Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE PULSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Hover Acoustic Characteristics of the XV-15 with Advanced Technology Blades

An experiment has been performed to investigate the far-field hover acoustic characteristics of the XV-15 aircraft with advanced technology blades (ATB). An extensive, high-quality, far-field acoustics data base was obtained for a rotor tip speed range of 645-771 ft/s. A 12-microphone, 500-ft radius semicircular array combined with two aircraft headings provided acoustic data over the full 360-deg azimuth about the aircraft with a resolution of 15 deg. Altitude variations provided data from near in-plane to 45 deg below the rotor tip path plane. Acoustic directivity characteristics in the lower hemisphere are explored through pressure time histories, narrow-band spectra, and contour plots. Directivity patterns were found to vary greatly with azimuth angle, especially in the forward quadrants. Sharp positive pressure pulses typical of blade-vortex interactions were found to propagate aft of the aircraft and were most intense at 45 deg below the rotor plane. Modest overall sound pressure levels were measured near in-plane indicating that thickness noise is not a major problem for this aircraft when operating in the hover mode with ATB. Rotor tip speed reductions reduced the average overall sound pressure level (dB (0.0002 dyne/cm(exp 2)) by nearly 8 dB in-plane, and 12.6 deg below the rotor plane.

Conner, David A.↗

Autonomic neural control of dynamic cerebral autoregulation in humans

BACKGROUND: The purpose of the present study was to determine the role of autonomic neural control of dynamic cerebral autoregulation in humans. METHODS AND RESULTS: We measured arterial pressure and cerebral blood flow (CBF) velocity in 12 healthy subjects (aged 29+/-6 years) before and after ganglion blockade with trimethaphan. CBF velocity was measured in the middle cerebral artery using transcranial Doppler. The magnitude of spontaneous changes in mean blood pressure and CBF velocity were quantified by spectral analysis. The transfer function gain, phase, and coherence between these variables were estimated to quantify dynamic cerebral autoregulation. After ganglion blockade, systolic and pulse pressure decreased significantly by 13% and 26%, respectively. CBF velocity decreased by 6% (P<0.05). In the very low frequency range (0.02 to 0.07 Hz), mean blood pressure variability decreased significantly (by 82%), while CBF velocity variability persisted. Thus, transfer function gain increased by 81%. In addition, the phase lead of CBF velocity to arterial pressure diminished. These changes in transfer function gain and phase persisted despite restoration of arterial pressure by infusion of phenylephrine and normalization of mean blood pressure variability by oscillatory lower body negative pressure. CONCLUSIONS: These data suggest that dynamic cerebral autoregulation is altered by ganglion blockade. We speculate that autonomic neural control of the cerebral circulation is tonically active and likely plays a significant role in the regulation of beat-to-beat CBF in humans.

Non-NASA Center↗

Blood-Pressure Measuring System Gives Accurate Graphic Output

The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

Source record↗

Numerical modeling of the vortex/airfoil interaction

A modeling of the vortex-airfoil interaction is presented in which the finite-area of the real vortices is taken into consideration. Two vortex models are used. In the first, a disturbed piece of vorticity layer is simulated by four rows of discrete vortices of small strength. In the second, a number of discrete vortices is arranged within a circle. The first model may simulate a shear layer or a wake, while the second, a well-formed vortex. The method was applied to the calculation of the pressure induced on the surface of the airfoil by the interacting vortex. Both models give similar results. It was found that for large distances of the vortex from the surface of the airfoil, the consideration or not of the finite-area of the vortex is not a significant factor in determining the induced pressure field. However, when the distance of the vortex from the surface is reduced, its shape is distorted and the induced pressure pulses have lower amplitude than the ones induced by an equivalent point vortex. In the limit, where the vortex impinges on the leading edge of the airfoil, it is split into two and the time dependent pressure coefficient takes even negative values at some time intervals.

Panaras, Argyris G.↗

A comprehensive analysis of transient pressure and rate data from CO 2 storage projects in a depleted pinnacle reef oil field complex, Michigan, USA

Pressure and rate data are commonly recorded as part of a basic monitoring program in CCS projects. This paper discusses the application of multiple analytical techniques to interpret pressure and rate transient data from CO 2 injection and storage operations. The techniques of interest, i.e., injection-falloff analysis, injectivity/productivity index analysis and pressure pulse arrival time analysis, are commonly used in the oil and gas industry to assess reservoir properties, but not well known in the CCS literature (especially the last two). Injection-falloff analysis involves log-log pressure derivative plotting for the falloff data and history-matching of the entire injection-falloff sequence to determine permeability. In the injectivity/productivity index analysis, rate-normalized pressure buildup is plotted against material balance time or ratio of cumulative injection to injection rate to determine the injectivity index (ratio of injection rate to stabilized pressure buildup) which can be related to the permeability-thickness product. The arrival time analysis identifies the arrival of a pressure disturbance (~0.1 psi change from ambient) to determine the hydraulic diffusivity from which permeability can be estimated. The applicability of these techniques is demonstrated via illustrative examples from multiple wells in different pinnacle carbonate reefs undergoing CO 2 -EOR in Northern Michigan. The paper ends with a discussion of the relative merits of each interpretive technique, as well as recommendations that could be useful for other field projects.

42 ENGINEERING↗

Onset of cavitation and vapor bubble development over hydrophilic and hydrophobic surfaces

Cavitation, the formation of vapor bubbles as the liquid pressure is reduced below the saturated vapor pressure, often requires a substantial negative relative pressure in a pure liquid. Classical nucleation theory (CNT) provides an estimate for the rate of cavitation but there is often a disconnect between the predictions at the molecular scale compared to observations at the macroscale. We report on mesoscale simulations of cavitation based on many-body dissipative particle dynamics (mDPD), a coarse-grained molecular dynamics (MD), which bridges the two scales. A liquid layer is confined between smooth planar walls at a constant temperature, while the pressure is reduced slowly by expanding the wall-bounded domain. The wetting properties of the liquid are determined by the parameters of the interaction potentials. With hydrophilic walls, homogeneous nucleation is observed in the liquid bulk. As a bubble forms and grows, it creates a strong pressure pulse and oscillations that cause other bubbles that may have formed slightly later to collapse. For a nearly neutral wall with a contact angle close to 90 ° , heterogeneous nucleation occurs at the walls at a smaller negative pressure and generates weaker pressure oscillations. With hydrophobic walls or seed particles, heterogeneous nucleation readily occurs, where fluctuations and the merger of transient surface bubbles are significant.

Science & Technology - Other Topics↗

Development of an Ejectable Data Recorder Ejection Mechanism for the Low Earth Orbit Flight Test of an Inflatable Decelerator

On November 10, 2022, the 1100kg (2,425 lbs.) LOFTID Reentry Vehicle (RV) was launched on a United Launch Alliance Atlas V as a secondary payload with the Joint Polar Surveyor System-2. The 6-meter diameter (~20 ft.) aeroshell (a type of heat shield) entered the atmosphere at 8 kilometers per second (18,000 miles per hour), and flew nominally, enduring the intended heat pulse that saw temperatures exceeding 1371˚C (2500˚F) on the front side while the payload skin remained only about 38˚C (100˚F). The RV exceeded Mach 30 and the heat-affected aeroshell withstood a pressure pulse that exerted 9g’s deceleration maintaining stable flight through the hypersonic, supersonic, transonic, and subsonic regimes to the parachute deployment. As part of the Agency’s strategic goal “to extend human presence deeper into space and to the moon for sustainable long-term exploration and utilization”, the LOFTID inflatable aerodynamic decelerator or aeroshell technology could one day help land humans on Mars. As with any flight test, data collection is of utmost importance. Without a data downlink and a possibility of the RV sinking before the recovery crew got to it, a secondary data collection method was introduced. The RV would eject a data recorder, which would have a duplicate copy of the on-board flight date, before splashdown and be retrieved separately. This paper discusses the development of the ejection mechanism used to eject the data recorder from the RV during the test flight. The development includes discussions of design constraints, a design overview, the testing program, and lessons learned throughout the process all the way through successful data recorder recovery.

mechanism↗

Lower body negative pressure, experiment M092

Evaluation of orthostatic intolerance has been achieved by the use of lower body negative pressure (LBNP). The LBNP technique, though independent of gravity, simulates its effect by exposing the legs and the lower abdomen to reduced ambient pressures. This LBNP experiment, conducted during the 56-day simulation of the Skylab environment, was designed to supply baseline information on cardiovascular responses to periodic orthostatic stress. Impaired orthostatic tolerance, manifested by the increased heart rate, diminished systolic and pulse pressure, and increased tendency to syncope in the upright position, or during LBNP, was not observed in this experiment.

Johnson, R. L.↗

Leading-edge pressure measurements of airfoil vortex interaction

Experimental pressure-differential measurements made at 10% chord of an airfoil-vortex interaction are presented. A line vortex was oscillated over an airfoil perpendicular to the span and parallel to the chord. The pressure time history was recorded in order to show the sharp pressure pulses resulting from the bursting of the vortex core as it impinges upon the airfoil. Results for various vortex sizes and free stream velocities were obtained. Measurements were also made when the airfoil was yawed to the line vortex. Maximum pressure differences were observed to occur in phase across the blade even with yaw, and were directly proportional to the square of the free stream velocity. The maximum dynamic pressure coefficients obtained were as high as 1.0 when vortex bursting occurred.

Walsh, R. G., Jr.↗

Lower body negative pressure: Third manned Skylab mission

The crew of the Skylab 4 Mission exhibited physiological changes during their 84-day mission that resembled but in several important areas did not reach the magnitude of changes exhibited in crewmen of the two earlier Skylab flights. At rest all three crewmen showed, in comparison to preflight levels, elevated mean systolic and pulse pressures and decreased mean diastolic and mean arterial pressures. Similar changes were seen in most Skylab 2 and Skylab 3 crewmen. While mean resting heart rates of both the Skylab 3 and Skylab 4 crews were elevated, those of the Skylab 2 crew were, however, lower than during preflight tests. Stressed heart rates followed previous patterns in being consistently elevated over preflight values. Postflight changes in cardiovascular parameters for the most part resembled those seen in previous crewmen of space missions. Their recovery to preflight limits occurred rapidly. In-flight data and subjective impressions of the crewmen confirmed that lower body negative pressure in weightlessness imposed a greater stress upon the cardiovascular system than in earth's gravity.

Johnson, R. L.↗

Lower body negative pressure - The second manned Skylab mission

Results of orthostatic evaluations of the crew of Skylab 3 with lower body negative pressure (LBNP) stress tests during their 59-d mission are reported. Except for an inflight increase (rather than a decrease) in resting heart rates, results were essentially parallel to those observed in crewmen of the shorter Skylab 2 mission. Exaggerated elevations in heart rate and decreases in pulse pressure during LBNP stress inflight and immediately postflight corresponded to lowered orthostatic tolerance. Large decrements is resting calf size inflight and in total leg volume postflight indicated significant headward fluid shifts as had already been seen in the Skylab 2 crewmen. In addition, decreases in calf circumference gave no certain indication of a plateau over the 59 d inflight. Percentage volume increase in calf size during LBNP stress inflight was greater than those in either preflight or postflight tests.

Johnson, R. L.↗

Rat cardiovascular responses to whole body suspension - Head-down and non-head-down tilt

Two experiments aimed at examining the versatility of the whole body suspension (WBS) system as a ground-based model for cardiovascular effects of microgravity are described. The first experiment studied heart rate and arterial pressure responses in rats during a 7-day period of head-down tilt (HDT) or nonhead-down tilt (NHDT) and after removal from whole body suspension (WBS). Mean arterial (MAP), systolic, and diastolic pressures increased about 20 percent in HDT rats on the fist day, heart rates were elevated about 10 percent. During postsuspension most cardiovascular parameters returned to presuspension levels. The second experiment evaluated responses to rapid head-up tilt in HDT and NHDT rats. It was observed that, while pulse pressures remained unchanged, MAP, systolic and diastolic pressures, and HR were elevated in HDT and NHDT rats during head-up tilt after one day of suspension. The WBS rats are considered to be useful as a model to better understand responses of rats exposed to microgravity.

Musacchia, X. J.↗

Apollo flight crew cardiovascular evaluations

The results of the lower body negative pressure (LBNP) and passive stand tests are presented, and the efficacy of the experimental antihypotensive garments is evaluated. Results of the tests are presented in tabular form. Postflight orthostatic evaluations during the Apollo program indicate that reduction in orthostatic tolerance is a consequence of space flight exposure. Heart rate, the most reliable index, was increased, while systolic and pulse pressures were decreased during immediate postflight evaluations using lower body negative pressure and passive standing as the orthostatic stress. Elevation in resting heart rate was a less frequent finding. There was considerable variability in the magnitude of these changes between individual crewmembers and in the persistence of the changes over subsequent postflight evaluations. Postflight changes in leg volume during LBNP were equal to or less than those seen during preflight baseline evaluations. Body weight, resting calf girth, supine leg volume, and cardiothoracic ratios were all diminished immediately postflight, and return to preflight values was not complete within the postflight testing time frame.

G.W. Hoffler↗

Tolerance of Lower Body Negative Pressure (LBNP) in endurance runners, weightlifters, swimmers and nonathletes

Thirteen endurance runners (R), 12 weightlifters (WL), 12 swimmers (SW) and 10 nonathletes (NA) were tested for their tolerance of lower body negative pressure (LBNP) in consecutive 5 minute stages at -20, -30, -40, -50 and -60 torr. Each subject also performed an exercise test on a bicycle ergometer with progressive workloads to exhaustion to determined aerobic capacity. The R had a much higher aerobic capacity than any of the other groups, but a significantly lower LBNP tolerance. While responses in heart rate and pulse pressure were quite similar in all 4 groups, the rate of increase in leg volume relative to LBNP stress (leg compliance, LC) was considerably greater in R than in the other athletes and NA. The greater LC in R could be attributed not only to a more rapid shift of blood to the lower extremities but also to a greater tendency for edema formation, both contributing to a more rapid loss in effective central blood volume for a given LBNP stress. These results substantiate earlier observations which led to the conclusion that endurance running is not advisable as a training regimen for astronauts.

Source record↗

Experimental and theoretical investigation of stress wave attenuation in fiber reinforced composites.

The propagation of an initialrcidrical pressure pulse through a linear elastic fiber reinforced composite medium is analysed, both experimentally and analytically. In the experiment, tests were performed on plates with single and multiple circular inclusions embedded in a matrix of lower characteristic impedance. Sharp compression pulses were generated at an edge of the plate. Strain gages were mounted on various positions of the plate to determine the attenuation of the transient stress in the fiber reinforced composite. The qualitative analytical treatment is based on the methods of propagating stress discontinuities. Computer programs were written to numerically determine the changes in the shape of the leading wave front and the stresses immediately behind it. Experimental results for the attenuation of stress wave on steel-aluminum and steel-brass fiber-matrix composites compared very well with the computed analytical results when the applied pressure is generated by small explosive charges. The results did not compare well when the applied pressure is generated by projectile impact.

Yang, J. C. S.↗

Pressurizing Hagan and SAVY containers to 30-psig (air) to measure the release of analytical cerium oxide test powder

In response to an ESS surrounding the storage of sealed sources at TA-55, personnel from RP-SVS (Radiation Protection Services) and ORI-2 (Operational Readiness & Execution) were approached by ES-55 (Facility System Engineering) to provide technical testing of known nuclear material storage containers. Testing criteria were determined by SB-PF (Safety Basis for Plutonium Facilities). Tests were conducted in conjunction with multiple related projects at the Aerosol Sciences Laboratory (TA-03-0130-0103). An experimental system was quickly developed to deliver a pressure pulse (30-psig) that mimics a sealed source burst scenario. A series of twelve tests was conducted. Six tests were done with two different 5QT SAVY-4000 containers, where each SAVY filter-lid combination was subjected to three successive test insults. Three tests were done with a (0.375" diameter filter) 8Q.T Hagan container, and three tests with a (0.625" diameter filter) 8QT Hagan container. An unused, fresh container filter was used for each tested Hagan container, each receiving only one test insult per filter. Cerium oxide (CeO 2 ) powder was loaded (100 grams per test) into a nozzle in the tested Hagan and SAVY containers, and the nozzle was hard-plumbed to a ball valve and a pressure source. This system was installed into the Los Alamos RRFMC (Respirable Release Measurement Chamber), which is an integrated multipurpose aerosol wind tunnel that satisfies NQA-1 subpart 2.4 for R&D work. The ball valve was fitted with a mechanical linkage for operation from outside the wind tunnel. An aerodynamic particle sizer counted the particle concentrations and size distributions of released aerosol. Respirable aerosol released during the tests was measured and a correction factor for wind tunnel flowrate and internal duct deposition was applied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hypocapnia and cerebral hypoperfusion in orthostatic intolerance

BACKGROUND AND PURPOSE: Orthostatic and other stresses trigger tachycardia associated with symptoms of tremulousness, shortness of breath, dizziness, blurred vision, and, often, syncope. It has been suggested that paradoxical cerebral vasoconstriction during head-up tilt might be present in patients with orthostatic intolerance. We chose to study middle cerebral artery (MCA) blood flow velocity (BFV) and cerebral vasoregulation during tilt in patients with orthostatic intolerance (OI). METHODS: Beat-to-beat BFV from the MCA, heart rate, CO2, blood pressure (BP), and respiration were measured in 30 patients with OI (25 women and 5 men; age range, 21 to 44 years; mean age, 31.3+/-1.2 years) and 17 control subjects (13 women and 4 men; age range, 20 to 41 years; mean age, 30+/-1.6 years); ages were not statistically different. These indices were monitored during supine rest and head-up tilt (HUT). We compared spontaneous breathing and hyperventilation and evaluated the effect of CO2 rebreathing in these 2 positions. RESULTS: The OI group had higher supine heart rates (P<0.001) and cardiac outputs (P<0.01) than the control group. In response to HUT, OI patients underwent a greater heart rate increment (P<0.001) and greater reductions in pulse pressure (P<0.01) and CO2 (P<0.001), but total systemic resistance failed to show an increment. Among the cerebrovascular indices, all BFVs (systolic, diastolic, and mean) decreased significantly more, and cerebrovascular resistance (CVR) was increased in OI patients (P<0.01) compared with control subjects. In both groups, hyperventilation induced mild tachycardia (P<0.001), a significant reduction of BFV, and a significant increase of CVR associated with a fall in CO2. Hyperventilation during HUT reproduced hypocapnia, BFV reduction, and tachycardia and worsened symptoms of OI; these symptoms and indices were improved within 2 minutes of CO2 rebreathing. The relationships between CO2 and BFV and heart rate were well described by linear regressions, and the slope was not different between control subjects and patients with OI. CONCLUSIONS: Cerebral vasoconstriction occurs in OI during orthostasis, which is primarily due to hyperventilation, causing significant hypocapnia. Hypocapnia and symptoms of orthostatic hypertension are reversible by CO2 rebreathing.

Non-NASA Center↗

Statistical distributions for transient transport

Here, this paper introduces the use of statistical distributions based on transport differential equations for clear distinction of transport modes within transient kinetic experiments. More specifically, novel techniques are developed for the transient data obtained through the Temporal Analysis of Products (TAP) reactor and are applicable to experiments where pulse response into a gas flow is used. The methodology allows distinguishing between two domains of diffusion transport in heterogeneous catalytic systems, i.e., Knudsen and non-Knudsen diffusion, using statistical fingerprints, and finding the transition domain. Two distribution parameters were obtained that directly result in coefficients that correspond to the concentration and the rate of transport. Using a linear relationship between the rate and concentration coefficients, Knudsen diffusion is revealed when the rate of transport is constant and non-Knudsen diffusion is confirmed when the rate of transport coefficient is a function of the concentration coefficient. As a result, accurate transport information can be extracted from experimental data even in the presence of comprising instrument drift or noise particularly when analyzing higher pressure pulse responses with complex transport. This enables more direct investigation of experiments influenced by gas-phase reactions.

TAP reactor↗