Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A spectrometer for high-precision ion temperature and velocity measurements in low-temperature plasmas

We have developed a low-cost spectrometer with simple optical design that achieves unprecedented precision measurements of ion temperature (±0.01 eV) and velocity (±20 m/s). A Fabry-Pérot étalon provides the simultaneous high resolving power and high throughput needed for the light levels available in singly ionized helium and argon plasmas. Reducing the systematic uncertainty in the absolute wavelength calibration needed for the specified velocity precision motivates a Bayesian analysis method called Nested Sampling to address the nontrivial uncertainty in the diffraction order. An initial emission measurement of a singly charged stationary argon plasma yields a temperature of 0.339 ± 0.007 eV and a velocity of -3 ± 4 m/s with a systematic uncertainty of 20 m/s.

47 OTHER INSTRUMENTATION↗

Kinetics of metastable atoms and non-Maxwellian electrons in two-temperature plasmas

Numerical and analytical solutions of the electron Boltzmann equation in two-temperature steady-state helium plasma are studied in a broad range of conditions T(a) = 5,000-20,000 K, T(e) = 10,000-20,000 K; N(a) = 10 to the 10th - 10 to the 18th per cu cm. The WKB analytical solution is found to be satisfactory in most situations. The deviation of the electron distribution from Maxwellian and a possibility of raising of the tail of the distribution in presence of sources of fast electrons is also discussed.

Kunc, J. A.↗

Stability of shock waves in high temperature plasmas

The Dyakov-Kontorovich criteria for spontaneous emission of acoustic waves behind shock fronts are investigated for high temperature aluminum and beryllium plasmas. To this end, the Dyakov and critical stability parameters are calculated from Rankine-Hugoniot curves using a more realistic equation of state (EOS). The cold and ionic contributions to the EOS are obtained via scaled binding energy and mean field theory, respectively. A screened hydrogenic model, including l-splitting, is used to calculate the bound electron contribution to the electronic EOS. The free electron EOS is obtained from Fermi-Dirac statistics. Predictions of the model for ionization curves and shock Hugoniot are found to be in excellent agreement with available experimental and theoretical data. It is observed that the electronic EOS has significant effect on the stability of the planar shock front. While the shock is stable for low temperatures and pressures, instability sets in as temperature rises. The basic reason is ionization of electronic shells and consequent increase in electronic specific heat. The temperatures and densities of the unstable region correspond to those where electronic shells get ionized. With the correct modeling of bound electrons, we find that shock instability for Al occurs at a compression ratio {approx}5.4, contrary to the value {approx}3 reported in the literature. Free electrons generated in the ionization process carry energy from the shock front, thereby giving rise to spontaneously emitted waves, which decay the shock front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Temperature Plasma Assisted Kinetics Study of Ethanol

Abstract: Non- equilibrium plasma assisted kinetics of ethanol at 0.5 atm over a temperature range of 523-1203 K were studied at stoichiometric conditions by using a plasma flow reactor (PFR). The effects of plasma chemistry on fuel and its influence on neutral chemistry is decoupled with both experimental and modelling efforts. Enhanced reactivity was observed experimentally in both plasma-assisted oxidation and pyrolysis cases with fuel consumption beginning at temperatures as low as 523 K. Absolute fuel consumption was observed at temperatures nearly 200 K earlier than pure thermal reactions highlighting the effectiveness of non-equilibrium plasma to promote reactivity. Modelling results illustrated the effect of electron impact reactions towards accelerating fuel consumption and promoting low temperature chemistry by generating excited state N2 and reactive O and OH radicals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of the background plasma temperature on the current filamentation instability

The effects of thermal anisotropy of background plasma on the current-filamentation instability (CFI) in an asymmetric counterstreaming system are investigated with a fully relativistic kinetic model. It is found that both the temperature and the thermal anisotropy of the background plasma play important roles in the development of the CFI. It is also pointed out that the thermal anisotropy of the background plasma dominates over the space charge effect in suppressing the CFI. A parametric study of the CFI is presented in the context of fast ignition. A new way to suppress CFI and its detrimental effects on the fast electron beam divergence has been proposed. The results of the analytical estimations are verified by 2D3V particle-in-cell simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of plasma temperature and density using laser absorption

A laser radiation absorption technique, suitable for temporal measurement of the electron density, the temperature, or a simultaneous determination of both, in an LTE plasma, is discussed. The theoretical calculation of the absorption coefficient for a hydrogen plasma is outlined; some results are presented for visible wavelengths. Measurements of electron density and temperature are presented and shown to be in good agreement with those values obtained by other methods. Finally, the possible use of the argon ion laser for simultaneous electron density and temperature measurement is discussed, and the theoretical curves necessary for its application to hydrogen plasma diagnostics are shown.

Billman, K. W.↗

Plasma temperature clamping in filamentation laser induced breakdown spectroscopy

Ultrafast laser filament induced breakdown spectroscopy is a very promising method for remote material detection. We present characteristics of plasmas generated in a metal target by laser filaments in air. Our measurements show that the temperature of the ablation plasma is clamped along the filamentation channel due to intensity clamping in a filament. Nevertheless, significant changes in radiation intensity are noticeable, and this is essentially due to variation in the number density of emitting atoms. The present results also partly explains the reason for the occurrence of atomic plume during fs LIBS in air compared to long-pulse ns LIBS.

2D fast imaging↗

Low temperature plasma biomedicine: A tutorial review

Gas discharge plasmas formed at atmospheric pressure and near room temperature have recently been shown to be potentially useful for surface and wound sterilization, antisepsis, bleeding cessation, wound healing, and cancer treatment, among other biomedical applications. This tutorial review summarizes the field, stressing the likely role of reactive oxygen and nitrogen species created in these plasmas as the biologically and therapeutically active agents. Reactive species, including radicals and non-radical compounds, are generated naturally within the body and are now understood to be essential for normal biological functions. These species are known to be active agents in existing therapies for wound healing, infection control, and cancer treatment. But they are also observed at elevated levels in persons with many diseases and are associated with aging. The physical and chemical complexity of plasma medical devices and their associated biochemical effects makes the development of safe, effective plasma medical devices and procedures a challenge, but encouragingly rapid progress has been reported around the world in the last several years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic piston model for higher ion charge and different electron and ion plasma temperatures

A new formula for the magnetic piston model, which explicitly describes how the momentum imparted to the ions by the magnetic pressure depends not only on the ion mass but also on the ion charge, as well as, on the plasma electron and ion temperatures, is derived following Rosenbluth's classical particle-field self-consistent plane approximation analytic calculation. The formula presented in this paper has implications in explaining the experimentally observed separation of the ions of different species and charges by the magnetic field penetrating the plasma and specularly reflecting them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High hydrogen coverage on graphene via low temperature plasma with applied magnetic field

The chemical functionalization of two-dimensional materials is an effective method for tailoring their chemical and electronic properties with encouraging applications in energy, catalysis, and electronics. One exemplary 2D material with remarkable properties, graphene, can be exploited for hydrogen storage and large on/off ratio devices by hydrogen termination. In this work, we describe a promising plasma-based method to provide high hydrogen coverage on graphene. A low pressure (~10 mtorr) discharge generates a fine-tunable low-temperature hydrogen-rich plasma in the applied radial electric and axial magnetic fields. Post-run characterization of these samples using Raman spectroscopy and X-ray photoelectron spectroscopy demonstrates a higher hydrogen coverage, 35.8%, than the previously reported results using plasmas. Plasma measurements indicate that with the applied magnetic field, the density of hydrogen atoms can be more than 10 times larger than the density without the magnetic field. With the applied electric field directed away from the graphene substrate, the flux of plasma ions towards this substrate and the ion energy are insufficient to cause measurable damage to the treated 2D material. As a result, the low damage allows a relatively long treatment time of the graphene samples that contributes to the high coverage obtained in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long-term stability of the Io high-temperature plasma torus

The short wavelength camera of the International Ultraviolet Explorer satellite was used to measure S II 1256, S III 1199, semiforbidden S III 1729, and semiforbidden S IV 1406 emission from the high-temperature region of the Io plasma torus. Observations over a period of five years (1979-1984) indicate that the Io plasma parameters have relatively small variations, particularly in the case of the mixing ratio for the dominant constituent S(++), and electron temperature. A simple three-dimensional model of the plasma torus was used to obtain the ion mixing ratios and the plasma density for each observation. The results are compared with Voyager 1 data for mixing ratio (ion density divided by electron density); ionization balance; and plasma density. The results of the comparison are discussed in detail.

Moos, H. W.↗

Chandra Grating Spectroscopy of Embedded Wind Shock X-ray Emission from O Stars Shows Low Plasma Temperatures and Significant Wind Absorption

We present a uniform analysis of six examples of embedded wind shock (EWS) O star X-ray sources observed at high resolution with the Chandra grating spectrometers. By modeling both the hot plasma emission and the continuum absorption of the soft X-rays by the cool, partially ionized bulk of the wind we derive the temperature distribution of the shock-heated plasma and the wind mass-loss rate of each star. We find a similar temperature distribution for each star’s hot wind plasma, consistent with a power-law differential emission measure, dlogEMdlogT, with a slope a little steeper than -2, up to temperatures of only about107K. The wind mass-loss rates, which are derived from the broadband X-ray absorption signatures in the spectra, are consistent with those found from other diagnostics. The most notable conclusion of this study is that wind absorption is a very important effect, especially at longer wavelengths. More than 90 per cent of the X-rays between 18 and 25 ̊A produced by shocks in the wind of ζPup are absorbed, for example. It appears that the empirical trend of X-ray hardness with spectral subtype among O stars is primarily an absorption effect.

David H Cohen↗

Generation of uniform low-temperature plasma in a pulsed non-self-sustained glow discharge with a large-area hollow cathode

Generation of plasma in a pulsed non-self-sustained glow discharge with a hollow cathode with an area of ≥2 m{sup 2} at gas pressures of 0.4–1 Pa was studied experimentally. At an auxiliary arc-discharge current of 100 A and a main discharge voltage of 240 V, a pulse-periodic glow discharge with a current amplitude of 370 A, pulse duration of 340 μs, and repetition rate of 1 kHz was obtained. The possibility of creating a uniform gas-discharge plasma with a density of up to 10{sup 12} cm{sup −3} and an electron temperature of 1 eV in a volume of >0.2 m{sup 3} was demonstrated. Such plasma can be efficiently used to treat material surfaces and generate pulsed ion beams with a current density of up to 15 mA/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion chemistry in H{sub 2}-Ar low temperature plasmas

A rate equation model is devised to study the ion composition of inductively coupled H{sub 2}-Ar plasmas with different H{sub 2}-Ar mixing ratios. The model is applied to calculate the ion densities n{sub i}, the wall loss probability of atomic hydrogen β{sub H}, and the electron temperature T{sub e}. The calculated n{sub i}'s of Ar{sup +}, H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}, and ArH{sup +} are compared with experimental results. Calculations were made for a total gas pressure of 1.0 Pa. The production and loss channels of all ions are presented and discussed in detail. With the production and loss rates, the density dependence of each ion on the plasma parameters is explained. It is shown that the primary ions H{sub 2}{sup +} and Ar{sup +} which are produced by ionization of the background gas by electron collisions are effectively converted into H{sub 3}{sup +} and ArH{sup +}. The high density of ArH{sup +} and Ar{sup +} is attributed to the low loss to the walls compared to hydrogen ions. It is shown that the H{sup +}/H{sub 2}{sup +} density ratio is strongly correlated to the H/H{sub 2} density ratio. The dissociation degree is around 1.7%. From matching the calculated to the measured atomic hydrogen density n{sub H}, the wall loss probability of atomic hydrogen on stainless steel β{sub H} was determined to be β{sub H}=0.24. The model results were compared with recently published experimental results. The calculated and experimentally obtained data are in fair agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-ion resonances in finite temperature plasma

Dispersion properties of electrostatic waves in a multi-ion plasma are examined, with an analysis that incorporates the effects of finite temperature, finite parallel wavenumber, and wave growth/damping in a systematic development of equations. Numerical solutions and analytic formulas are given for an ion plasma consisting of H(+), O(+), and S(+) for application to Jupiter's magnetosphere. It is demonstrated how observations of plasma resonance lines may be used as a diagnostic of ion composition in magnetospheric plasma. This potential use of high-sensitivity/high-resolution plasma wave instrumentation may provide information necessary to resolve issues concerning the origin of plasmas in the earth's neighborhood.

Barbosa, D. D.↗

Two-dimensional-spatial distribution measurement of electron temperature and plasma density in low temperature plasmas

A real-time measurement method for two-dimensional (2D) spatial distribution of the electron temperature and plasma density was developed. The method is based on the floating harmonic method and the real time measurement is achieved with little plasma perturbation. 2D arrays of the sensors on a 300 mm diameter wafer-shaped printed circuit board with a high speed multiplexer circuit were used. Experiments were performed in an inductive discharge under various external conditions, such as powers, gas pressures, and different gas mixing ratios. The results are consistent with theoretical prediction. Our method can measure the 2D spatial distribution of plasma parameters on a wafer-level in real-time. This method can be applied to plasma diagnostics to improve the plasma uniformity of plasma reactors for plasma processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗