Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase Retrieval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Surface X-Ray Diffraction Results on the III-V Droplet Heteroepitaxy Growth Process for Quantum Dots: Recent Understanding and Open Questions

In recent years, epitaxial growth of self-assembled quantum dots has offered a way to incorporate new properties into existing solid state devices. Although the droplet heteroepitaxy method is relatively complex, it is quite relaxed with respect to the material combinations that can be used. This offers great flexibility in the systems that can be achieved. In this paper we review the structure and composition of a number of quantum dot systems grown by the droplet heteroepitaxy method, emphasizing the insights that these experiments provide with respect to the growth process. Detailed structural and composition information has been obtained using surface X-ray diffraction analyzed by the COBRA phase retrieval method. A number of interesting phenomena have been observed: penetration of the dots into the substrate ('nano-drilling') is often encountered; interdiffusion and intermixing already start when the group III droplets are deposited, and structure and composition may be very different from the one initially intended.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Computational studies of x-ray scattering from three-dimensionally-aligned asymmetric-top molecules

We theoretically and numerically analyze x-ray scattering from asymmetric-top molecules three-dimensionally aligned using elliptically polarized laser light. A rigid-rotor model is assumed. The principal axes of the polarizability tensor are assumed to coincide with the principal axes of the moment of inertia tensor. Several symmetries in the Hamiltonian are identified and exploited to enhance the efficiency of solving the time-dependent Schroedinger equation for each rotational state initially populated in a thermal ensemble. Using a phase-retrieval algorithm, the feasibility of structure reconstruction from a quasiadiabatically aligned sample is illustrated for the organic molecule naphthalene. The spatial resolution achievable strongly depends on the laser parameters, the initial rotational temperature, and the x-ray pulse duration. We demonstrate that for a laser peak intensity of 5 TW/cm{sup 2}, a laser pulse duration of 100 ps, a rotational temperature of 10 mK, and an x-ray pulse duration of 1 ps, the molecular structure may be probed at a resolution of 1 A ring .

74 ATOMIC AND MOLECULAR PHYSICS↗

Phase front retrieval and correction of Bessel beams

Bessel beams generated with non-ideal axicons are affected by aberrations. We introduce a method to retrieve the complex amplitude of a Bessel beam from intensity measurements alone, and then use this information to correct the wavefront and intensity profile using a deformable mirror.

36 MATERIALS SCIENCE↗

Transport of intensity equation: a tutorial

When it comes to “phase measurement” or “quantitative phase imaging”, many people will automatically connect them with “laser” and “interferometry”. Indeed, conventional quantitative phase imaging and phase measurement techniques generally rely on the superposition of two beams with a high degree of coherence: complex interferometric configurations, stringent requirements on the environmental stabilities, and associated laser speckle noise severely limit their applications in optical imaging and microscopy. On a different note, as one of the most well-known phase retrieval approaches, the transport of intensity equation (TIE) provides a new non-interferometric way to access quantitative phase information through intensity only measurement. Despite the insufficiency for interferometry, TIE is applicable under partially coherent illuminations (like the Köhler’s illumination in a conventional microscope), permitting optimum spatial resolution, higher signal-to-noise ratio, and better image quality. In this tutorial, we give an overview of the basic principle, research fields, and representative applications of TIE, focus particularly on optical imaging, metrology, and microscopy. The purpose of this tutorial is twofold. It should serve as a self-contained introduction to TIE for readers with little or no knowledge of TIE. On the other hand, it attempts to give an overview of recent developments in this field. These results highlight a new era in which strict coherence and interferometry are no longer prerequisites for quantitative phase imaging and diffraction tomography, paving the way toward new generation label-free three-dimensional microscopy, with applications in all branches of biomedicine.

42 ENGINEERING↗

Hydrogen density mapping in biomolecular crystals through dynamic nuclear polarization

Many fundamental biological processes, including those in photosynthetic reaction centers and enzyme active sites, involve charge and energy transfer, bond cleavage, protonation and hydrogen bonding. Because H atoms play such central roles in these reactions, accurately determining their positions is essential. Yet, conventional X-ray crystallography primarily resolves the heavy atoms in biological structures and provides limited insight into hydrogen, even at atomic resolution. Neutron macromolecular crystallography (NMC) overcomes this limitation by offering exceptional sensitivity to hydrogen and deuterium. Here, we present a theoretical framework for the development of dynamic nuclear polarization NMC (DNP-NMC) techniques, which exploit the alignment of neutron and proton nuclear spins to enhance and tune the hydrogen signal contribution. The DNP-NMC approach advances the resolution of H atoms within biomolecular crystals, whether bound to protein residues or present in solvent. The method establishes key relationships for the coherent structure factor of polarized neutron scattering from hydrogenous matter. It theoretically achieves full accuracy in phase reconstruction and offers a path to improve neutron structure determination, achieving accuracies exceeding ≳80% by incorporating titration states. Using a variant of the hybrid input/output phase-retrieval algorithm, it allows recovery of the hydrogen density with ≳90% phase accuracy. In conclusion, we further discuss sources of experimental uncertainty for the upcoming DNP-enabled, quasi-Laue IMAGINE-X experiment at Oak Ridge National Laboratory's High Flux Isotope Reactor.

dynamic nuclear polarization↗

High-sensitivity plasma density retrieval in a common-path second-harmonic interferometer through simultaneous group and phase velocity measurement

Precise measurements of the plasma density in ionized gas cells and discharged capillaries are critical to the design and operation of plasma-based accelerators, active plasma lenses, and plasma-based radiation sources. In this manuscript, a spectral-domain common-path second-harmonic interferometer is upgraded with the simultaneous measurement of the group and phase velocity, allowing for high-sensitivity density characterization (from the phase velocity advance) without the need for phase tracking from zero-density (enabled by the group velocity delay). The technique is applied to 1.5-cm-long plasma structures, without density ambiguity in parameter scans with >2π phase jumps. Finally, the single-shot sensitivity in phase retrieval is demonstrated at 63 mrad, equivalent to a density-length product of 1.8·10 15 cm -2 . This is an improvement of ×45 compared to group velocity analysis alone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantized hard-x-ray phase vortices nucleated by aberrated nanolenses

Quantized x-ray phase vortices, namely, screw-type topological defects in the wave fronts of a coherent monochromatic scalar x-ray wave field, may be spontaneously nucleated by x-ray lenses. Phase retrieval is used to reconstruct the phase and amplitude of the complex disturbance created by aberrated gold nanolenses illuminated with hard x rays. A nanoscale quantized x-ray vortex-antivortex dipole is observed, manifest both as a pair of opposite-helicity branch points in the Riemann sheets of the multivalued x-ray phase map of the complex x-ray field and in the vorticity of the associated Poynting vector field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase measurements of EUV mask defects

Extreme Ultraviolet (EUV) Lithography mask defects were examined on the actinic mask imaging system, SHARP, at Lawrence Berkeley National Laboratory. Also, a quantitative phase retrieval algorithm based on the Weak Object Transfer Function was applied to the measured through-focus aerial images to examine the amplitude and phase of the defects. The accuracy of the algorithm was demonstrated by comparing the results of measurements using a phase contrast zone plate and a standard zone plate. Using partially coherent illumination to measure frequencies that would otherwise fall outside the numerical aperture (NA), it was shown that some defects are smaller than the conventional resolution of the microscope. We found that the programmed defects of various sizes were measured and shown to have both an amplitude and a phase component that the algorithm is able to recover.

42 ENGINEERING↗

Phase and amplitude retrieval of objects embedded in a sinusoidal background from its diffraction pattern

Efforts of phase and amplitude retrieval from diffraction patterns have almost exclusively been applied for nonperiodic objects. We investigated the quality of retrieval of nonperiodic objects embedded in a sinusoidal background, using the approach of iterative hybrid input-output with oversampling. Two strategies were employed; one by filtering in the frequency domain prior to phase retrieval, and the other by filtering the phase or amplitude image after retrieval. Results obtained indicate better outcomes with the latter approach provided detector noise is not excessive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallel ptychographic reconstruction

Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps to take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.

97 MATHEMATICS AND COMPUTING↗

Direct determination of one-dimensional interphase structures using normalized crystal truncation rod analysis

Here, a one-dimensional non-iterative direct method was employed for normalized crystal truncation rod analysis. The non-iterative approach, utilizing the Kramers–Kronig relation, avoids the ambiguities due to an improper initial model or incomplete convergence in the conventional iterative methods. The validity and limitations of the present method are demonstrated through both numerical simulations and experiments with Pt(111) in a 0.1 M CsF aqueous solution. The present method is compared with conventional iterative phase-retrieval methods.

36 MATERIALS SCIENCE↗

Coherent diffraction microscopy at SPring-8: instrumentation, data acquisition and data analysis

Since the first demonstration of coherent diffraction microscopy in 1999, this lensless imaging technique has been experimentally refined by continued developments. Here, instrumentation and experimental procedures for measuring oversampled diffraction patterns from non-crystalline specimens using an undulator beamline (BL29XUL) at SPring-8 are presented. In addition, detailed post-experimental data analysis is provided that yields high-quality image reconstructions. As the acquisition of high-quality diffraction patterns is at least as important as the phase-retrieval procedure to guarantee successful image reconstructions, this work will be of interest for those who want to apply this imaging technique to materials science and biological samples.

oversampling↗

Neutron sub-micrometre tomography from scattering data

Neutrons are valuable probes for various material samples across many areas of research. Neutron imaging typically has a spatial resolution of larger than 20 µm, whereas neutron scattering is sensitive to smaller features but does not provide a real-space image of the sample. A computed-tomography technique is demonstrated that uses neutron-scattering data to generate an image of a periodic sample with a spatial resolution of ∼300 nm. The achieved resolution is over an order of magnitude smaller than the resolution of other forms of neutron tomography. This method consists of measuring neutron diffraction using a double-crystal diffractometer as a function of sample rotation and then using a phase-retrieval algorithm followed by tomographic reconstruction to generate a map of the sample's scattering-length density. Topological features found in the reconstructions are confirmed with scanning electron micrographs. This technique should be applicable to any sample that generates clear neutron-diffraction patterns, including nanofabricated samples, biological membranes and magnetic materials, such as skyrmion lattices.

nanoscience↗

2D grating simulation for X-ray phase-contrast and dark-field imaging with a Talbot interferometer

Talbot interferometry is a recently developed and an extremely powerful X-ray phase-contrast imaging technique. Besides giving access to ultra-high sensitivity differential phase contrast images, it also provides the dark field image, which is a map of the scattering power of the sample. In this paper we investigate the potentialities of an improved version of the interferometer, in which two dimensional gratings are used instead of standard line grids. This approach allows to overcome the difficulties that might be encountered in the images produced by a one dimensional interferometer. Among these limitations there are the phase wrapping and quantitative phase retrieval problems and the directionality of the differential phase and dark-field signals. The feasibility of the 2D Talbot interferometer has been studied with a numerical simulation on the performances of its optical components under different circumstances. The gratings can be obtained either by an ad hoc fabrication of the 2D structures or by a superposition of two perpendicular linear grids. Through this simulation it has been possible to find the best parameters for a practical implementation of the 2D Talbot interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

Compressed sensing for phase contrast CT

Modern x-ray techniques opened the possibility to retrieve phase information. Phase-contrast computed tomography (PCCT) has the potential to significantly improve soft tissue contrast. Radiation dose, however, continues to be an issue when moving from bench to bedside. Dose reduction in this work is achieved by sparsely acquiring PCCT data. To compensate for appearing aliasing artifacts we introduce a compressed sensing (CS) reconstruction framework. We present the feasibility of CS on PCCT with numerical as well as measured phantom data. The results proof that CS compensates for under-sampling artifacts and maintains the superior soft tissue contrast and detail visibility in the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Measuring an ultrashort, ultraviolet pulse in a slowly responding, absorbing medium

Frequency-resolved optical gating (FROG) is a common technique for measuring ultrashort laser pulses using an instantaneous, nonlinear-optical interaction as a fast time-gate to measure the pulse intensity and phase. But at high frequencies, materials are often absorbing and it is not always possible to find a medium with a fast nonlinear-optical response. Here we show that an ultrashort, ultraviolet (UV) pulse can be measured in a strongly absorbing medium, using the absorption as the nonlinear-optical time-gate. To do this, we build on our recent implementation of FROG, known as induced-grating cross-correlation FROG (IG XFROG), where an unknown, higher-frequency pulse creates a transient grating that is probed with a lower-frequency, more easily detectable reference pulse. We demonstrate this with an 800 nm reference pulse to characterize 400 nm or 267 nm pulses using ZnS as the nonlinear-optical medium, which is absorptive at and below 400 nm. By scanning the delay between the two UV pulses which create the transient grating, we show that the phase-sensitive instantaneous four-wave-mixing contribution to the nonlinear signal field can be detected and separated from the slower, incoherent part of the response. Measuring a spectrally-resolved cross-correlation in this way and then applying a simple model for the response of the medium, we show that a modified generalized projections (GP) phase-retrieval algorithm can be used to extract the pulse amplitude and phase. We test this approach by measuring chirped UV pulses centered at 400 nm and 267 nm. Since interband absorption (or even photoionization) is not strongly wavelength-dependent, we expect IG XFROG to be applicable deeper into the UV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗