Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance: Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comparisons between tokamak fueling of gas puffing and supersonic molecular beam injection in 2D simulations

Plasma fueling with high efficiency and deep injection is very important to enable fusion power performance requirements. It is a powerful and efficient way to study neutral transport dynamics and find methods of improving the fueling performance by doing large scale simulations. Two basic fueling methods, gas puffing (GP) and supersonic molecular beam injection (SMBI), are simulated and compared in realistic divertor geometry of the HL-2A tokamak with a newly developed module, named trans-neut, within the framework of BOUT++ boundary plasma turbulence code [Z. H. Wang et al., Nucl. Fusion 54, 043019 (2014)]. The physical model includes plasma density, heat and momentum transport equations along with neutral density, and momentum transport equations. Transport dynamics and profile evolutions of both plasma and neutrals are simulated and compared between GP and SMBI in both poloidal and radial directions, which are quite different from one and the other. It finds that the neutrals can penetrate about four centimeters inside the last closed (magnetic) flux surface during SMBI, while they are all deposited outside of the LCF during GP. It is the radial convection and larger inflowing flux which lead to the deeper penetration depth of SMBI and higher fueling efficiency compared to GP.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Commercialization of an IDAES-Based Power Plant Performance Monitoring and Optimization System

DOE and NETL have created an advanced, open-source computational platform through the Institute for the Design of Advanced Energy Systems (IDAES). The IDAES platform is a very extensive modeling environment that can be used for a broad range of power plant and process applications. MapEx Software is developing and commercializing a software application that makes it easier to set-up and run IDAES-based analyses. The MapEx-developed software application will replace the need for custom Python language coding with a user-friendly graphical user interface where the user can construct a flowsheet diagram of the IDAES model by inserting icons representing the plant equipment onto the screen. This application will make the implementation of modeling and optimization of existing fossil-fired power plants more straight-forward and less time-consuming. The effort focuses on performance monitoring and optimization of plant operations for the existing coal-fired power plant fleet but is built on a structure that allows expansion into the broad range of applications where IDAES methods may be applied.

20 FOSSIL-FUELED POWER PLANTS↗

The effects of regional insolation differences upon advanced solar thermal electric power plant performance and energy costs

This paper presents the performance and cost of four 10-MWe advanced solar thermal electric power plants sited in various regions of the continental United States. Each region has different insolation characteristics which result in varying collector field areas, plant performance, capital costs, and energy costs. The paraboloidal dish, central receiver, cylindrical parabolic trough, and compound parabolic concentrator (CPC) comprise the advanced concepts studied. This paper contains a discussion of the regional insolation data base, a description of the solar systems' performances and costs, and a presentation of a range for the forecast cost of conventional electricity by region and nationally over the next several decades.

Latta, A. F.↗

On the Path to SunShot. Advancing Concentrating Solar Power Technology, Performance, and Dispatchability

This report examines the remaining challenges to achieving the competitive concentrating solar power (CSP) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Although CSP costs continue to decline toward SunShot targets, CSP acceptance and deployment have been hindered by inexpensive photovoltaics (PV). However, a recent analysis found that thermal energy storage (TES) could increase CSP's value--based on combined operational and capacity benefits--by up to 6 cents/kWh compared to variable-generation PV, under a 40% renewable portfolio standard in California. Thus, the high grid value of CSP-TES must be considered when evaluating renewable energy options. An assessment of net system cost accounts for the difference between the costs of adding new generation and the avoided cost from displacing other resources providing the same level of energy and reliability. The net system costs of several CSP configurations are compared with the net system costs of conventional natural-gas-fired combustion-turbine (CT) and combined-cycle plants. At today's low natural gas prices and carbon emission costs, the economics suggest a peaking configuration for CSP. However, with high natural gas prices and emission costs, each of the CSP configurations compares favorably against the conventional alternatives, and systems with intermediate to high capacity factors become the preferred alternatives. Another analysis compares net system costs for three configurations of CSP versus PV with batteries and PV with CTs. Under current technology costs, the least-expensive option is a combination of PV and CTs. However, under future cost assumptions, the optimal configuration of CSP becomes the most cost-effective option.

14 SOLAR ENERGY↗

Adaptive prefetching on POWER7: Improving performance and power consumption

Hardware data prefetch engines are integral parts of many general purpose server-class microprocessors in the field today. Some prefetch engines allow users to change some of their parameters. But, the prefetcher is usually enabled in a default configuration during system bring-up, and dynamic reconfiguration of the prefetch engine is not an autonomic feature of current machines. Conceptually, however, it is easy to infer that commonly used prefetch algorithms—when applied in a fixed mode—will not help performance in many cases. In fact, they may actually degrade performance due to useless bus bandwidth consumption and cache pollution, which in turn, will also waste power. We present an adaptive prefetch scheme that dynamically modifies the prefetch settings in order to adapt to workloads

adaptive system↗

SNL-SWAN

Sandia National Laboratories has modified Simulating WAves Nearshore (SWAN), the Delft University of Technology code,, to include functionality to better model wave energy converters (WECs). The code modified by SNL has been named SNL-SWAN. SNL-SWAN includes a frequency dependent WEC Module that builds upon the traditional obstacle module in SWAN. In SNL-SWAN, a frequency dependent transmission coefficient is calculated to model power absorbed by WEC devices. The power transmission coefficients are calculated based on the WEC's power performance, which is defined by the user in the input text files. Two methods of defining WEC power performance have been implemented: a user-specified power matrix, and a user-specified relative capture width. These methods allow the user to define the WEC's frequency dependent energy absorption as a function of period and/or wave height. SWAN test cases were run to verify the compiled code's functionality, and verification of the frequency dependent WEC Module in SNL-SWAN has also been performed. SNL-SWAN code is will be released as open source code and will be made publicly available.

Chartrand, Chris↗

SNL-SWAN

Sandia National Laboratories has modified Simulating WAves Nearshore (SWAN), the Delft University of Technology code,, to include functionality to better model wave energy converters (WECs). The code modified by SNL has been named SNL-SWAN. SNL-SWAN includes a frequency dependent WEC Module that builds upon the traditional obstacle module in SWAN. In SNL-SWAN, a frequency dependent transmission coefficient is calculated to model power absorbed by WEC devices. The power transmission coefficients are calculated based on the WEC's power performance, which is defined by the user in the input text files. Two methods of defining WEC power performance have been implemented: a user-specified power matrix, and a user-specified relative capture width. These methods allow the user to define the WEC's frequency dependent energy absorption as a function of period and/or wave height. SWAN test cases were run to verify the compiled code's functionality, and verification of the frequency dependent WEC Module in SNL-SWAN has also been performed. SNL-SWAN code is will be released as open source code and will be made publicly available.

Source record↗

Power subsystem performance prediction /PSPP/ computer program.

A computer program which simulates the operation of the Viking Orbiter Power Subsystem has been developed. The program simulates the characteristics and interactions of a solar array, battery, battery charge controls, zener diodes, power conditioning equipment, and the battery spacecraft and zener diode-spacecraft thermal interfaces. This program has been used to examine the operation of the Orbiter power subsystem during critical phases of the Viking mission - from launch, through midcourse maneuvers, Mars orbital insertion, orbital trims, Lander separation, solar occultations and unattended operation - until the end of the mission. A typical computer run for the first 24 hours after launch is presented which shows the variations in solar array, zener diode, battery charger, batteries and user load characteristics during this period.

Weiner, H.↗

High Power MPD Thruster Performance Measurements

High power magnetoplasmadynamic (MPD) thrusters are being developed as cost effective propulsion systems for cargo transport to lunar and Mars bases, crewed missions to Mars and the outer planets, and robotic deep space exploration missions. Electromagnetic MPD thrusters have demonstrated, at the laboratory level, the ability to process megawatts of electrical power while providing significantly higher thrust densities than electrostatic electric propulsion systems. The ability to generate higher thrust densities permits a reduction in the number of thrusters required to perform a given mission, and alleviates the system complexity associated with multiple thruster arrays. The specific impulse of an MPD thruster can be optimized to meet given mission requirements, from a few thousand seconds with heavier gas propellants up to 10,000 seconds with hydrogen propellant. In support of programs envisioned by the NASA Office of Exploration Systems, Glenn Research Center is developing and testing quasi-steady MW-class MPD thrusters as a prelude to steady state high power thruster tests. This paper provides an overview of the GRC high power pulsed thruster test facility, and presents preliminary performance data for a quasi-steady baseline MPD thruster geometry.

LaPointe, Michael R.↗

On the Path to SunShot: Advancing Concentrating Solar Power Technology Performance and Dispatchability.

Since the SunShot Vision Study (DOE 2012) was published, global deployment of concentrating solar power (CSP) has increased threefold to nearly 4,500 MW, with a similar threefold increase in operational capacity to 1,650 MW within the United States. Growth in U.S. CSP capacity has primarily been driven by policy support at the state and federal levels. State-driven renewable portfolio standards (RPSs), combined with a 30% federal investment tax credit (ITC) and federal loan guarantees, provided the opportunity for CSP developers to kick-start construction of CSP plants throughout the Southwest. Figure ES-1 demonstrates that deployment and private- and public-sector research and development have led to dramatic cost reductions that have placed CSP well on the path to reaching the U.S. Department of Energy’s SunShot Initiative goal of 6 cents/kWh by 2020. In comparing the estimated capital costs from the SunShot Vision Study and the current analysis, we find that parabolic trough solar-field costs have fallen more rapidly than predicted, although the drop in solar-field costs was offset by the additional costs of moving from a wet-cooled power block in 2010 to a more expensive dry-cooled power block in 2015. The predicted 2015 decline in tower costs was in line with expectations, primarily driven by reduced heliostat costs. Figure ES-1 shows the reduction in levelized cost of electricity (LCOE) for both parabolic trough and tower systems, in addition to the projected 2020 SunShot target.

14 SOLAR ENERGY↗

On the Path to SunShot: Advancing Concentrating Solar Power Technology, Performance, and Dispatchability

Since the SunShot Vision Study (DOE 2012) was published, global deployment of concentrating solar power (CSP) has increased threefold to nearly 4,500 MW, with a similar threefold increase in operational capacity to 1,650 MW within the United States. Growth in U.S. CSP capacity has primarily been driven by policy support at the state and federal levels. State-driven renewable portfolio standards (RPSs), combined with a 30% federal investment tax credit (ITC) and federal loan guarantees, provided the opportunity for CSP developers to kick-start construction of CSP plants throughout the Southwest. Figure ES-1 demonstrates that deployment and private- and public-sector research and development have led to dramatic cost reductions that have placed CSP well on the path to reaching the U.S. Department of Energy’s SunShot Initiative goal of 6 cents/kWh by 2020. In comparing the estimated capital costs from the SunShot Vision Study and the current analysis, we find that parabolic trough solar-field costs have fallen more rapidly than predicted, although the drop in solar-field costs was offset by the additional costs of moving from a wet-cooled power block in 2010 to a more expensive dry-cooled power block in 2015. The predicted 2015 decline in tower costs was in line with expectations, primarily driven by reduced heliostat costs. Figure ES-1 shows the reduction in levelized cost of electricity (LCOE) for both parabolic trough and tower systems, in addition to the projected 2020 SunShot target.

14 SOLAR ENERGY↗

Formulation of advanced consumables management models: Environmental control and electrical power system performance models requirements

Software design specifications for developing environmental control and life support system (ECLSS) and electrical power system (EPS) programs into interactive computer programs are presented. Specifications for the ECLSS program are at the detail design level with respect to modification of an existing batch mode program. The FORTRAN environmental analysis routines (FEAR) are the subject batch mode program. The characteristics of the FEAR program are included for use in modifying batch mode programs to form interactive programs. The EPS program specifications are at the preliminary design level. Emphasis is on top-down structuring in the development of an interactive program.

Daly, J. K.↗

Range Performance of Bombers Powered by Turbine-Propeller Power Plants

Calculations have been made to find range? attainable by bombers of gross weights from l40,000 to 300,000 pounds powered by turbine-propeller power plants. Only conventional configurations were considered and emphasis was placed upon using data for structural and aerodynamic characteristics which are typical of modern military airplanes. An effort was made to limit the various parameters invoked in the airplane configuration to practical values. Therefore, extremely high wing loadings, large amounts of sweepback, and very high aspect ratios have not been considered. Power-plant performance was based upon the performance of a typical turbine-propeller engine equipped with propellers designed to maintain high efficiencies at high-subsonic speeds. Results indicated, in general, that the greatest range, for a given gross weight, is obtained by airplanes of high wing loading, unless the higher cruising speeds associated with the high-wing-loading airplanes require-the use of thinner wing sections. Further results showed the effect of cruising at-high speeds, of operation at very high altitudes, and of carrying large bomb loads.

Cline, Charles W.↗

Uncertainty quantification in the analyses of operational wind power plant performance

In the present work, we examine the variation introduced in the evaluation of an operating plant's wind power production as a result of the choices analysts make in the processing of the operational data. For this study, an idealized power production for individual turbines over an operational period was predicted by fitting power curves to the turbine production data collected during expected operation (that is, without curtailment or availability losses). A set of 240 possible methods were developed for (a) defining what data represented expected operation and (b) modeling the power curve. The spread in the idealized power production as predicted by the different methods was on average almost 3% for the 100 turbines considered. Such significant variation places a lower bound on the precision with which analysts may employ such data as benchmarks for calibration of their energy estimation processes and limits the potential for identification of refinements to the energy estimation models for improved accuracy.

17 WIND ENERGY↗

Impact of Hybrid Wet/Dry Cooling on Concentrating Solar Power Plant Performance

This paper examines the sensitivity of Rankine cycle plant performance to dry cooling and hybrid (parallel) wet/dry cooling combinations with the traditional wet-cooled model as a baseline. Plants with a lower temperature thermal resource are more sensitive to fluctuations in cooling conditions, and so the lower temperature parabolic trough plant is analyzed to assess the maximum impact of alternative cooling configurations. While low water-use heat rejection designs are applicable to any technology that utilizes a Rankine steam cycle for power generation, they are of special interest to concentrating solar power (CSP) technologies that are located in arid regions with limited water availability. System performance is evaluated using hourly simulations over the course of a year at Daggett, CA. The scope of the analysis in this paper is limited to the power block and the heat rejection system, excluding the solar field and thermal storage. As such, water used in mirror washing, maintenance, etc., is not included. Thermal energy produced by the solar field is modeled using NREL's Solar Advisor Model (SAM).

14 SOLAR ENERGY↗

Equivalent Test Bed in PSCAD and PSLF for Studying Advanced Power Systems Controller Performance

With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗