Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Constructing a resilience index for the Enhanced Critical Infrastructure Protection Program

Following recommendations made in Homeland Security Presidential Directive 7, which established a national policy for the identification and increased protection of critical infrastructure and key resources (CIKR) by Federal departments and agencies, the U.S. Department of Homeland Security (DHS) in 2006 developed the Enhanced Critical Infrastructure Protection (ECIP) program. The ECIP program aimed to provide a closer partnership with state, regional, territorial, local, and tribal authorities in fulfilling the national objective to improve CIKR protection. The program was specifically designed to identify protective measures currently in place in CIKR and to inform facility owners/operators of the benefits of new protective measures. The ECIP program also sought to enhance existing relationships between DHS and owners/operators of CIKR and to build relationships where none existed (DHS 2008; DHS 2009). In 2009, DHS and its protective security advisors (PSAs) began assessing CIKR assets using the ECIP program and ultimately produced individual protective measure and vulnerability values through the protective measure and vulnerability indices (PMI/VI). The PMI/VI assess the protective measures posture of individual facilities at their 'weakest link,' allowing for a detailed analysis of the most vulnerable aspects of the facilities (Schneier 2003), while maintaining the ability to produce an overall protective measures picture. The PMI has six main components (physical security, security management, security force, information sharing, protective measures assessments, and dependencies) and focuses on actions taken by a facility to prevent or deter the occurrence of an incident (Argonne National Laboratory 2009). As CIKR continue to be assessed using the PMI/VI and owners/operators better understand how they can prevent or deter incidents, academic research, practitioner emphasis, and public policy formation have increasingly focused on resilience as a necessary component of the risk management framework and infrastructure protection. This shift in focus toward resilience complements the analysis of protective measures by taking into account the three other phases of risk management: mitigation, response, and recovery (Figure 1). Thus, the addition of a robust resilience index (RI) to the established PMI/VI provides vital information to owners/operators throughout the risk management process. Combining a pre-incident focus with a better understanding of resilience, as well as potential consequences from damaged CIKR, allows owners/operators to better understand different ways to decrease risk by (1) increasing physical security measures to prevent an incident, (2) supplementing redundancy to mitigate the effects of an incident, and (3) enhancing emergency action and business continuity planning to increase the effectiveness of recovery procedures. Information provided by the RI methodology is also used by facility owners/operators to better understand how their facilities compare to similar sector/subsector sites and to help them make risk-based decisions. This report provides an overview of the RI methodology developed to estimate resilience and provide resilience comparisons for sectors and subsectors. The information will be used to (1) assist DHS in analyzing existing response and recovery methods and programs at facilities and (2) identify potential ways to increase resilience. The RI methodology is based on principles of Appreciative Inquiry, which is 'the coevolutionary search for the best in people, their organizations, and the relevant world around them' (Cooperrider et al. 2005). Appreciative Inquiry identifies the best of 'what is' and helps to envision 'what might be.' The ECIP program and the RI represent a new model (using Appreciative Inquiry principles) for information sharing between government and industry (Fisher and Petit 2010). A 'dashboard' display, which provides an interactive tool - rather than a static report, presents the results of the RI in a convenient format. Additional resilience measures can be modeled to illustrate how such actions would impact the asset's RI value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MO-E-213-01: Increasing Role of Medical Physicist in Radiation Protection

The focus of work of medical physicists in 1980’s was on quality control and quality assurance. Radiation safety was important but was dominated by occupational radiation protection. A series of over exposures of patients in radiotherapy, nuclear medicine and observation of skin injuries among patients undergoing interventional procedures in 1990’s started creating the need for focus on patient protection. It gave medical physicists new directions to develop expertise in patient dosimetry and dose management. Publications creating awareness on cancer risks from CT in early part of the current century and over exposures in CT in 2008 brought radiation risks in public domain and created challenging situations for medical physicists. Increasing multiple exposures of individual patient and patient doses of few tens of mSv or exceeding 100 mSv are increasing the role of medical physicists. Expansion of usage of fluoroscopy in the hands of clinical professionals with hardly any training in radiation protection shall require further role for medical physicists. The increasing publications in journals, recent changes in Safety Standards, California law, all increase responsibilities of medical physicists in patient protection. Newer technological developments in dose efficiency and protective devices increase percentage of time devoted by medical physicists on radiation protection activities. Without radiation protection, the roles, responsibilities and day-to-day involvement of medical physicists in diagnostic radiology becomes questionable. In coming years either medical radiation protection may emerge as a specialty or medical physicists will have to keep major part of day-to-day work on radiation protection. Learning Objectives: To understand how radiation protection has been increasing its role in day-to-day activities of medical physicist To be aware about international safety Standards, national and State regulations that require higher attention to radiation protection than in past To be aware about possible emergence of medical radiation protection as a specialty and challenges for medical physicists.

60 APPLIED LIFE SCIENCES↗

MO-E-213-02: Medical Physicist Involvement in Implementing Patient Protection Standards

The focus of work of medical physicists in 1980’s was on quality control and quality assurance. Radiation safety was important but was dominated by occupational radiation protection. A series of over exposures of patients in radiotherapy, nuclear medicine and observation of skin injuries among patients undergoing interventional procedures in 1990’s started creating the need for focus on patient protection. It gave medical physicists new directions to develop expertise in patient dosimetry and dose management. Publications creating awareness on cancer risks from CT in early part of the current century and over exposures in CT in 2008 brought radiation risks in public domain and created challenging situations for medical physicists. Increasing multiple exposures of individual patient and patient doses of few tens of mSv or exceeding 100 mSv are increasing the role of medical physicists. Expansion of usage of fluoroscopy in the hands of clinical professionals with hardly any training in radiation protection shall require further role for medical physicists. The increasing publications in journals, recent changes in Safety Standards, California law, all increase responsibilities of medical physicists in patient protection. Newer technological developments in dose efficiency and protective devices increase percentage of time devoted by medical physicists on radiation protection activities. Without radiation protection, the roles, responsibilities and day-to-day involvement of medical physicists in diagnostic radiology becomes questionable. In coming years either medical radiation protection may emerge as a specialty or medical physicists will have to keep major part of day-to-day work on radiation protection. Learning Objectives: To understand how radiation protection has been increasing its role in day-to-day activities of medical physicist To be aware about international safety Standards, national and State regulations that require higher attention to radiation protection than in past To be aware about possible emergence of medical radiation protection as a specialty and challenges for medical physicists.

60 APPLIED LIFE SCIENCES↗

MO-E-213-03: Newer Radiation Protection Requirements in Last Decade

The focus of work of medical physicists in 1980’s was on quality control and quality assurance. Radiation safety was important but was dominated by occupational radiation protection. A series of over exposures of patients in radiotherapy, nuclear medicine and observation of skin injuries among patients undergoing interventional procedures in 1990’s started creating the need for focus on patient protection. It gave medical physicists new directions to develop expertise in patient dosimetry and dose management. Publications creating awareness on cancer risks from CT in early part of the current century and over exposures in CT in 2008 brought radiation risks in public domain and created challenging situations for medical physicists. Increasing multiple exposures of individual patient and patient doses of few tens of mSv or exceeding 100 mSv are increasing the role of medical physicists. Expansion of usage of fluoroscopy in the hands of clinical professionals with hardly any training in radiation protection shall require further role for medical physicists. The increasing publications in journals, recent changes in Safety Standards, California law, all increase responsibilities of medical physicists in patient protection. Newer technological developments in dose efficiency and protective devices increase percentage of time devoted by medical physicists on radiation protection activities. Without radiation protection, the roles, responsibilities and day-to-day involvement of medical physicists in diagnostic radiology becomes questionable. In coming years either medical radiation protection may emerge as a specialty or medical physicists will have to keep major part of day-to-day work on radiation protection. Learning Objectives: To understand how radiation protection has been increasing its role in day-to-day activities of medical physicist To be aware about international safety Standards, national and State regulations that require higher attention to radiation protection than in past To be aware about possible emergence of medical radiation protection as a specialty and challenges for medical physicists.

60 APPLIED LIFE SCIENCES↗

Environmental variables associated with vacationers' sun protection at warm weather resorts in North America

Background: Vacationing at sunny, warm weather locations is a risk factor for excessive solar ultraviolet (UV) radiation exposure and skin cancer. Objectives: This study examined the association of environmental variables related to UV levels with vacationers' sun protection. Methods: Vacationers at 41 summer resorts in 17 states and 1 Canadian Province were interviewed (n=3531) and observed (N=4347) during 2012 and 2013. Clothing coverage, sunglasses, and shade use were observed. Use of sunscreen and sunburns were self-reported. Environmental information was recorded by research staff or acquired from ground stations and the weather service. Results: Temperature was positively associated with sun protection behaviors; however clothing coverage was negatively associated with temperature. Cloud cover was negatively associated with sun protection, with the exception of clothing coverage which was positively associated with it. Elevation showed a mixed pattern of associations with vacationer's sun protection. Latitude of a resort was negatively associated with most sun protection behaviors, such that sun protection increased at more southerly resorts. Similarly, the farther south a vacationer traveled to the resort, the less sun protection they employed. The UV index showed a weak, positive relationship with some sun protection behaviors even when controlling for temperature. Conclusions: Vacationers appeared aware that UV is higher at southern latitudes and may learn UV is intense when living in southern regions. However, many used temperature, an unreliable cue, to judge UV intensity and seemed to adjust clothing for warmth not UV protection. Efforts are needed to help individuals make more accurate sun safety decisions. - Highlights: • Vacationers poorly monitor and protect against environmental ultraviolet radiation (UVR). • On cloudy days vacationers fail to protect against UVR. • Temperature is erroneously used by vacationers as a marker for UVR. • Clothing is used primarily by vacationers for warmth, not UVR protection. • The farther south a vacationer travels, the more likely they are to sunburn.

79 ASTRONOMY AND ASTROPHYSICS↗

Handbook for Designing MMOD Protection

Spacecraft are subject to micro-meteoroid and orbital debris (MMOD) impact damage which have the potential to degrade performance, shorten the mission, or result in catastrophic loss of the vehicle. Specific MMOD protection requirements are established by NASA for each spacecraft early in the program/project life, to ensure the spacecraft meets desired safety and mission success goals. Both the design and operations influences spacecraft survivability in the MMOD environment, and NASA considers both in meeting MMOD protection requirements. The purpose of this handbook is to provide spacecraft designers and operations personnel with knowledge gained by NASA in implementing effective MMOD protection for the International Space Station, Space Shuttle, and various science spacecraft. It has been drawn from a number of previous publications [10-14], as well as new work. This handbook documents design and operational methods to reduce MMOD risk. In addition, this handbook describes tools and equations needed to design proper MMOD protection. It is a living report, in that it will be updated and re-released periodically in future with additional information. Providing effective and efficient MMOD protection is essential for ensuring safe and successful operations of spacecraft and satellites. A variety of shields protect crew modules, external pressurized vessels and critical equipment from MMOD on the International Space Station (ISS). Certain Space Shuttle Orbiter vehicle systems are hardened from MMOD impact, and operational rules are established to reduce the risk from MMOD (i.e., flight attitudes are selected and late inspection of sensitive thermal protection surfaces are conducted to reduce MMOD impacts). Science spacecraft include specific provisions to meet MMOD protection requirements in their design (for example, Stardust & GLAST). Commercial satellites such as Iridium and Bigelow Aerospace Genesis spacecraft incorporate MMOD protection. The development of low-weight, effective MMOD protection has enabled these spacecraft missions to be performed successfully. This handbook describes these shielding techniques. For future exploration activities to the Moon and Mars, implementing high-performance MMOD shielding will be necessary to meet protection requirements with minimum mass penalty. A current area of technology development in MMOD shielding is the incorporation of sensors to detect and locate MMOD impact damage. Depending on the type of sensor the signals from the sensor can be processed to infer the location of the impact and the extent of damage. The objective of the sensors is to locate critical damage that would endanger the spacecraft or crew immediately or during reentry (such as an air leak from crew module or critical damage to thermal protection system of reentry vehicles). The information from the sensors can then be used with repair kits, patch kits, hatch closure or other appropriate remedial techniques to reduce MMOD risk.

Arnold, Jim↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection of U.S. streams is insufficient to safeguard stream diversity and prevent habitat impairment

Despite covering a small portion of Earth’s surface, streams support a disproportionate amount of biodiversity. Here, we measure progress against the Global Biodiversity Framework 30×30 protection target for streams within the conterminous U.S., in terms of quantity, representation, and effectiveness of habitat protection under primarily land-based protection strategies. We evaluated the geophysical and biogeographical diversity of streams falling under protection measures. Additionally, we expose a paradox of streams being protected yet simultaneously impaired from human disturbances. Without considering impairment, approximately 30% of streams are currently protected through land-based conservation of their local or upstream watersheds; when considering impairment, only 9% to 28% of streams are truly protected from disturbances depending on impairment thresholds and protection criteria. Furthermore, despite protection approaching 30×30 targets, only 5% of the most prevalent physical stream habitat types are protected. We provide a targeted protection strategy, overcoming the impairment paradox and ensuring adequate representation of streams.

Biogeography↗

NASA Manned Launch Vehicle Lightning Protection Development

Historically, the National Aeronautics and Space Administration (NASA) relied heavily on lightning avoidance to protect launch vehicles and crew from lightning effects. As NASA transitions from the Space Shuttle to the new Constellation family of launch vehicles and spacecraft, NASA engineers are imposing design and construction standards on the spacecraft and launch vehicles to withstand both the direct and indirect effects of lightning. A review of current Space Shuttle lightning constraints and protection methodology will be presented, as well as a historical review of Space Shuttle lightning requirements and design. The Space Shuttle lightning requirements document, NSTS 07636, Lightning Protection, Test and Analysis Requirements, (originally published as document number JSC 07636, Lightning Protection Criteria Document) was developed in response to the Apollo 12 lightning event and other experiences with NASA and the Department of Defense launch vehicles. This document defined the lightning environment, vehicle protection requirements, and design guidelines for meeting the requirements. The criteria developed in JSC 07636 were a precursor to the Society of Automotive Engineers (SAE) lightning standards. These SAE standards, along with Radio Technical Commission for Aeronautics (RTCA) DO-160, Environmental Conditions and Test Procedures for Airborne Equipment, are the basis for the current Constellation lightning design requirements. The development and derivation of these requirements will be presented. As budget and schedule constraints hampered lightning protection design and verification efforts, the Space Shuttle elements waived the design requirements and relied on lightning avoidance in the form of launch commit criteria (LCC) constraints and a catenary wire system for lightning protection at the launch pads. A better understanding of the lightning environment has highlighted the vulnerability of the protection schemes and associated risk to the vehicle, which has resulted in lost launch opportunities and increased expenditures in manpower to assess Space Shuttle vehicle health and safety after lightning events at the launch pad. Because of high-percentage launch availability and long-term on-pad requirements, LCC constraints are no longer considered feasible. The Constellation vehicles must be designed to withstand direct and indirect effects of lightning. A review of the vehicle design and potential concerns will be presented as well as the new catenary lightning protection system for the launch pad. This system is required to protect the Constellation vehicles during launch processing when vehicle lightning effects protection might be compromised by such items as umbilical connections and open access hatches.

McCollum, Matthew B.↗

Adaptive protection opportunities, gap assessments, and designs

This report provides a comprehensive overview of adaptive protection schemes in use by distribution systems for protection, switching and control on their systems. A significant focus is placed on how existing schemes can be impacted by increasing penetrations of DER as well as how these schemes can enable DER penetrations to increase. EPRI have conducted a survey of member utilities and performed a comprehensive literature review with the goal of baselining the research and identifying gaps with a focus on the issues that were encountered with adaptive protection on real systems. The five adaptive protection applications that are most prevalent on systems today are discussed in detail. These are weather-based fuse-saving, adaptive protection to reduce short-circuit current, adaptive protection for DER, adaptive protection for microgrids, and distribution automation. A broad overview of the technology is given for each scheme. Issues that have been encountered by utilities are highlighted and the safety and reliability impacts are also examined. As distribution systems, intelligent electronic devices, grid equipment and distribution management systems are rapidly evolving, adaptive protection techniques and technologies will become more widely adopted. This report proposes a framework for a conceptual automatic adaptive protection system. EPRI have ongoing research, development and demonstration projects in all of the constituent elements, however challenges remain to link the elements together in a secure and reliable way. EPRI will continue research into automated adaptive protection applications and challenges for the systems of today and future applications to assist system operators in managing the evolving system.

14 SOLAR ENERGY↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Verification of Adaptive Protection in Hardware in the Loop for Coordination with Solar Variability

As inverter-based resources continue to be installed at all levels of the electric grid, the fixed protection schemes used at the distribution level will continue to be stressed until they no longer ensure the protection of the grid. Adaptive protection has been proposed as a solution with the ability to update the protection schemes in near real-time to ensure reliability and increase the resilience of the grid. However, weather variability poses a significant challenge to the ability of these methods to keep the selectivity and reliability of these schemes coordinated. If the ramp rates, due to solar variability, of the inverter-based resources change faster than the adaptive protection can issue new settings, the protection system could be uncoordinated, with the wrong device responding to a system fault. The proposed adaptive protection method ensures that due to solar variability, communication, and protection calculation latency, it can issu e coordinated protection settings promptly, in one minute or less. The hardware-in-the-loop results show the protection settings being issued and maintaining system coordination in under a minute.

Summers, Adam↗

Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"

The Department of Energy's Los Alamos National Laboratory (Los Alamos) maintains some of the Nation's most important national security assets, including nuclear materials. Many of Los Alamos' facilities are located in close proximity to one another, are occupied by large numbers of contract and Federal employees, and support activities ranging from nuclear weapons design to science-related activities. Safeguarding against fires, regardless of origin, is essential to protecting employees, surrounding communities, and national security assets. On June 1, 2006, Los Alamos National Security, LLC (LANS), became the managing and operating contractor for Los Alamos, under contract with the Department's National Nuclear Security Administration (NNSA). In preparation for assuming its management responsibilities at Los Alamos, LANS conducted walk-downs of the Laboratory's facilities to identify pre-existing deficiencies that could give rise to liability, obligation, loss or damage. The walk-downs, which identified 812 pre-existing fire protection deficiencies, were conducted by subject matter professionals, including fire protection experts. While the Los Alamos Site Office has overall responsibility for the effectiveness of the fire protection program, LANS, as the Laboratory's operating contractor, has a major, day-to-day role in minimizing fire-related risks. The issue of fire protection at Los Alamos is more than theoretical. In May 2000, the 'Cerro Grande' fire burned about 43,000 acres, including 7,700 acres of Laboratory property. Due to the risk posed by fire to the Laboratory's facilities, workforce, and surrounding communities, we initiated this audit to determine whether pre-existing fire protection deficiencies had been addressed. Our review disclosed that LANS had not resolved many of the fire protection deficiencies that had been identified in early 2006: (1) Of the 296 pre-existing deficiencies we selected for audit, 174 (59 percent) had not been corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating personnel from the second floor. Perhaps most serious, our testing revealed that a number of deficiencies were formally closed even though actual corrective action had not been completed. Notably, we observed that action had not been taken to resolve a recommendation to replace a fire alarm panel found to be unreliable. After the walk-down was conducted but prior to contract transition, the former contractor closed the recommendation in its action tracking database even though the panel had not been replaced. The walk-down team had categorized the fire alarm system as requiring replacement since it had been modified many times, was old and obsolete, and had very limited available spare parts. In fact, the walk-down team concluded that the panel 'must be considered to be unreliable and should have a very high priority for replacement'.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pressure Shell Approach to Integrated Environmental Protection

The next generation of exploration mission human systems will require environmental protection such as radiation protection that is effective and efficient. In order to continue human exploration, habitat systems will require special shells to protect astronauts from hostile environments. The Pressure Shell Approach to integrated environmental (radiation) protection is a multi-layer shell that can be used for multifunctional environmental protection. Self-healing, self-repairing nano technologies and sensors are incorporated into the shell. This shell consists of multiple layers that can be tailored for specific environmental protection needs. Mainly, this innovation focuses on protecting crew from exposure to micrometeorites, thermal, solar flares, and galactic cosmic ray (GCR) radiation. The Pressure Shell Approach consists of a micrometeoroid and secondary ejecta protection layer; a thin, composite shell placed in between two layers that is non-structural; an open cavity layer that can be filled with water, regolith, or polyethylene foam; a thicker composite shell that is a structural load bearing that is placed between two layers; and a bladder coating on the interior composite shell. This multi-layer shell creates an effective radiation protection system. Most of its layers can be designed with the materials necessary for specific environments. In situ materials such as water or regolith can be added to the shell design for supplemental radiation protection.

Kennedy, Kriss J.↗

Next Steps in Planetary Protection for Human Spaceflight

Planetary protection is defined as: a) the prevention of contamination of extraterrestrial bodies by terrestrial microorganisms, and b) biohazard containment of returned samples from bodies in the Solar System that could harbor life.1 While the majority of interplanetary missions to date have involved robotic exploration, future missions will include human explorers. Current planetary protection requirements do not address the unique challenges associated with human exploration. The purpose of this abstract is to review planetary protection efforts for crewed missions and provide a forward plan for implementing them at the systems level. Article IX of the UN Outer Space Treaty of 1967 provides the definition of planetary protection, outlined above.1 COSPAR holds the international standard in line with this treaty2, while NASA's Planetary Protection Policy (NPD 8020.7G) outlines the U.S. implementation of the COSPAR standard. 3;4 NPI 8020.7 groups future human spaceflight planetary protection studies as follows: 1) microbial monitoring, 2) contamination mitigation and control, and 3) environmental effects. Additionally, a NPI 8020.7 outlines a five-step plan for forward work: 1) a literature review, 2) community inputs, 3) completion of recommended studies, 4) developing a draft NPR, and 5) implementation with NASA teams. The literature review was published in 2016.5 Inputs from the community were gathered at the Planetary Protection Knowledge Gaps for Human Extraterrestrial Missions, held in 2015.6 Johnson and Race (2016) outlined notional requirements and prioritized studies needed before final requirements can be produced. This prior work sets the stage for completing the necessary studies and finalizing planetary protection requirements for human spaceflight. We propose a continuation of the systems engineering approach adopted thus far. The challenges associated with the implementation of notional requirements will be quantified in detailed discussions with internal stakeholders. The status and results of high-priority studies that have been completed since 2016 or are ongoing will be incorporated into discussions with stakeholders. In this way, we plan to bridge the gap between the science behind planetary protection and the engineering development that will implement it, allowing finalized planetary protection requirements to be developed for future human space missions.

Mitchell, Julie↗

Planetary Protection Lunar Policy: A Case Study in Balancing COSPAR Guidelines, Scientific Consensus, NASA Policy, and Mission Implementation

With the increase of missions to the Earth’s Moon over the next decade, NASA initiated an assessment and review of the policy and protection of Earth’s Moon to enable scientific exploration. The assessment involved gathering scientific consensus regarding the Earth’s Moon and proposed mission operations considering an understanding of the desired science needs for the Moon. This process involved seeking advice from the National Academies of Science, Engineering, and Medicine’s (NASEM) Committee on Planetary Protection, engagement with the Committee on Space Research (COSPAR) Planetary Protection Panel (PPP), and consultation within NASA. To begin this process, NASA issued a NASA Interim Directive (NID) 8715.128 entitled, “Planetary Protection Categorization for Robotic and Crewed Missions to the Earth’s Moon” in July of 2019. This NID defined sensitive regions (e.g., permanently shadowed regions) on the Moon and required reporting on missions to these sensitive areas. Meanwhile, a NASEM study on the impact of human activities on lunar polar volatiles and the scientific value of protecting the surface and subsurface regions of the Earth’s Moon from organic and biological contamination was initiated. This resulted in a NASEM report entitled, “Planetary Protection for the Study of Lunar Volatiles” which enabled further dialogue within NASA and with COSPAR. COSPAR PPP then leveraged this scientific consensus along with multi-agency input to develop an updated COSPAR Policy on Planetary Protection in June 2021 resulting in updated mission categorizations for Earth’s Moon (existing Category II for orbiters, and new categories IIa and IIb for landed missions). NASA then updated its current planetary protection policy to apply directly to NASA and NASA partnered missions in NASA Procedural Requirements (NPR) 8715.24 entitled, “Planetary Protection Provisions for Robotic Extraterrestrial Missions”. Along with the policy update NASA’s Office of Planetary Protection has worked with mission and programmatic teams to streamline reporting requirements to a simplified checkbox and fill-in-the-blank type of template. Throughout the abovementioned process, open and transparent communication between the policy makers and implementers was essential to ensure a balance with the updated policy, scientific intent, and practicality for each mission to be responsive and achieve mission success, including Artemis I and each of its secondary payloads, Gateway, CAPSTONE and Lunar Trailblazer.

James Benardini↗

Planetary Protection Technologies: Technical Challenges for Mars Exploration

The search for life in the solar system, using either in situ analysis or sample return, brings with it special technical challenges in the area of planetary protection. Planetary protection (PP) requires planetary explorers to preserve biological and organic conditions for future exploration and to protect the Earth from potential extraterrestrial contamination that could occur as a result of sample return to the Earth-Moon system. In view of the exploration plans before us, the NASA Solar System Exploration Program Roadmap published in May 2003 identified planetary protection as one of 13 technologies for "high priority technology investments." Recent discoveries at Mars and Jupiter, coupled with new policies, have made this planning for planetary protection technology particularly challenging and relevant.New missions to Mars have been formulated, which present significantly greater forward contamination potential. New policies, including the introduction by COSPAR of a Category IVc for planetary protection, have been adopted by COSPAR in response. Some missions may not be feasible without the introduction of new planetary protection technologies. Other missions may be technically possible but planetary protection requirements may be so costly to implement with current technology that they are not affordable. A strategic investment strategy will be needed to focus on technology investments designed to enable future missions and reduce the costs of future missions. This presentation will describe some of the potential technological pathways that may be most protective.

planetary protections↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗