SU-D-16A-01: A Novel Method to Estimate Normal Tissue Dose for Radiotherapy Patients to Support Epidemiologic Studies of Second Cancer Risk

Purpose: Patient cohort of second cancer study often involves radiotherapy patients with no radiological images available: We developed methods to construct a realistic surrogate anatomy by using computational human phantoms. We tested this phantom images both in a commercial treatment planning system (Eclipse) and a custom Monte Carlo (MC) transport code. Methods: We used a reference adult male phantom defined by International Commission on Radiological Protection (ICRP). The hybrid phantom which was originally developed in Non-Uniform Rational B-Spline (NURBS) and polygon mesh format was converted into more common medical imaging format. Electron density was calculated from the material composition of the organs and tissues and then converted into DICOM format. The DICOM images were imported into the Eclipse system for treatment planning, and then the resulting DICOM-RT files were imported into the MC code for MC-based dose calculation. Normal tissue doses were calculation in Eclipse and MC code for an illustrative prostate treatment case and compared to each other. Results: DICOM images were generated from the adult male reference phantom. Densities and volumes of selected organs between the original phantom and ones represented within Eclipse showed good agreements, less than 0.6%. Mean dose from Eclipse and MC code match less than 7%, whereas maximum and minimum doses were different up to 45%. Conclusion: The methods established in this study will be useful for the reconstruction of organ dose to support epidemiological studies of second cancer in cancer survivors treated by radiotherapy. We also work on implementing body size-dependent computational phantoms to better represent patient's anatomy when the height and weight of patients are available.

60 APPLIED LIFE SCIENCES↗

The Role of Interventional Radiology in the Management of Deep Venous Thrombosis: Advanced Therapy

Deep vein thrombosis (DVT) is often managed with a health care pathway that funnels patients to anticoagulation therapy alone. This 'usual treatment' is designed to stop propagation and embolisation of venous thrombus but not remove it. Surgical thrombectomy was once the only option in severe cases in which limbs were threatened, but thrombus removal is no longer restricted to emergency cases. Interventional radiologists are now using advanced endovascular techniques to achieve thrombus removal in a minimally invasive manner in a very short treatment time, thereby quickly restoring patency, relieving acute symptoms, and potentially limiting the subsequent development of postthrombotic syndrome when followed with anticoagulation and compression regimens. This article provides an overview of the interventions available for treating DVT. One of the newer 'single-session' techniques is isolated pharmacomechanical thrombolysis, which is described here in detail with supporting cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A real-time respiration position based passive breath gating equipment for gated radiotherapy: A preclinical evaluation

Purpose: To develop a passive gating system incorporating with the real-time position management (RPM) system for the gated radiotherapy. Methods: Passive breath gating (PBG) equipment, which consists of a breath-hold valve, a controller mechanism, a mouthpiece kit, and a supporting frame, was designed. A commercial real-time positioning management system was implemented to synchronize the target motion and radiation delivery on a linear accelerator with the patient's breathing cycle. The respiratory related target motion was investigated by using the RPM system for correlating the external markers with the internal target motion while using PBG for passively blocking patient's breathing. Six patients were enrolled in the preclinical feasibility and efficiency study of the PBG system. Results: PBG equipment was designed and fabricated. The PBG can be manually triggered or released to block or unblock patient's breathing. A clinical workflow was outlined to integrate the PBG with the RPM system. After implementing the RPM based PBG system, the breath-hold period can be prolonged to 15-25 s and the treatment delivery efficiency for each field can be improved by 200%-400%. The results from the six patients showed that the diaphragm motion caused by respiration was reduced to less than 3 mm and the position of the diaphragm was reproducible for difference gating periods. Conclusions: A RPM based PBG system was developed and implemented. With the new gating system, the patient's breath-hold time can be extended and a significant improvement in the treatment delivery efficiency can also be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Low Dose Radiation Adaptive Response to Control Aging-Related Disease

Oxidative damage has been implicated in the pathogenesis of most aging-related diseases including neurodegenerative diseases. Antioxidant supplementation has been found to be ineffective in reducing such diseases, but increased endogenous production of antioxidants from the adaptive response due to physical and cognitive exercises (which increase oxidative metabolism and oxidative stress) has been effective in reducing some of the diseases. Low dose radiation (LDR), which increases oxidative stress and results in adaptive response of increased antioxidants, may provide an alternative method of controlling the aging-related diseases. We have studied the effect of LDR on the induction of adaptive response in rat brains and the effectiveness of the LDR in reducing the oxidative damage caused by subsequent high dose radiation. We have also investigated the effect of LDR on apomorphine-induced rotations in the 6-hydroxydopamine (6-OHDA) unilaterally-lesioned rat model of Parkinson's disease (PD). LDR was observed to initiate an adaptive response in the brain, and reduce the oxidative damage from subsequent high dose radiation exposure, confirming the effectiveness of LDR adaptive response in reducing the oxidative damage from the free radicals due to high dose radiation. LDR resulted in a slight improvement in Tyrosine hydroxylase expression on the lesioned side of substantia nigra (indicative of its protective effect on the dopaminergic neurons), and reduced the behavioral symptoms in the 6-OHDA rat model of PD. Translation of this concept to humans, if found to be applicable, may be a possible approach for controlling the progression of PD and other neurodegenerative diseases. Since any translation of the concept to humans would be hindered by the currently prevalent carcinogenic concerns regarding LDR based on the linear no-threshold (LNT) model, we have also studied the justifications for the use of the LNT model. One of the shortcomings of the LNT model is that it ignores the effects of any adaptive response of the body to the LDR. The importance of considering adaptive response becomes obvious when one considers the sharp contrast between (i) the failure of well-designed anti-angiogenesis therapies which resulted in aggressive tumors because of ignoring adaptive response and (ii) the occasional cure of untreated metastatic lesions likely due to the incidental adaptive response from the LDR exposure to parts of the body during radiation therapy of a primary tumor, known as the abscopal effect. Another shortcoming of the LNT model is that it pays exclusive attention to increase in mutations, which is not a decisive factor in the occurrence of clinical cancers, as the cause of excess cancers. On the other hand, LNT model ignores the immune system response, which plays a very important role in preventing occult cancers from becoming clinical cancers, as demonstrated by the large increase in cancers in organ transplant patients whose immune system is suppressed. There is also recent epidemiological evidence against the LNT model. A re-analysis of the latest update to the atomic bomb survivor data has shown that the data no longer support the LNT model but are consistent with the radiation hormesis hypothesis. A re-analysis of cancer incidence data of Taiwanese apartment dwellers that were exposed to LDR from contaminated building materials has also shown a reduction in cancers from the LDR. The present LDR carcinogenic concerns would preclude any human study of cancer prevention using LDR, since the study would require subjecting a large asymptomatic population to LDR. However, pilot studies of radiation hormesis in cancer patients may be more acceptable since these would require irradiation of limited numbers of patients in order to assess the effectiveness of the LDR treatments. Some of the LDR applications that may be considered for cancer patients are: LDR treatment of early stage cancers without the adverse side effects of current treatments such as radiation therapy or chemotherapy, adjuvant LDR treatment of cancer patients undergoing radiation therapy for better tumor control and reduced metastasis, and the use of LDR treatment following radiation therapy to reduce the risk of second cancers from the radiation therapy. Studies of LDR for the control of early-stage neurodegenerative diseases may also be more acceptable since currently there are no effective treatments available for controlling these diseases, and since such studies would require LDR exposure to limited parts of the brain, and the carcinogenic risk from such treatments would be very small due to the low radiation tissue-weighting factor for the brain. Success in these studies can lead to the study of LDR for preventing and controlling other aging-related diseases.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-F-J-68: Deformable Dose Accumulation for Voxel-Based Dose Tracking of PTV Cold Spots for Adaptive Radiotherapy of the Head and Neck

Purpose: To utilize deformable dose accumulation (DDA) to determine how cold spots within the PTV change over the course of fractionated head and neck (H&N) radiotherapy. Methods: Voxel-based dose was tracked using a DDA platform. The DDA process consisted of B-spline-based deformable image registration (DIR) and dose accumulation between planning CT’s and daily cone-beam CT’s for 10 H&N cancer patients. Cold spots within the PTV (regions receiving less than the prescription, 70 Gy) were contoured on the cumulative dose distribution. These cold spots were mapped to each fraction, starting from the first fraction to determine how they changed. Spatial correlation between cold spot regions over each fraction, relative to the last fraction, was computed using the Jaccard index Jk (Mk,N), where N is the cold spot within the PTV at the end of the treatment, and Mk the same region for fraction k. Results: Figure 1 shows good spatial correlation between cold spots, and highlights expansion of the cold spot region over the course of treatment, as a result of setup uncertainties, and anatomical changes. Figure 2 shows a plot of Jk versus fraction number k averaged over 10 patients. This confirms the good spatial correlation between cold spots over the course of treatment. On average, Jk reaches ∼90% at fraction 22, suggesting that possible intervention (e.g. reoptimization) may mitigate the cold spot region. The cold spot, D99, averaged over 10 patients corresponded to a dose of ∼65 Gy, relative to the prescription dose of 70 Gy. Conclusion: DDA-based tracking provides spatial dose information, which can be used to monitor dose in different regions of the treatment plan, thereby enabling appropriate mid-treatment interventions. This work is supported in part by Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Tumor Radiation Therapy Creates Therapeutic Vaccine Responses to the Colorectal Cancer Antigen GUCY2C

Purpose: Radiation therapy (RT) is thought to produce clinical responses in cancer patients, not only through direct toxicity to cancer cells and supporting tumor stroma cells, but also through activation of immunologic effectors. More recently, RT has potentiated the local and systemic effects of cancer immunotherapy (IT). However, combination regimens that maximize immunologic and clinical efficacy remain undefined. Methods and Materials: We evaluated the impact of local RT on adenoviral-mediated vaccination against the colorectal cancer antigen GUCY2C (Ad5-GUCY2C) in a murine subcutaneous tumor model using mouse CT26 colon cancer cells (CT26-GUCY2C). Immune responses were assessed by ELISpot, and clinical responses were assessed by tumor size and incidence. Results: The specific sequence of tumor-directed RT preceding Ad5-GUCY2C IT transformed inactive therapeutic Ad5-GUCY2C vaccination into a curative vaccine. GUCY2C-specific T cell responses were amplified (P<.05), tumor eradication was maximized (P<.01), and tumor volumes were minimized (P<.001) in mice whose tumors were irradiated before, compared with after, Ad5-GUCY2C vaccination. The immunologic and antitumor efficacy of Ad5-GUCY2C was amplified comparably by unfractionated (8 Gy × 1), or biologically equivalent doses of fractionated (3.5 Gy × 3), RT. The antitumor effects of sequential RT and IT (RT-IT) depended on expression of GUCY2C by tumor cells and the adenoviral vaccine vector, and tumor volumes were inversely related to the magnitude of GUCY2C-specific T cell responses. Moreover, mice cured of CT26-GUCY2C tumors by RT-IT showed long-lasting antigen-dependent protection, resisting tumors formed by GUCY2C-expressing 4T1 breast cancer cells inoculated 50 days after CT26 cells. Conclusions: Optimal sequencing of RT and IT amplifies antigen-specific local and systemic immune responses, revealing novel acute and long-term therapeutic antitumor protection. These observations underscore the importance of modality sequence optimization before the initiation of clinical trials of RT and IT to maximize immune and antitumor responses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-BRA-08: Simulated Tumor Tracking in An MRI Linac for Lung Tumor Lesions Using the Monaco Treatment Planning System

Purpose: To simulate tumor tracking in an Elekta MRI-linac (MRL) and to compare this tracking method with our current ITV approach in terms of OAR sparing for lung cancer patients. Methods: Five SABR-NSCLC patients with central lung tumors were selected for reasons of potential enhancement of tumor-tissue delineation using MRI. The Monaco TPS was used to compare the current clinical ITV approach to a simulated, novel tracking method which used a 7MV MRL beam in the presence of an orthogonal 1.5 T magnetic field (4D-MRL method). In the simulated tracking scenario, achieved using the virtual couch shift (VCS), the PTV was defined using an isotropic 5mm margin applied to the GTV of each phase, as acquired from an 8-phase amplitude-binned 4DCT. These VCS plans were optimized and weighted on each phase. The dose weighting was performed using the patient-specific breathing traces. The doses were accumulated on the inhale phase. The two methods were compared by assessing the OAR DVHs. Results: The 4D-MRL method resulted in a reduced target volume (by an average of 29% over all patients). The benefits of using an MRL tracking system depended on the tumor motion amplitude and the relative OAR motion (ROM) to the target. The reduction in mean doses to parallel organs was up to 3 Gy for the heart and 2.1 Gy for the lung. The reductions in maximum doses to serial organs were up to 9.4 Gy, 5.6 Gy, and 8.7 Gy for the esophagus, spinal cord, and the trachea, respectively. Serial organs benefited from MRL tracking when the ROM was ≥ 0.3 cm despite small tumor motion amplitude in some cases. Conclusions: This work demonstrated the potential benefit for an MRL tracking system to spare OARs in SABR-NSCLC patients with central tumors. The benefits are embodied in the target volume reduction. This project was made possible with the financial support of Elekta.

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-03: A Quasi-Cine CBCT Reconstruction Technique for Real-Time On- Board Target Tracking of Lung Cancer Treatment

Purpose: To develop a quasi-cine CBCT reconstruction technique that uses extremely-small angle (∼3°) projections to generate real-time high-quality lung CBCT images. Method: 4D-CBCT is obtained at the beginning and used as prior images. This study uses extremely-small angle (∼3°) on-board projections acquired at a single respiratory phase to reconstruct the CBCT image at this phase. An adaptive constrained free-form deformation (ACFD) method is developed to deform the prior 4D-CBCT volume at the same phase to reconstruct the new CBCT. Quasi-cine CBCT images are obtained by continuously reconstructing CBCT images at subsequent phases every 3° angle (∼0.5s). Note that the prior 4D-CBCT images are dynamically updated using the latest CBCT images. The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of ACFD. A lung patient was simulated with a tumor baseline shift of 2mm along superior-inferior (SI) direction after every respiratory cycle for 5 cycles. Limited-angle projections were simulated for each cycle. The 4D-CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate their geometric differences.The ACFD was also compared to a principal-component-analysis based motion-modeling (MM) method. Results: Using orthogonal-view 3° projections, the VPD/COMS values for tumor baseline shifts of 2mm, 4mm, 6mm, 8mm, 10mm were 11.0%/0.3mm, 25.3%/2.7mm, 22.4%/2.9mm, 49.5%/5.4mm, 77.2%/8.1mm for the MM method, and 2.9%/0.7mm, 3.9%/0.8mm, 6.2%/1mm, 7.9%/1.2mm, 10.1%/1.1mm for the ACFD method. Using orthogonal-view 0° projections (1 projection only), the ACFD method yielded VPD/COMS results of 5.0%/0.9mm, 10.5%/1.2mm, 15.1%/1.4mm, 20.9%/1.6mm and 24.8%/1.6mm. Using single-view instead of orthogonal-view projections yielded less accurate results for ACFD. Conclusion: The ACFD method accurately reconstructs snapshot CBCT images using orthogonal-view 3° projections. It has a great potential to provide real-time quasi-cine CBCT images for verification in lung radiation therapy. The research is supported by grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-12: Assessment of 4D-MRI for Robust Motion and Volume Characterization

Purpose: Precise radiation therapy for abdominal lesions is complicated by respiratory motion and poor soft tissue contrast from 4DCT whereas 4DMRI provides superior tissue discrimination. We evaluated a novel 4D-MRI algorithm for MR-SIM motion management. Methods: Respiratory-triggered, T2-weighted single-shot Turbo Spin Echo 4D-MRI was evaluated for open high-field 1.0T MR-SIM. A programmable platform pulled objects on a trolley ∼2 cm superior-inferior (S-I) for “regular” (sinusoidal, (1-cos{sup 2}), 3-5 second periods) and “irregular” breathing patterns (exaggerated (1-cos{sup 2}) and patient curves), while a respiratory waveform was generated via a pressure sensor device. Coronal 4D-MRIs (2–12;10 phases, TE/TR/α = 35−61/6100 ms/90°, voxel=1×1×4 mm{sup 3}) were acquired for 54 unique phantom cases. Abdominal 4D−MRIs were evaluated for 5 healthy volunteers and 1 liver cancer patient (6–10 phases, TE/TR/α = 30−96/4500−6100 ms/90°, voxel=1×1×5–10 mm{sup 3}) on an IRB-approved protocol. Duty cycle, scan time, and excursion were evaluated between phase acquisitions and compared to coronal cine-MRI (∼1 frame/sec). Maximum intensity projections (MIPs) were analyzed. Results: In phantom, average duty cycle was 42.6 ± 11.4% (range: 23.6–69.1%). Regular, periodic breathing (sinusoidal, (1-cos{sup 2})) yielded higher duty cycles than irregular (48.5% and 35.9%, respectively, p<0.001) and fast periods had higher duty cycles than slow (50.4% for 3s and 39.4% for 5s, p<0.001). ∼4-fold acquisition time increase was measured for 10-phase versus 2-phase. MIP renderings revealed that SI object extent was underestimated a maximum of 4% (3mm) and 8% (6mm) for cine and 2-phase 4D-MRI, respectively, with respect to 10-phases. However, this was waveform dependent. A highly irregular breathing volunteer yielded lowest duty cycle (23%) and longest 10-phase scan time (∼14 minutes), although 6-phase acquisition for a liver cancer patient was reasonable (50% and 7.4 minutes, respectively). Conclusion: 4D-MRI offers potential for excursion characterization, although results suggest the use of adequate phases is important. Further application and clinical validation are warranted. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an Internal Mentored Grant from Henry Ford Health System.

60 APPLIED LIFE SCIENCES↗

SU-E-J-183: Quantification of Motion During Hypo-Fractionated Prostate Cancer Radiation Therapy

Purpose: To quantify patient motion during hypo-fractionated prostate cancer treatment as tracked by Calypso™ 4D localization system. Methods: 50 prostate cancer patients with implanted Calypso beacons underwent hypofractionated IMRT treatment. Typical fraction size was 5 with doses of 5–8 Gy/fraction. 213 traces from the 50 patients were analyzed to quantify the probability of motion vs time starting from beam-on. Couch corrections applied by therapists were undone to obtain the natural course of patient motion. The Calypso data was used to identify vector displacements greater than 2 mm from the starting position. The direction of this vector was classified into one of the 26 directions (combinations of L/R, A/P, S/I). The probability of motion >2mm was estimated by computing the fraction of traces that exceed the 2mm threshold at each time point. The violating motion points were also binned by direction in order to identify specific directions that were more prone to movement. Results: The overall probability of motion greater than 2 mm at 5 and 10 minutes from beam-on were 27 % and 50% respectively. The primary directions in which motion occurred were Posterior-Inferior (PI) and Inferior (I) with a probability of 8.5% and 4% at 5 minutes and 10% for both at 10 minutes. Motion was classified into the following bins: 0–2, 2–3, 3–4, 4–5, 5–6, 6–7, 7–8 and greater than 8 mm. It is observed that motion < 2mm decreases from the first 5 minutes to the next while the higher magnitude components increase with time. Conclusion: The probability of prostate motion increases with time. The trend seen in the PI and I directions can be attributed to physiological factors like bladder filling. This probability can be factored in for scheduling intrafraction imaging and used to compare dosimetric impact of VMAT vs. IMRT plans. This work is supported in part by Varian Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-108: Template Matching Based On Multiple Templates Can Improve the Tumor Tracking Performance When There Is Large Tumor Deformation

Purpose: Recently, template matching has been shown to be able to track tumor motion on cine-MRI images. However, artifacts such as deformation, rotation, and/or out-of-plane movement could seriously degrade the performance of this technique. In this work, we demonstrate the utility of multiple templates derived from different phases of tumor motion in reducing the negative effects of artifacts and improving the accuracy of template matching methods. Methods: Data from 2 patients with large tumors and significant tumor deformation were analyzed from a group of 12 patients from an earlier study. Cine-MRI (200 frames) imaging was performed while the patients were instructed to breathe normally. Ground truth tumor position was established on each frame manually by a radiation oncologist. Tumor positions were also automatically determined using template matching with either single or multiple (5) templates. The tracking errors, defined as the absolute differences in tumor positions determined by the manual and automated methods, when using either single or multiple templates were compared in both the AP and SI directions, respectively. Results: Using multiple templates reduced the tracking error of template matching. In the SI direction where the tumor movement and deformation were significant, the mean tracking error decreased from 1.94 mm to 0.91 mm (Patient 1) and from 6.61 mm to 2.06 mm (Patient 2). In the AP direction where the tumor movement was small, the reduction of the mean tracking error was significant in Patient 1 (from 3.36 mm to 1.04 mm), but not in Patient 2 ( from 3.86 mm to 3.80 mm). Conclusion: This study shows the effectiveness of using multiple templates in improving the performance of template matching when artifacts like large tumor deformation or out-of-plane motion exists. Accurate tumor tracking capabilities can be integrated with MRI guided radiation therapy systems. This work was supported in part by grants from NIH/NCI CA 124766 and Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-10: A Statistical Voxel Based Normal Organ Dose Prediction Model for Coplanar and Non-Coplanar Prostate Radiotherapy

Purpose: Knowledge learned from previous plans can be used to guide future treatment planning. Existing knowledge-based treatment planning methods study the correlation between organ geometry and dose volume histogram (DVH), which is a lossy representation of the complete dose distribution. A statistical voxel dose learning (SVDL) model was developed that includes the complete dose volume information. Its accuracy of predicting volumetric-modulated arc therapy (VMAT) and non-coplanar 4π radiotherapy was quantified. SVDL provided more isotropic dose gradients and may improve knowledge-based planning. Methods: 12 prostate SBRT patients originally treated using two full-arc VMAT techniques were re-planned with 4π using 20 intensity-modulated non-coplanar fields to a prescription dose of 40 Gy. The bladder and rectum voxels were binned based on their distances to the PTV. The dose distribution in each bin was resampled by convolving to a Gaussian kernel, resulting in 1000 data points in each bin that predicted the statistical dose information of a voxel with unknown dose in a new patient without triaging information that may be collectively important to a particular patient. We used this method to predict the DVHs, mean and max doses in a leave-one-out cross validation (LOOCV) test and compared its performance against lossy estimators including mean, median, mode, Poisson and Rayleigh of the voxelized dose distributions. Results: SVDL predicted the bladder and rectum doses more accurately than other estimators, giving mean percentile errors ranging from 13.35–19.46%, 4.81–19.47%, 22.49–28.69%, 23.35–30.5%, 21.05–53.93% for predicting mean, max dose, V20, V35, and V40 respectively, to OARs in both planning techniques. The prediction errors were generally lower for 4π than VMAT. Conclusion: By employing all dose volume information in the SVDL model, the OAR doses were more accurately predicted. 4π plans are better suited for knowledge-based planning than the VMAT plans that are strongly biased in its dose gradient orientation. This project is supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.

60 APPLIED LIFE SCIENCES↗

SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11275105). Thanks for the support from Accuray Corp.

60 APPLIED LIFE SCIENCES↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-I-04: Automatic Skin-Dose Mapping for An Angiographic System with a Region-Of-Interest, High-Resolution Detector

Purpose: Our real-time skin dose tracking system (DTS) has been upgraded to monitor dose for the micro-angiographic fluoroscope (MAF), a high-resolution, small field-of-view x-ray detector. Methods: The MAF has been mounted on a changer on a clinical C-Arm gantry so it can be used interchangeably with the standard flat-panel detector (FPD) during neuro-interventional procedures when high resolution is needed in a region-of-interest. To monitor patient skin dose when using the MAF, our DTS has been modified to automatically account for the change in scatter for the very small MAF FOV and to provide separated dose distributions for each detector. The DTS is able to provide a color-coded mapping of the cumulative skin dose on a 3D graphic model of the patient. To determine the correct entrance skin exposure to be applied by the DTS, a correction factor was determined by measuring the exposure at the entrance surface of a skull phantom with an ionization chamber as a function of entrance beam size for various beam filters and kVps. Entrance exposure measurements included primary radiation, patient backscatter and table forward scatter. To allow separation of the dose from each detector, a parameter log is kept that allows a replay of the procedure exposure events and recalculation of the dose components.The graphic display can then be constructed showing the dose distribution from the MAF and FPD separately or together. Results: The DTS is able to provide separate displays of dose for the MAF and FPD with field-size specific scatter corrections. These measured corrections change from about 49% down to 10% when changing from the FPD to the MAF. Conclusion: The upgraded DTS allows identification of the patient skin dose delivered when using each detector in order to achieve improved dose management as well as to facilitate peak skin-dose reduction through dose spreading. Research supported in part by Toshiba Medical Systems Corporation and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-05: Design and Geometric Validation of An Externally and Internally Deformable, Programmable Lung Motion Phantom

Purpose: Most clinically-deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating, tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are rigid-exterior+rigid-interior or rigid-exterior+deformable-interior. Neither class adequately represents the human anatomy, which is deformable internally as well as externally. We describe the construction and experimental validation of a more realistic, externally- and internally-deformable, programmable lung phantom. Methods: The outer shell of a commercially-available lung phantom (RS- 1500, RSD Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A 3-axis platform was programmed with sinusoidal and six patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam ‘diaphragm’ that compressed/decompressed the phantom interior. Experimental characterization comprised of mapping the superior-inferior (SI) and anterior-posterior (AP) trajectories of external and internal radioopaque markers with kV x-ray fluoroscopy and correlating these with optical surface monitoring using the in-room VisionRT system. Results: The phantom correctly reproduced the programmed motion as well as realistic effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.4 mm RMS error for internal as well as external markers. The motion trajectories of internal and external markers as measured by fluoroscopy were found to be highly correlated (R=0.97). Furthermore, motion trajectories of arbitrary points on the deforming phantom surface, as recorded by the VisionRT system also showed a high correlation with respect to the fluoroscopically-measured trajectories of internal markers (R=0.92). Conclusion: We have developed a realistic externally- and internally-deformable lung phantom that will serve as a valuable tool for clinical QA and motion management research. This work was supported through funding from the NIH and VisionRT Ltd. Amit Sawant has research funding from Varian Medical Systems, VisionRT and Elekta.

60 APPLIED LIFE SCIENCES↗