Search NASA⌕ Search

SEARCH · Search NASA

Results for “Platform Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

6DOF Testing of the SLS Inertial Navigation Unit

The Navigation System on the NASA Space Launch System (SLS) Block 1 vehicle performs initial alignment of the Inertial Navigation System (INS) navigation frame through gyrocompass alignment (GCA). In lieu of direct testing of GCA accuracy in support of requirement verification, the SLS Navigation Team proposed and conducted an engineering test to, among other things, validate the GCA performance and overall behavior of the SLS INS model through comparison with test data. This paper will detail dynamic hardware testing of the SLS INS, conducted by the SLS Navigation Team at Marshall Space Flight Center's 6DOF Table Facility, in support of GCA performance characterization and INS model validation. A 6-DOF motion platform was used to produce 6DOF pad twist and sway dynamics while a simulated SLS flight computer communicated with the INS. Tests conducted include an evaluation of GCA algorithm robustness to increasingly dynamic pad environments, an examination of GCA algorithm stability and accuracy over long durations, and a long-duration static test to gather enough data for Allan Variance analysis. Test setup, execution, and data analysis will be discussed, including analysis performed in support of SLS INS model validation.

Geohagan, Kevin W.↗

Assessments of Physiology and Cognition in Hybrid-Reality Environments (APACHE) – A VR “Sandbox” for Planetary Spacewalk Research

NASA is planning to return to the Moon in the mid-2020s as a steppingstone to Mars missions in the 2030s. Spacewalks, or extravehicular activities (EVAs), performed on the Moon and Mars will differ in a variety of ways from those that have been performed in decades past. NASA has identified multiple risks to human health and performance associated with a crewed mission to Mars, especially those associated with exploration EVAs which are expected to be a primary mission activity. Crew may be expected to conduct up to 24 hours of EVA per person per week, where the likelihood of injury and/or mental mistakes are increased compared to ground-based training or current microgravity EVAs and the consequences of which can be catastrophic. Current test environments for exploration EVA research and technology development are large, costly facilities that are limited in their availability or capabilities. Spacesuit testing in a reduced gravity environment such as NASA’s Neutral Buoyancy Laboratory, while a good representation of the crew’s physical workload during exploration EVAs, typically has small datasets and is difficult to integrate physiological sensors or other types of crew performance measures. Meanwhile, scientific field-based testing such as NASA’s Desert Research and Technology Studies offers an operationally relevant environment for exploration EVAs, particularly for cognitive workload, but is also limited by small datasets, lack of a pressurized spacesuit, and obtrusive measures. The limitations of current analogs for exploration EVAs identify a need for a new test environment that can approximate both the physical and cognitive demands associated with exploration EVAs to enable rapid, controlled, and repeatable evaluations of human health and performance risks of exploration missions. In response, the Human Physiology, Performance, Protection, and Operations Laboratory (H-3PO) at NASA Johnson Space Center has developed a hybrid reality exploration EVA analog named the Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE)[ to address these limitations using a combination of virtual, physical, and hybrid reality techniques. The APACHE facility resides at NASA Johnson Space Center and serves as a large “sandbox” for EVA research and simulation. At its center is a roughly 15x20ft space surrounded by a 14” tall sandbox partially filled with lunar regolith simulant to emulate the physical feeling of walking on a planetary surface and to allow for simulated geology operations. Nearby, a curved passive treadmill (Skillmill Connect, Technogym, Fairfield, NJ) and an omnidirectional treadmill (Infinadeck, Infinadeck, Rocklin, CA) are included to enable exploration of these large virtual environments while also imposing the physical demands, representative timelines, and cognitive burdens required to navigate and traverse these distances during exploration EVA. A 6DOF motion platform is used to simulate rover operations and supports various human performance evaluations and associated risks. Lastly, APACHE can support two extravehicular (EV) crewmembers working in tandem. A computer workstation is located nearby and also supports an intravehicular (IV) crewmember as part of a full mission simulation. The IV crewmember has direct video and audio communication with the EV crew in VR to provide operational and procedural support.

Human Performance↗

Assessments of Physiology and Cognition in Hybrid-Reality Environments (APACHE)

NASA is planning to return to the Moon in the mid-2020s as a stepping stone to Mars missions in the 2030s. Spacewalks, or extravehicular activities (EVAs), performed on the Moon and Mars will differ in a variety of ways from those that have been performed in decades past. NASA has identified multiple risks to human health and performance associated with a crewed mission to Mars, especially those associated with exploration EVAs which are expected to be a primary mission activity. Crew may be expected to conduct up to 24 hours of EVA per person per week, where the likelihood of injury and/or mental mistakes are increased compared to ground-based training or current microgravity EVAs and the consequences of which can be catastrophic. Current test environments for exploration EVA research and technology development are large, costly facilities that are limited in their availability or capabilities. Spacesuit testing in a reduced gravity environment such as NASA’s Neutral Buoyancy Laboratory, while a good representation of the crew’s physical workload during exploration EVAs, typically has small datasets and is difficult to integrate physiological sensors or other types of crew performance measures. Meanwhile, scientific field-based testing such as NASA’s Desert Research and Technology Studies offers an operationally relevant environment for exploration EVAs, particularly for cognitive workload, but is also limited by small datasets, lack of a pressurized spacesuit, and obtrusive measures. The limitations of current analogs for exploration EVAs identify a need for a new test environment that can approximate both the physical and cognitive demands associated with exploration EVAs to enable rapid, controlled, and repeatable evaluations of human health and performance risks of exploration missions. In response, the Human Physiology, Performance, Protection, and Operations Laboratory (H-3PO) at NASA Johnson Space Center has developed a hybrid reality exploration EVA analog named the Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE) to address these limitations using a combination of virtual, physical, and hybrid reality techniques. The APACHE facility resides at NASA Johnson Space Center and serves as a large “sandbox” for EVA research and simulation. At its center is a roughly 15x20ft space surrounded by a 14” tall sandbox partially filled with lunar regolith simulant to emulate the physical feeling of walking on a planetary surface and to allow for simulated geology operations. Nearby, a curved passive treadmill (Skillmill Connect, Technogym, Fairfield, NJ) and an omnidirectional treadmill (Infinadeck, Infinadeck, Rocklin, CA) are included to enable exploration of these large virtual environments while also imposing the physical demands, representative timelines, and cognitive burdens required to navigate and traverse these distances during exploration EVA. A 6DOF motion platform is used to simulate rover operations and supports various human performance evaluations and associated risks. Lastly, APACHE can support two extravehicular (EV) crewmembers working in tandem. A computer workstation is located nearby and also supports an intravehicular (IV) crewmember as part of a full mission simulation. The IV crewmember has direct video and audio communication with the EV crew in VR to provide operational and procedural support. The software used in APACHE was created by the JSC Engineering Directorate, in partnership with Buendea, powered by a custom Unreal Engine 5 (UE5.3, Epic Games) project. APACHE currently utilizes the HTC Vive Pro Eye in a wireless configuration for VR simulations. There are two virtual environments that subjects can explore within APACHE, a Lunar and Martian surface. The virtual Lunar surface was created from LIDAR data of the Lunar South Pole to create roughly 16 sq km of explorable terrain. The virtual Martian surface contains roughly 400 sq km of explorable terrain derived from Mars Reconnaissance Orbiter LIDAR data of the Jezero Crater. The immersion and related cognitive burdens of conducting a planetary EVA is simulated through a series of EVA-relevant tasks performed in the VR environment, using these high-fidelity visual representations. Additionally, APACHE includes biosensor driven informatics, such as real-time heart rate monitoring and/or derived values from model simulations, for active monitoring by the EV crew and added cognitive demand. A “Wizard of Oz” control panel enables test operators to activate contingency events such as simulated spacesuit malfunctions, loss of communications, and/or limited visibility. Embedded performance measures such as accuracy, completeness, and execution time have been developed for various exploration tasks to objectively quantify crew performance during an EVA and compare impacts to performance when different environmental stressors, both physical and cognitive, are added to or removed from the simulation. Additionally, validated cognitive and operational performance measures such as the Digit Symbol Substitution Task have been recreated and embedded in VR for direct and relatively unobtrusive measurement of motor perception. The APACHE environment currently supports multiple research studies at NASA. Examples include the CHAPEA project, a series of simulated year-long missions on Mars by a 4-person crew; and the CO2 Contingency Walk Back Study, an investigation of elevated CO2 exposure on crew performance during a contingency EVA scenario. APACHE also provides a test environment to support the development of the Crew State and Risk Model, which is a collection of individualized, mathematical models of crew physical and cognitive state; and the Personalized EVA Informatics and Decision Support system, an operational tool for flight controllers, and eventually a self-reliant Martian crew, to make biomedically-informed decisions in real-time to optimize the EVA planning and execution with respect to crew health and performance. Some technical challenges associated with developing the APACHE environment, as well as current limitations, include VR limitless natural walking with a hybrid spacesuit simulator, optimizing performance for wireless PC VR streaming while maintaining a high degree of visual fidelity, and the integration of various physiological (metabolic masks) and psychometric (eye tracking) sensors with the VR headset.

Human Performance↗

SU-E-J-45: Design and Study of An In-House Respiratory Gating Phantom Platform for Gated Radiotherapy

Purpose: The main purpose of this work was to develop an in-house low cost respiratory motion phantom platform for testing the accuracy of the gated radiotherapy system and analyze the dosimetric difference during gated radiotherapy. Methods: An in-house respiratory motion platform(RMP) was designed and constructed for testing the targeting accuracy of respiratory tracking system. The RMP consist of acrylic Chest Wall Platform, 2 DC motors, 4 IR sensors, speed controller circuit, 2 LED and 2 moving rods inside the RMP. The velocity of the movement can be varied from 0 to 30 cycles per minute. The platform mounted to a base using precision linear bearings. The base and platform are made of clear, 15mm thick polycarbonate plastic and the linear ball bearings are oriented to restrict the platform to a movement of approximately 50mm up and down with very little friction. Results: The targeting accuracy of the respiratory tracking system was evaluated using phantom with and without respiratory movement with varied amplitude. We have found the 5% dose difference to the PTV during the movement in comparison with stable PTV. The RMP can perform sinusoidal motion in 1D with fixed peak to peak motion of 5 to 50mm and cycle interval from 2 to 6 seconds. The RMP was designed to be able to simulate the gross anatomical anterior posterior motion attributable to respiration-induced motion of the thoracic region. Conclusion: The unique RMP simulates breathing providing the means to create a comprehensive program for commissioning, training, quality assurance and dose verification of gated radiotherapy treatments. Create the anterior/posterior movement of a target over a 5 to 50 mm distance to replicate tumor movement. The targeting error of the respiratory tracking system is less than 1.0 mm which shows suitable for clinical treatment with highly performance.

60 APPLIED LIFE SCIENCES↗

Lunar Rover Motion-Based Simulation System

Our team developed a motion-based simulation system for lunar terrain vehicles which resides at Johnson Space Center’s Systems Engineering Simulator (SES) facility. This activity integrates existing fixed base simulation capabilities with a newly procured motion base platform for the design, development, evaluation, and training associated with lunar terrain vehicles. This incorporates a South Pole Lunar virtual reality simulation, combined with a pair of VR headsets, integrated within a rover cockpit on a motion platform for evaluating human performance and vehicle handling qualities for concept roving vehicle designs for surface mobility operations.

Motion-Based↗

Effects of the motions of a platform-mounted payload on the nutational stability of a dual-spin spacecraft - A Galileo case study

In the presence of spacecraft nutation, tracking of an inertially fixed target by the Galileo scan platform requires the use of two control loops to move the scan platform and the stator in such a way as to compensate for spacecraft motion. The effect of these control loops on spacecraft nutational stability is examined using an eigenvalue analysis approach as well as several computer analysis packages. It was found that the actions of these control loops tend to drive nutation to the point of neutralizing, and even overpowering the damping actions of the spacecraft nutation damper, for pointing directions close to the spacecraft's poles. Stable and unstable zones are mapped out for two sets of spacecraft mass properties, and contributions of rotor asymmetry and stator flexibility are also discussed.

Man, G. K.↗

Learning-Based State-Dependent Coefficient Form Task Space Tracking Control of Soft Robot

n this paper, a data-driven modeling and control framework is developed for task space control of a soft robot gripper which consists of four individual soft fingers. Each of the four fingers is modeled as a manipulator with high degrees of freedom. The corresponding task space dynamics of the manipulator are derived using a rigid-link approximation of the continuum manipulator. A neural network approach is used to learn the derived dynamics in State Dependent Coefficient (SDC) form. Using the learned SDC matrices, an asymptotically stable optimal closed-loop tracking controller which is based on solving the State Dependent Riccati Equation (SDRE) is derived. The model learning and trajectory tracking controller is implemented on an open source Soft Motion (SoMo) platform simulating the soft gripper motion and corresponding tracking results are presented.

Rounak Bhattacharya↗

1:70-Scale Model Testing of the Reference OpenSource Controller (ROSCO) on the IEA-Wind 15MW Reference Wind Turbine Including Floating Feedback: Preprint

This paper presents results from the Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental campaign performed at the University of Maine's (UMaine's) Harold Alfond Wind/Wave Ocean Engineering Laboratory (W2). The project involves four Froude-scaled test campaigns considering the International Energy Agency (IEA) Wind 15MW Reference Wind Turbine deployed on the VolturnUS-S semi-submersible platform with tuned-mass damper (TMD) elements in the hull. The turbine employs real-time rotor torque and blade pitch control through the Reference OpenSource Controller (ROSCO), including the additional control strategies of ROSCO's thrust peak shaving and a floating feedback control loop. Results with the floating feedback control are considered in this paper and show a significant reduction in platform pitch motion and loads around the platform pitch natural frequency with minimal negative impact of rotor power quality.

controls↗

OpenFAST simulation of floating wind turbines with large heading change

Previous versions of OpenFAST, the physics-based wind turbine engineering and design tool developed by the National Renewable Energy Laboratory, were limited to small rotations of the floating platform. This prevented OpenFAST from being used to simulate important events, such as the loss of a mooring line, or specific floater concepts that might experience large platform yaw motion. To overcome this limitation, we modify the structural dynamics and hydrodynamics modules of OpenFAST to allow unrestricted platform yaw motion. We apply the improved version of OpenFAST to simulate the drifting of a floating wind turbine system after the loss of a mooring line. The results, including both global motion and the internal structural loads at selected locations, appear credible and consistent with expectations.

17 WIND ENERGY↗

Automation Improvements for Synchrotron Based Small Angle Scattering Using an Inexpensive Robotics Platform

This paper reports on the progress toward creating semi-autonomous motion control platforms for beamline applications using the iRobot Create registered platform. The goal is to create beamline research instrumentation where the motion paths are based on the local environment rather than position commanded from a control system, have low integration costs and also be scalable and easily maintainable.

43 PARTICLE ACCELERATORS↗

SU-G-BRA-01: A Real-Time Tumor Localization and Guidance Platform for Radiotherapy Using US and MRI

Purpose: To develop and validate a real-time motion management platform for radiotherapy that directly tracks tumor motion using ultrasound and MRI. This will be a cost-effective and non-invasive real-time platform combining the excellent temporal resolution of ultrasound with the excellent soft-tissue contrast of MRI. Methods: A 4D planar ultrasound acquisition during the treatment that is coupled to a pre-treatment calibration training image set consisting of a simultaneous 4D ultrasound and 4D MRI acquisition. The image sets will be rapidly matched using advanced image and signal processing algorithms, allowing the display of virtual MR images of the tumor/organ motion in real-time from an ultrasound acquisition. Results: The completion of this work will result in several innovations including: a (2D) patch-like, MR and LINAC compatible 4D planar ultrasound transducer that is electronically steerable for hands-free operation to provide real-time virtual MR and ultrasound imaging for motion management during radiation therapy; a multi- modal tumor localization strategy that uses ultrasound and MRI; and fast and accurate image processing algorithms that provide real-time information about the motion and location of tumor or related soft-tissue structures within the patient. Conclusion: If successful, the proposed approach will provide real-time guidance for radiation therapy without degrading image or treatment plan quality. The approach would be equally suitable for image-guided proton beam or heavy ion-beam therapy. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Experimental Validation of Models of a Hull-Based Tuned Mass Damper System for a Semisubmersible Floating Offshore Wind Turbine Platform

Floating offshore wind turbine designs can be further optimized if the controller and remaining systems are designed together, known as control co-design. To effectively perform control co-design, modeling tools predicting the influence of the control systems on the response of a system must be validated. This article presents an experimental validation that utilizes a scale model of a semisubmersible platform for an offshore wind turbine that is fitted with adjustable tuned mass dampers. These dampers can be tuned to attenuate either the hull-pitch resonance or the tower-bending resonance. The data from the experiment are used to validate state-of-the-art modeling tools. It is shown that the models capture the overall effects of the tuned mass dampers; however, some models overpredict the reduction in platform pitch motion when the dampers are tuned to the pitch resonance. The relative reduction in the tower-base bending moment is more consistently captured by the models when the dampers are tuned to the tower-bending resonance. However, there are significant differences in the absolute level of tower-base bending moment between the models and the experiment. Much of the differences observed are a consequence of the challenge with accurately predicting the baseline platform resonance motion and the tower-bending moment, which should be addressed in future modeling efforts.

17 WIND ENERGY↗

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger↗

Motion-Corrected 3D Sonic Anemometer for Tethersondes and Other Moving Platforms

To date, it has not been possible to apply 3D sonic anemometers on tethersondes or similar atmospheric research platforms due to the motion of the supporting platform. A tethersonde module including both a 3D sonic anemometer and associated motion correction sensors has been developed, enabling motion-corrected 3D winds to be measured from a moving platform such as a tethersonde. Blimps and other similar lifting systems are used to support tethersondes meteorological devices that fly on the tether of a blimp or similar platform. To date, tethersondes have been limited to making basic meteorological measurements (pressure, temperature, humidity, and wind speed and direction). The motion of the tethersonde has precluded the addition of 3D sonic anemometers, which can be used for high-speed flux measurements, thereby limiting what has been achieved to date with tethersondes. The tethersonde modules fly on a tether that can be constantly moving and swaying. This would introduce enormous error into the output of an uncorrected 3D sonic anemometer. The motion correction that is required must be implemented in a low-weight, low-cost manner to be suitable for this application. Until now, flux measurements using 3D sonic anemometers could only be made if the 3D sonic anemometer was located on a rigid, fixed platform such as a tower. This limited the areas in which they could be set up and used. The purpose of the innovation was to enable precise 3D wind and flux measurements to be made using tether - sondes. In brief, a 3D accelerometer and a 3D gyroscope were added to a tethersonde module along with a 3D sonic anemometer. This combination allowed for the necessary package motions to be measured, which were then mathematically combined with the measured winds to yield motion-corrected 3D winds. At the time of this reporting, no tethersonde has been able to make any wind measurement other than a basic wind speed and direction measurement. The addition of a 3D sonic anemometer is unique, as is the addition of the motion-correction sensors.

Bognar, John↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗