At least 145 records · Page 8

Electrolyzers in the System Advisor Model (SAM): A Techno-Economic Potential Study

A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.

08 HYDROGEN↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Based Predictive Control for Frequency Support in Multi-port Autonomous Reconfigurable Solar Plants

Primary frequency support functionality can be an added advantage for any new grid integrated power electronics resource. With increased penetration of power electronics resources, inertial and primary frequency response capabilities are decreasing. In this research paper, an advanced model-based predictive control (MBPC) algorithm for providing frequency support to a new topology of integrated photovoltaic(PV), batterybased energy storage systems (ESS), and high-voltage direct current (HV dc) systems called multi-port autonomus reconfigurable solar (MARS) plants is based on the synchronverter-based control. The simulation of MARS-HV dc system with proposed control strategy is simulated and validated for MARS connected to low short circuit ratio (SCR) grids in PSCAD/EMTDC simulation environment. The control algorithm proposed showcases better performance in terms of frequency nadir improvement and frequency steady state improvemnt with respect to no frequency control.

Marthi, Phani Ratna Vanamali↗

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

Optimizing an Integrated Renewable-Electrolysis System

Hydrogen is a versatile energy carrier that is used in a wide variety of chemical and industrial processes. Producing hydrogen using electrolysis can enable integration of multiple sectors including electricity, heating, and industrial sectors; however, the cost of producing hydrogen from electrolysis remains a challenge for encouraging greater adoption. With growing amounts of renewable generation on the California grid, there is downward pressure on wholesale electricity prices, particularly during the afternoon from photovoltaics (PV). These lower, or even potentially negative prices, challenge the business cases for new and existing PV plants. In addition, as the grid transitions to less flexible generation, there is greater need for system flexibility. To help improve the economics for both solar PV and hydrogen production using electrolyzers, we explore the benefit of combining PV and electrolysis systems. The optimal breakeven hydrogen production cost for six unique market participation configurations is calculated at six candidate locations where PV is already installed. The six market configurations include islanded, separated, retail, net energy metering (NEM), hybrid retail/wholesale and wholesale. Using the Revenue Operation and Device Optimization Model (RODeO) model, the optimal breakeven hydrogen price over the lifetime of the equipment is calculated. The cost includes production, storage, and compression in preparation for gaseous delivery trucks. Revenue streams include the sale of hydrogen, low carbon fuel standard (LCFS) credits, renewable electricity sold to the grid, and Renewable Energy Credits (REC). The costs included are the electricity costs, capital and fixed operation and maintenance cost (FOM) for the electrolyzer, PV, and storage and compression systems as well as taxes and financing costs. In addition, cost reductions are achieved through retail and wholesale rate optimization, by which electricity is purchased at the lowest price and sold, if possible, at the highest price. For all locations, the breakeven hydrogen production cost results show that, in the order of decreasing cost, the system configurations are islanded (highest), separated, NEM, retail, hybrid retail/wholesale, and wholesale (lowest). The resulting system design balances between the capital and maintenance cost components, the operation costs (i.e., electricity costs) and the additional market revenues. The integration of solar PV and electrolysis is shown to provide a mutually beneficial relationship. For PV, integration with electrolysis offers the potential to hedge against wholesale market price volatility, and integration with electrolysis may offer the potential to defer or avoid transmission investment to deliver power to the point-of-use and instead use it on-site. When compared with SMR without considering any renewable hydrogen premiums, this study finds that PV + Electrolysis systems with current costs are likely not competitive; however, with cost reductions for electrolysis equipment consistent with DOE projections, it was found that systems with wholesale market access would be competitive, largely on account of both low capital costs and low-cost electricity. The electrolysis units can provide greater flexibility than is required based on retail rate optimization, so there is an opportunity for a utility or CAISO to increase system flexibility with PV + Electrolysis systems in return for commensurate compensation. In this way, there are potentially several solutions that fall between the hybrid configuration and the wholesale configuration that could provide sufficient compensation for a PV + Electrolysis unit to compete with SMR while also providing greater flexibility to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VOLTTRON™ Agent Development for Enabling Reactive Power Support of Non-Utility DERs by Integrating Transactive Energy Approach

To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.

Kritprajun, Paychuda↗

Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment

Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sample IEEE123 Bus system for OEDI SI

Time series load and PV data from an IEEE123 bus system. An example electrical system, named the OEDI SI feeder, is used to test the workflow in a co-simulation. The system used is the IEEE123 test system, which is a well studied test system (see link below to IEEE PES Test Feeder), but some modifications were made to it to add some solar power modules and measurements on the system. The aim of this project is to create an easy-to-use platform where various types of analytics can be performed on a wide range of electrical grid datasets. The aim is to establish an open-source library of algorithms that universities, national labs and other developers can contribute to which can be used on both open-source and proprietary grid data to improve the analysis of electrical distribution systems for the grid modeling community. OEDI Systems Integration (SI) is a grid algorithms and data analytics API created to standardize how data is sent between different modules that are run as part of a co-simulation. The readme file included in the S3 bucket provides information about the directory structure and how to use the algorithms. The sensors.json file is used to define the measurement locations.

123 bus↗

Power Electronic Hardware-in-the-Loop (PE-HIL): Testing Individual Controllers in Large-Scale Power Electronics Systems

Large power electronics systems like multi-port autonomous reconfigurable solar power plant (MARS) are increasingly being researched upon to integrate emerging energy sources. MARS connects photovoltaic (PV) systems and energy storage systems (ESSs) to high-voltage direct current (HVdc) links/grids and high-voltage alternating current (ac) transmission grids. As these large power electronics systems incorporate complex hierarchical control systems that are close-by and communicate fast, the control systems require an unique power electronic hardware-in-the-loop (PE-HIL) real-time architecture to evaluate individual controllers. In this paper, a PE-HIL real-time architecture is proposed to evaluate one of the hundreds to thousands of digital signal processors (DSPs) that are a part of the complex hierarchical control system. The DSP connects to a central processing unit (CPU) and a field programmable gate array (FPGA) that form a part of the upper levels of the control system. The DSP is part of the lower level of the control system. The proposed PE-HIL architecture is tested and evaluated. Preliminary test results are presented to showcase the concept.

Debnath, Suman↗

Coupled-DC Module-Based Photovoltaic System With Power Mismatch-Tolerated Modulation

Here, this article presents a coupled-DC power module-based cascaded multilevel converter integrating utility-scale photovoltaic (PV) generations (coupled-DC-link power module (CDPM)-PV). CDPM-PV inherits merits such as modular structure, distributed maximum power point tracking (MPPT), direct distribution grid access, from cascaded H-bridge-based PV (CHB-PV) system. But, it supplies more flexible power routes than CHB-PV, through coupling different DC-links. Power routes are intended for enlarging the entire operating range including conditions of active power mismatch arising from nonideal elements such as partial shading and parameter variations. The system construction with its self-balancing principle is first introduced. Switching states for different operating regions are then derived based on the principle of easing implementation. Based on these, a modulation strategy including initial switching pattern selection and coordinated power routing is proposed to allow module-mismatches. Operating ranges are also analyzed and compared with conventional CHB-PV. Simulation results of a 3-MW/13.8-kV system developed in MATLAB/Simulink platform, and experiment results based on a 2.4-kW/311-V setup are presented and have demonstrated that the CDPM-PV topology with proposed modulation strategy can not only ride through a larger range of module mismatches, but also improve solar power utilization and system efficiency owing to noncompromised MPPT.

14 SOLAR ENERGY↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

Fact sheet describes how the Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid to ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

battery storage↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Preparing Distribution Utilities for Utility-Scale Storage and Electric Vehicles: A Novel Analytical Framework

Emerging distributed energy resources (DERs)—such as solar photovoltaics (PV), battery energy storage systems (BESS), and electric vehicles (EVs)—are expected to increase substantially in India in the coming years following policy-driven targets of the Government of India to modernize its electricity system, reduce greenhouse gas emissions (GHGs), and improve air quality. These emerging technologies can pose challenges to distribution utilities, forcing overhauls in planning and operational practices. They can also create challenges in power system infrastructure planning and cause more frequent system operational violations (e.g., network voltage bounds and loading thresholds) if not properly integrated. The impacts on the localized power distribution grid from these emerging technologies manifest in increased infrastructure investments and erratic shifts in demand patterns. These impacts are not yet well understood, and analytic solutions are not readily available. To address these challenges, the National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL), developed an advanced power distribution system impact analysis framework of BRPL’s distribution system. This framework helps analyze the readiness of the power distribution network to accommodate emerging technologies and the potential opportunities they might introduce. The framework has been predominantly set up to evaluate distributed PV, BESS, and EVs. In this collaboration between NREL and BRPL, we developed and evaluated the framework on two distribution feeders in the BRPL territory for various scenarios of BESS and EVs. BESS are evaluated for their effectiveness on the grid to mitigate present and future feeder overloading scenarios, and they are subsequently analyzed for their costs compared to the costs of traditional upgradation measures. Scenarios include assessing the effects of EV density on grid infrastructure upgrades and interlinking EV management with BESS integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗