First beam measurements on the vessel for extraction and source plasma analyses (VESPA) at the Rutherford Appleton Laboratory (RAL)

In order to facilitate the testing of advanced H{sup −} ion sources for the ISIS and Front End Test Stand (FETS) facilities at the Rutherford Appleton Laboratory (RAL), a Vessel for Extraction and Source Plasma Analyses (VESPA) has been constructed. This will perform the first detailed plasma measurements on the ISIS Penning-type H{sup −} ion source using emission spectroscopic techniques. In addition, the 30-year-old extraction optics are re-designed from the ground up in order to fully transport the beam. Using multiple beam and plasma diagnostics devices, the ultimate aim is improve H{sup −} production efficiency and subsequent transport for either long-term ISIS user operations or high power FETS requirements. The VESPA will also accommodate and test a new scaled-up Penning H{sup −} source design. This paper details the VESPA design, construction and commissioning, as well as initial beam and spectroscopy results.

43 PARTICLE ACCELERATORS↗

Large-Area Permanent-Magnet ECR Plasma Source

A 40-cm-diameter plasma device has been developed as a source of ions for material-processing and ion-thruster applications. Like the device described in the immediately preceding article, this device utilizes electron cyclotron resonance (ECR) excited by microwave power in a magnetic field to generate a plasma in an electrodeless (noncontact) manner and without need for an electrically insulating, microwave-transmissive window at the source. Hence, this device offers the same advantages of electrodeless, windowless design - low contamination and long operational life. The device generates a uniform, high-density plasma capable of sustaining uniform ion-current densities at its exit plane while operating at low pressure [<10(exp -4) torr (less than about 1.3 10(exp -2) Pa)] and input power <200 W at a frequency of 2.45 GHz. Though the prototype model operates at 2.45 GHz, operation at higher frequencies can be achieved by straightforward modification to the input microwave waveguide. Higher frequency operation may be desirable in those applications that require even higher background plasma densities. In the design of this ECR plasma source, there are no cumbersome, power-hungry electromagnets. The magnetic field in this device is generated by a permanent-magnet circuit that is optimized to generate resonance surfaces. The microwave power is injected on the centerline of the device. The resulting discharge plasma jumps into a "high mode" when the input power rises above 150 W. This mode is associated with elevated plasma density and high uniformity. The large area and uniformity of the plasma and the low operating pressure are well suited for such material-processing applications as etching and deposition on large silicon wafers. The high exit-plane ion-current density makes it possible to attain a high rate of etching or deposition. The plasma potential is <3 V low enough that there is little likelihood of sputtering, which, in plasma processing, is undesired because it is associated with erosion and contamination. The electron temperature is low and does not vary appreciably with power.

Foster, John E.↗

HEAVY ION FUSION SCIENCE VIRTUAL NATIONAL LABORATORY 3nd QUARTER 2009 MILESTONE REPORT: Upgrade plasma source configuration and carry out initial experiments. Characterize improvements in focal spot beam intensity

Simulations suggest that the plasma density must exceed the beam density throughout the drift compression and focusing section in order to inhibit the space charge forces that would limit the spot size and beam intensity on the target. WDM experiments will therefore require plasma densities up to 10{sup 14}/cm{sup 3}, with the highest density in the last few centimeters before the target. This work was guided by the simulations performed for the FY09 Q1 milestone. This milestone has been met and we report results of modifications made to the NDCX beamline to improve the longitudinal and radial distribution of the neutralizing plasma in the region near the target plane. In Section 2, we review pertinent simulation results from the FY09 Q1 milestone. Section 3 describes the design, and beam measurements following installation, of a biased, self-supporting metal grid that produces neutralizing electrons from glancing interception of beam ions. Section 4 describes the design and initial testing of a compact Ferro-Electric Plasma Source (FEPS) that will remove the remaining 'exclusion zone' in the neutralizing plasma close to the target plane. Section 5 describes the modification of the beamline to decrease the gap between the FEPS section exit and the final focus solenoid (FFS). Section 6 presents a summary and conclusions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High average power, highly brilliant laser-produced plasma source for soft X-ray spectroscopy

In this work, a novel laser-produced plasma source is presented which delivers pulsed broadband soft X-radiation in the range between 100 and 1200 eV. The source was designed in view of long operating hours, high stability, and cost effectiveness. It relies on a rotating and translating metal target and achieves high stability through an on-line monitoring device using a four quadrant extreme ultraviolet diode in a pinhole camera arrangement. The source can be operated with three different laser pulse durations and various target materials and is equipped with two beamlines for simultaneous experiments. Characterization measurements are presented with special emphasis on the source position and emission stability of the source. As a first application, a near edge X-ray absorption fine structure measurement on a thin polyimide foil shows the potential of the source for soft X-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray-spectroscopy analysis of electron-cyclotron-resonance ion-source plasmas

Analysis of x-ray spectra emitted by highly charged ions in an electron-cyclotron-resonance ion source (ECRIS) may be used as a tool to estimate the charge-state distribution (CSD) in the source plasma. For that purpose, knowledge of the electron energy distribution in the plasma, as well as the most important processes leading to the creation and de-excitation of ionic excited states are needed. In this work we present a method to estimate the ion CSD in an ECRIS through the analysis of the x-ray spectra emitted by the plasma. The method is applied to the analysis of a sulfur ECRIS plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetospheric plasma - Sources, wave-particle interactions and acceleration mechanisms.

Some of the basic problems associated with magnetospheric physics are reviewed. The sources of magnetospheric plasma, with auroral particles included as a subset, are discussed. The possible ways in which the solar wind plasma can gain access to the magnetosphere are outlined. Some important consequences of wave-particle interactions are examined. Finally, the basic mechanisms which energize or accelerate particles by reconnection and convection are explained.

Speiser, T. W.↗

Betatron radiation from a beam driven plasma source

Photons produced by the betatron oscillation of electrons in a beam-driven plasma wake provide a uniquely intense and high-energy source of hard X-rays and gamma rays. This betatron radiation is interesting not only for its high intensity and spectral characteristics, but also because it can be used as a diagnostic for beam matching into the plasma, which is critical for maximizing the energy extraction efficiency of a plasma accelerator stage. At SLAC, gamma ray detection devices have been installed at the dump area of the FACET beamline where the betatron radiation from the plasma source used in the E200 plasma wakefield acceleration experiment may be observed. The ultra-dense, high-energy beam at FACET (2 Multiplication-Sign 10{sup 10} electrons, 20 Multiplication-Sign 20{mu}m{sup 2} spot, 20 - 100{mu}m length, 20GeV energy) when sent into a plasma source with a nominal density of {approx} 1 Multiplication-Sign 10{sup 17} cm{sup -3} will generate synchrotron-like spectra with critical energies well into the tens of MeV. The intensity of the radiation can be increased by introducing a radial offset to the centroid of the witness bunch, which may be achieved at FACET through the use of a transverse deflecting RF cavity. The E200 gamma ray detector has two main components: a 30 Multiplication-Sign 35cm{sup 2} phosphorescent screen for observing the transverse extent of the radiation, and a sampling electromagnetic calorimeter outfitted with photodiodes for measuring the on-axis spectrum. To estimate the spectrum, the observed intensity patterns across the calorimeter are fit with a Gaussian-integrated synchrotron spectrum and compared to simulations. Results and observations from the first FACET user run (April-June 2012) are presented.

43 PARTICLE ACCELERATORS↗

Betatron Radiation from a Beam Driven Plasma Source

Photons produced by the betatron oscillation of electrons in a beam-driven plasma wake provide a uniquely intense and high-energy source of hard X-rays and gamma rays. This betatron radiation is interesting not only for its high intensity and spectral characteristics, but also because it can be used as a diagnostic for beam matching into the plasma, which is critical for maximizing the energy extraction efficiency of a plasma accelerator stage. At SLAC, gamma ray detection devices have been installed at the dump area of the FACET beamline where the betatron radiation from the plasma source used in the E200 plasma wakefield acceleration experiment may be observed. The ultra-dense, high-energy beam at FACET (2 x 10{sup 10} electrons, 20 x 20 {micro}m{sup 2} spot, 20-100 {micro}m length, 20 GeV energy) when sent into a plasma source with a nominal density of {approx} 1 x 10{sup 17} cm{sup -3} will generate synchrotron-like spectra with critical energies well into the tens of MeV. The intensity of the radiation can be increased by introducing a radial offset to the centroid of the witness bunch, which may be achieved at FACET through the use of a transverse deflecting RF cavity. The E200 gamma ray detector has two main components: a 30 x 35 cm{sup 2} phosphorescent screen for observing the transverse extent of the radiation, and a sampling electromagnetic calorimeter outfitted with photodiodes for measuring the on-axis spectrum. To estimate the spectrum, the observed intensity patterns across the calorimeter are fit with a Gaussian-integrated synchrotron spectrum and compared to simulations. Results and observations from the first FACET user run (April-June 2012) are presented.

43 PARTICLE ACCELERATORS↗

Material impacts and heat flux characterization of an electrothermal plasma source with an applied magnetic field

To produce a realistic tokamak-like plasma environment in linear plasma device, a transient source is needed to deliver heat and particle fluxes similar to those seen in an edge localized mode (ELM). ELMs in future large tokamaks will deliver heat fluxes of ~1 GW/m 2 to the divertor plasma facing components at a few Hz. An electrothermal plasma source can deliver heat fluxes of this magnitude. These sources operate in an ablative arc regime which is driven by a DC capacitive discharge. An electrothermal source was configured in this paper with two pulse lengths and tested under a solenoidal magnetic field to determine the resulting impact on liner ablation, plasma parameters, and delivered heat flux. The arc travels through and ablates a boron nitride liner and strikes a tungsten plate. Finally, the tungsten target plate is analyzed for surface damage using a scanning electron microscope.

36 MATERIALS SCIENCE↗

Combinatorial characterization of transparent conductive properties of Ga-doped ZnO films cosputtered from electron cyclotron resonance and rf magnetron plasma sources

The simultaneous sputtering of ZnO and Ga{sub 2}O{sub 3} by electron cyclotron resonance and rf magnetron plasma sources produced Ga-doped ZnO (GZO) films with continuously varying Ga concentration over the substrate surface. Combinatorial evaluation of electrical and optical properties of GZO film grown on silica glass substrate without heater annealing enabled identification of minimum resistivity (0.5 m{Omega} cm) at a Ga{sub 2}O{sub 3} content of 5.5 wt % with an optical transmittance of 90% in the visible wavelength. The monotonically decreasing mobility that was associated with increasing carrier concentration as Ga{sub 2}O{sub 3} content was increased indicated that conduction was governed by ionized impurity scattering. Above the critical Ga{sub 2}O{sub 3} content (6 wt %), carrier concentration decreased since excess Ga atoms that were incorporated beyond the solubility limit at Zn sites hindered large crystalline domains from forming. The ZnO (002) x-ray diffraction peak was suppressed and peaks assigned to Ga{sub 2}O{sub 3} were observed at high Ga{sub 2}O{sub 3} content. The optimum Ga{sub 2}O{sub 3} content shifted to 3.5 wt % at a deposition temperature of 200 deg. C and 2.5 wt % at 300 deg. C, and the minimum resistivity was further decreased to 0.28 m{Omega} cm at 200 deg. C. However, the resistivities at these elevated temperatures were incredibly high both at the lower and higher side of the optimum Ga{sub 2}O{sub 3} content.

36 MATERIALS SCIENCE↗

Ions Beams and Ferroelectric Plasma Sources

Near-perfect space-charge neutralization is required for the transverse compression of high perveance ion beams for ion-beam-driven warm dense matter experiments, such as the Neutralized Drift Compression eXperiment (NDCX). Neutralization can be accomplished by introducing a plasma in the beam path, which provides free electrons that compensate the positive space charge of the ion beam. In this thesis, charge neutralization of a 40~keV, perveance-dominated Ar$^+$ beam by a Ferroelectric Plasma Source (FEPS) is investigated. First, the parameters of the ion beam, such as divergence due to the extraction optics, charge neutralization fraction, and emittance were measured. The ion beam was propagated through the FEPS plasma, and the effects of charge neutralization were inferred from time-resolved measurements of the transverse beam profile. In addition, the dependence of FEPS plasma parameters on the configuration of the driving pulser circuit was studied to optimize pulser design. An ion accelerator was constructed that produced a 30-50~keV Ar$^+$ beam with pulse duration $<$300~$\mu$s and dimensionless perveance $Q$ up to 8$\times$10$^{-4}$. Transverse profile measurements 33~cm downstream of the ion source showed that the dependence of beam radius on $Q$ was consistent with space charge expansion. It was concluded that the beam was perveance-dominated with a charge neutralization fraction of approximately zero in the absence of neutralizing plasma. Since beam expansion occurred primarily due to space charge, the decrease in effective perveance due to neutralization by FEPS plasma can be inferred from the reduction in beam radius. Results on propagation of the ion beam through FEPS plasma demonstrate that after the FEPS is triggered, the beam radius decreases to its neutralized value in about 5~$\mu$s. The duration of neutralization was about 10~$\mu$s at a charging voltage $V_{FEPS}$~=~5.5~kV and 35~$\mu$s at $V_{FEPS}$~=~6.5~kV. With $V_{FEPS}$~=~6.5~kV, the transverse current density profile 33~cm downstream of the source had a Gaussian shape with $x_{rms}$=5~mm, which corresponds to a half-angle divergence of 0.87$^\circ$. The measurements show that near-perfect charge neutralization with FEPS can be attained. No loss of ion beam current was detected, indicating the absence of a neutral cloud in the region of beam propagation, which would cause beam loss to charge exchange collisions. This provides evidence in favor of using FEPS in a future Heavy Ion Fusion accelerator. The FEPS discharge was investigated based on current-voltage measurements in the pulser circuit. Different values of series resistance and storage capacitance in the pulser circuit were used. The charged particle current emitted by the FEPS into vacuum was measured from the difference in forward and return currents in the driving circuit. It was found that FEPS is an emitter of negative charge, and that electron current emission begins approximately 0.5~$\mu$s after the fast-rising high voltage pulse is applied and lasts for tens of $\mu$s. The value of the series resistance in the pulser circuit was varied to change the rise time of the voltage pulse; plasma density was expected to decrease with increasing values of resistance. However, the data showed that changing the resistance had no significant effect. The average charge emitted per shot depends strongly on the value of the storage capacitance. Lowering the capacitance from 141~nF to 47~nF resulted in a near-complete shut-off of charge emission, although the amplitude of the applied voltage pulse was as high, and rise time as short, as when high-density plasma was produced. Increasing the capacitance from 141~nF to 235~nF increased the average charge emitted per shot by a factor of$~$2.

ferroelectric plasma source↗

Comparison of an Electrothermal Plasma Source to a Light Gas Gun for Launching Large Cryogenic Pellets for Tokamak Disruption Mitigation

Future large tokamaks, such as ITER, will require a reliable technique for rapid energy dissipation to mitigate harmful effects from disruptions. Two main methods developed for disruption mitigation are massive gas injection and shattered pellet injection (SPI). Argon and neon are favorable materials for both injection methods. When launching pellets with SPI, it has proven difficult to launch intact pellets of pure argon and/or neon owing to their high material strength at cryogenic temperatures. In this work, we compare two methods of launching relatively high-Z pellets. An electrothermal plasma source is an experimental alternative to the fast opening, high-pressure, gas valve. The electrothermal source was used to launch Lexan™ pellets with approximately the same size and mass of comparable mixed gas (D 2 and Ne) cryogenic pellets launched by gas guns. As a result, we describe comparisons of achieved pellet velocities, energy efficiencies of each system, and the implications of implementing each respective method on an operating tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Plasma Source as an MHD Model for Astrophysical Jets

The significance of the work described herein lies in the demonstration of Magnetized Coaxial Plasma Gun (MCG) devices like CPS-1 to produce energetic laboratory magneto-flows with embedded magnetic fields that can be used as a simulation tool to study flow interaction dynamic of jet flows, to demonstrate the magnetic acceleration and collimation of flows with primarily toroidal fields, and study cross field transport in turbulent accreting flows. Since plasma produced in MCG devices have magnetic topology and MHD flow regime similarity to stellar and extragalactic jets, we expect that careful investigation of these flows in the laboratory will reveal fundamental physical mechanisms influencing astrophysical flows. Discussion in the next section (sec.2) focuses on recent results describing collimation, leading flow surface interaction layers, and turbulent accretion. The primary objectives for a new three year effort would involve the development and deployment of novel electrostatic, magnetic, and visible plasma diagnostic techniques to measure plasma and flow parameters of the CPS-1 device in the flow chamber downstream of the plasma source to study, (1) mass ejection, morphology, and collimation and stability of energetic outflows, (2) the effects of external magnetization on collimation and stability, (3) the interaction of such flows with background neutral gas, the generation of visible emission in such interaction, and effect of neutral clouds on jet flow dynamics, and (4) the cross magnetic field transport of turbulent accreting flows. The applicability of existing laboratory plasma facilities to the study of stellar and extragalactic plasma should be exploited to elucidate underlying physical mechanisms that cannot be ascertained though astrophysical observation, and provide baseline to a wide variety of proposed models, MHD and otherwise. The work proposed herin represents a continued effort on a novel approach in relating laboratory experiments to astrophysical jet observation. There exists overwhelming similarity among these flows that has already produced some fascinating results and is expected to continue a high pay off in future flow similarity studies.

Mayo, Robert M.↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct photoetching of polymers using radiation of high energy density from a table-top extreme ultraviolet plasma source

In order to perform material interaction studies with intense extreme ultraviolet (EUV) radiation, a Schwarzschild mirror objective coated with Mo/Si multilayers was adapted to a compact laser-driven EUV plasma source utilizing a solid Au target. By 10x demagnified imaging of the plasma a maximum pulse energy density of {approx}0.73 J/cm{sup 2} at a wavelength of 13.5 nm can be achieved in the image plane of the objective at a pulse duration of 8.8 ns. In this paper we present EUV photoetching rates measured for polymethyl methacrylate, polycarbonate, and polytetrafluoroethylene at various fluence levels. A linear dependence between etch depth and applied EUV pulse number could be observed without the necessity for any incubation pulses. By evaluating the slope of these data, etch rates were determined, revealing also a linear behavior for low fluences. A threshold energy density could not be observed. The slope of the linear etch regime as well as deviations from the linear trend at higher energy densities are discussed and compared to data known from deep UV laser ablation. Furthermore, the surface roughness of the structured polymers was measured by atomic force microscopy and compared to the nonirradiated polymer surface, indicating a rather smooth etch process (roughness increase of 20%-30%). The different shapes of the etch craters observed for the three polymers at high energy densities can be explained by the measured fluence dependence of the etch rates, having consequences for the proper use of polymer ablation for beam profiling of focused EUV radiation.

36 MATERIALS SCIENCE↗

Absolute and relative emission spectroscopy study of 3 cm wide planar radio frequency atmospheric pressure bio-plasma source

The dynamics of low power atmospheric pressure radio frequency discharge generated in Ar gas in long gap of 3 cm is investigated. This plasma source is characterized and analyzed for possible large scale biomedical applications where low gas temperature and potential-less effluent are required. The discharge forms a homogenous glow-like afterglow in ambient air at input power of 30 W with low gas temperature of 330 K, which is desirable in biomedical applications. With absolute calibrated spectroscopy of the discharge, electron density of 0.4 × 10{sup 18} m{sup −3} and electron temperature of 1.5 eV are obtained from continuum Bremsstrahlung radiation of the source. Time and spatial resolved emission spectroscopy is used to analyze discharge generation mechanism and active species formation. It is found that discharge dynamics strongly correlates with the discharge current waveform. Strong Ar(2p) excited states emission is observed nearby the electrodes surface on a distance up to 200 μm in the plasma sheath region at 10 ns after the current peak, whereas OH(A) emission is uniform along of the interelectrode gap.