Search NASA⌕ Search

SEARCH · Search NASA

Results for “PUMPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Investigation of heat pump technologies for high-temperature applications above 250 °C

This paper examines heat pump (HP) technologies to achieve heat supply temperatures above 250 °C, referred to as ultra-high-temperature heat pump (UHTHP). UHTHP, as a low-carbon heat delivery and heat augmentation technology, can offer an alternative to traditional combustion heating for decarbonizing high-temperature industrial processes. However, the heat supply temperature of over 250 °C surpasses the temperature range typically covered in the high-temperature HP literature and existing capabilities of commercial HP systems. This paper reviews HP technologies with the potential to evolve into UHTHP. Additionally, UHTHP studies in the literature are analyzed to compare the pros, cons, and technical potentials of various HPs using different thermodynamic cycles and fluids. Furthermore, we then pinpoint the technical gaps and challenges that have hindered widespread adoption of UHTHP in industry, explore potential improvements and solutions, and discuss the feasibility. Current efforts aim to lay the ground for future research, development, and commercial deployment for UHTHP.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Ductless Heat Pump Program

The Verde Ductless Heat Pump (DHP) Program expanded access to high-efficiency electric heating and cooling technologies for households in priority communities within the Portland Metro area. Funded by the U.S. Department of Energy’s Building Technologies Office (DE-EE0010132), the program combined residential ductless heat pump deployment with community-based outreach, participant support, contractor partnerships, and system development to improve program delivery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Investigation of a thermocapacitive cycle by aqueous supercapacitors for multifunctional heat pump and energy storage

Thermocapacitive cycles are promising thermal and energy storage cycles using supercapacitors, which can achieve thermal efficiencies over 50% of the Carnot limit. There is a lack of work investigating the use of thermocapacitive effects in practical heat pumps. Here, this paper explores the design of thermocapacitive cells with higher temperature changes to be better suited for heat pumping applications. To evaluate the cell designs on temperature changes, pouch type cells are prototyped and modeled, and tested using a micro-calorimeter. A peak adiabatic temperature span of a LiCl aqueous cell is 2.7 °C. By arranging the cells in a cascade manner, the projected adiabatic temperature span can reach up to 12 °C with a heating density of 15 kW m −3 and an energy storage density of 0.83 kWh m −3 . Models predict that this could be increased to 30 °C and 1.65 kWh m −3 through improvements to cell capacitance and thermopower. Incorporating the energy storage capabilities into heating and cooling devices can be beneficial to building thermal management as energy storage becomes increasingly important for energy system integration.

25 ENERGY STORAGE↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercialization of Pumped Storage Hydropower Technologies

Argonne National Laboratory and the National Laboratory of the Rockies were tasked by the U.S. Department of Energy’s Water Power Technology Office (WPTO) to conduct the Commercialization of Pumped Storage Hydropower Technologies study to investigate commercialization challenges faced by developers of pumped storage hydropower (PSH) projects and technologies by going beyond literature review to gather direct industry insights, lessons learned and best practices from interviews and webinars with industry specialists to create this report for PSH stakeholders and the general public. Researchers explored key challenges faced by PSH developers and innovators seeking to commercialize new technologies to improve PSH design, siting, construction, and operations. Along with highlighting challenges, the study sought to identify the best practices in developing and deploying new PSH projects and innovations. This report is designed to present insights, lessons learned, and best practices relevant to those with an interest in highlighting, informing, or advancing these PSH commercialization efforts. Along with highlighting challenges and best practices, the study sought to identify avenues by which DOE and national laboratories can help support and streamline PSH commercialization and project development processes.

13 HYDRO ENERGY↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

Quantization of the Higher Berry Curvature and the Higher Thouless Pump

Here, we show that for families of 1d lattice systems in an invertible phase, the cohomology class of the higher Berry curvature can be refined to an integral degree-3 class on the parameter space. Similarly, for families of U(1)-invariant 2d lattice systems in an invertible phase, the higher Thouless pump can be refined to an integral degree-2 class on the parameter space. We show that the 2d Thouless pump can be identified with an excess Berry curvature of a flux insertion.

97 MATHEMATICS AND COMPUTING↗

Logical approach to tritium vacuum pump selection for fusion applications

Vacuum pumps have been used for tritium processing since the 1940s following the isolation of pure tritium. The largest problem facing tritium vacuum pumps is the tritium radioactive decay. The beta particles, recoil energy, and subsequent radical formations are detrimental to most carbon-based materials. Carbon materials, such as plastics, elastomers, carbon fiber, activated carbon, etc., react with tritium to form methane and in the process strip material from the carbonbased material. Other reactions can be self-catalyzing, as is the case with nitrogen and tritium forming tritiated ammonia at room temperature and pressure. Tritium also readily isotopically exchanges with surface -OH groups, increasing the amount of protium in the gas stream while creating a tritium holdup on the surface. Metals are the preferred material when working with tritium, but tritium will permeate into and through almost all metals at some point. The entrapped tritium can decay inside the metal, creating local helium distortions that can impact the structural properties above and beyond the hydrogen embrittlement issue tritium can cause.

Angelette, Lucas M. [Savannah River National Labor↗

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗

Advected carbon younger than the sediment fuels microbial metabolism in a pumped deep aquifer

Ever deeper wells are drilled worldwide to pump potable groundwater. Recent studies argue that overpumping compresses clays and releases reactive dissolved organic carbon (DOC), which in turn drives a series of microbial reactions that affect groundwater potability including arsenic concentrations. Here, we use a novel method to measure the radiocarbon ages of microbial RNA to determine the source of reactive or metabolizable DOC and argue against the compression of clays as the sole source of carbon. We show that microbial RNA (5,230; 5,550; 6,250 yr; n = 3 wells), DOC (280-10,800 yr; n = 13), and methane (modern to 6,240 yr; n = 3), from an overpumped deep aquifer in Bangladesh are much younger than the overlying clay layers deposited during the Pleistocene over 12,000 years ago. Mass-balance indicates that at least half of the carbon incorporated into RNA has to come from reactive DOC or methane that is advected downward via vertical recharge. This metabolism of advected organic carbon could have implications for the quality of water pumped from deep aquifers.

Biological and medical sciences↗

Probing polarization-tunable sub-terahertz spin pumping in bimodal α-Fe 2 O 3 /Pt

Hematite (α-Fe 2 O 3 ) is an insulating antiferromagnet possessing a room temperature canted phase induced by the super-exchange Dzyaloshinskii-Moriya Interaction (DMI), resulting in enhanced spin pumping and spin transport over uniaxial antiferromagnets. In this work we resonantly excite the quasi-ferromagnetic (acoustic) and purely antiferromagnetic (optical) spin-dynamical modes in bulk and thin-film heterostructures of α-Fe 2 O 3 /Pt at room temperature, inducing inverse-spin-Hall-voltages up to 255 GHz. Following recent measurements of optical-mode spin-pumping in α-Fe 2 O 3 , we observe a novel and exotic microwave polarization mapping along with amplified spin-charge conversion in the optical branch and discuss the implications of layer thickness on acoustic and optical spin-modes. The results provide a deeper understanding of spin-wave selection rules for canted antiferromagnets and their potential use in nanoscale terahertz spintronics.

interfaces↗

Spin pumping driven by magnon-polaritons in a ferromagnet–coplanar superconducting resonator hybrid system

We demonstrate spin pumping driven by a strongly coupled magnon-photon system using a ferromagnet-coplanar superconducting resonator hybrid system at 1.4 K. Electrical readout via the inverse spin-Hall effect reveals characteristic coupling features, including mode splitting and linewidth broadening, demonstrating the electrical detection of strongly coupled microwave photons and magnons. The microwave magnon-photon coupling strength obtained by combined spin pumping and inverse spin-Hall effect measurements is compared to microwave transmission experiments. Here, microwave power-dependent measurements reveal a decrease in the coupling strength with increasing microwave power alongside the onset of nonlinearities of the superconducting resonator above a critical microwave power threshold.

Wagle, Dinesh [University of Delaware, Newark, DE ↗