Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photon detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Self-scanned Digicon - A digital image tube for astronomical spectroscopy

We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.

Tull, R. G.↗

Phototransistors For Long-Wavelength Infrared

Phototransistors of proposed new type used to detect photons having wavelengths of 8 to 150 micrometers. Detection based on impurity-to-continuum transitions. Integrated-circuit imaging arrays of such phototransistors useful in infrared remote sensing. Device of this type silicon, germanium, or silicon/germanium phototransistor in which junction between collector and base lightly doped with impurities.

Borenstain, Shmuel I.↗

High-Resolution Thermal X-Ray Detector

Thermal pulses from single photons measured. Detector, consists of X-ray absorber, temperature sensor in absorber, and thermal link from absorber to heat sink. X-ray photon detected by measuring temperature rise immediately following absorption of photon. Thermal X-ray detector, tested successfully in prototype, in theory operates as spectrometer that provides 100 times spectral resolution of conventional to detect trace constituents in materials by X-ray fluorescence. Also used for measuring energies of energetic electrons and weak pulses of light.

Moseley, S. H.↗

Effect of detector dead time on the performance of optical direct-detection communication links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Effect of Detector Dead Time on the Performance of Optical Direct-Detection Communication Links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detect ion sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulted (PPM) channel is studied by analyzing the error probability. It is shown that, when back- ground noise is negligible, the performance of the detector with dead time is similar to that o f a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on background intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Performance of black silicon photodiodes for VUV detection in noble liquids

Black silicon (b-Si) photodiodes are an emerging technology that employs silicon nanostructures to enhance the efficiency of photon detection. Recently, we demonstrated nearly 100% quantum efficiency at <200 nm vacuum ultraviolet (VUV) wavelengths at ambient and in noble liquids, making such devices particularly useful for direct detection of scintillation light in noble liquid detectors. This is important in nuclear science experiments like DarkSide, LUX, XENON, and nEXO, where detection of weak VUV scintillation photons in noble liquids are used to identify rare physics radiation events. Here, we measured the response of b-Si photodiode to the scintillation light generated by alpha particles, all immersed in a LAr and LXe test cell. We established a guideline for future development of b-Si photodetectors with internal gain to reach single-photon sensitivity.

47 OTHER INSTRUMENTATION↗

Lifetime-resolved photon-correlation Fourier spectroscopy

The excited state population of single solid-state emitters is subjected to energy fluctuations around the equilibrium driven by the bath and relaxation through the emission of phonons or photons. Simultaneous measurement of the associated spectral dynamics requires a technique with a high spectral and temporal resolution with an additionally high temporal dynamic range. We propose a pulsed excitation-laser analog of photon-correlation Fourier spectroscopy (PCFS), which extracts the linewidth and spectral diffusion dynamics along the emission lifetime trajectory of the emitter, effectively discriminating spectral dynamics from relaxation and bath fluctuations . This lifetime-resolved PCFS correlates photon-pairs at the output arm of a Michelson interferometer in both their time-delay between laser-excitation and photon-detection T and the time-delay between two photons τ . We propose the utility of the technique for systems with changing relative contributions to the emission from multiple states, for example, quantum emitters exhibiting phonon-mediated exchange between different fine-structure states.

36 MATERIALS SCIENCE↗

A Cross-correlation Study between IceCube Neutrino Events and the FERMI Unresolved Gamma-Ray Sky

With the coincident detections of electromagnetic radiation together with gravitational waves (GW170817) or neutrinos (TXS 0506+056), the new era of multimessenger astrophysics has begun. Of particular interest are the searches for correlation between the high-energy astrophysical neutrinos detected by the IceCube Observatory and gamma-ray photons detected by the Fermi Large Area Telescope (LAT). So far, only sources detected by the LAT have been considered in correlation with IceCube neutrinos, neglecting any emission from sources too faint to be resolved individually. Here we present the first cross-correlation analysis considering the unresolved gamma-ray background (UGRB) and IceCube events. We perform a thorough sensitivity study, and, given the lack of identified correlation, we place upper limits on the fraction of the observed neutrinos that would be produced in proton–proton or proton–$γ$ interactions from the population of sources contributing to the UGRB emission and dominating its spatial anisotropy (aka blazars). Our analysis suggests that, under the assumption that there is no intrinsic cutoff and/or hardening of the spectrum above Fermi-LAT energies, and that all gamma rays from the unresolved blazars dominating the UGRB fluctuation field are produced by neutral pions from $p–p$ ($p–γ$) interactions, up to 60% (30%) of such a population may contribute to the total neutrino events observed by IceCube. This translates into an O (1%) maximum contribution to the astrophysical high-energy neutrino flux observed by IceCube at 100 TeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532 nm photons into time-energy entangled pairs of 800 and 1600 nm photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers also known as a Franson interferometer after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes due to interference between the photon probability amplitudes are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

time-energy entanglement↗

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO - doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532-nanometer photons into time-energy entangled pairs of 800- and 1600-nanometer photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers - also known as a Franson interferometer - after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes - due to interference between the photon probability amplitudes - are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

Time-Energy Entanglement↗

Development of the Nano-HEB Array for Low-Background Far-IR Applications

We present an overview of the recent progress made in the development of a far-IR array of ultrasensitive hot-electronnanobolometers (nano-HEB) made from thin titanium (Ti) films. We studied electrical noise, signal and noisebandwidth, single-photon detection, optical noise equivalent power (NEP), and a microwave SQUID (MSQUID) basedfrequency domain multiplexing (FDM) scheme. The obtained results demonstrate the very low electrical NEP down to1.5x10-(sup 2)? W/Hz(sup 1)/(sup 2) at 50 mK determined by the dominating phonon noise. The NEP increases with temperature as ~ T(sup 3)reaching ~ 10-(sup 1)? W/Hz(sup 1)/(sup 2) at the device critical temperature TC = 330-360 mK. Optical NEP = 8.6x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 357mK and 1.4x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 100 mK respectively, agree with thermal and electrical data. The optical couplingefficiency provided by a planar antenna was greater than 50%. Single 8-?m photons have been detected for the first timeusing a nano-HEB operating at 50-200 mK thus demonstrating a potential of these detectors for future photon-countingapplications in mid-IR and far-IR. In order to accommodate the relatively high detector speed (~ ?s at 300 mK, ~ 100 ?sat 100 mK), an MSQUID based FDM multiplexed readout with GHz carrier frequencies has been built. Both the readoutnoise ~ 2 pA/Hz(sup 1)/(sup 2) and the bandwidth > 150 kHz are suitable for nano-HEB detectors.

single-photon↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection efficiency measurement and operational tests of the X-Arapuca for the first module of DUNE far detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new-speckle interferometry system for the MAMA detector

We have developed a new system for making speckle observations with the multianode microchannel array (MAMA) detector. This system is a true photon-counting imaging device which records the arrival time of every detected photon and allows for reconstruction of image features near the diffraction limit of the telescope. We present a description of the system and summary of observational results obtained at the Lick Observatory 1-m reflector in 1991 September. The diffraction limit of the 1-m telescope at 5029 A is about 0.125 arcsec and we have successfully resolved the catalogued interferometric binary HD 202582 with a separation of 0.157 +/- 0.031 arcsec. A pair of stars in the open cluster Chi Persei separated by 2.65 +/- 0.22 arcsec with approximate V magnitudes 8.6 and 11.5 has also been successfully analyzed with the speckle technique.

Horch, E.↗

Complex Type-II Interband Cascade MQW Photodetectors

Multiple-quantum-well (MQW) photodetectors of a proposed type would contain active regions comprising multiple superlattice subregions. These devices would have complex structures: The superlattice of each subregion would be designed for enhanced absorption of photons in a desired wavelength band (typically in the infrared) and multiple subregions of different design would be cascaded for multicolor operation. The designs of these photodetectors would take advantage of the characteristic alignment of the edges of the electron-energy bands in type-II quantum-well structures: Within each finite superlattice, interband transitions would be used for detecting photons, and between finite superlattices, intraband relaxation and interband tunneling would be used for transport of charge carriers, all such as to enable detection of normally incident photons. Absorption of photons in the active region of a photodetector according to the proposal could be significantly enhanced by designing the superlattice/MQW structures to contain closely spaced energy states. The photodetector could be operated with a small bias to facilitate transport of charge carriers. The superlattices could be somewhat chirped, with a preferred transport direction.

Yang, Rui↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of TeV photons from the active galaxy Markarian 421

The detection of TeV energy photons from the giant elliptical galaxy Markarian 421 using the Whipple Observatory gamma-ray telescope is reported. The signal has a statistical significance of 6 sigma above background and the flux above 0.5 TeV is 0.3 of that from the Crab Nebula. The source location agrees with the position of Mk 421 within the angular uncertainty of the Whipple instrument.

Punch, M.↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗