Ultrasonic wave velocity measurement in small polymeric and cortical bone specimens

A system was refined for the determination of the bulk ultrasonic wave propagation velocity in small cortical bone specimens. Longitudinal and shear wave propagations were measured using ceramic, piezoelectric 20 and 5 MHz transducers, respectively. Results of the pulse transmission technique were refined via the measurement of the system delay time. The precision and accuracy of the system were quantified using small specimens of polyoxymethylene, polystyrene-butadiene, and high-density polyethylene. These polymeric materials had known acoustic properties, similarity of propagation velocities to cortical bone, and minimal sample inhomogeneity. Dependence of longitudinal and transverse specimen dimensions upon propagation times was quantified. To confirm the consistency of longitudinal wave propagation in small cortical bone specimens (< 1.0 mm), cut-down specimens were prepared from a normal rat femur. Finally, cortical samples were prepared from each of ten normal rat femora, and Young's moduli (Eii), shear moduli (Gij), and Poisson ratios (Vij) were measured. For all specimens (bone, polyoxymethylene, polystyrene-butadiene, and high-density polyethylene), strong linear correlations (R2 > 0.997) were maintained between propagation time and distance throughout the size ranges down to less than 0.4 mm. Results for polyoxymethylene, polystyrene-butadiene, and high-density polyethylene were accurate to within 5 percent of reported literature values. Measurement repeatability (precision) improved with an increase in the wave transmission distance (propagating dimension). No statistically significant effect due to the transverse dimension was detected.

Non-NASA Center↗

Polymer Energy Rechargeable System Battery Being Developed

Long description. Illustrations of discotic liquid crystals, rod-coil polymers, lithium-ion conducting channel dilithium phthalocyanine (Li2Pc) from top and side, novel star polyethylene oxide structures, composite polyethylene oxide materials (showing polyethylene oxide + lithium salt, carbon atoms and oxygen atoms), homopolyrotaxanes, and diblock copolymers In fiscal year 2000, NASA established a program to develop the next generation, lithium-based, polymer electrolyte batteries for aerospace applications. The goal of this program, known as Polymer Energy Rechargeable Systems (PERS), is to develop a space-qualified, advanced battery system embodying polymer electrolyte and lithium-based electrode technologies and to establish world-class domestic manufacturing capabilities for advanced batteries with improved performance characteristics that address NASA s future aerospace battery requirements.

Manzo, Michelle A.↗

Multi-functional layered structure having structural and radiation shielding attributes

A cosmic and solar radiation shielding structure that also has structural attributes is comprised of three layers. The first layer is 30-42 percent by volume of ultra-high molecular weight (UHMW) polyethylene fibers, 18-30 percent by volume of graphite fibers, and a remaining percent by volume of an epoxy resin matrix. The second layer is approximately 68 percent by volume of UHMW polyethylene fibers and a remaining percent by volume of a polyethylene matrix. The third layer is a ceramic material.

Kaul, Raj K.↗

Detecting strain in birefringent materials using spectral polarimetry

A method, computer program product and system for analyzing multispectral images from a plurality of regions of birefringent material, such as a polymer film, using polarized light and a corresponding polar analyzer to identify differential strain in the birefringent material. For example, the birefringement material may be low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene, polyethylene terephthalate (PET), polyvinyl chloride (PVC), polyvinylidene chloride, polyester, nylon, or cellophane film. Optionally, the method includes generating a real-time quantitative strain map.

Ragucci, Anthony J.↗

Non-Flammable Containment Bag and Enclosure Development for International Space Station Use

Work conducted on the International Space Station (ISS) requires the use of a significant quantity of containment bags to hold specimens, equipment, waste, and other material. The bags are in many shapes and sizes, and are typically manufactured from polyethylene materials. The amount of bags being used on ISS has grown to the point where fire safety has become a concern because of the flammability of polyethylene. Recently, a new re‐sealable bag design has been developed that is manufactured from a specialized non‐flammable material called Armorflex 301 that was designed specifically for this application. Besides being non‐flammable, Armorflex 301 is also FDA compliant, clear, flexible, and damage tolerant. The bags can be made with closure mechanisms that resemble ZipLoc® bags, or can be open top. Sample bags have been laboratory tested by NASA to verify materials properties, and evaluated by astronauts on the ISS in 2012. Flexloc bag manufacturing will commence in 2014 to support a transition away from polyethylene on ISS. In addition to re‐sealable bags, other larger containment systems such as flexible gloveboxes, deployable clean rooms, and other devices manufactured from Armorflex 301 are being explored for use on ISS and in similar confined space locations where flammability is an issue. This paper will describe the development of the Armorflex 301 material, the Flexloc bag, and other containment systems being explored for use in confined areas

Inamdar, Sunil↗

Preliminary Thermal Design of Cryogenic Radiation Shielding

Cryogenic Hydrogen Radiation Shielding (CHRS) is the most mass efficient material radiation shielding strategy for human spaceflight beyond low Earth orbit (LEO). Future human space flight, mission beyond LEO could exceed one year in duration. Previous radiation studies showed that in order to protect the astronauts from space radiation with an annual allowable radiation dose less than 500 mSv, 140 kgm2 of polyethylene is necessary. For a typical crew module that is 4 meter in diameter and 8 meter in length. The mass of polyethylene radiation shielding required would be more than 17,500 kg. The same radiation study found that the required hydrogen shielding for the same allowable radiation dose is 40 kgm2, and the mass of hydrogen required would be 5, 000 kg. Cryogenic hydrogen has higher densities and can be stored in relatively small containment vessels. However, the CHRS system needs a sophisticated thermal system which prevents the cryogenic hydrogen from evaporating during the mission. This study designed a cryogenic thermal system that protects the CHRS from hydrogen evaporation for one to up to three year mission. The design also includes a ground based cooling system that can subcool and freeze liquid hydrogen. The final results show that the CHRS with its required thermal protection system is nearly half of the mass of polyethylene radiation shielding.

radiation↗

Benchmark studies of the effectiveness of structural and internal materials as radiation shielding for the international space station

Accelerator-based measurements and model calculations have been used to study the heavy-ion radiation transport properties of materials in use on the International Space Station (ISS). Samples of the ISS aluminum outer hull were augmented with various configurations of internal wall material and polyethylene. The materials were bombarded with high-energy iron ions characteristic of a significant part of the galactic cosmic-ray (GCR) heavy-ion spectrum. Transmitted primary ions and charged fragments produced in nuclear collisions in the materials were measured near the beam axis, and a model was used to extrapolate from the data to lower beam energies and to a lighter ion. For the materials and ions studied, at incident particle energies from 1037 MeV/nucleon down to at least 600 MeV/nucleon, nuclear fragmentation reduces the average dose and dose equivalent per incident ion. At energies below 400 MeV/nucleon, the calculation predicts that as material is added, increased ionization energy loss produces increases in some dosimetric quantities. These limited results suggest that the addition of modest amounts of polyethylene or similar material to the interior of the ISS will reduce the dose to ISS crews from space radiation; however, the radiation transport properties of ISS materials should be evaluated with a realistic space radiation field. Copyright 2003 by Radiation Research Society.

NASA Discipline Radiation Health↗

Polymer crystallization in a temperature gradient field with controlled crystal growth rate

A method is described for studying the influence of a temperature gradient on the crystallization of quiescent polymer melts. The apparatus used consists of two brass plates with embedded electrical resistance heaters and cooling coils. The crystallizations experiments were conducted by placing polymer specimens between the paltes, and manually adjusting heaters and cooling fluids for temperature control. Linear polyethylene, isotactic polyprophylene, and a high density polyethylene were used. It is concluded that the role of a temperature gradient in producing oriented crystallization is in producing conditions which lead the spherulitic growth pattern to proceed primarily in one direction. Steep gradients diminish the penetration of supercooling and favors oriented growth.

Hansen, D.↗

Toxicity of pyrolysis gases from some synthetic polymers

Nine samples of synthetic polymers were evaluated for toxicity of pyrolysis gases, using the toxicity screening test method developed at the University of San Francisco. The materials were polyoxymethylene, polyethylene (five samples), polypropylene, polymethyl methacrylate, and polystyrene. Of the five polyethylene samples, three contained known levels of chlorine. These test results were combined with earlier data to provide a comparison of 25 samples of synthetic polymers. Polyoxymethylene appeared to exhibit the greatest toxicity, and polystyrene the least toxicity, under these particular test conditions

Hilado, C. J.↗

Concentration-time data in toxicity tests and resulting relationships

Periodic analyses for carbon monoxide and methane in the animal exposure chamber during pyrolysis of polyethylene at 800 C without forced air flow showed that the concentrations of these compounds increased with exposure time. These observations, and similar observations for polyurethane flexible foam, permitted the calculation of carbon monoxide toxicity in terms of a DP (Death Product Concentration) value, in addition to flammability in terms of HC (Hydro Carbon) value. Observed DP values exceeding the critical DP(CO) value of 47,200 ppm-min for carbon monoxide may indicate that lethal exposures were reached earlier but not immediately manifested because of the time delay involved in physiological processes. On the basis of this DP(CO) value, carbon monoxide could have been the sole toxicant in the case of polyethylene, polypropylene, polyoxymethylene, polystyrene, polycarbonate, ethylene propylene diene rubber, and wood.

Hilado, C. J.↗

Gas distribution equipment in hydrogen service - Phase II

The hydrogen permeability of three different types of commercially available natural gas polyethylene pipes was determined. Ring tensile tests were conducted on permeability-exposed and as-received samples. Hydrogen-methane leakage experiments were also performed. The results show no selective leakage of hydrogen via Poiseuille, turbulent, or orifice flow (through leaks) on the distribution of blends of hydrogen and methane. The data collected show that the polyethylene pipe is 4 to 6 times more permeable to hydrogen than to methane.

Jasionowski, W. J.↗

Fabrication and wear test of a continuous fiber/particulate composite total surface hip replacement

Continuous fiber woven E-glass composite femoral shells having the ame elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle were tests on a total hip simulator. The tribological characteristics of these shells atriculating with the acetabular cups are comparable to a vitallium bal articulating with an ultrahigh molecular weight polyethylene cup.

Roberts, J. C.↗

Electron penetration of spacecraft thermal insulation

The external thermal blanket with 13 mils of polyethylene which has the known range and stopping power as a function of electron energy is investiated. The most recent omnidirectional peak Jovian electron flux at 5 Jupiter radii is applied, the electron current penetrating the thermal blanket is calculated and allowed to impinge on a typical 20 mil polyethylene insulator surrounding a wire. The radiation dose rate to the insulator is then calculated and the electrical conductivity found. The results demonstrate that the increased electronic mobility is sufficient to keep the maximum induced electric field two orders of magnitude below the critical breakdown strength.

Powers, W. L.↗

Tribological measurements on a Charnley-type artificial hip joint

A total hip simulator was used to determine the friction and wear properties of Charnley-type (316L stainless steel balls and sterile ultrahigh molecular weight polyethylene cups) hip prostheses. Three different sets of specimens were tested to 395,000, 101,500 and 233,000 walking cycles, respectively. All tests were run unlubricated, at ambient conditions (22 to 26 C, 30 to 50 percent relative humidity), at 30 walking cycles per minute, under a dynamic load simulating walking. Polyethylene cup wear rates ranged from 1.4 to 39 ten billions cu m which corresponds to dimensional losses of 4.0 to 11 microns per year. Although these wear rates are lower than those obtained from other hip simulators and from in vivo X-ray measurements, they are comparable when taking run-in and plastic deformation into account. Maximum tangential friction forces ranged from 93 to 129 N under variable load (267 to 3090 N range) and from 93 to 143 N under a static load of 3090 N. A portion of one test 250,000 walking cycles) run under dry air ( 1 percent relative humidity) yielded a wear rate almost 6 times greater than that obtained under wet air ( 70 percent relative humidity) conditions.

Jones, W. R., Jr.↗

Sensitivity of single and multiple cosmic ray neutrons to the surrounding medium in a lead-free monitor

In 1981-1985 the neutron component of cosmic rays was recorded, the effect of cosmic ray multiplication in lead being disregarded. The recording device consisted of neutron counters placed in a polyethylene retarder (polyethylene tubes with wall thickness of 2 cm). The device registered neutrons formed directly on the surface or not deep underground; the intensity of neutrons depended on the chemical composition of the substance. The neutron component was also measured in the Moscow Canal, Belomor-Baltic Canal, and in the Atlantic Ocean. The time variation of 5 minute data of the intensity obtained in the Belomor-Baltic Canal and in the Atlantic Ocean relative to the mean value in the open sea (in %) is presented.

Dorman, I. V.↗

A device for applying plastic film antireflection coatings to optical elements

To simplify the process of thermally bonding thin plastic films to optical elements and to help eliminate the source of the flaws, a film-application device (FAD) is developed. Any plastic film may be used to make the coatings, but thin polyethylene is particularly useful for this application since it is readily available. If more than one layer of polyethylene is required, several layers may be applied, one layer at a time. The coatings may be used for protecting optical elements or to reduce surface reflection of radiation with wavelengths greater than 20 microns. When the FAD is used without the central plate it may be used to stretch single sheets of plastic material to make pellicles or beam-splitters for many applications.

Augason, G. C.↗

Recent materials problems relating to catastrophic balloon failures

Balloons fabricated of thin polyethylene materials have provided relatively inexpensive and reliable scientific research platforms for approximately three decades. Reliability of the modern day balloon, as launched by the U.S.A. National Scientific Balloon Facility (NSBF), has been approximately 85 percent. Recent balloon failures, coupled with an increased ocurrence of catastrophic failures, created grave concern over the integrity of the present balloon inventory of the U.S.A. National Aeronautics and Space Administration (NASA). An investigative team was established by NASA to review the circumstances surrounding the catastrophic balloon failures, determine the cause and to make recommendations to correct the problem and to prevent its reoccurrence. The most probable cause of failure as determined by the investigation was the polyethylene balloon film, although the film had passsed the established standard quality control measures of the film manufacturer. The approach, findings, and conclusions of the investigation are presented along with planned procedures to assure future quality balloon film for NASA balloons.

Smith, I. S.↗

Passive damping concepts for slender columns in space structures

An experimental and theoretical study of three different passive damping concepts is conducted for a slender member with partial rotational end restraints. Over a hundred full-scale natural vibration experiments were conducted to evaluate the effectiveness of mass-string, polyethylene tubing, and chain damping concepts. The damping properties obtained from the experiments were used in the approximate analyses based on the partial differential equation of motion for the problem. The comparison of the experimental and the theoretical deflection-time relations shows that the velocity-dependent damping model used in the theory is adequate. From the experimental results, the effect of end connection friction and induced axial forces on damping is identified. The definition of an efficiency index is proposed based on the damping ratio and the mass of a given passive damping device. Using this definition, the efficiencies of the three damping devices are compared. The polyethylene tubing concept resulted into a low damping efficiency.