A pressure telemeter for wind-tunnel free-flight pressure measurement
Design and performance characteristics of pressure telemeter for use on scale models in free flight in hypersonic wind tunnel
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design and performance characteristics of pressure telemeter for use on scale models in free flight in hypersonic wind tunnel
Surface pressures were measured near the tip of a hovering single-bladed model helicopter rotor with two tip shapes. The rotor had a constant-chord, untwisted blade with a square, flat tip which could be modified to a body-of-revolution tip. Pressure measurements were made on the blade surface along the chordwise direction at six radial stations outboard of the 94 percent blade radius. Data for each blade tip configuration were taken at blade collective pitch angles of 0, 6.18 and 11.4 degrees at a Reynolds number of 736,000 and a Mach number of 0.25 both based on tip speed. Chordwise pressure distributions and constant surface pressure contours are presented and discussed.
A pressure experiment at high subsonic speeds was conducted by a cambered and twisted thick delta wing at the design condition (Mach number 0.80), as well as at nearby Mach numbers (0.75 and 0.83) and over an angle-of-attack range. Effects of twin vertical tails on the wing pressure measurements were also assessed. Comparisons of detailed theoretical and experimental surface pressures and sectional characteristics for the wing alone are presented. The theoretical codes employed are FLO-57, FLO-28, PAN AIR, and the Vortex Lattice Method-Suction Analogy.
Vibrational relaxation behind incident shock waves in pure nitrogen, using end wall pressure measurements
Vibrational relaxation behind incident shock waves in CO based on shock tube pressure measurements at 2400-6000 K
An introduction to the fundamentals of total and partial pressure measurement in the vacuum regime (760 x 10 to the -16th power Torr) is presented. The instrument most often used in scientific fields requiring vacuum measurement are discussed with special emphasis on ionization type gauges and quadrupole mass spectrometers. Some attention is also given to potential errors in measurement as well as calibration techniques.
The Stand Alone Pressure Measurement Device (SAPMD) specifications are examined. The HP.SAPMD GSE software is listed; the HP/SGA readme program is presented; and the SPMD acceptance test procedure is described.
A comparison of surface pressure coefficient measurements obtained using pressure-sensitive paint (PSP) measurements with predictions from the computational fluid dynamics (CFD) code FUN3D is presented for the NASA SLS Block 1B crew vehicle. Overall, the flow features over the SLS configuration were captured by both the PSP data and CFD data at freestream Mach numbers (M(sub ∞)) of 0.8 and 1.3. Overall, the flow features over the SLS are captured by the PSP data but the intensities of large pressure gradients are less intense than what was predicted by the CFD data. Several examples of this observation are given including the flow interaction at the booster nose cone edge, core body, and forward booster attachment hardware at M(sub ∞) = 0.8.
The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent- point pressure (atmospheric pressure at the tangent height of the field of view boresight) are retrieved from a 15-channel 63-GHz radiometer measuring O2 microwave emissions from the stratosphere and mesosphere. The Version 3 data (first public release) contains scientifically useful temperatures from 22 to 0.46 hPa. Accuracy estimates are based on instrument performance, spectroscopic uncertainty and retrieval numerics, and range from 2.1 K at 22 hPa to 4.8 K at 0.46 hPa for temperature and from 200 m (equivalent log pressure) at 10 hPa to 300 m at 0.1 hPa. Temperature accuracy is limited mainly by uncertainty in instrument characterization, and tangent-point pressure accuracy is limited mainly by the accuracy of spectroscopic parameters. Precisions are around 1 K and 100 m. Comparisons are presented among temperatures from MLS, the National Meteorological Center (NMC) stratospheric analysis and lidar stations at Table Mountain, California, Observatory of Haute Provence (OHP), France, and Goddard Spaceflight Center, Maryland. MLS temperatures tend to be 1-2 K lower than NMC and lidar, but MLS is often 5 - 10 K lower than NMC in the winter at high latitudes, especially within the northern hemisphere vortex. Winter MLS and OHP (44 deg N) lidar temperatures generally agree and tend to be lower than NMC. Problems with Version 3 MLS temperatures and tangent-point pressures are identified, but the high precision of MLS radiances will allow improvements with better algorithms planned for the future.
Supressor, pressure, and ionization gauges, getter ion pumps, bakeout procedures, and adsorption in high and ultrahigh vacuum systems
Tubing connection effects on transducer response for transient pressure measurement
Base pressure measurements on XB-70 aircraft at Mach numbers from 0.4 to 3.0
Experimental pressure-differential measurements made at 10% chord of an airfoil-vortex interaction are presented. A line vortex was oscillated over an airfoil perpendicular to the span and parallel to the chord. The pressure time history was recorded in order to show the sharp pressure pulses resulting from the bursting of the vortex core as it impinges upon the airfoil. Results for various vortex sizes and free stream velocities were obtained. Measurements were also made when the airfoil was yawed to the line vortex. Maximum pressure differences were observed to occur in phase across the blade even with yaw, and were directly proportional to the square of the free stream velocity. The maximum dynamic pressure coefficients obtained were as high as 1.0 when vortex bursting occurred.
A non-invasive method and apparatus is disclosed for measuring pressure within a pliable vessel such as a blood vessel. The blood vessel is clamped by means of a clamping structure having a first portion housing a pressure sensor and a second portion extending over the remote side of the blood vessel for pressing the blood vessel into engagement with the pressure sensing device. The pressure sensing device includes a flat deflectable diaphragm portion arranged to engage a portion of the blood vessel flattened against the diaphragm by means of the clamp structure. In one embodiment, the clamp structure includes first and second semicylindrical members held together by retaining rings. In a second embodiment the clamp structure is of one piece construction having a solid semicylindrical portion and a hollow semicylindrical portion with a longitudinal slot in the follow semicylindrical portion through which a slip the blood vessel. In a third embodiment, an elastic strap is employed for clamping the blood vessel against the pressure sensing device.
Dynamic pressure measurements and power spectra obtained from hot test firing of the Space Shuttle Main Engine are reported for test stand A3.
Pressure measurements covering a range of wind velocities were made at one span location on the surface of an operating Mod-2, 2500 kW, wind turbine blade. The data, which were taken with and without vortex generators installed on the leading edge, show the existence of higher pressure coefficients than would be expected from two-dimensional wind tunnel data. These high pressure ratios may be the result of three-dimensional flow over the blade, which delays flow separation. Data are presented showing the repetitiveness of abrupt changes in the pressure distribution that occur as the blade rotates. Calculated values of suction and flap coefficients are also presented.
Amplitude and surface pressure measurements for circular cylinder in vortex flow-excited oscillation
An experimental investigation was conducted in the Langley 8-Foot Transonic Pressure Tunnel to determine the flow characteristics of rectangular cavities with varying relative dimensions at subsonic and transonic speeds. Cavities were tested with width-to-depth ratios of 1, 4, 8, and 16 for length-to-depth ratios l/h of 1 through 17.5. The maximum cavity depth was 2.4 in., and the turbulent boundary layer approaching the cavity was approximately 0.5 in. thick. Unsteady- and mean static-pressure measurements were made at free-stream Mach numbers from 0.20 to 0.95 at a unit Reynolds number per foot of approximately 3 x 10(exp 6); however, only unsteady-pressure results are presented in this paper. Results indicate that as l/h increases, cavity flows changed from resonant to nonresonant with resonant amplitudes decreasing gradually. Resonant spectra are obtained largely in cavities with mean static-pressure distributions characteristic of open and transitional flows. Resonance sometimes occurred for closed flow. Increasing cavity width or decreasing cavity depth while holding l/h fixed had the effect of increasing resonant amplitudes and sometimes induced resonance. The effects due to changes in width are more pronounced. Decreasing Mach number has the effect of broadening the resonances.