Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Space Station Freedom photovoltaic power module design status

Electric power generation for the Space Station Freedom will be provided by four photovoltaic (PV) power modules using silicon solar cells during phase I operation. Each PV power module requires two solar arrays with 32,800 solar cells generating 18.75 kW of dc power for a total of 75 kW. A portion of this power will be stored in nickel-hydrogen batteries for use during eclipse, and the balance will be processed and converted to 20 kHz ac power for distribution to end users through the power management and distribution system. The design incorporates an optimized thermal control system, pointing and tracking provision with the application of gimbals, and the use of orbital replacement units to achieve modularization. The design status of the PV power module, as derived from major trade studies, is discussed at hardware levels ranging from component to system. Details of the design are presented where appropriate.

Jimenez, Amador P.↗

Q1-2025 Solar Photovoltaic System Cost Benchmarks

The U.S. Department of Energy’s solar office and its national laboratory partners analyze cost data for U.S. solar photovoltaic systems to develop cost benchmarks to measure progress toward goals and guide research and development programs. The cost data is available in an Excel spreadsheet model that can be downloaded here.

14 SOLAR ENERGY↗

Initial Results from the Floating Potential Measurement Unit aboard the International Space Station

The Floating Potential Measurement Unit (FPMU) is a multi-probe package designed to measure the floating potential of the 1nternational Space Station (ISS) as well as the density and temperature of the local ionospheric plasma environment. The role oj the FPMU is to provide direct measurements of ISS spacecraft charging as continuing construction leads to dramatic changes in ISS size and configuration. FPMU data are used for refinement and validation of the ISS spacecraft charging models used to evaluate the severity and frequency of occurrence of ISS charging hazards. The FPMU data and the models are also used to evaluate the effectiveness of proposed hazard controls. The FPMU consists of four probes: a floating potential probe, two Langmuir probes. and a plasma impedance probe. These probes measure the floating potential of the ISS, plasma density, and electron temperature. Redundant measurements using different probes support data validation by inter-probe comparisons. The FPMU was installed by ISS crewmembers, during an ExtraVehicular Activity, on the starboard (Sl) truss of the ISS in early August 2006, when the ISS incorporated only one 160V US photovoltaic (PV) array module. The first data campaign began a few hours after installation and continued for over five days. Additional data campaigns were completed in 2007 after a second 160V US PV array module was added to the ISS. This paper discusses the general performance characteristics of the FPMU as integrated on ISS, the functional performance of each probe, the charging behavior of the ISS before and after the addition of a second 160V US PV array module, and initial results from model comparisons.

Wright, Kenneth H., Jr.↗

Photovoltaic power modules for NASA's manned space station

The capability and the safety of manned spacecraft are largely dependent upon reliable electric power systems. Two similar space power systems able to survive the low Earth orbit environment, are being considered for NASA's Manned Space Station (SS), scheduled to begin operation in the mid 1990's. The Space Station Electric Power System (EPS) is composed of Photovoltaic (PV) Power Modules, Solar Dynamic (SD) Power Modules, and the Power Management and Distribution (PMAD) System. One EPS configuration will deliver 37.5 kW of PV based, utility grade, ac power to SS users. A second 75 kWe PV based EPS option is also being considered for SS deployment. The two EPS options utilize common modules and differ only in the total number of PV Power Modules used. Each PV Power Module supplies 18.75 kWe of ac power and incorporates its own energy storage and thermal control. The general requirements and the current preliminary design configuration of the Space Station PV Power Modules are examined.

Tatro, Charles A.↗

Photovoltaic power modules for NASA's manned Space Station

The capability and the safety of manned spacecraft are largely dependent upon reliable electric power systems. Two similar space power systems able to survive the low earth orbit environment, are being considered for NASA's Manned Space Station (SS), scheduled to begin operation in the mid 1990's. The Space Station Electric Power System (EPS) is composed of Photovoltaic (PV) Power Modules, Solar Dynamic (SD) Power Modules, and the Power Management and Distribution (PMAD) System. One EPS configuration will deliver 37.5 kW of PV based, utility grade, ac power to SS users. A second 75 kWe PV based EPS option is also being considered for SS deployment. The two EPS options utilize common modules and differ only in the total number of PV Power Modules used. Each PV Power Module supplies 18.75 kWe of ac power and incorporates its own energy storage and thermal control. The general requirements and the current preliminary design configuration of the Space Station PV Power Modules are examined.

Tatro, C. A.↗

Protoflight photovoltaic power module system-level tests in the space power facility

Work Package Four, which includes the NASA-Lewis and Rocketdyne, has selected an approach for the Space Station Freedom Photovoltaic (PV) Power Module flight certification that combines system level qualification and acceptance testing in the thermal vacuum environment: The protoflight vehicle approach. This approach maximizes ground test verification to assure system level performance and to minimize risk of on-orbit failures. The preliminary plans for system level thermal vacuum environmental testing of the protoflight PV Power Module in the NASA-Lewis Space Power Facility (SPF), are addressed. Details of the facility modifications to refurbish SPF, after 13 years of downtime, are briefly discussed. The results of an evaluation of the effectiveness of system level environmental testing in screening out incipient part and workmanship defects and unique failure modes are discussed. Preliminary test objectives, test hardware configurations, test support equipment, and operations are presented.

Rivera, Juan C.↗

Protoflight photovoltaic power module system-level tests in the Space Power Facility

Work Package Four, which includes the NASA-Lewis and Rocketdyne, has selected an approach for the Space Station Freedom Photovoltaic (PV) Power Module flight certification that combines system level qualification and acceptance testing in the thermal vacuum environment: the 'protoflight' vehicle approach. This approach maximizes ground test verification to assure system level performance and to minimize risk of on-orbit failures. The preliminary plans for system level thermal vacuum environmental testing of the protoflight PV Power Module in the NASA-Lewis Space Power Facility (SPF) are addressed. Details of the facility modifications to refurbish SPF, after 13 years of downtime, are briefly discussed. The results of an evaluation of the effectiveness of system level environmental testing in screening out incipient part and workmanship defects and unique failure modes are discussed. Preliminary test objectives, test hardware configurations, test support equipment, and operations, are presented.

Rivera, Juan C.↗

Electromagnetic Transient Simulation of Photovoltaic Inverter Using Implicit-Explicit Solver

This paper introduces the implementation of electromagnetic transient (EMT) simulations of a photovoltaic (PV) inverter module using the Implicit-Explicit (ImEx) solver in the Suite of Nonlinear and Differential/Algebraic Equation Solvers (SUNDIALS). This study demonstrates the effectiveness of the ImEx solver in overcoming the challenges inherent in simulating the complex dynamics of PV inverter modules. Furthermore, using SUNDIALS’ ImEx solver module ARKODE for EMT simulation automates key aspects of the process, such as numerical integration, providing substantial benefits including enhanced consistency, faster implementation, reduced human error, and the capability to handle the complexities of advanced numerical integration. By conducting comparative simulations with an implicit method used in commercial software, the research showcases the ImEx solver’s capability in achieving high accuracy and reliability. Results indicate that leveraging the ImEx approach significantly enhances modeling fidelity and reduces simulation setup times, offering a promising tool for the EMT analysis of PV inverter systems in power electronics-dominated power grids.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗

What Is a Polyolefin? A Critical Overview of Ethylene Copolymers Used as Solar Photovoltaic Module Encapsulants

In recent years, photovoltaic (PV) encapsulant films marketed as polyolefins (POs), more specifically as PO elastomers (POEs) and thermoplastic POs (TPOs), have gained significant market share and are projected to become the dominant encapsulation films by 2030. Relative to other industries, there are significant misconceptions about the term PO in the PV industry. Both in the scientific literature as well as in sales and advertising, the terms PO, POE, and TPO are often misused to describe the same type of material with comparable properties, while in reality these may each consist of separate material classes. This paper provides a comprehensive literature and market review, to showcase a broad range of PO and other ethylene copolymer encapsulants from recent studies, and discusses the materials' properties to clarify what constitutes a “polyolefin.” In addition, to promote a clearer comparison of encapsulant properties, we propose a two‐dimensional taxonomy to categorize polymers used in module manufacturing, including POs. In terms of improving the reliability of solar PV modules, PO‐based encapsulants have several advantages (including lower water uptake and ion diffusion), but might come with disadvantages too, such as a more complex processing and a higher sensitivity to the storage conditions and shelf life. All this might prospectively impact adhesion properties of the encapsulant to other materials' interfaces (glass, cells etc.) and end‐product quality. Because the track record of field‐deployed PV modules containing PO encapsulants is also limited, we hope to contribute to better material understanding and precision in communication in PV to secure quality.

14 SOLAR ENERGY↗

Extended Accelerated Stress Testing of Lamination-Free Edge-Sealed Photovoltaic Minimodules

Lamination-free minimodules are constructed with silicon solar cells between glass sheets and an edge seal of polyisobutylene and silicone. These samples are stressed using a repeated sequential testing sequence including ultraviolet-containing simulated solar spectrum light exposure at elevated temperature, damp heat, humidity freeze, and thermal cycling adapted from the International Electrotechnical Commission (IEC) TS 63209-2:2022. The minimodule performance throughout the stressing is characterized by flash testing and electroluminescence imaging. Results are compared to conventional laminated minimodules using the same type of solar cells. The lamination-free minimodules experience up to 8% power loss compared to roughly 3% for the laminated versions. However, those losses, dominated by current and fill factor, are caused by glass soiling and busbar ribbon separation on the cells. When glass is replaced and the stressed cells are contacted with probes bypassing the delaminated ribbons, the initial performance is recovered, and overall losses of the lamination-free samples become negligible.

14 SOLAR ENERGY↗

Design and performance oof space station photovoltaic radiators

The design and performance of the Space Station Freedom Photovoltaic (PV) Power Module Thermal Control System radiators is presented. The PV Radiator is of a single phase pumped loop design using liquid ammonia as the coolant. Key design features are described, including the base structure, deployment mechanism, radiator panels, and two independent coolant loops. The basis for a specific mass of 7.8 kg/sqm is discussed, and methods of lowering this number for future systems are briefly described. Key performance paramters are also addressed. A summary of test results and analysis is presented to illustrate the survivability of the radiator in the micrometeoroid and orbital debris environment. A design criterion of 95% probability of no penetration of both fluid loops over a 10 year period is shown to be met. Methods of increasing the radiator survivability even further are presented. Thermal performance is also discussed, including a comparison of modeling predictions with existing test results. Degradation in thermal performance due to exposure to atomic oxygen and ultraviolet radiation in the low Earth orbit environment is presented. The structural criteria to which the radiator is designed are also briefly addressed. Finally, potential design improvements are discussed.

White, K. Alan↗

PV Lifetime Project - 2025 NLR Annual Report

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light and elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions. Overall annual degradation rates are as follows: our first modules to be deployed (Jinko, Trina, QCells) have annual median degradation rate between -0.4%/yr and -0.5%/yr mainly concentrated in the first year. Mission Solar, LG and Panasonic modules are all displaying modest degradation, better than -0.3% / year. Indeed, Mission Solar fielded modules degraded less than their control modules which remain indoors and un-exposed. This is also true for the LONGi monofacial modules, which had some field degradation, but not as much as the degradation of the indoor control modules. The LONGi bifacial modules on the other hand have degraded more in the field than their monofacial counterparts, although still a modest amount (-0.4 %/yr). Of the four newest module types in the study, only one has had better than average degradation. REC360NP2 (N-type TOPCon) had a slight performance increase over the first year and a half of field deployment. For the other three new module types (plus one older module type), degradation was more rapid. In our study of 16 module types, four have demonstrated degradation faster than -1%/yr: two N-type Heterojunction, one PERC bifacial and one PERC shingled module. The two heterojunction modules in our study are degrading the most rapidly. Sunpreme n-HIT bifacial modules are showing a loss rate around -1.5%/yr, for over -10% total to date. This is largely attributed to loss in front-side Isc. This is distinct from the REC 405AA-Pure modules which have degraded -6.8% in only a year and a half, for an annualized decline of -3.9 %/yr. For this module type, the decline is roughly half in Voc, with the remaining split between FF and Isc. Of the remaining two module types, Prism Solar PERC bifacial has declined -5% total since 2019, although this loss appears to have stabilized in the most recent measurement. The Solaria PowerX-400R Shingled module type has also lost around -3.2% in the first 1.5 years of field deployment. It remains to be seen if these losses will continue with time.

14 SOLAR ENERGY↗

PV Lifetime Project (2024 NREL Annual Report)

DOE’s PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions.

14 SOLAR ENERGY↗

Uniform Mechanical Loading Can Test for Nonuniform Loading Durability

In this work, we present a method to evaluate the equivalency between any module mechanical loading conditions. The method is developed to address the specific failure mode of glass fracture and is based on Weibull analysis and weakest link theory. It considers the varying stress profile across the module to calculate the probability of glass fracture, which is used as the metric of equivalency. An idealized nonuniform loading scheme is employed to demonstrate the method and introduce the concept of the equivalent uniform load factor: a factor applied to the maximum pressure of the nonuniform load to obtain the equivalent uniform load value. It is demonstrated that this factor is less than unity for all nonuniform load cases considered, including snow and various characters of wind loading. These significant results suggest that uniform loading may be reliably, and practically, employed to evaluate photovoltaic module glass for nonuniform loading durability.

14 SOLAR ENERGY↗

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY↗

Analyzing the impact of design factors on solar module thermomechanical durability using interpretable machine learning techniques

Solar modules in utility-scale systems are expected to maintain decades of lifetime to rival conventional energy sources. However, cyclic thermomechanical loading often degrades their long-term performance, highlighting the importance of effective design to mitigate thermal expansion mismatches between module materials. Given the complex composition of solar modules, isolating the impact of individual components on overall durability remains a challenging task. In this work, we analyze a comprehensive data set that comprises bill-of-materials (BOM) and thermal cycling power loss from 251 distinct module designs to identify the predominant design factors and their impacts on the thermomechanical durability of modules. The methodology of our analysis combines machine learning modeling (random forest) and Shapley additive explanation (SHAP) to correlate design factors with power loss and interpret the model’s decision-making. The interpretation reveals that silicon type (monocrystalline or polycrystalline), encapsulant thickness, busbar numbers, and wafer thickness predominantly influence the degradation. With lower power loss of around 0.6% on average in the SHAP analysis, monocrystalline cells present better durability than polycrystalline cells. This finding is further substantiated by statistical testing on our raw data set. The SHAP analysis also demonstrates that while thicker encapsulants lead to reduced power loss, further increasing their thickness over around 0.6 to 0.7 mm does not yield additional benefits, particularly for the front side one. In addition, other important BOM features such as the number of busbars are analyzed. This study provides a blueprint for utilizing explainable machine learning techniques in a complex material system and can potentially guide future research on optimizing the design of solar modules.

14 SOLAR ENERGY↗

Live State of Health Monitoring of Inverter Subsystems

This presentation talks about different failure modes and corresponding detection schemes of PV panels, PV inverters, electric machines such as motors and power converter. Several novel techniques have been presented that are capable of measuring degradation as well as detecting faults in various location in a PV based power system.

ENGINEERING,SOLAR ENERGY↗