}) and energy fluence (J m{sup -2}) computed as 2.4-7.8 Multiplication-Sign 10{sup 20} and 2.2-33 Multiplication-Sign 10{sup 6}, respectively, are found to be independent of E{sub 0} from 0.4 to 486 kJ. Typical inductance machines (33-55 nH) produce 1.2-2 Multiplication-Sign 10{sup 15} ions per kJ carrying 1.3%-4% E{sub 0} at mean ion energy 50-205 keV, dropping to 0.6 Multiplication-Sign 10{sup 15} ions per kJ carrying 0.7% E{sub 0} for the high inductance INTI PF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A source with a 10{sup 13} DT neutron yield on the basis of a spherical plasma focus chamber

Results from preliminary experimental research of neutron emission generated by a spherical plasma focus chamber filled with an equal-component deuterium-tritium mixture are presented. At a maximum current amplitude in the discharge chamber of {approx}1.5 MA, neutron pulses with a full width at half-maximum of 75-80 ns and an integral yield of {approx}1.3 Multiplication-Sign 10{sup 13} DT neutrons have been recorded.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron and high energy deuteron anisotropy investigations in plasma focus device

The anisotropies of neutron and high energy deuteron emissions from the NX2 plasma focus device [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] are studied. The nuclear activation of graphite targets is used to measure the fluences of high energy deuterons in the axial and radial directions. Two bismuth germanate scintillation detectors connected to multichannel analyzer systems are used for the detection of 511 keV gamma rays resulting from positron annihilation in the two targets. In addition, fast neutron activation detectors are employed to measure the axial and radial fluences of fusion neutrons. These detection systems are calibrated using the simulation code MCNPX[L. S. Waters et al., AIP Conf. Proc. 896, 81 (2007)]. Two distinct regimes of neutron and deuteron anisotropies are observed for the NX2 device. For deuterium gas pressures below 10 mbar, the neutron anisotropy increases with increasing pressure, while the overall neutron yield remains low. For gas pressures of 10-14 mbar, the neutron anisotropy is essentially constant, while, with increasing pressure, the neutron yield rises rapidly and the deuteron anisotropy falls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Results Of A 600 Joules Small Plasma Focus Device

Preliminary results of a 600 J (3.7 muF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0+-0.5 mubar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The study of pinch regimes based on radiation-enhanced compression and anomalous resistivity phenomena and their effects on hard x-ray emission in a Mather type dense plasma focus device (SABALAN2)

In this study, by using argon and nitrogen as the filling gases in a Mather type dense plasma focus device at different values of pressure and charging voltage, two different kinds of pinch regimes were observed for each of the gases. The physics of the pinch regimes could be explained by using the two versions of the Lee's computational model which predicted each of the scenarios and clarified their differences between the two gases according to the radiation-enhanced compression and, additionally, predicted the pinch regimes through the anomalous resistivity effect during the pinch time. This was accomplished through the fitting process (simulation) on the current signal. Moreover, the characteristic amplitude and time scales of the anomalous resistances were obtained. The correlations between the features of the plasma current dip and the emitted hard x-ray pulses were observed. The starting time, intensity, duration, and the multiple or single feature of the emitted hard x-ray strongly correlated to the same respective features of the current dip.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of the performance of a very small repetitive plasma focus device in different working conditions

SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D{sub 2} working gases at several discharge voltages and initial pressures are presented and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dense Plasma Focus Z-pinches for High Gradient Particle Acceleration

The final Z-pinch stage of a Dense Plasma Focus (DPF) could be used as a simple, compact, and potentially rugged plasma-based high-gradient accelerator with fields at the 100 MV/m level. In this paper we review previously published experimental beam data that indicate the feasibility of such an DPF-based accelerator, qualitatively discuss the physical acceleration processes in terms of the induced voltages, and as a starting point examine the DPF acceleration potential by numerically applying a self-consistent DPF system model that includes the induced voltage from both macroscopic and instability driven plasma dynamics. Applications to the remote detection of high explosives and a multi-staged acceleration concept are briefly discussed.

43 PARTICLE ACCELERATORS↗

Angular distribution of energetic argon ions emitted by a 90 kJ Filippov-type plasma focus

Characteristics of the energetic argon ions emitted by a 90 kJ Filippov-type plasma focus are studied by employing an array of Faraday cups. The Faraday cups are designed to minimize the secondary electron emission effects on their response. Angular distribution of the ions is measured, and the results indicate a highly anisotropic emission with a dip at the device axis and a local maximum at the angle of 7° with respect to the axis. It has been argued that this kind of anisotropic emission may be related to the surfatron acceleration mechanism and shown that this behavior is independent of the working gas pressure. It has been also demonstrated that this mechanism is responsible for the generation of MeV ions. Measuring the total ion number at different working gas pressures gives an optimum pressure of 0.3 Torr. In addition, the energy spectrum of ions is measured by taking into account of the ambient gas effects on the energy and charge of the ions. The current neutralization effect of electrons trapped in the ion beam as well as the effect of conducting boundaries surrounding the beam, on the detected signals are investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and initial results from a kilojoule level dense plasma focus with hollow anode and cylindrically symmetric gas puff

We have designed and built a Dense Plasma Focus (DPF) Z-pinch device using a kJ-level capacitor bank and a hollow anode, and fueled by a cylindrically symmetric gas puff. Using this device, we have measured peak deuteron beam energies of up to 400 keV at 0.8 kJ capacitor bank energy and pinch lengths of ∼6 mm, indicating accelerating fields greater than 50 MV/m. Neutron yields of on the order of 10{sup 7} per shot were measured during deuterium operation. The cylindrical gas puff system permitted simultaneous operation of DPF with a radiofrequency quadrupole accelerator for beam-into-plasma experiments. This paper describes the machine design, the diagnostic systems, and our first results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and Simulations of Neutron Emission Versus Deuterium Filling Pressure in Plasma Focus Device PF-24

A series of experiments were carried out using the middle energy (dense) plasma focus device PF-24 with deuterium as a working gas under pressure in a range between 2 and 5 mbar for 17 kV of charging voltage. The relationship between these operating deuterium pressures in reference to the total neutron yield (Y{sub n}) was estimated. The 5-phase Lee code was used to simulate the measured discharge current and neutron yield (Y{sub n}) using a phenomenological beam-target neutron generating mechanism, which was incorporated in the model. Comparison of the Y{sub n} versus pressure using fitted model parameters was made at each point of pressure. The good agreement between measured and computed Y{sub n} values was achieved for discharges with lower neutron emission. The measured Y{sub n} (below 2.6 × 10{sup 9} n/discharge—the median value) has been reproducible by the model for 73% of simulated discharges, while above the median value its prediction were incorrect. The kinetic plasma parameters which were measured and computed using the Lee code for different pressures are: the time to a current sheath collapse (t{sub c}), the average axial current sheath velocity (v{sub z}) and the so called velocity factor (RF). Good agreement was found in the whole range of deuterium pressures between the computed and measured results for these kinematic quantities. Presented findings in this work suggest that the character of neutron emission is more complex than it would seem from classical interpretation of neutron production based on a beam-target model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation of the neutron yield anisotropy with the electrical characteristics of a plasma focus discharge

The anisotropy of the yield and energy of neutrons generated in a small-size plasma focus chamber with a total neutron yield of about 4 x 10{sup 9} DD neutrons per shot was investigated experimentally. The neutrons were recorded using scintillation detectors on a 3-m-long flight base. The measurements were performed at the angles 0{sup o} and 90{sup o} with respect to the chamber axis. The maximum neutron energy measured by the time-of-flight method at the angles 0{sup o} and 90{sup o} was found to be 2.8 and 2.5 MeV, respectively. The measured anisotropy of the neutron yield was in the range 1.15-1.88. The integral DD neutron yield of the source was measured using the activation method (by activating silver isotopes). It is found that the neutron yield and the yield anisotropy depend linearly on the discharge current jump {Delta}I at the instant of neutron generation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of insulator sleeve material on the x-ray emission from a plasma focus device

The effect of insulator sleeve material on x-ray emission from a 2.3 kJ Mather type plasma focus device operated in argon-hydrogen mixture is investigated. The time and space resolved x-ray emission characteristics are studied by using a three channel p-i-n diode x-ray spectrometer and a multipinhole camera. The x-ray emission depends on the volumetric ratio of argon-hydrogen mixture as well as the filling pressure and the highest x-ray emission is observed for a volumetric ratio 40% Ar to 60%H{sub 2} at 2.5 mbar filling pressure. The fused silica insulator sleeve produces the highest x-ray emission whereas nonceramic insulator sleeves such as nylon, Perspex, or Teflon does not produce focus or x-rays. The pinhole images of the x-ray emitting zones reveal that the contribution of the Cu K{alpha} line is weak and plasma x-rays are intense. The highest plasma electron temperature is estimated to be 3.3 and 3.6 keV for Pyrex glass and fused silica insulator sleeves, respectively. It is speculated that the higher surface resistivity of fused silica is responsible for enhanced x-ray emission and plasma electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specific features of X-ray generation by plasma focus chambers with deuterium and deuterium–tritium fillings

The process of hard X-ray (HXR) generation in plasma focus (PF) chambers was studied experimentally. The radiation was recorded using scintillation detectors with a high time resolution and thermoluminescent detectors in combination with the method of absorbing filters. Time-resolved analysis of the processes of neutron and X-ray generation in PFs is performed. The spectra of HXR emission from PF chambers with deuterium and deuterium–tritium fillings are determined. In experiments with PF chambers filled with a deuterium–tritium mixture, in addition to the HXR pulse with photon energies of up to 200–300 keV, a γ-ray pulse with photon energies of up to 2.5–3.0 MeV is recorded, and a mechanism of its generation is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Research on anisotropy of fusion-produced protons and neutrons emission from high-current plasma-focus discharges

The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in “sandwiches” of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The “sandwiches” were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A portable pulsed neutron source based on the smallest sealed-type plasma focus device

Development and operation of a portable and compact pulsed neutron source based on sealed-type plasma focus (PF) device are reported. The unit is the smallest sealed-type neutron producing PF device. The effective volume of the PF unit is 33 cm{sup 3} only. A compact size single capacitor (4 {mu}F) is used as the energy driver. A battery based power supply unit is used for charging the capacitor and triggering the spark gap. The PF unit is operated at 10 kV (200 J) and at a deuterium gas filling pressure of 8 mb. The device is operated over a time span of 200 days and the neutron emissions have been observed for 200 shots without changing the gas in between the shots. The maximum yield of this device is 7.8 x 10{sup 4} neutrons/pulse. Beyond 200 shots the yield is below the threshold (1050 neutrons/pulse) of our {sup 3}He detector. The neutron energy is evaluated using time of flight technique and the value is (2.49 {+-} 0.27) MeV. The measured neutron pulse width is (24 {+-} 5) ns. Multishot and long duration operations envisage the potentiality of such portable device for repetitive mode of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗