Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Investigation of Failure Modes, Mechanisms and Driving Forces for Electrically Conductive Adhesives as Interconnects in PV Modules

In this work we describe our current progress into investigating the reliability of ECA interconnects for PV modules. Preliminary thermal cycling experiments demonstrated that both cohesive and adhesive failure of the ECA joint are relevant failure modes that result in an increase of the joints electrical resistance. A thorough viscoelastic characterization of the candidate ECA was conducted to enable accurate numerical modeling of the joint’s response to thermal cycling. Combined with critical and subcritical fracture measurements, the numerical model elucidates that an additional fatigue mechanism exists which can result in fracture well below subcritical debonding threshold values. It is also demonstrated that fracture of the ECA is more sensitive to humidity than temperature and subcritical debonding mechanisms do exist which are again more sensitive to humidity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Composite Power System Reliability with Renewables and Customer Flexibility

Composite Power System Reliability is defined as the computational procedure that quantifies the probability that the power system will perform the function of delivering electric power to customers adequately, on a continuous basis and with an acceptable quality. This definition leaves many details undefined and exemplifies the ambiguity in reliability analysis. The increasing deployment of wind and PV creates additional uncertainties that make reliability analysis a rather complex issue. Because of increased uncertainty the need for composite reliability analysis and utilization of results in power system planning is critical. New approaches are emerging for dealing with these problems from the operational point of view, including demand response programs, tapping on customer and distributed resource flexibility and new control approaches. The key question to be addressed is: how the new operational paradigms affect composite power system reliability. Here, this paper presents the ongoing work of the IEEE Composite System Reliability Task Force of the IEEE PES Reliability, Risk, Probability Application (RRPA) Subcommittee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

transparent backsheet↗

The Sustainable Decarbonization Challenge

Many countries have decarbonization plans that include transitioning to clean energy. Because of this, PV deployment is projected to at least double or triple in the next ten years. As we ramp up manufacturing and deployment, we aim to sustainably establish secure and just supply chains while reducing environmental impacts. This talk presents our analysis of the virgin material demands, addresses waste concerns regarding quantity and toxicity, and establishes sustainability actions that the PV community can take to ensure sustainability. The takeaway actions are prioritizing reliable, high-quality, and long-lived PV modules and enabling the fast deployment needed for decarbonization via more research and effective communication.

circular economy↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

Hierarchical, Grid-Aware, and Economically Optimal Coordination of Distributed Energy Resources in Realistic Distribution Systems

Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

distribution network↗

Thermomechanical fatigue resistance of low temperature solder for multiwire interconnects in photovoltaic modules

Novel interconnect technologies leveraging low melting temperature solders, such as multiwire interconnects, are being deployed in photovoltaic (PV) modules for improved reliability through interconnect redundancy and lower thermal loads during interconnection and lamination. However, the equivalency of standardized accelerated testing to field conditions has not yet been established for these emerging technologies. In this study, the thermomechanical fatigue resistance of low temperature solder alloys is investigated and compared to that of conventional SnPb to assess the acceleration behavior of these alloys. While InSn is shown to have sufficient thermomechanical fatigue resistance on the order of that of SnPb, these results indicate Sn–Bi alloys may have poor thermomechanical fatigue resistance at field conditions. The results also show that Sn–Bi alloys have thermal cycling acceleration factors of less than one. This indicates that the standardized accelerated thermal cycling test, such as that in IEC 61215, will produce misleading results for Sn–Bi alloys and that unique testing is required for this PV module architecture. Though accelerated thermal cycling may be a meaningful qualification test for SnPb solder joints, these results suggest that mechanical loading may be a more appropriate test for Sn–Bi multiwire interconnects. This is due to the distinct processing and geometry of multiwire interconnects which may allow for mechanical, rather than strictly metallurgical interconnections.

14 SOLAR ENERGY↗

Reducing module soiling with scalable and robust photocatalytic coatings

The air-glass interface at the front of a photovoltaic (PV) module reflects approximately 4% of incident light, decreasing the potential power output of the module by the same amount. Today’s modules reduce this loss by adding a low-refractive-index (1.25-1.30) SiO2 coating to the sunward side of the module glass; this antireflection coating recovers approximately 3% of the 4% light that would otherwise be lost. While such antireflection coatings work very well on clean, new modules, they do not inhibit soiling—the accumulation of soilants such as dust, pollen, soot, or other foreign material—on the module glass, and soilants reflect and scatter incident light. An improved coating would serve provide not only an antireflection effect, but also an anti-soiling effect. The goal of this project was to develop such a coating and provide a path for it to be manufactured in the U.S. The project successfully designed and fabricated coatings that provided >3% transmittance gain compared to bare glass (matching the performance of commercial antireflection coatings) and displayed anti-soiling behavior in standard laboratory soiling effects. This was achieved by using a Swift Coat proprietary coating deposition technique, aerosol impact-driven assembly (AIDA), to control the porosity and thus refractive index of coatings of photocatalytic materials—such as TiO2—that would otherwise increase (instead of decrease) reflection. These combined antireflection/anti-soiling coatings passed PV industry standard module reliability tests as well as coating-specific abrasion tests, showing that they have the durability needed for decades in the field. Swift Coat scaled the AIDA hardware and deposition process to make mini-modules that were monitored for nearly two years during field tests administered by a third party, as well as demonstrated scaling to the widths of full-sized modules. The fielded mini-modules outperformed reference modules (with commercial antireflection coatings) in two locations, providing a 1% absolute average performance boost and larger increases during periods of heavier soiling. Swift Coat’s cost analysis indicated a coating manufacturing cost below the sales price of today’s antireflection coatings. More than five module manufacturers sampled and assessed the coatings, and three provided letters of support. The coating developed in this project increases the energy output of PV modules, thereby decreasing the cost per kilowatt-hour of solar energy generated. Cheaper solar electricity benefits the public by accelerating the transition to a stable, affordable, carbon-free energy economy. In addition, for select applications in which PV modules are highly visible—such as on residential rooftops—the coating provides an aesthetic benefit because it stays cleaner than today’s modules. Finally, Swift Coat and its prospective customers are U.S. companies, and successful commercialization of this technology will provide U.S. jobs and a secure solar supply chain.

14 SOLAR ENERGY↗

Accelerated reliability tests of n + and p + poly-Si passivated contacts

We report on the stability of encapsulated, low-pressure chemical vapor-deposited phosphorus (n + poly-Si) doped and boron (p + poly-Si) doped poly-Si/SiO x passivated contacts by exposing the samples to three different accelerated tests: damp heat test, thermal cycling and ultraviolet exposure, adhering closely to the IEC 61215 standard. Outdoor testing was also performed by exposing the samples in the outdoor testing field at the National Renewable Energy Laboratory, and preliminary data accumulated for 1000 h from February to April of 2021 is reported. We studied non-metallized, thermally-metallized, and screen-printed n + and p + poly-Si by monitoring the effective minority carrier lifetime at the implied maximum power point using a Sinton lifetime tester, and recorded photoluminescence images before and after the exposure. Furthermore, the samples were found to be stable under all test conditions, which is encouraging for incorporation of these contacts in next-generation industrial silicon solar cells.

14 SOLAR ENERGY↗

Employing Weibull Analysis and Weakest Link Theory to Resolve Crystalline Silicon PV Cell Strength Between Bare Cells and Reduced- and Full-Sized Modules

Weibull analysis and weakest link theory are employed to resolve the probability of crystalline silicon PV cell fracture when measured as bare cells and when stressed in reduced- and full-sized modules. Experimental results indicated that the characteristic cell strength is reduced by ~20% once packaged into the laminate of a one-cell module and loaded in four-point flexure (4PF). This experimental observation was shown consistent with a weakest link theory prediction that the strength limiting flaws reside on the surface of the cell's edge. Here, the analysis is ultimately extended to present the equivalent loading of four-cell modules by uniform pressure and 4PF and a uniformly loaded full-sized module and demonstrates that smaller, representative, modules must be loaded to a much higher level than their parent full-sized modules to achieve an equivalent probability for cell fracture.

14 SOLAR ENERGY↗

Turn Your Half-Cut Cells for a Stronger Module

Here, we employ an existing model of crystalline silicon photovoltaic module cell fracture to explore the effect of cell size and orientation on their probability of fracture under module uniform loading. In addition, we also apply continuum damage mechanics to modify this model to consider the effect of cell fracture on the probability of subsequent cell fracture. We elucidate that cell fracture increases the probability of subsequent cell fracture and that rectangular modules containing half-cells aligned with the module's long orientation are much more robust against cell fracture than full-cell and half-cell short orientation modules.

14 SOLAR ENERGY↗

Solar Cell Metallization Wear is Sensitive to Loading Frequency

Here, we performed cyclic loading of photovoltaic laminates with precracked silicon cells to explore if and how loading frequency and contact pressure influence the ensuing gridline wear-out process. A measurement of parallel resistance across cracked gridlines on a laminated cell coupon was used as the metric for gridline electrical contact degradation. A statistical analysis of variance (ANOVA) analysis of the experimental results discerned that loading frequency is a more significant factor than contact pressure for gridline degradation.

14 SOLAR ENERGY↗

Extended Accelerated Stress Testing of Lamination-Free Edge-Sealed Photovoltaic Minimodules

Lamination-free minimodules are constructed with silicon solar cells between glass sheets and an edge seal of polyisobutylene and silicone. These samples are stressed using a repeated sequential testing sequence including ultraviolet-containing simulated solar spectrum light exposure at elevated temperature, damp heat, humidity freeze, and thermal cycling adapted from the International Electrotechnical Commission (IEC) TS 63209-2:2022. The minimodule performance throughout the stressing is characterized by flash testing and electroluminescence imaging. Results are compared to conventional laminated minimodules using the same type of solar cells. The lamination-free minimodules experience up to 8% power loss compared to roughly 3% for the laminated versions. However, those losses, dominated by current and fill factor, are caused by glass soiling and busbar ribbon separation on the cells. When glass is replaced and the stressed cells are contacted with probes bypassing the delaminated ribbons, the initial performance is recovered, and overall losses of the lamination-free samples become negligible.

14 SOLAR ENERGY↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control

This paper validates the efficacy of an artificial intelligence (AI)-based photovoltaic (PV) plant control and optimization approach in enabling PV plants as accountable grid reliability service providers. The validation is performed in a realistic laboratory controller-hardware-in-the-loop environment, leveraging accurate PV plant modeling and standard industrial communication protocols. Through simulations that account for diverse weather conditions and active control scenarios, the results highlight the superior performance of the AI-based solution in comparison to a state-of-the-art reference-control grouping-based approach. Such a finding contributes to mitigating the risk of overcurtailment and uninstructed deviations of active PV plant controls, and offers practical guidance for its field deployment. Furthermore, it establishes a standardized testing framework for comparing various PV active control strategies.

hardware-in-the-loop↗