A High-Pressure Gas-Scintillation-Proportional Counter for the Focus of a Hard-X-Ray Telescope

We are developing a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a balloon-borne hard-x-ray telescope. The device has a total active diameter of 50 mm, of which the central 20 mm only is used, and is filled with xenon + 4% helium at a total pressure of 10 6 Pa giving a quantum efficiency of greater than 85% up to 60 keV. The detector entrance is sealed with a beryllium window, 3-mm thick, which provides useful transmission down to 6 keV, way below the atmospheric cut-off at balloon float altitudes. Scintillation light exits the detector via a UV transmitting window in its base and is registered by a Hamamatsu position-sensitive crossed-grid-readout photomultiplier tube. Initial testing is underway, quantifying light yield and energy resolution. Following that, the spatial resolution and absolute efficiency will be calibrated. Simulations show that a spatial resolution of better than 0.5 mm FWHM should be achievable up to 60 keV, and this is well matched to the angular resolution and plate scale of the mirror system. The energy resolution will be around 5% at 22 keV. Full details of the instrument design and its performance will be presented. A first flight is scheduled for the Fall of 99, on a stratospheric balloon to be launched from Fort Sumner, New Mexico.

Austin, R. A.↗

Results obtained with position sensitive multiwire proportional chambers with helium, carbon, and oxygen nuclei

Spatial resolution performance results obtained at the Lawrence Radiation Laboratory Bevatron with prototype multiwire proportional chamber spatial detectors with integral delay line readout are presented. The effects due to incident nuclei charge, chamber operating parameters, chamber design, electronics, gas mixtures, and magnetic field presence have been investigated and are discussed.

Emming, J. G.↗

Cryogenic Equivalence Principle Experiment

The purpose of this project is to test the equivalence of inertial and passive gravitational mass in an Earth-orbiting satellite. A ground-based experiment is now well developed. It consists of comparing the motions of two cylindrical test masses suspended in precision superconducting magnetic bearings and free to move along the horizontal (axis) direction. The masses are made of niobium and lead-plated aluminum. A position detector based on a SQUID magnetometer measures the differential motion between the masses. The periods of the masses are matched by adjustment of the position detector until the system is insensitive to common mode signals, and so that the experiment is less sensitive to seismic vibration. The apparatus is contained in a twelve inch helium dewar suspended in a vibration isolation stand. The stand achieves 30 db isolation from horizontal motions between 0.1 and 60 Hz, by simulating the motion of a 200 meter long pendulum with an air bearing. With this attenuation of seismic noise and a common mode rejection ratio of 10 to the 5th power in the differential mode, the ground based apparatus should have a sensitivity to equivalence principle violations of one part in 10 to the 13th power; the satellite version might have a sensitivity of one part in 10 to the 17th power.

Everitt, C. W. F.↗

Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

Gubarev, Mikhail↗

Performance of Gas Scintillation Proportional Counter Array for High-Energy X-Ray Observatory

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a High Energy X-Ray Observatory (HERO) is developed at the Marshall Space Flight Center. The array is consisted from eight GSPCs and is a part of balloon born payload scheduled to flight in May 2004. These detectors have an active area of approximately 20 square centimeters, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approximately 500 microns. The detector's energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Results of the on-earth detector calibration will be presented and in-flight detector performance will be provided, as available.

Gubarev, Mikhail↗

Determination of the efficiency of a proportional counter for detecting X-rays

A parallel beam of X-rays (approximately monoenergetic) passing through a rectangular slit and scattering from two flat mirrors comprise the X-ray test. The two mirrors are arranged in a periscope geometry so that the final reflected beam is parallel to the incident beam but displaced laterally by given amount. One of the detectors used to intercept the reflected X-rays is a one dimensional gas-filled proportional counter which is sensitive to the position (in 1 dimension) at which the X-rays are incident within its detecting "window". The total length of the anode wire of the proportional counter is 120 mm and this length can be divided electronically into a maximum of 1,024 parts. Hence, the output of an experimental run would be the number of incident X-rays that registered on each of the 1,024 channels. Each channel would represent an X-ray at a different spatial location and, hence, at a different scattering angle. In order to look at a wider range of scattering angles, the detector is placed on an optical table which can be rotated.

Williams, A. C.↗

The Burst and Transient Source Experiment for the Gamma-Ray Observatory

The Burst and Transient Source Experiment (BATSE) is a highly sensitive, all-sky monitor for the Gamma-Ray Observatory (GRO). The eight scintillation detector modules of BATSE are positioned around the GRO spacecraft to provide a uniform view of the entire sky above the horizon. Each module is 20 in. in diameter, 0.5 in. thick and operates in the energy range from 40 to 600 keV. Rough burst locations can be derived from the relative counting rates of the detectors; longer-lived (greater than 100 min) transient sources can be detected and located by earth occultations. The data system contains mass memory to allow storage of large amounts of burst data in short time intervals. Data are sorted onboard in various ways into programmable energy, time and detector domains. Details of the design and capabilities of the BATSE are presented.

Fishman, G. J.↗

EXIST: The Next Large GRB Observatory

Studies have begun on the EXIST (Energetic X-ray Imaging Survey Telescope) Mission as a Black Hole Survey 'Einstein Probe', a major element in the new NASA Beyond Einstein Program in the Office of Space Science. This program was approved by the US Congress, in February 2003 as part of the NASA FY2004 NASA budget. EXIST is planned as a very wide-field coded aperture telescope and a positional accuracy for GRBs better than one arc-minute. The baseline detectors are Cadmium-Zinc-Telluride (CZT), with a total sensitive area of approximately 8 m2. EXIST will use SWIFT as a pathfinder mission; the findings of SWIFT will refine the scientific objectives of EXIST and will help to determine many of its design parameters. EXIST will study early star and galaxy formation at high redshifts through observations of thousands of GRBs, their afterglows and host galaxies. It is intended that the international GRB community will play a large role in EXIST through direct participation as well as with complementary observational programs, both space-based and ground-based. Some preliminary design features and capabilities of the EXIST Mission will be presented.

Fishman, Gerald J.↗

Solar Wind Charge Exchange Contribution To The ROSAT Sky Survey Maps

DXL (Diffuse X-ray emission from the Local Galaxy) is a sounding rocket mission designed to estimate the contribution of solar wind charge eXchange (SWCX) to the diffuse X-ray background and to help determine the properties of the Local Hot Bubble. The detectors are large area thin-window proportional counters with a spectral response that is similar to that of the PSPC (Position Sensitive Proportional Counters) used in the ROSAT All Sky Survey (RASS). A direct comparison of DXL and RASS data for the same part of the sky viewed from quite different vantage points in the solar system, and the assumption of approximate isotropy for the solar wind, allowed us to quantify the SWCX contribution to all six RASS bands (R1-R7, excluding R3). We find that the SWCX contribution at l = 140 degrees, b = 0 degrees, where the DXL path crosses the Galactic plane, is 33 percent plus or minus 6 percent (statistical) plus or minus 12 percent (systematic) for R1, 44 percent plus or minus 6 percent plus or minus 5 percent for R2, 18 percent plus or minus 12 percent plus or minus 11 percent for R4, 14 percent plus or minus 11 percent plus or minus 9 percent for R5, and negligible for the R6 and R7 bands. Reliable models for the distribution of neutral H and He in the solar system permit estimation of the contribution of interplanetary SWCX emission over the the whole sky and correction of the RASS maps. We find that the average SWCX contribution in the whole sky is 26 percent plus or minus 6 percent plus or minus 13 percent for R1, 30 percent plus or minus 4 percent plus or minus 4 percent for R2, 8 percent plus or minus 5 percent plus or minus 5 percent for R4, 6 percent plus or minus 4 percent plus or minus 4 percent for R5, and negligible for R6 and R7.

sxcx↗

Combined sun-acquisition and sun gate-sensor system for spacecraft attitude control

Arrangement combines acquisition and gate functions and reduces sensitivity so that attitude control is effective regardless of changes in solar intensity. There are five photoconductive detectors all electrically interconnected. Detectors are so positioned that, regardless of spacecraft orientation at any instant of interest, at least one detector is illuminated.

Schmidt, L. F.↗

Beam patterns of light-emitting diodes

IR-sensitive film, placed at various source-to-detector distances, records output beam pattern of LED. Information is then used to determine optimum position of detector surface for maximum radiation interception.

Thomas, E. F., Jr.↗

Adjustable mount for electro-optic transducers in an evacuated cryogenic system

The invention is an adjustable mount for positioning an electro-optic transducer in an evacuated cryogenic environment. Electro-optic transducers are used in this manner as high sensitivity detectors of gas emission lines of spectroscopic analysis. The mount is made up of an adjusting mechanism and a transducer mount. The adjusting mechanism provided five degrees of freedom, linear adjustments and angular adjustments. The mount allows the use of an internal lens to focus energy on the transducer element thereby improving the efficiency of the detection device. Further, the transducer mount, although attached to the adjusting mechanism, is isolated thermally such that a cryogenic environment can be maintained at the transducer while the adjusting mechanism remains at room temperature. Radiation shields also are incorporated to further reduce heat flow to the transducer location.

Crossley, Edward A., Jr.↗

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.↗

Side-viewing detector for a vacuum ultraviolet reflectometer.

The problem of detector response, which arises in the application of the reflectance vs angle of incidence method to the determination of optical constants in the vacuum UV spectral region is discussed. The analysis is performed for the side-viewing 1P21 detector sensitized with sodium salycilate. To take advantage of the wide selection photomultipliers available in the end-on configuration, a scheme for converting the end-on types to a side viewing geometry with a response uniform over several degrees of detector rotation is developed. It consists of a 32-mm diam spherical collector, located at the end of a cylindrical photomultiplier holder, with 12-mm entrance and viewing ports and a position for the sensitized screen also 12-mm in diameter.-

Osantowski, J. F.↗

The SWIFT Gamma-Ray Burst X-Ray Telescope

The Swift Gamma-Ray Burst Explorer is designed to make prompt multi-wavelength observations of Gamma-Ray Bursts and GRB afterglows. The X-ray Telescope enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM-Newton/ EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with an effective area of more than 120 sq cm at 1.5 keV, a field of view of 23.6 x 23.6 arcminutes, and an angular resolution of 18 arcseconds (HPD). The detection sensitivity is 2x10(exp 14) erg/sq cm/s in 10(exp 4) seconds. The instrument provides automated source detection and position reporting within 5 seconds of target acquisition. It can also measure the redshifts of GRBs with Iron line emission or other spectral features. The XRT operates in an auto-exposure mode, adjusting the CCD readout mode automatically to optimize the science return as the source intensity fades. The XRT measures spectra and lightcurves of the GRB afterglow beginning about a minute after the burst and follows each burst for days or weeks. We provide an overview of the X-ray Telescope scientific background from which the systems engineering requirements were derived, with specific emphasis on the design and qualification aspects from conception through to launch. We describe the impact on cleanliness and vacuum requirements for the instrument low energy response and to maintain the high sensitivity to the fading signal of the Gamma-ray Bursts.

Hill, J. E.↗

Analysis prcedures for ROSAT XRT/PSPC observations of extended objects and the diffuse background

Proper reduction of ROSAT observations of extended sources or the diffuse background requires techniques that are quite different from the standard point-source analysis. We describe in detail an appropriate set of procedures for this purpose for the X-ray Telescope (XRT), Position Sensitive Proportional Counter (PSPC). We define a standard set of pulse-height bands recommended for analyzing extended structure and describe the use of detector efficiency maps for proper flat-fielding of images. Sources of noncosmic background contamination and their modeling and subtraction are discussed and demonstrated. IDL routines for implementing these data reduction procedures are being made available to the community through the ROSAT IDL library maintained at Goddard Space Flight Center (GSFC).

Snowden, S. L.↗

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

Dosimetric mapping inside biorack (7-IML-1)

This experiment documents the radiation environment inside Biorack and compares it to theoretical predictions. Other experiments inside Biorack need this information to determine whether changes to samples are caused by radiation or microgravity. Dosimetric stacks, each with 20 to 100 sheets of plastic detector foils (cellulose nitrate, Lexan, and CR39) and nuclear emulsions of different radiation sensitivity are packed together with Thermoluminescence dosimeters (TLD) inside Type 1 containers. Crew members place two stacks in the 37 C incubator and four in the 36 C incubator, two of which are placed on the 1 g centrifuge. Two stacks are located in a stowage position at ambient temperature. After the mission, the plastic detectors are etched and the nuclear emulsions are developed similar to photographic emulsions. The traces resulting from the interaction of heavy ions with matter can then be evaluated under the microscope. The number, charge, and energy of the particles will be determined. From the TLD readings, the absorbed dose of the low LET components will be received.