Search NASA⌕ Search

SEARCH · Search NASA

Results for “PUMPS, FUEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Understanding NBI heating and fueling in LTX-β tokamak

My work on the contract DE-SC=0023274 (July, 2022 - July, 2025) was focused on understanding the plasma fueling by NBI. On Dec. 1998 with Sergei Krasheninnikov (UCSD, San Diego, CA) we initiated the Li Wall Fusion (LiWFusion) as a new concept of magnetic fusion [1]. The new 1 2 plasma 3 4 5 6 2.1 Overview of rate coefficients, mean-free paths λH0 , and diffusions coefficients 6 2. GSV code for ⟨σv⟩ analysis of NBI fueling concept was a reaction of the lack of luck of tokamak fusion with QDT = 1 on TFTR and JET. We recognized the edge plasma cooling by recycling to be the route reason of the tokamak problems on the way to burning plasma. LiWFusion relies on plasma pumping by a lithium layer on the inner walls of the plasma chamber, combined with the plasma heating and fueling by the Neutral Beam Injection (NBI). These two innovations eliminate the route problem of the tokmak fusion. The concept became theoretically mature in 2006. In 2012, the technology of continuously Flowing Liquid Lithium (24/7-FLiLi) was invented by me for the future implementations of the LWFusion concept. At the same time, my every presentation on LiWFusion to International Symposium on Lithium Applications since 2010 was objected by some person with words “Everybody since the 1970s knows that plasma fueling by NBI is impossible”. I dropped the name of the author of this objection and ignored his views. My work on the current grant on NBI fueling of LTX-β not only clarified the issue but resolved it in an astonishing way. The NBI fueling was fully understood (thus humiliating the current dogmatic fusion community). The new future of LTX-β dedicated for decades to Li in tokamaks, as well as of the entire magnetic fusion program was envisioned, in sharp contrast with the fallure of OFES in the post-TFTR era of 21st century.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous enhancement of tritium burn efficiency and fusion power with low-tritium spin-polarized fuel

This study demonstrates that using spin-polarized deuterium-tritium (D-T) fuel with more deuterium than tritium can increase tritium burn efficiency (TBE) by at least an order of magnitude without compromising fusion power output, compared to unpolarized fuel. Although previous studies show that a low tritium fraction can enhance TBE, this strategy resulted in reduced fusion power density. The surprising improvement in TBE at fixed power reported here is due to the TBE increasing nonlinearly with decreasing tritium fraction but the fusion power density increasing roughly linearly with D-T cross section. A study is performed for an ARC-like tokamak producing 481 MW of fusion power with unpolarized 53:47 D-T fuel, finding the minimum startup tritium inventory (I startup,min ) is 0.69 kg. By spin-polarizing half of the fuel and using a 60:40 D-T mix, I startup,min is reduced to 0.08 kg, and fully spin-polarizing the fuel with a 63:37 D-T mix further reduces I startup,min to 0.03 kg. Some ARC-like scenarios are predicted to achieve plasma ignition with relatively modest spin polarization. These findings indicate that, with advancements in helium divertor pumping efficiency, TBE values of approximately 10%–40% could be achieved using low-tritium-fraction and spin-polarized fuel with minimal power loss. This would dramatically lower tritium startup inventory requirements and reduce the amount of on-site tritium. More generally than just for spin-polarized fuels, increased plasma performance can be used to increase TBE. This strongly motivates the development of spin-polarized fuels and low-tritium-fraction operation for burning plasmas.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and mate-rial selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Ox-ygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the salt, and is additionally used to protect a 316L stainless steel pump reservoir. The pump wetted components are made of Inconel 625, and it features a carbon ring seal developed by Flows-erve flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. This research showcases a promising design for use in the CSP Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys. Further work will further characterize the pump by performance & cycle testing in molten salt at higher temperatures.

14 SOLAR ENERGY↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

High Temperature Ternary Chloride Molten Salt Pump

A ternary chloride (MgCl2-NaCl-KCl) molten salt pump has been developed to operate up to 720°C. The design is the result of a thermal, structural and material study of critical components. The vertical overhung pump incorporates first of a kind salt-wetted hydrodynamic bearings. Several bearing material pairings were tested which include: colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Oxygen Fuel (HVOF) coating. The coating withstands the corrosion effects of the molten salt, and is also used to protect a 316L stainless steel pump reservoir. The pump bowl assembly components are made of Inconel 625. A Nitrogen flushed carbon ring seal is used to keep salt vapors from interacting with external ambient air. Preliminary testing shows a promising pump design for use in the Concentrating Solar Power Gen 3 systems and sets the ground for further development of the HybrimetTM NiWC3b as a competitive alternative to available superalloys.

Handy-Cardenas, Lewis (ORCID:0009000744006972)↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Acoustic mapping by picosecond ultrasonics for elastic property measurement: Experimental demonstration on a TRISO fuel compact

Picosecond ultrasonics has been demonstrated on a tristructural isotropic (TRISO) fuel compact to measure the elastic properties of each compact layer. This technique utilizes an ultrashort pump laser pulse to excite vibrations in a gold transducer film covering the surface of each component and a second probe laser pulse to record the resulting acoustic strain induced change in optical reflectance. From the damping of this film vibration, the acoustic reflection coefficient, which couples the elastic properties of the transducer film and the sample, can be obtained, enabling a calculation of the sample’s acoustic velocity and elastic modulus. Overall, results obtained from this method are consistent with known values of elastic moduli, namely that the SiC coating is the stiffest component of the compact while the carbonaceous matrix is the most compliant. Nanoindentation was conducted as a benchmark technique on the same sample and shows satisfactory agreement with the results of picosecond ultrasonics. Compared to other methods like nanoindentation, picosecond ultrasonics is multimodal with a capability of measuring several key properties simultaneously and has potentials to be coupled into optical fibers for remote sensing. Thus, these demonstration measurements reveal the methodology to be a promising candidate for in-situ and high-throughput optical characterizations of nuclear materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as an Innovative Energy Storage Technology for Fossil-Integrated Systems

Pumped-storage hydropower (PSH) provides around 95% of all utility-scale energy storage in the U.S. and globally. Additional deployment of PSH is hampered by excessively long permitting and commissioning requirements and is constrained to locations for which natural topography provides suitable elevation relief between the upper and lower reservoirs (the ΔH challenge). The purpose of this research was to evaluate Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as a means to solve the ΔH challenge and initiate the commercialization pathway for a promising new energy storage technology. Four primary tasks were conducted: Screening and ranking of candidate sites for project development; multiphase reservoir modeling to evaluate mine performance; techno-economic analysis and preliminary designs for PSH-AUM systems integrated with fossil-fuel power units; and stakeholder engagement to identify pathways to commercialization of this new technology. Key results were achieved in each of the four primary tasks. Candidate site screening determined that nearly 10,000 underground mines were spatially locatable, of which more than 100 sites appear suitable for integration with existing fossil power plants that are expected to remain in longer-term operation. Mine reservoir models were developed using PNNL’s STOMP simulator and parameterized using candidate site data to evaluate interactions with the surrounding groundwater system and confirm the potential for some mines to accommodate inflows and outflows on the order of 100 m3/s over 8-hour durations (1.6 GWh system) without excessive aqueous pressures. Techno-economic analysis resulted in a project cost optimization scheme to identify key sensitivities and the development of preliminary designs that can minimize overall costs of deployment. Finally, stakeholder engagement with industry, state government, and local economic development leaders confirmed the viability of PSH-AUM as a promising new technology. Our Phase I project results suggest that PSH-AUM technology has a domestic market potential on the order of $100+ Billion with ample space for technology development to commercialization within the next decade.

13 HYDRO ENERGY↗

Optimal pumping schedule with high-viscosity gel for uniform distribution of proppant in unconventional reservoirs

Hydrocarbon recovery from a hydraulic-fractured unconventional reservoir can be enhanced by replacing slickwater with non-Newtonian high-viscosity gel as a fracturing fluid. However, in the literature, the role of gel rheology on hydrocarbon production from a fractured reservoir is not very well understood. This lack of understanding makes it difficult for the industry to choose appropriate viscosity parameters of fracturing gels. Motivated by these limitations, first, we have developed a high-fidelity model of non-Newtonian fluid flow to simulate fracture propagation, fluid leak-off, and gel flowback processes to predict the oil production from a hydraulic fractured reservoir. Simulation results of the high-fidelity model show how fracture geometry, formation damage, and gel cleanup process varies with the fracturing fluid rheology. Therefore, the developed model is used to understand the effect of gel rheology on hydrocarbon production via a sensitivity analysis, which provides a set of rheological parameters that maximize the cumulative amount of oil production. Finally, utilizing this optimal high-viscosity gel, a model predictive controller is designed to obtain an optimal pumping schedule necessary for producing a target fracture geometry and proppant concentration. The closed-loop simulation results demonstrate that the obtained pumping schedule successfully achieved the desired fracture geometry and proppant concentration at the end of pumping, leading to the maximum oil production from an unconventional reservoir.

13 HYDRO ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Combustion characteristics of diisopropoxymethane, a low-reactivity oxymethylene ether

Oxymethylene ethers (OMEs) have been studied for use as low-sooting diesel fuel additives or substitutes; very little literature discusses OMEs as spark-ignition (SI) fuels due to their typically high cetane numbers. In this work, a lower-reactivity, branched OME, diisopropoxymethane (DIPM), is evaluated to determine its effectiveness as a spark-ignition fuel, as it is the lowest-reactivity OME (as determined by Indicated Cetane Number) thus far evaluated in the literature. DIPM is synthesized in-house via acetalization from isopropanol (iPrOH) and trioxane using standard OME production practices. DIPM was then tested in a rapid compression machine (RCM) for autoignition and spark ignition characteristics, and in a modified CFR engine to determine effective octane numbers. In the RCM, an autoignition temperature sweep was performed at stoichiometric conditions from 1000/T = 1.7 - 1.0, at 5:1 inert ratio (comparable to approximately 25% EGR), where it was found that DIPM has ignition delay times 5–10x faster than isooctane and displays NTC ignition behavior. Blends with iPrOH indicate that reactivity can be matched with isooctane with low blend ratios of iPrOH in DIPM. Flame speeds were tested with a laser spark for ignition in the RCM, where the flame speed of DIPM and isooctane is determined to be comparable at engine relevant conditions. In the CFR engine, effective RON and MON based on pressure trace frequency domain measurements were determined for DIPM and a 15 vol% iPrOH in DIPM blend. Neat DIPM has (R+M)/2 = 59 and a negative sensitivity of S = -18, consistent with its NTC behavior and higher reactivity. Furthermore the DIPM/iPrOH blend has positive sensitivity and a pump-gasoline range (R+M)/2 = 89.3. DIPM on its own is unlikely to be an effective SI fuel, however, when blended with iPrOH as an ON booster, it may be a promising SI candidate fuel.

09 BIOMASS FUELS↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically driven phase transformation for high-efficiency heat pumping

To reduce energy consumption and improve energy utilization in space conditioning, advanced heat pumping technologies are needed. The chemical looping heat pump (CLHP) is a promising thermodynamic cycle that has theoretically shown the potential to achieve a cooling coefficient of performance (COP c ) increase of over 20% relative to conventional vapor compression systems. In this paper, the key process of the CLHP is experimentally demonstrated, and the system performance and non-ideal behavior are predicted using the component-level models. The results show the feasibility of electrochemical phase change of a working fluid; the peak COP c was 7.64 with a cooling capacity of 3.6 mW (cooling density of 2.57 W m -2 ) at both sink and source temperature of 23°C based on laboratory experiments. The COP c can theoretically reach up to 13 at a temperature lift of 15°C as long as an electrochemical cell can achieve a greater degree of conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging automotive fuel cells can supply zero-emission peak power in the near-term

An increasingly decarbonized yet resilient power grid requires the corresponding build-out of dispatchable zero-emission resources to supply peak power. However, there is a recognized dearth of solutions which can serve multi-day peak demand events both cost-effectively and with near-term deployability. Here, we find that pairing low-cost automotive fuel cells with hydrogen storage in salt caverns can serve as a peaker plant at less than 500 US$/kW at present, a fraction of the cost of conventional fossil fuel-fired peakers. We demonstrate the peaker’s value for long duration storage by comparing it with pumped hydro and assessing its profitability within Texas’ energy-only market region. Although deployment of these peakers is constrained by the presence of salt caverns, we show that a number of sites in the United States and Europe are endowed with suitable salt formations, while utilizing hydrogen storage in pressurized containers could form a location-agnostic peak power solution.

25 ENERGY STORAGE↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗